Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLASMA DIAGNOSTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Diagnosis of gas temperature, electron temperature, and electron density in helium atmospheric pressure plasma jet

The optical emission spectra of helium atmospheric pressure plasma jet (APPJ) are captured with a three grating spectrometer. The grating primary spectrum covers the whole wavelength range from 200 nm to 900 nm, with the overlapped grating secondary spectrum appearing from 500 nm to 900 nm, which has a higher resolution than that of the grating primary spectrum. So the grating secondary spectrum of OH (A{sup 2}{Sigma} {sup +}({upsilon} Prime = 0) {yields} X{sup 2}{Pi}({upsilon} Double-Prime = 0)) is employed to calculate the gas temperature (T{sub g}) of helium APPJ. Moreover, the electron temperature (T{sub e}) is deduced from the Maxwellian electron energy distribution combining with T{sub g}, and the electron density (n{sub e}) is extracted from the plasma absorbed power. The results are helpful for understanding the physical property of APPJs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Seeded optical breakdown of molecular and noble gases

We report experimental results on the dual laser-pulse plasma excitation in various gases at atmospheric pressure. Dilute plasma channels generated through filamentation of ultraintense femtosecond laser pulses in air, argon, and helium are densified through the application of multi-Joule nanosecond heater pulses. Optical breakdown in atomic gases can be achieved for considerably longer delays between femtosecond and nanosecond pulses compared to that in molecular gases. The densification of the seed channel in molecular gases is always accompanied by its fragmentation into discrete bubbles, while in atomic gases the densified channel remains smooth and continuous.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simultaneous imaging electron- and ion-feature Thomson scattering measurements of radiatively heated Xe

Uniform density and temperature Xe plasmas have been produced over >4 mm scale-lengths using x-rays generated in a cylindrical Pb cavity. The cavity is 750 {mu}m in depth and diameter, and is heated by a 300 J, 2 ns square, 1054 nm laser pulse focused to a spot size of 200 {mu}m at the cavity entrance. The plasma is characterized by simultaneous imaging Thomson scattering measurements from both the electron and ion scattering features. The electron feature measurement determines the spatial electron density and temperature profile, and using these parameters as constraints in the ion feature analysis allows an accurate determination of the charge state of the Xe ions. The Thomson scattering probe beam is 40 J, 200 ps, and 527 nm, and is focused to a 100 {mu}m spot size at the entrance of the Pb cavity. Each system has a spatial resolution of 25 {mu}m, a temporal resolution of 200 ps (as determined by the probe duration), and a spectral resolution of 2 nm for the electron feature system and 0.025 nm for the ion feature system. The experiment is performed in a Xe filled target chamber at a neutral pressure of 3-10 Torr, and the x-rays produced in the Pb ionize and heat the Xe to a charge state of 20{+-}4 at up to 200 eV electron temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Statistical characterization of the reproducibility of neutron emission of small plasma focus devices

The purpose of this work is to discuss the techniques related to the detection of fast pulsed neutrons produced in plasma focus (PF) devices, the statistical analysis of the corresponding data, and the methodologies for evaluation of the device performance in low emission neutron sources. A general mathematical framework is presented for the assessment of the reproducibility of the neutron emission of small PF devices given the shot-to-shot distribution and detector efficiency. The effect on the reproducibility in case of using two independent detectors is also discussed. The analysis is applied to the neutron emission of the plasma focus device PF-50J operating in repetitive mode (0.1-0.5 Hz and 65 J bank energy).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Axial force imparted by a current-free magnetically expanding plasma

The axial force imparted from a magnetically expanding, current-free, radiofrequency plasma is directly measured. For an argon gas flow rate of 25 sccm and an effective rf input power of {approx}800W, a maximum force of {approx}6mN is obtained; {approx}3mN of which is transmitted via the expanding magnetic field. The measured forces are reasonably compared with a simple fluid model associated with the measured electron pressure. The model suggests that the total force is the sum of an electron pressure inside the source and a Lorentz force due to the electron diamagnetic drift current and the applied radial magnetic field. It is shown that the Lorentz force is greatest near the magnetic nozzle surface where the radial pressure gradient is largest.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Invited Article: Relation between electric and magnetic field structures and their proton-beam images

