Magnetic bearing element with adjustable stiffness
A compact magnetic bearing element is provided which is made of permanent magnet discs configured to be capable of the adjustment of the bearing stiffness and levitation force over a wide range.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
A compact magnetic bearing element is provided which is made of permanent magnet discs configured to be capable of the adjustment of the bearing stiffness and levitation force over a wide range.
We have developed a prototype rotating-permanent magnet sextupole lens (named rot-PMSx) for more efficient experiments with neutron beams in time of flight (ToF) mode. This lens can modulate the focusing strength over range 1.5 x 10{sup 4} T/m{sup 2} {le} g' {le} 5.9 x 10{sup 4} T/m{sup 2}. Synchronization between the modulation and the beam pulse produces a focused beam without significant chromatic aberration. We anticipate that this lens could be utilized in focusing small angle neutron scattering (SANS) instruments for novel approach to high resolution SANS. We carried out experiments testing the principle of this lens at the very cold neutron (VCN) beamline (PF2) at Institut Laue-Langevin (ILL), France. The focused beam image size at the detector was kept constant at the same beam size as the source ({approx} 3 mm) over a wavelength range of 30 {angstrom} {le} {lambda} {le} 48 {angstrom} in focal length of {approx} 1.14 m. The flux gain was about 12 relative to a beam without focusing, and the depth of focus was quite large. These results show the good performance of this lens and the system. Thereupon we have demonstrated the performance of this test bed for high resolution focusing of VCN-SANS for a well-studied softmatter sample; a deuterium oxide solution of Pluronic F127, an (PEO){sub 100}(PPO){sub 65}(PEO){sub 100} tri-block copolymer in deuterium oxide. The results of the focusing experiment and the focusing VCN-SANS are presented.
MnAl is a promising rare-earth free permanent magnet for technological use. We have examined the effects of consolidation by back-pressure, assisted equal channel angular extrusion processing on mechanically-milled, gas-atomized Mn-46% at. Al powder. X-ray diffraction showed both that the extruded rod consisted mostly of metastable tau phase, with some of the equilibrium gamma(2) and beta phases, and that it largely retained the as-milled nanostructure. Magnetic measurements show a coercivity of <= 4.4 kOe and a magnetization at 10 kOe of <= 40 emu/g. In addition, extrusions exhibit greater than 95% of the theoretical density. This study opens a new window in the area of bulk MnAl magnets with improved magnetic properties for technological use.
Purpose: To explore the advantages of magnetic focusing for small volume proton irradiations and the potential clinical benefits for radiosurgery targets. The primary goal is to create narrow elongated proton beams of elliptical cross section with superior dose delivery characteristics compared to current delivery modalities (eg, collimated beams). In addition, more general beam shapes are also under investigation. Methods: Two prototype magnets consisting of 24 segments of samarium-cobalt (Sm2Co17) permanent magnetic material adhered into hollow cylinders were manufactured for testing. A single focusing magnet was placed on a positioning track on our Gantry 1 treatment table and 15 mm diameter proton beams with energies and modulation relevant to clinical radiosurgery applications (127 to 186 MeV, and 0 to 30 mm modulation) were delivered to a terminal water tank. Beam dose distributions were measured using a PTW diode detector and Gafchromic EBT2 film. Longitudinal and transverse dose profiles were analyzed and compared to data from Monte Carlo simulations analogous to the experimental setup. Results: The narrow elongated focused beam spots showed high elliptical symmetry indicating high magnet quality. In addition, when compared to unfocused beams, peak-to-entrance depth dose ratios were 11 to 14% larger (depending on presence or extent of modulation), and minor axis penumbras were 11 to 20% smaller (again depending on modulation) for focused beams. These results suggest that the use of rare earth magnet assemblies is practical and could improve dose-sparing of normal tissue and organs at risk while delivering enhanced dose to small proton radiosurgery targets. Conclusion: Quadrapole rare earth magnetic assemblies are a promising and inexpensive method to counteract particle out scatter that tends to degrade the peak to entrance performance of small field proton beams. Knowledge gained from current experiments will inform the design of a prototype treatment nozzle that incorporates similar focusing magnets. This project was sponsored in part by funding from the Department of Defense (DOD# W81XWH-BAA-10-1)
The overarching project objective is to demonstrate the feasibility of using an innovative PowerTake-Off (PTO) Module in Columbia Power's utility-scale wave energy converter (WEC). The PTO Module uniquely combines a large-diameter, direct-drive, rotary permanent magnet generator; a patent-pending rail-bearing system; and a corrosion-resistant fiber-reinforced-plastic structure
The splitter/merger section of the CBETA project [1] consists of 4 beam lines as shown in Fig. 1. Two of the functions of the splitter’s/merger’s lines is to match the beam parameters at the exit of the Energy Recovery Linac (ERL) to the beam parameters at the entrance of the Fixed Field Alternating Gradient (FFAG) arc, and also place the reference particles of the beam bunches at the entrance of the FFAG arc on specified trajectories according to their energies. In this technical note we are presenting results from the 2D and 3D electromagnetic analysis of the S4.BEN01 magnet which is one of the dipole magnets of the 150 MeV line of the splitter/merger. In particular we present results from two designs of the S4.BEN01 magnet, one based on iron dominated current-excited magnet, and the other design based on Halbach-type permanent magnet. An evaluation of the two designs will be given in the section under “conclusion”.
