At least 973 records · Page 54

Cryogenic readout techniques for germanium detectors

High Purity Germanium detectors are used in many applications, from nuclear and astro-particle physics, to homeland security or environment protection. Although quite standard configurations are often used, with cryostats, charge sensitive amplifiers and analog or digital acquisition systems all commercially available, it might be the case that a few specific applications, e.g. satellites, portable devices, cryogenic physics experiments, etc. also require the development of a few additional or complementary techniques. An interesting case is for sure GERDA, the Germanium Detector Array experiment, searching for neutrino-less double beta decay of {sup 76}Ge at the Gran Sasso National Laboratory of INFN - Italy. In GERDA the entire detector array, composed of semi-coaxial and BEGe naked crystals, is operated suspended inside a cryostat filled with liquid argon, that acts not only as cooling medium and but also as an active shield, thanks to its scintillation properties. These peculiar circumstances, together with the additional requirement of a very low radioactive background from all the materials adjacent to the detectors, clearly introduce significant constraints on the design of the Ge front-end readout electronics. All the Ge readout solutions developed within the framework of the GERDA collaboration, for both Phase I and Phase II, will be briefly reviewed, with their relative strength and weakness compared together and with respect to ideal Ge readout. Finally, the digital processing techniques developed by the GERDA collaboration for energy estimation of Ge detector signals will be recalled. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observing mergers of nonspinning black-hole binaries

Advances in the field of numerical relativity now make it possible to calculate the final, most powerful merger phase of binary black-hole coalescence for generic binaries. The state of the art has advanced well beyond the equal-mass case into the unequal-mass and spinning regions of parameter space. We present a study of the nonspinning portion of parameter space, primarily using an analytic waveform model tuned to available numerical data, with an emphasis on observational implications. We investigate the impact of varied mass-ratio on merger signal-to-noise ratios for several detectors, and compare our results with expectations from the test-mass limit. We note a striking similarity of the waveform phasing of the merger waveform across the available mass ratios. Motivated by this, we calculate the match between our 1:1 (equal-mass) and 4:1 mass-ratio waveforms during the merger as a function of location on the source sky, using a new formalism for the match that accounts for higher harmonics. This is an indicator of the amount of degeneracy in mass-ratio for mergers of moderate-mass-ratio systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MO-PIS-Exhibit Hall-01: Imaging: CT Dose Optimization Technologies I

