Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PENETRATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Linear simulation of magnetohydrodynamic plasma response to three-dimensional magnetic perturbations in high-β P plasmas

In this work, we report the numerical analyses of linear magnetohydrodynamics (MHD) plasma response to applied three-dimensional magnetic perturbations (MPs) in a joint DIII-D/EAST collaboration on high-β P (poloidal beta) plasmas, utilizing the extended-MHD code M3D-C1, with the purpose of realizing a better understanding of the existing experiment in which the n=3 MPs were applied to such high-β P plasmas attempting to control large amplitude type-I ELMs. Such high-β P plasmas obtained at the DIII-D tokamak feature an upper-biased double null configuration, a high edge safety factor q 95 ~6.4, and a stable internal transport barrier (ITB) leading to relatively high core pressures. Single-fluid simulations show that the plasma response to n=3 MPs, including both non-resonant/kinking and resonant components, is significantly weaker than that to n=1 or 2 MPs. To survey the impact of q 95 on plasma response to applied MPs, the SEGWAY (Self-consistent Equilibrium Generating Workflow for AnalYsis) module, developed in the OMFIT integrated modelling framework, is employed to generate a series of equilibria with a wide range of q 95 while other key parameters including the normalized beta, electron density at pedestal top, and plasma shape are kept fixed. Compared to the vacuum response, single-fluid M3D-C1 simulations predict a much more significant decrease of resonant plasma response to the applied n=3 MPs at the maximum penetration radii as q 95 increases. In contrast to single-fluid simulation results showing resonant penetration occurs only near the pedestal top where the E×B toroidal rotation frequency is zero, two-fluid simulations show two comparable resonant penetrations locating near the pedestal top and the ITB foot, where the perpendicular electron rotation frequency is zero. Such resonant field penetration near the ITB foot may be responsible for the observed formation of a staircase structure in both electron density and temperature profiles and thereby a considerable deterioration of global plasma performance when MPs are applied in high-β P plasmas. Motivated by this numerical work, we provide some ideas for the future research, with the purpose of realizing effective ELM control in such high-β P plasmas on the DIII-D and EAST devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of ionization peak location on measured opaqueness in DIII-D H-mode plasmas

This study investigates the relationship between electron pedestal density and the location of the ionization peak on neutral penetration in DIII-D H-mode plasmas, utilizing a database of Lyman-α emission measurements. The high electron density leads to neutrals being ‘screened’ and the ionization front being pushed out into the Scrape-Off Layer (SOL). This is also referred to as the neutral opaqueness, which is heuristically expected to scale with edge plasma density and machine size. However, at lower electron pedestal density, the penetration depth of the neutrals varies, and measured opaqueness deviates from the heuristic scaling. The database reveals that at low density, when the ionization peak is located in SOL region, the linear relationship between the electron density and neutral penetration holds. However, when the peak is located inside the separatrix, the penetration of the neutrals (λ n 0 ) is much wider ~3.0–3.5 cm, breaking the heuristic opaqueness approximation. These findings provide valuable insights into fueling efficiency and plasma behavior, with implications for Fusion Pilot Plants where high pedestal densities are anticipated and where the neutral opaqueness behaves like its heuristic approximation. This analysis offers a framework to refine neutral opaqueness approximations, enhancing the predictive capability for advanced tokamak operations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Machine Learning-Based PV Reserve Determination Strategy for Frequency Control on the WECC System

Frequency control from photovoltaic (PV) power plants has great potential to address the frequency response challenge of the power system with high penetrations of renewable generation. Using model-based approaches to determine the optimal PV headroom reserve, however, requires significant online computation and is intractable for an interconnection level system. This paper proposes a machine learning based strategy, that is suitable for real-time operation, to determine the optimal PV reserve for frequency control. The proposed machine learning algorithm is trained and tested on 1,987 offline simulations of a 60% renewable penetration Western Electricity Coordinating Council (WECC) system. Furthermore, the proposed reserve determination strategy is applied on a realistic 1-day operation profile of the WECC system and demonstrates a savings of more than 40% PV headroom compared to a conservative approach. It is evident that the proposed strategy can efficiently and effectively determine the optimal PV frequency control reserve for realistic interconnection systems.

frequency control↗

Assessing the Implications of Automated Merging Control in a Mixed and Heterogeneous Traffic Environment

Previous efforts to explore the implications of partial market penetration of connected and automated vehicles (CAVs) show a consensus on the benefits of higher market penetration rates (MPR) of vehicles enabled with connectivity and/or automation. There is, however, a level of uncertainty regarding the effects of lower market penetration rates and the consideration of heterogeneous vehicle fleets. Using VISSIM to perform microscopic traffic simulation and, vehicle simulation models, we assess the impacts of different CAVs market penetration rates on fuel consumption considering a heterogeneous traffic environment. The results show that the fuel efficiency benefits of optimal coordination control are maximized in moderate congested scenarios when the CAVs MPR exceeds 40%.

Rios Torres, Jackeline↗

Arbitrage and Capacity Firming in Coordination with Day-Ahead Bidding of a Hybrid PV Plant

A hybrid PV plant (HPP) combines a photovoltaic (PV) plant with a battery energy storage system (BESS), which is considered a promising step towards the future of renewable power plants by the U.S. Department of Energy. When the renewable penetration reaches a significant level, a hybrid PV plant can bid in as a controllable thermal plant in the future electricity market. In this study, a bidding and BESS scheduling model is proposed for the HPP. The robust optimization (RO) technique has been utilized to identify the worst-case scenario of uncertainties during the bidding process. To address the overly conservative issue of the single-stage RO, we have decoupled the BESS schedule for arbitrage and PV capacity firming by a two-stage RO formulation. By comparing the output of single-stage RO and two-stage RO, the two-stage RO bids and schedules in a more aggressive manner, which increases the income of HPP. Also, the penalty of under-generation is considered in our model so that the day-ahead bidding decision and arbitrage schedules can be adjusted based on the potential UNDER-GENERATION penalty. Because the proposed model is non-convex and contains multi-stages, the Column-and-Constraint Generation (C&CG) algorithm is applied to the model as the solution. The proposed model has shown better economic performance compared to a state-of-art single-stage bidding method in case studies.