These 2D transverse force calculations were done for the following Halbach magnet types in the CBETA design as it currently stands (an implementation of the April 10, 2017 lattice). These magnets are made out of two longitudinally-stacked layers of permanent magnet blocks.
Recent theoretical advances and molecular-dynamic estimates of the dielectric constant of water have extended the HKF model for aqueous solution chemistry up to 6.0 gigapascals (GPa), which are conditions well beyond the capabilities of conventional NMR spectroscopy (Pan et al., 2013; Sverjensky et al., 2014, see also Wasserman and others, 1995). These developments provide strong motivation to design a simple NMR probe that allows experiments on solutions, at high resolution, to pressures of a few GPa (Pautler et al., 2014; Ochoa et al., 2015; 2016). Here we describe the performance of a compact NMR probe that can reach several GPa pressures. The probe is made by placing a solenoid microcoil inside of a standard piston-cylinder device used in solid-state physics. High pressures are achieved in the sample by applying force to a coaxial piston. Early designs of the probe, although useful, were limited in sample size to ~10-15μL. Here we describe modifications that allow greatly improved resolution and sensitivity, including 1H-1H NMR correlation spectroscopy, on solutions at 2.8 GPa pressure. Sample sizes can be expanded if, instead of a standard NMR spectrometer that is built around a superconducting magnet, one employs a magnetic-resonance imaging (MRI) system that is built around a permanent magnet. The MRI systems can apply larger magnetic field gradients than conventional spectrometers, and thus have more robust shimming capability, which is needed because of the juxtaposition of different alloys in the pressure cell. More importantly, these systems can have magnetic fields that are oriented perpendicular to the magnet bore, which allows rotation of the coil within the axis of the pressure cell to increase sample volumes and pressure. Sensitivity is improved by replacing the traditional, but reduced-volume, closed sample container mounted in the center of the NMR detection coil with an open NMR coil that dangles freely in solution, thus making the sample solution itself the pressure-transmission fluid. The efficacy of these modifications are demonstrated by measuring 1 H NMR spectra for ethyl alcohol and ethyl alcohol/methyl alcohol mixtures at pressures up to 2.8 GPa. As a result, further developments are discussed that will allow geochemists to acquire aqueous solution NMR spectra at higher 3-4 GPa pressures.
A small high resolution paramagnetic susceptibility thermometer was developed using a GdCl3 paramagnetic salt. The device uses a SQUID magnetometer to determine the temperature dependent magnetization of the salt in a magnetic field. The required magnetic field is provided by a pair of small SmCo permanent magnet disks situated inside the thermometer housing. This eliminates the use of a heavy charging solenoid in a conventional SQUID based magnetic thermometer system using a flux tube. This thermometer can resolve approximately 10(exp -9)K near the liquid-gas critical point of The (approx. 3.31K). The drift in the thermometer is less than 2 x 10(exp -13) K/s. This light weighted thermometer (approx. 7 g) is a candidate for use in future International Space Station flight low temperature experiments.