Partners in Solutions is an exciting new program in which AAPM partners with our vendors to present practical “hands-on” information about the equipment and software systems that we use in our clinics. The imaging topic this year is CT scanner dose optimization capabilities. Note that the sessions are being held in a special purpose room built on the Exhibit Hall Floor, to encourage further interaction with the vendors. Dose Optimization Capabilities of GE Computed Tomography Scanners Presentation Time: 11:15 – 11:45 AM GE Healthcare is dedicated to the delivery of high quality clinical images through the development of technologies, which optimize the application of ionizing radiation. In computed tomography, dose management solutions fall into four categories: employs projection data and statistical modeling to decrease noise in the reconstructed image - creating an opportunity for mA reduction in the acquisition of diagnostic images. Veo represents true Model Based Iterative Reconstruction (MBiR). Using high-level algorithms in tandem with advanced computing power, Veo enables lower pixel noise standard deviation and improved spatial resolution within a single image. Advanced Adaptive Image Filters allow for maintenance of spatial resolution while reducing image noise. Examples of adaptive image space filters include Neuro 3-D filters and Cardiac Noise Reduction Filters. AutomA adjusts mA along the z-axis and is the CT equivalent of auto exposure control in conventional x-ray systems. Dynamic Z-axis Tracking offers an additional opportunity for dose reduction in helical acquisitions while SmartTrack Z-axis Tracking serves to ensure beam, collimator and detector alignment during tube rotation. SmartmA provides angular mA modulation. ECG Helical Modulation reduces mA during the systolic phase of the heart cycle. SmartBeam optimization uses bowtie beam-shaping hardware and software to filter off-axis x-rays - minimizing dose and reducing x-ray scatter. The DICOM Radiation Dose Structured Report (RDSR) generates a dose report at the conclusion of every examination. Dose Check preemptively notifies CT operators when scan parameters exceed user-defined dose thresholds. DoseWatch is an information technology application providing vendor-agnostic dose tracking and analysis for CT (and all other diagnostic x-ray modalities) SnapShot Pulse improves coronary CTA dose management. VolumeShuttle uses two acquisitions to increase coverage, decrease dose, and conserve on contrast administration. Color-Coding for Kids applies the Broselow-Luten Pediatric System to facilitate pediatric emergency care and reduce medical errors. FeatherLight achieves dose optimization through pediatric procedure-based protocols. Adventure Series scanners provide a child-friendly imaging environment promoting patient cooperation with resultant reduction in retakes and patient motion. Philips CT Dose Optimization Tools and Advanced Reconstruction Presentation Time: 11:45 ‘ 12:15 PM The first part of the talk will cover “Dose Reduction and Dose Optimization Technologies” present in Philips CT Scanners. The main Technologies to be presented include: DoseRight and tube current modulation (DoseRight, Z-DOM, 3D-DOM, DoseRight Cardiac) Special acquisition modes Beam filtration and beam shapers Eclipse collimator and ClearRay collimator NanoPanel detector DoseRight will cover automatic tube current selection that automatically adjusts the dose for the individual patient. The presentation will explore the modulation techniques currently employed in Philips CT scanners and will include the algorithmic concepts as well as illustrative examples. Modulation and current selection technologies to be covered include the Automatic Current Selection component of DoseRight, ZDOM longitudinal dose modulation, 3D-DOM (combination of longitudinal and rotational dose modulation), Cardiac Dose right (an ECG based dose modulation scheme), and the DoseRight Index (DRI) IQ index. The special acquisition modes covers acquisition techniques such as prospective gating that is designed to reduce exposure to the patient through the Cardiac Step and Shoot scan mode. This mode can substitute the much higher dose retrospective scan modes for certain types of cardiac imaging. The beam filtration and beam shaper portion will discuss the variety of filtration and beam shaping configurations available on Philips scanners. This topic includes the x-ray beam characteristics, tube filtration as well as dose compensator characteristics. The Eclipse collimator, ClearRay collimator and the NanoPanel detector portion will discuss additional technologies specific to wide coverage CT that address some of the unique challenges encountered and techniques employed to optimize image quality and optimize dose utilization. The Eclipse collimator reduces extraneous exposure by actively blocking the radiation tails at either end of helical scans that do not contribute to the image generation. The ClearRay collimator and the NanoPanel detector optimize the quality of the signal that reaches the detectors by addressing the increased scattered radiation present in wide coverage and the NanoPanel detector adds superior electronic noise characteristics valuable when imaging at a low dose level. The second part of the talk will present “Advanced Reconstruction Technologies” currently available on Philips CT Scanners. The talk will cover filtered back projection (FBP), iDose4 and Iterative Model Reconstruction (IMR). Each reconstruction method will include a discussion of the algorithm as well as similarities and differences between the algorithms. Examples illustrating the merits of each algorithm will be presented, and techniques and metrics to characterize the performance of each type of algorithm will be presented. The Filtered Back projection portion will discuss and provide a brief summary of relevant standard image reconstruction techniques in common use, and discuss the common tradeoffs when using the FBP algorithm. The iDose4 portion will present the algorithms used for iDose4 as well the different levels. The meaning of different levels of iDose4 available will be presented and quantified. Guidelines for selection iDose4 parameters based on the imaging need will be explained. The different image quality goals available with iDose4 and specifically how iDose4 enables noise reduction, spatial resolution improvement or both will be explained. The approaches to leveraging the benefits of iDose4 such as improved spatial resolution, decreased noise, and artifact prevention will be described and quantified; and measurements and metrics behind the improvements will be presented. The image quality benefits in specific imaging situations as well as how to best combine the technology with other dose reduction strategies to ensure the best image quality at a given dose level will be presented. Insight into the IMR algorithm as well as contrast to the iDose4 techniques and performance characteristics will be discussed. Metrics and techniques for characterizing this class of algorithm and IQ performance will be presented. The image quality benefits and the dose reduction capabilities of IMR will be explored. Illustrative examples of the noise reduction, spatial resolution improvement, and low contrast detectability improvements of the reconstruction method will be presented: clinical cases and phantom measurements demonstrating the benefits of IMR in the areas of low dose imaging, spatial resolution and low contrast resolution are discussed and the technical details behind the measurements will be presented compared to both iDose4 and traditional filtered back projection (FBP)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of planar silicon pixel sensors with the RD53A readout chip for the Phase-2 Upgrade of the CMS Inner Tracker