Proton imaging is commonly used to reveal the electric and magnetic fields that are found in high energy density plasmas. Presented here is an analysis of this technique that is directed towards developing additional insight into the underlying physics. This approach considers: formation of images in the limits of weak and strong intensity variations; caustic formation and structure; image inversion to obtain line-integrated field characteristics; direct relations between images and electric or magnetic field structures in a plasma; imaging of sharp features such as Debye sheaths and shocks. Limitations on spatial and temporal resolution are assessed, and similarities with optical shadowgraphy are noted. Synthetic proton images are presented to illustrate the analysis. These results will be useful for quantitatively analyzing experimental proton imaging data and verifying numerical codes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Imaging spectroscopy diagnosis of internal electron temperature and density distributions of plasma cloud surrounding hydrogen pellet in the Large Helical Device

To investigate the behavior of hydrogen pellet ablation, a novel method of high-speed imaging spectroscopy has been used in the Large Helical Device (LHD) for identifying the internal distribution of the electron density and temperature of the plasma cloud surrounding the pellet. This spectroscopic system consists of a five-branch fiberscope and a fast camera, with each objective lens having a different narrow-band optical filter for the hydrogen Balmer lines and the background continuum radiation. The electron density and temperature in the plasma cloud are obtained, with a spatial resolution of about 6 mm and a temporal resolution of 5 Multiplication-Sign 10{sup -5} s, from the intensity ratio measured through these filters. To verify the imaging, the average electron density and temperature also have been measured from the total emission by using a photodiode, showing that both density and temperature increase with time during the pellet ablation. The electron density distribution ranging from 10{sup 22} to 10{sup 24} m{sup -3} and the temperature distribution around 1 eV have been observed via imaging. The electron density and temperature of a 0.1 m plasma cloud are distributed along the magnetic field lines and a significant electron pressure forms in the plasma cloud for typical experimental conditions of the LHD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coded aperture imaging of fusion source in a plasma focus operated with pure D{sub 2} and a D{sub 2}-Kr gas admixture

The coded aperture imaging (CAI) technique has been used to investigate the spatial distribution of DD fusion in a 1.6 kJ plasma focus (PF) device operated in, alternatively, pure deuterium or deuterium-krypton admixture. The coded mask pattern is based on a singer cyclic difference set with 25% open fraction and positioned close to 90 Degree-Sign to the plasma focus axis, with CR-39 detectors used to register tracks of protons from the D(d, p)T reaction. Comparing the coded aperture imaging proton images for pure D{sub 2} and D{sub 2}-Kr admixture operation reveals clear differences in size, density, and shape between the fusion sources for these two cases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray backlight measurement of preformed plasma by kJ-class petawatt LFEX laser

Foot and pedestal pulses that precede the main pulse from a high-intensity laser greatly affect laser-plasma interactions. Especially in fast ignition schemes, preceding pulses generate a plasma prior to irradiation by the main pulse. This results in a too energetic and divergent electron beam being generated in the preformed plasma, which reduces the energy coupling efficiency from the heating laser to the dense fuel core. A preformed plasma with a density scale length of 40-60 {mu}m was observed by a time- and space-resolved x-ray backlight technique using the LFEX laser system at the Institute of Laser Engineering, Osaka University. Preceding pulses (i.e., the foot and pedestal) of the LFEX were characterized by comparing observations with calculations results obtained using a two-dimension (2D) radiation-hydrodynamic simulation code. In a separate experiment, the 2D code was benchmarked with the experimentally observed hydrodynamic behavior of a gold plasma produced by a nanosecond laser pulse that mimicked foot and pedestal pulses (intensity: 1 Multiplication-Sign 10{sup 11}-1 Multiplication-Sign 10{sup 12}W/cm{sup 2}). The preceding pulses were estimated to have an intensity of 1 Multiplication-Sign 10{sup 12}-10{sup 13}W/cm{sup 2}, a duration of 2.0 ns, and a spot diameter at the target of 200-600 {mu}m by comparing the measured hydrodynamics of the preformed plasma with that calculated by the 2D hydrodynamic simulation code.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Boron-rich plasma by high power impulse magnetron sputtering of lanthanum hexaboride

Boron-rich plasmas have been obtained using a LaB{sub 6} target in a high power impulse sputtering (HiPIMS) system. The presence of {sup 10}B{sup +}, {sup 11}B{sup +}, Ar{sup 2+}, Ar{sup +}, La{sup 2+}, and La{sup +} and traces of La{sup 3+}, {sup 12}C{sup +}, {sup 14}N{sup +}, and {sup 16}O{sup +} have been detected using an integrated mass and energy spectrometer. Peak currents as low as 20 A were sufficient to obtain plasma dominated by {sup 11}B{sup +} from a 5 cm planar magnetron. The ion energy distribution function for boron exhibits an energetic tail extending over several 10 eV, while argon shows a pronounced peak at low energy (some eV). This is in agreement with models that consider sputtering (B, La) and gas supply (from background and 'recycling'). Strong voltage oscillations develop at high current, greatly affecting power dissipation and plasma properties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cyclic powder formation during pulsed injection of hexamethyldisiloxane in an axially asymmetric radiofrequency argon discharge