The Inductrack magnetic levitation system, developed at the Lawrence Livermore National Laboratory, is being studied for its possible use for launching rockets. Under NASA sponsorship, a small model system is being constructed at the Laboratory to pursue key technical aspects of this proposed application. The Inductrack is a passive magnetic levitation system employing special arrays of high-field permanent magnets (Halbach arrays) on the levitating carrier, moving above a "track" consisting of a close-packed array of shorted coils with which are interleaved with special drive coils. Halbach arrays produce a strong spatially periodic magnetic field on the front surface of the arrays, while canceling the field on their back surface. Relative motion between the Halbach arrays and the track coils induces currents in those coils. These currents levitate the carrier cart by interacting with the horizontal component of the magnetic field. Pulsed currents in the drive coils, synchronized with the motion of the carrier, interact with the vertical component of the magnetic field to provide acceleration forces. Motional stability, including resistance to both vertical and lateral aerodynamic forces, is provided by having Halbach arrays that interact with both the upper and the lower sides of the track coils. In its completed form the model system that is under construction will have a track approximately 100 meters in length along which the carrier cart will be propelled up to peak speeds of Mach 0.4 to 0.5 before being decelerated. Preliminary studies of the parameters of a full-scale system have also been made. These studies address the problems of scale-up, including means to simplify the track construction and to reduce the cost of the pulsed-power systems needed for propulsion.
In this article, we present a new analysis method applied to revitalize permanent magnet Compton spectrometers used to measure photon energy spectra in the MeV range. The inversion of the measured electron distribution to determine the original photon distribution is achieved via a method of consistent coupled radiation transport and magnetic field mapping of the input photon spectra to the measured electron distribution. The method of linear least squares was used to perform the unfolding of the electron distribution to the initial photon spectra, without any assumptions made regarding the electron distribution. We present an application of this method to data from a nominal 19.4 MeV flash radiographic source (the first axis of the Dual Axis Radiographic Hydro-Test Facility) capable of generating 500 R @ 1 m in ~60 ns and a medical therapy source (a Scanditronix M22, Microtron) capable of variable energies with nominal endpoints of 6, 10, 15, and 20 MeV and an output of ~1000–2000 R/min @ 1 m. The results provide agreement between the modeled and unfolded experimentally measured photon spectra as quantified by statistical tests, from 1.5 to 20 MeV. Experimental results are presented as well as a discussion of the novel MCNP6-based simulations and methods for reconstruction of the spectra.
The Cornell-BNL ERL Test Accelerator (CBETA) has been designed, constructed, and commissioned in a collaboration between Cornell and Brookhaven National Laboratory (BNL). It focuses on energy-saving measures in accelerators, including permanent magnets, energy recovery, and superconductors; it has thus been referred to as a green accelerator. CBETA has become the world's first Energy Recovery Linac (ERL) that accelerates through multiple turns and then recovers the energy in superconducting radiofrequency (SRF) cavities though multiple decelerating turns. The energy is then available to accelerate more beam. It has also become the first accelerator that operates 7 beams in the same large-energy aperture Fixed Field Alternating-gradient (FFA) lattice. The FFA is constructed of permanent combined function magnets and transports energies of 42, 78, 114, and 150 MeV simultaneously. Accelerator physics lessons from the commissioning period will be described and applications of such an accelerator from hadron cooling to EUV lithography and from nuclear physics to a compact Compton source will be discussed.
We report on persistent field in quasi-permanent magnets of high temperature superconductors. Magnets composed of irradiated Y(1+)Ba2Cu3O7 trapped field Bt = 1.52 T at 77 K and 1.9 T at lower temperature. However, the activation magnet limited Bt at lower temperature. We present data on Jc(H,T) for unirradiated materials, and calculate Bt at various T. Based upon data at 65 K, we calculate Bt in unirradiated single grains at 20 K and find that 5.2 T will be trapped for grain diameter d about 1.2 cm, and 7.9 T for d = 2.3 cm. Irradiated grains will trap four times these values.