The Large Hadron Collider at CERN will undergo an upgrade inorder to increase its luminosity to7.5 × 10$^{34}$ cm$^{-2}$s$^{-1}$. The increased luminosityduring this High-Luminosity running phase, starting around 2029,means a higher rate of proton-proton interactions, hence a largerionizing dose and particle fluence for the detectors. The currenttracking system of the CMS experiment will be fully replaced inorder to cope with the new operating conditions. Prototype planarpixel sensors for the CMS Inner Tracker with square50 μm × 50 μm and rectangular100 μm × 25 μm pixels read out by theRD53A chip were characterized in the lab and at the DESY-II testbeamfacility in order to identify designs that meet the requirements ofCMS during the High-Luminosity running phase. A spatial resolutionof approximately 3.4 μm (2 μm) is obtained using themodules with 50 μm × 50 μm(100 μm × 25 μm) pixels at the optimalangle of incidence before irradiation. After irradiation to a 1 MeVneutron equivalent fluence ofΦ$_{eq}$ = 5.3 × 10$^{15}$ cm$^{-2}$, a resolution of9.4 μm is achieved at a bias voltage of 800 V using a modulewith 50 μm × 50 μm pixel size. All modulesretain a hit efficiency in excess of 99% after irradiation tofluences up to 2.1 × 10$^{16}$ cm$^{-2}$. Further studies ofthe electrical properties of the modules, especially crosstalk, arealso presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A cylindrical quadrupole ion trap in combination with an electrospray ion source for gas-phase luminescence and absorption spectroscopy

A relatively simple setup for collection and detection of light emitted from isolated photo-excited molecular ions has been constructed. It benefits from a high collection efficiency of photons, which is accomplished by using a cylindrical ion trap where one end-cap electrode is a mesh grid combined with an aspheric condenser lens. The geometry permits nearly 10% of the emitted light to be collected and, after transmission losses, approximately 5% to be delivered to the entrance of a grating spectrometer equipped with a detector array. The high collection efficiency enables the use of pulsed tunable lasers with low repetition rates (e.g., 20 Hz) instead of continuous wave (cw) lasers or very high repetition rate (e.g., MHz) lasers that are typically used as light sources for gas-phase fluorescence experiments on molecular ions. A hole has been drilled in the cylinder electrode so that a light pulse can interact with the ion cloud in the center of the trap. Simulations indicate that these modifications to the trap do not significantly affect the storage capability and the overall shape of the ion cloud. The overlap between the ion cloud and the laser light is basically 100%, and experimentally >50% of negatively charged chromophore ions are routinely photodepleted. The performance of the setup is illustrated based on fluorescence spectra of several laser dyes, and the quality of these spectra is comparable to those reported by other groups. Finally, by replacing the optical system with a channeltron detector, we demonstrate that the setup can also be used for gas-phase action spectroscopy where either depletion or fragmentation is monitored to provide an indirect measurement on the absorption spectrum of the ion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light yield in DarkSide-10: A prototype two-phase argon TPC for dark matter searches

As part of the DarkSide program of direct dark matter searches using liquid argon TPCs, a prototype detector with an active volume containing 10 kg of liquid argon, DarkSide-10, was built and operated underground in the Gran Sasso National Laboratory in Italy. A critically important parameter for such devices is the scintillation light yield, as photon statistics limits the rejection of electron-recoil backgrounds by pulse shape discrimination. We have measured the light yield of DarkSide-10 using the readily-identifiable full-absorption peaks from gamma ray sources combined with single-photoelectron calibrations using low-occupancy laser pulses. For gamma lines of energies in the range 122-1275 keV, we get consistent light yields averaging 8.887+-0.003(stat)+-0.444(sys) p.e./keVee. With additional purification, the light yield measured at 511 keV increased to 9.142+-0.006(stat) p.e./keVee.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonlinear, noniterative, single-distance phase retrieval and developmental biology