A new approach of periodic production of dusty plasma consisting of pulsed injection of hexamethyldisiloxane (HMDSO) in argon axially asymmetric radiofrequency (RF) discharge was investigated in this work. The range of plasma operating conditions in which this dusty plasma can exist was closely examined. The obtained results clearly show that a net periodicity in the formation/disappearance of dust particles in the plasma can be maintained on a very large scale of discharge duration. The significance of discharge axial asymmetry to the dust particles behaviour in the plasma is revealed by the development of an asymmetric in shape void shifted towards the powered RF electrode. The key role of the reactive gas and its pulsed injection on each stage of the oscillating process of formation/disappearance of dust particles is disclosed by optical and electrical measurements. It is shown that the period of dusty plasma formation/disappearance is inversely related to the HMDSO injection time. Moreover, the impact of time injection over short period (5 s) is examined. It indicates the conflicting role played by the HMDSO on the reduction of dusty plasma during the reactive gas injection and the reappearance of particles in the plasma during the time off. The electronegative behavior of the plasma in the presence of negatively charged particles seems to explain the energetic modifications in the discharge. A frequency analysis of the floating potential reveals all these cyclic processes. Particularly, in the 10-200 Hz frequency range, the presence and the evolution of dust particles in the plasma over one generation can be observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microwave plasma source operating with atmospheric pressure air-water mixtures

The overall performance of a surface wave driven air-water plasma source operating at atmospheric pressure and 2.45 GHz has been analyzed. A 1D model previously developed has been improved in order to describe in detail the creation and loss processes of active species of interest. This model provides a complete characterization of the axial structure of the source, including the discharge and the afterglow zones. The main electron creation channel was found to be the associative ionization process N + O {yields} NO{sup +}+ e. The NO(X) relative density in the afterglow plasma jet ranges from 1.2% to 1.6% depending on power and water percentage, according to the model predictions and the measurements. Other types of species such as NO{sub 2} and nitrous acid HNO{sub 2} have also been detected by mass and Fourier Transform Infrared spectroscopy. The relative population density of O({sup 3}P) ground state atoms increases from 8% to 10% in the discharge zone when the input microwave power increases from 200 to 400 W and the water percentage from 1% to 10%. Furthermore, high densities of O{sub 2}(a{sup 1}{Delta}{sub g}) singlet delta oxygen molecules and OH radicals (1% and 5%, respectively) can be achieved in the discharge zone. In the late afterglow the O{sub 2}(a{sup 1}{Delta}{sub g}) density is about 0.1% of the total density. This plasma source has a flexible operation and potential for channeling the energy in ways that maximize the density of active species of interest.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamics of femto- and nanosecond laser ablation plumes investigated using optical emission spectroscopy

We investigated the spatial and temporal evolution of temperature and electron density associated with femto- and nanosecond laser-produced plasmas (LPP) from brass under similar laser fluence conditions. For producing plasmas, brass targets were ablated in vacuum employing pulses either from a Ti:Sapphire ultrafast laser (40 fs, 800 nm) or from a Nd:YAG laser (6 ns, 1064 nm). Optical emission spectroscopy is used to infer the density and temperature of the plasmas. The electron density (n{sub e}) was estimated using Stark broadened profiles of isolated lines while the excitation temperature (T{sub exc}) was estimated using the Boltzmann plot method. At similar fluence levels, continuum and ion emission are dominant in ns LPP at early times (<50 ns) followed by atomic emission, while the fs LPP provided an atomic plume throughout its visible emission lifetime. Though both ns and fs laser-plasmas showed similar temperatures ({approx}1 eV), the fs LPP is found to be significantly denser at shorter distances from the target surface as well as at early phases of its evolution compared to ns LPP. Moreover, the spatial extension of the plume emission in the visible region along the target normal is larger for fs LPP in comparison with ns LPP.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microwave ECR plasma electron flood for low pressure wafer charge neutralization