Magnetic anisotropy is essential for many applications of ferromagnetic/ferrimagnetic materials, including permanent magnets and magnetic recording media. Attempts have been made recently to build up 3-D nanoparticle and quantum dot assemblies, however, it is not understood yet if a nanoparticle assembly can possess high magnetic anisotropy with low anisotropic materials. In this article, we report our discovery of high magnetic anisotropy resulted from Fe 3 O 4 nanoparticle chains. We started with closely-packed nanoparticle assemblies of spherical Fe 3 O 4 nanoparticles that exhibit low magnetocrystalline anisotropy and shape anisotropy, and corresponding negligible coercivity. When the nanoparticle assemblies are compressed under pressure, they form bundles or arrays that consist of Fe 3 O 4 chains with a length scale of several hundred nanometers. Magnetic measurements show that these Fe 3 O 4 chain arrays possess a high uniaxial magnetic anisotropy (K eff ~ 2.9×10 5 J/m 3 ) and significant magnetic coercivity. Our simulations reveal that interparticle magnetic dipolar interactions contribute to this type of superstructure magnetic anisotropy. This study demonstrates the feasibility and approaches to create “patterned” high magnetic anisotropy in nanoparticle superstructures/assemblies.
Magnetic anisotropy is a key feature of rare earth materials from permanent magnets to heavy fermions. Here we explore the complex interplay of Kondo physics and anisotropy, and their effect on different experimental probes of magnetic anisotropy in a minimal 𝐽=3/2 Anderson impurity model using the numerical renormalization group. While anisotropy suppresses Kondo screening, virtual valence fluctuations enhance the anisotropy. We find distinct renormalization of the magnetic anisotropy measured via dynamical spin response (inelastic neutron scattering) versus electronic excitations in the impurity spectral function (resonant inelastic x-ray and scanning tunneling spectroscopy). The two measurement types have different responses and dependencies on the temperature and Kondo scales.
A promising technique for measuring single electron spins is magnetic resonance force microscopy (MRFM), in which a microcantilever with a permanent magnetic tip is resonantly driven by a single oscillating spin. The most effective experimental technique is the oscillating cantilever-driven adiabatic reversals (OSCAR) protocol, in which the signal takes the form of a frequency shift. If the quality factor of the cantilever is high enough, this signal will be amplified over time to the point where it can be detected by optical or other techniques. An important requirement, however, is that this measurement process occurs on a time scale that is short compared to any noise which disturbs the orientation of the measured spin. We describe a model of spin noise for the MRFM system and show how this noise is transformed to become time dependent in going to the usual rotating frame. We simplify the description of the cantilever-spin system by approximating the cantilever wave function as a Gaussian wave packet and show that the resulting approximation closely matches the full quantum behavior. We then examine the problem of detecting the signal for a cantilever with thermal noise and spin with spin noise, deriving a condition for this to be a useful measurement.
UC Davis was funded to explore the combination of beat-wave excitation and laser scattering to make completely non-invasive determination of local plasma conditions. This involves the use of two high frequency mm-wave sources of differing frequencies (the pump waves) to excite plasma waves at the difference of the frequencies, which is known as the beat frequency. The difference frequency or the frequency of the beat wave is chosen so that we produce plasma waves whose fluctuating electron density is a sensitive function of plasma parameters at the location where the source waves overlap. This fluctuation can be detected from outside the plasma, by measuring the deflection of a probe beam directed at the overlap region between the two pump waves (i.e., collective scattering). This work is an extension of mm-wave frequencies of a 10 GHz beat-wave experiment conducted on the DDT toroidal device (see Fig. 1) in a magnetized plasma where the excited Langmuir wave is replaced by the magnetized upper hybrid wave. Here, two high power (> 1 kW) ~94 GHz pump sources will be employed to match the upper hybrid resonance. The primary envisioned experiment is to drive the electron Bernstein wave (EBW) in the interior of a magnetized plasma. The EBW is a hot-plasma electrostatic wave, which cannot propagate in vacuum. Roots of the EBW dispersion relation occur at frequencies slightly higher than harmonics of the electron cyclotron frequency. Use of the EBW has particular advantages for measuring plasma magnetic field in plasmas with relatively high density and low magnetic field, as is the case in spherical tokamaks. This is the “over dense” condition of future efficient high