For coherent X-ray imaging, based on phase contrast through free-space Fresnel propagation, we discuss two noniterative, nonlinear approaches to the phase-retrieval problem from a single-distance intensity map of a pure-phase object. On one hand, a perturbative set-up is proposed where nonlinear corrections to the linearized transport-of-intensity situation are expanded in powers of the object-detector distance z and are evaluated in terms of the linear estimate. On the other hand, a nonperturbative projection algorithm, which is based on the (linear and local) contrast-transfer function (CTF), works with an effective phase in Fourier space. This effective phase obeys a modified CTF relation between intensity contrast at z > 0 and phase contrast at z= 0: Unphysical singularities of the local CTF model are cut off to yield 'quasiparticles' in analogy to the theory of the Fermi liquid. By identifying the positions of the zeros of the Fourier transformed intensity contrast as order parameters for the dynamical breaking of scaling symmetry we investigate the phase structure of the forward-propagation problem when interpreted as a statistical system. Results justify the quasiparticle approach for a wide range of intermediary phase variations. The latter algorithm is applied to data from biological samples recorded at the beamlines TopoTomo and ID19 at ANKA and ESRF, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase transitions in freeze-dried systems - quantification using in situ synchrotron X-ray diffractometry

The purpose is: (1) To develop a synchrotron X-ray diffraction (SXRD) method to monitor phase transitions during the entire freeze-drying cycle. Aqueous sodium phosphate buffered glycine solutions with initial glycine to buffer molar ratios of 1:3 (17:50 mM), 1:1 (50 mM) and 3:1 were utilized as model systems. (2) To investigate the effect of initial solute concentration on the crystallization of glycine and phosphate buffer salt during lyophilization. Phosphate buffered glycine solutions were placed in a custom-designed sample cell for freeze-drying. The sample cell, covered with a stainless steel dome with a beryllium window, was placed on a stage capable of controlled cooling and vacuum drying. The samples were cooled to -50 C and annealed at -20 C. They underwent primary drying at -25 C under vacuum until ice sublimation was complete and secondary drying from 0 to 25 C. At different stages of the freeze-drying cycle, the samples were periodically exposed to synchrotron X-ray radiation. An image plate detector was used to obtain time-resolved two-dimensional SXRD patterns. The ice, {beta}-glycine and DHPD phases were identified based on their unique X-ray peaks. When the solutions were cooled and annealed, ice formation was followed by crystallization of disodium hydrogen phosphate dodecahydrate (DHPD). In the primary drying stage, a significant increase in DHPD crystallization followed by incomplete dehydration to amorphous disodium hydrogen phosphate was evident. Complete dehydration of DHPD occurred during secondary drying. Glycine crystallization was inhibited throughout freeze-drying when the initial buffer concentration (1:3 glycine to buffer) was higher than that of glycine. A high-intensity X-ray diffraction method was developed to monitor the phase transitions during the entire freeze-drying cycle. The high sensitivity of SXRD allowed us to monitor all the crystalline phases simultaneously. While DHPD crystallizes in frozen solution, it dehydrates incompletely during primary drying and completely during secondary drying. The impact of initial solute concentration on the phase composition during the entire freeze-drying cycle was quantified.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Deep Underground Neutrino Experiment: The precision era of neutrino physics

The last decade was remarkable for neutrino physics. In particular, the phenomenon of neutrino flavor oscillations has been firmly established by a series of independent measurements. All parameters of the neutrino mixing are now known, and we have the elements to plan a judicious exploration of new scenarios that are opened by these recent advances. With precise measurements, we can test the three-neutrino paradigm, neutrino mass hierarchy, and charge conjugation parity (CP) asymmetry in the lepton sector. The future long-baseline experiments are considered to be a fundamental tool to deepen our knowledge of electroweak interactions. The Deep Underground Neutrino Experiment (DUNE) will detect a broadband neutrino beam from Fermilab in an underground massive liquid argon time-projection chamber at an L/E of about 103 km GeV-1 to reach good sensitivity for CP-phase measurements and the determination of the mass hierarchy. The dimensions and the depth of the far detector also create an excellent opportunity to look for rare signals like proton decay to study violation of the baryonic number, as well as supernova neutrino bursts, broadening the scope of the experiment to astrophysics and associated impacts in cosmology. In this paper, we discuss the physics motivations and the main experimental features of the DUNE project required to reach its scientific goals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Parallel multiplex laser feedback interferometry

We present a parallel multiplex laser feedback interferometer based on spatial multiplexing which avoids the signal crosstalk in the former feedback interferometer. The interferometer outputs two close parallel laser beams, whose frequencies are shifted by two acousto-optic modulators by 2Ω simultaneously. A static reference mirror is inserted into one of the optical paths as the reference optical path. The other beam impinges on the target as the measurement optical path. Phase variations of the two feedback laser beams are simultaneously measured through heterodyne demodulation with two different detectors. Their subtraction accurately reflects the target displacement. Under typical room conditions, experimental results show a resolution of 1.6 nm and accuracy of 7.8 nm within the range of 100 μm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Designing ITER motional Stark effect line shift (MSE-LS) spectrometers