Modern ion implanters typically use dc arc discharge Plasma Electron Floods (PEFs) to neutralize wafer charge. The arc discharge requires using at least some refractory metal hardware, e.g. a thermionically emitting filament, which can be undesirable in applications where no metallic contamination is critical. rf discharge PEFs have been proposed to mitigate contamination risks but the gas flows required can result in high process chamber pressures. Axcelis has developed a microwave electron cyclotron resonance (ECR) PEF to provide refractory metals contamination-free wafer neutralization with low gas flow requirement. Our PEF uses a custom, reentrant cusp magnet field providing ECR and superior electron confinement. Stable PEF operation with extraction slits sized for 300 mm wafers can be attained at Xe gas flows lower than 0.2 sccm. Electron extraction currents can be as high as 20 mA at absorbed microwave powers < 70 W. On Axcelis' new medium current implanter, plasma generation has proven robust against pressure transients caused by, for example, photoresist outgassing by high power ion beams. Charge monitor and floating potential measurements along the wafer surface corroborate adequate wafer charge neutralization for low energy, high current ion beams.

43 PARTICLE ACCELERATORS↗

Ion beams extraction and measurements of plasma parameters on a multi-frequencies microwaves large bore ECRIS with permanent magnets

We have developed an all-permanent magnet large bore electron cyclotron resonance ion source (ECRIS) for broad ion beam processing. The cylindrically comb-shaped magnetic field configuration is adopted for efficient plasma production and good magnetic confinement. To compensate for disadvantages of fixed magnetic configuration, a traveling wave tube amplifier (TWTA) is used. In the comb-shaped ECRIS, it is difficult to achieve controlling ion beam profiles in the whole inside the chamber by using even single frequency-controllable TWTA (11-13GHz), because of large bore size with all-magnets. We have tried controlling profiles of plasma parameters and then those of extracted ion beams by launching two largely different frequencies simultaneously, i.e., multi-frequencies microwaves. Here we report ion beam profiles and corresponding plasma parameters under various experimental conditions, dependence of ion beams against extraction voltages, and influence of different electrode positions on the electron density profile.

43 PARTICLE ACCELERATORS↗

Oscillation phenomena of a plasma produced by an AC driven hot cathode

Amplitude of oscillating discharge current has been measured for Bernas-type ion source equipped with an alternating current heated hot tungsten filament cathode. Measurements have been made by changing the filament diameter from 0.2 mm to 0.7 mm, and by changing the DC discharge current from 0.1 A to 1.5 A. The fluctuation amplitude of the discharge current was found decreased as the diameter of the filament was enlarged. The fluctuation amplitude took the minimum value at a frequency from several hundred Hz to 1 kHz depending upon the filament diameter and DC discharge current. For example, the relative oscillation amplitude was the smallest at 1 kHz for 0.7 mm diameter filament. Increase in discharge current had reduced the minimum oscillation amplitude, and increased the frequency at which the oscillating amplitude took the minimum. Fundamental mechanisms relevant to these characteristics of oscillation amplitude of discharge current from an AC driven hot cathode filament are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-synchronized continuous wave laser-induced fluorescence on an oscillatory xenon discharge

A novel approach to time-synchronizing laser-induced fluorescence measurements to an oscillating current in a 60 Hz xenon discharge lamp using a continuous wave laser is presented. A sample-hold circuit is implemented to separate out signals at different phases along a current cycle, and is followed by a lock-in amplifier to pull out the resulting time-synchronized fluorescence trace from the large background signal. The time evolution of lower state population is derived from the changes in intensity of the fluorescence excitation line shape resulting from laser-induced fluorescence measurements of the 6s{sup Prime }[1/2]{sub 1}{sup 0}-6p{sup Prime }[3/2]{sub 2} xenon atomic transition at {lambda}= 834.68 nm. Results show that the lower state population oscillates at twice the frequency of the discharge current, 120 Hz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pulsed laser ablation plasmas generated in CO{sub 2} under high-pressure conditions up to supercritical fluid

Pulsed laser ablation of solids in supercritical media has a large potential for nanomaterials fabrication. We investigated plasmas generated by pulsed laser ablation of Ni targets in CO{sub 2} at pressures ranging from 0.1 to 16 MPa at 304.5 K. Plasma species were characterized by optical emission spectroscopy, and the evolution of cavitation bubbles and shockwaves were observed by time-resolved shadowgraph imaging. Ni and O atomic emissions decreased with increasing gas pressure; however, near the critical point the intensities reached local maxima, probably due to the enhancement of the plasma excitation and effective quenching resulting from the large density fluctuation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