beta magnetic confinement fusion reactors such as the spherical tokamak (STs). The overarching goal of the proposed project is to demonstrate beat wave EBW excitation in low density and temperature parameters that are directly scalable to over-dense spherical tokamaks such as NSTX or MAST, where measurement of magnetic field by electron cyclotron emission (ECE) is experimentally complex, and requires models of plasma profiles in order to interpret results. In such experiments, availability of point measurements of magnetic field strength provided by a beat-wave diagnostic would serve as a powerful independent check on the ECE results, serving to validate the assumed profiles and wave-propagation models used. The first step was to assemble/modify the target chamber in which the beat-wave plasma experiments will take place. Here, the target chamber of the CTIX compact-toroid (spheromak) injector was chosen. At the time that the proposal was submitted, the aim was to conduct the experiments in the CTIX experimental facilities located at the Livermore campus of UC Davis using microwave/mm-wave equipment brought from the main campus., However, by the time DoE funds for this project were awarded, the CTIX experimental facilities located at the Livermore campus of UC Davis were in the process of being shut down due to the closure of the Livermore campus by Lawrence Livermore National Laboratory (LLNL). Consequently, the equipment needed for this project was crated up and shipped from Livermore to Davis as part of the laboratory shutdown after space on campus was secured and College of Engineering approval secured. Once it arrived in Davis on December 20, 2018, work on the project began in earnest with the initial efforts directed toward developing a new plasma target source. Because of the shutdown of the CTIX facility, the scope of the project thus had to be reduced due to the abbreviated amount of time allocated to the project once the shutdown/move had been completed. Chamber modifications have been completed, including the fabrication and installation of a 38 GHz interferometer, as described in Sec. 3. The thermionic plasma source has been tested and characterized. The magnetic field required for the EBW experiments will be generated by permanent magnets mounted on plates positioned above and below the chamber. Magnetic simulations have been performed, and show that a 3-ring magnet arrangement on each plate, with a plate separation of 50 cm, is required to achieve the ~100 G uniform magnetic field in the interaction region that we feel is necessary to ensure good EBW coupling. We proved unable to successfully revive either of Prof. Luhmann’s two high power (≥20 kW) 94 GHz millimeter-wave sources after their extended time in storage and decided to postpone further efforts and concentrate on slightly lower power sources. Consequently, we were successful in reviving a ~2 kW extended klystron amplifier (EIK), which together with a ~2 kW extended interaction oscillator (EIO) will provide the two pump sources required for the project. Safe operation of the EIO requires extensive modifications to one of Prof. Luhmann’s pulse modulators - these modulator modifications are ongoing, which has unfortunately delayed the planned beat-wave experiments. Details of this work are provided in Sec. 3. Even though project funding has now ended, we still plan to proceed to complete the EIO pulse modulator modifications, install the two ~94 GHz pump wave sources on the target chamber, and conduct unmagnetized tests of the beat-wave concept which involve coupling to unmagnetized electron plasma waves rather than magnetized EBWs. Should these experiments prove successful, we plan to submit a follow-up proposal for additional funding which would allow us to undertake the magnetized EBW experiments.
An improved compact design for a superconducting magnetic suspension and balance system for an 8 ft. x 8 ft. transonic wind tunnel is developed. The original design of an MSBS in NASA Cr-3802 utilized 14 external superconductive coils and a superconductive solenoid in the airplane test model suspended in a wind tunnel. The improvements are in the following areas: test model solenoid options, dynamic force limits on the model, magnet cooling options, structure and cryogenic designs, power supply specifications, and cost and performance evaluations. The improvements are: MSBS cost reduction of 28%, weight; reduction of 43%, magnet system ampere-meter reduction of 38%, helium liquifier capacity reduction by 33%, magnet system stored energy reduction by 55%, AC loss to liquid helium reduced by 76%, system power supply reduced by 68%, test coil pole strength increased by 19%, wing magnetization increased by 40%, and control frequency limit increased by 200% from 10 Hz to 30 Hz. The improvements are due to: magnetic holmium coil forms in the test model, better rare earth permanent magnets in the wings, fiberglass-epoxy structure replacing stainless steel, better coil configuration, and new saddle roll coil design.