As a part of ITER beam aided diagnostics, the design of Motional Stark Effect (MSE) diagnostic observing the emission from the Balmer-α line is underway. The physics of Stark splitting shows that the Stark manifold is polarization dependent, and the energy splitting results in a line shift proportional to the electric field. Due to the challenges of maintaining the calibration of the plasma facing mirrors in ITER, the conventional MSE polarimetry measurement technique is replaced with a spectral approach that is deemed more favorable in the ITER environment. The MSE line shift (LS) diagnostic is designed to quantify the Lorentz electric field magnitude by measuring the Stark manifold using visible spectroscopy. In the presence of large magnetic fields and high energy heating beams of 1 MeV, the expected Stark splitting is much larger than in typical devices. The MSE-LS design has unique challenges requiring careful consideration and modeling of its viewing geometry and photon budget. The MSE-LS approach on ITER is promising but has stringent demands on the allowable errors for the statistical and systematic fitting uncertainties. In this study, a full system model and numerical simulations of data for each sightline are completed. For a range of optical transmission fractions, photon noise analysis is conducted to determine the statistical uncertainties. This provides guidance on the spectrometer throughput, dispersion at the detector, optics, and other design choices. A conceptual design of a high throughput spectrometer with a volume phase transmission grating is presented.

Instruments & Instrumentation↗

Long-term variation of the solar diurnal anisotropy of galactic cosmic rays observed with the Nagoya multi-directional muon detector

We analyze the three-dimensional anisotropy of the galactic cosmic ray (GCR) intensities observed independently with a muon detector at Nagoya in Japan and neutron monitors over four solar activity cycles. We clearly see the phase of the free-space diurnal anisotropy shifting toward earlier hours around solar activity minima in A > 0 epochs, due to the reduced anisotropy component parallel to the mean magnetic field. This component is consistent with a rigidity-independent spectrum, while the perpendicular anisotropy component increases with GCR rigidity. We suggest that this harder spectrum of the perpendicular component is due to contribution from the drift streaming. We find that the bi-directional latitudinal density gradient is positive in the A > 0 epoch, while it is negative in the A < 0 epoch, in agreement with the drift model prediction. The radial density gradient of GCRs, on the other hand, varies with a ∼11 yr cycle with maxima (minima) in solar maximum (minimum) periods, but we find no significant difference between the radial gradients in the A > 0 and A < 0 epochs. The corresponding parallel mean free path is larger in A < 0 than in A > 0. We also find, however, that the parallel mean free path (radial gradient) appears to persistently increase (decrease) in the last three cycles of weakening solar activity. We suggest that simple differences between these parameters in A > 0 and A < 0 epochs are seriously biased by these long-term trends.

79 ASTRONOMY AND ASTROPHYSICS↗

Micromegas chambers for the experiment ATLAS at the LHC (A Brief Overview)

The increase in luminosity and energy of the Large hadron collider (LHC) in the next upgrade (Phase-1) in 2018–2019 will lead to a significant increase in radiation load on the ATLAS detector, primarily in the areas close to the interaction point of the LHC proton beams. One of these regions is the Small Wheel of the ATLAS Muon Spectrometer. It is planned to be replaced with the New Small Wheel that will have Micromegas chambers as main coordinate detectors. The paper gives an overview of all existing types of Micromegas detectors with special focus on the Micromegas chambers for the ATLAS detector upgrade.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First demonstration of a sub-keV electron recoil energy threshold in a liquid argon ionization chamber

We describe the first demonstration of a sub-keV electron recoil energy threshold in a dual-phase liquid argon time projection chamber. This is an important step in an effort to develop a detector capable of identifying the ionization signal resulting from nuclear recoils with energies of order a few keV and below. We obtained this result by observing the peaks in the energy spectrum at 2.82 keV and 0.27 keV, following the K- and L-shell electron capture decay of 37 Ar, respectively. The 37 Ar source preparation is described in detail, since it enables calibration that may also prove useful in dark matter direct detection experiments. An internally placed 55 Fe x-ray source simultaneously provided another calibration point at 5.9 keV. We discuss the ionization yield and electron recombination in liquid argon at those three calibration energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Impacts of simulated herbivory on volatile organic compound emission profiles from coniferous plants

The largest global source of volatile organic compounds (VOCs) in the atmosphere is from biogenic emissions. Plant stressors associated with a changing environment can alter both the quantity and composition of the compounds that are emitted. This study investigated the effects of one global change stressor, increased herbivory, on plant emissions from five different coniferous species: bristlecone pine ( Pinus aristata ), blue spruce ( Picea pungens ), western redcedar ( Thuja plicata ), grand fir ( Abies grandis ), and Douglas-fir ( Pseudotsuga menziesii ). Herbivory was simulated in the laboratory via exogenous application of methyl jasmonate (MeJA), a herbivory proxy. Gas-phase species were measured continuously with a gas chromatograph coupled to a mass spectrometer and flame ionization detector (GC–MS–FID). Stress responses varied between the different plant types and even between experiments using the same set of saplings. The compounds most frequently impacted by the stress treatment were alpha-pinene, beta-pinene, 1,8-cineol, beta-myrcene, terpinolene, limonene, and the cymene isomers. Individual compounds within a single experiment often exhibited a different response to the treatment from one another.

54 ENVIRONMENTAL SCIENCES↗

Conditions Databases at FNAL

Conditions databases is an important class of database applications where the database is used to record the state of a set of quantities as a function of observation time. Conditions databases are used in Hight Energy Physics to record the state of the detector apparatus during data taking, and then to use the data during the event reconstruction and analysis phases. At FNAL, we have a set of 3 different conditions database products, Minerva Conditions DB, ConDB and UConDB, which cover the whole range of the use cases presented by the FNAL experiments. These products have common features such as conditions data representation model, data version control, ability to restore the database to a previous state, scalable web service data access interface. In the paper, we will present the common features of the products, common solutions used to build them and also the differences between the products and their target use cases.

Mandrichenko, Igor V.↗

Optimizing Performance of a Charge-Sensitive Amplifier for the LEGEND-200 Experiment

The observation of neutrinoless double-beta decay would provide evidence for the proposition that neutrinos are their own antiparticle, a property that is not prescribed in the Standard Model. The proposed Large Enriched Germanium Experiment for Neutrinoless double beta Decay (LEGEND) will search for this decay mode in 76Ge by deploying high-purity germanium (HPGe) detectors enriched in this isotope. The signal from two hundred kilograms of HPGe detectors will be fed to low-radioactivity, charge-sensing amplifiers (CSA) deployed in the first phase of the LEGEND experiment: LEGEND-200. We optimized the performance of the CSA in different test conditions by varying the operating parameters (including voltages supplied to the active components of the CSA) and measured the properties of the amplified waveform, such as rise time, dynamic range, and electronic noise. The optimized parameters lead to waveforms with the following characteristics: 90 ns rise time, a dynamic range from 0-10 MeV, and noise of 620 keV (FWHM) at a total power consumption of 156 mW in liquid nitrogen. The optimization process will continue as the circuit is integrated with other components of the experiment.

Lawley, Gannon↗

Photoproduction of Cascade Baryons Using the GlueX Detector at Jefferson Laboratory

Multi-strange baryons have played an important role in understanding the strong interaction. Despite their importance to advancing quantum chromodynamics (QCD), little is known about such hyperons due to the lack of a strange probe. Almost all knowledge of Cascade baryons today stems from kaon-nucleon interactions in bubble chamber experiments performed in the 1960s and 1970s. The 1980s saw advancement in electronics and computational resources allowing for higher statistic experiments such as the MultiParticle Spectrometer (MPS) at Brookhaven National Laboratory. From these previous experiments, the octet and decuplet ground states, Xi(1320) and Xi(1530) respectively, were well established with known properties and four excited states were well established. This research uses the GlueX experiment at Jefferson Laboratory to extend photoproduction cross section measurements for Xi(1320)- to higher beam energies to further understand the production mechanism, as well as to search for the first excited Cascade resonance observation in photoproduction through the decay Xi-* -> K-Lambda. The GlueX Spectrometer is a nearly hermetic detector used to study exclusive photoproduction reactions with photon beam energies up to 12 GeV. The first phase of GlueX running has recently been completed. Preliminary results for the total cross section and differential cross sections in terms of momentum transfer -t are shown within. Additionally, the first observation of an excited Cascade baryon, in particular Xi(1820)-, is shown.

Ernst, Ashley↗