BESS scheduling↗

Thermal Runaway of Li-Ion Cells: How Internal Dynamics, Mass Ejection, and Heat Vary with Cell Geometry and Abuse Type

Thermal runaway of lithium-ion batteries can involve various types of failure mechanisms each with their own unique characteristics. Using fractional thermal runaway calorimetry and high-speed radiography, the response of three different geometries of cylindrical cell (18650, 21700, and D-cell) to different abuse mechanisms (thermal, internal short circuiting, and nail penetration) are quantified and statistically examined. Correlations between the geometry of cells and their thermal behavior are identified, such as increasing heat output per amp-hour (kJ Ah −1 ) of cells with increasing cell diameter during nail penetration. High-speed radiography reveals that the rate of thermal runaway propagation within cells is generally highest for nail penetration where there is a relative increase in rate of propagation with increasing diameter, compared to thermal or internal short-circuiting abuse. For a given cell model tested under the same conditions, a distribution of heat output is observed with a trend of increasing heat output with increased mass ejection. Finally, internal temperature measurements using thermocouples embedded in the penetrating nail are shown to be unreliable thus demonstrating the need for care when using thermocouples where the temperature is rapidly changing. All data used in this manuscript are open access through the NREL and NASA Battery Failure Databank.

25 ENERGY STORAGE↗

The Roles of Westward-Propagating Waves and the QBO in Limiting MJO Propagation

Abstract A recent study categorized the Madden–Julian oscillation (MJO) during boreal winter season into four types called stand, jump, slow, and fast MJO. This study focuses on the stand and jump MJO. Based on whether their convection penetrates the Maritime Continent (MC), stand and jump MJOs are seen as non-penetrating (NP) MJOs, while the other two are seen as eastward-penetrating (EP) MJOs. Results reveal the relative roles of the westward-propagating wave (WPW), as well as the QBO and ENSO, in limiting MJO propagation. Lack of the premoistening over the southern sea surface of the MC stops NP MJO from penetrating the MC. The active convection of the WPWs hinders the descending branch of the NP MJO circulation and therefore leads to the insufficient meridional advective moistening over the southern sea surface of the MC. The independent convection over the Pacific for jump MJOs is influenced by a combined effect of the QBO and ENSO. The tropopause instability induced by the MJO is found to significantly decouple from its convection over the Pacific in westerly QBO (QBOW) winters more than in easterly QBO (QBOE) winters. For jump MJOs, the independent convection over the central Pacific comes from local WPWs whose amplification and further development into deep convection are correlated to jump the MJOs’ decoupled tropopause instability. For stand MJOs, however, the seasonal-mean La Niña–like cool SST anomalies weaken the WPW activity over the central Pacific and confine WPWs within the western Pacific. Therefore, the decoupled tropopause instability of stand MJOs is out phase of WPWs and fails to induce an independent convection over the central Pacific.

54 ENVIRONMENTAL SCIENCES↗

Cellular response of keratinocytes to the entry and accumulation of nanoplastic particles

Plastic accumulation in the environment is rapidly increasing, and nanoplastics (NP), byproducts of environmental weathering of bulk plastic waste, pose a significant public health risk. Particles may enter the human body through many possible routes such as ingestion, inhalation, and skin absorption. However, studies on NP penetration and accumulation in human skin are limited. Loss or reduction of the keratinized skin barrier may enhance the skin penetration of NPs. The present study investigated the entry of NPs into a human skin system modeling skin with compromised barrier functions and cellular responses to the intracellular accumulations of NPs. Two in vitro models were employed to simulate human skin lacking keratinized barriers. The first model was an ex vivo human skin culture with the keratinized dermal layer (stratum corneum) removed. The second model was a 3D keratinocyte/dermal fibroblast cell co-culture model with stratified keratinocytes on the top and a monolayer of skin fibroblast cells co-cultured at the bottom. The penetration and accumulation of the NPs in different cell types were observed using fluorescent microscopy, confocal microscopy, and cryogenic electron microscopy (cryo-EM). The cellular responses of keratinocytes and dermal fibroblast cells to stress induced by NPs stress were measured. The genetic regulatory pathway of keratinocytes to the intracellular NPs was identified using transcript analyses and KEGG pathway analysis. The cellular uptake of NPs by skin cells was confirmed by imaging analyses. Transepidermal transport and penetration of NPs through the skin epidermis were observed. According to the gene expression and pathway analyses, an IL-17 signaling pathway was identified as the trigger for cellular responses to internal NP accumulation in the keratinocytes. The transepidermal NPs were also found in co-cultured dermal fibroblast cells and resulted in a large-scale transition from fibroblast cells to myofibroblast cells with enhanced production of α-smooth muscle actin and pro-Collagen Ia. The upregulation of inflammatory factors and cell activation may result in skin inflammation and ultimately trigger immune responses.

36 MATERIALS SCIENCE↗

Least-Cost Pathways for India's Electric Power Sector

The Government of India has a target of deploying 175 GW from renewable energy by 2022 and 40% of electricity capacity from renewable energy by 2030 and has indicated that ambitions for 2030 could be higher. Rapid changes in technology costs and performance could drive further deployment of wind and solar capacity beyond these policy targets. Increased deployment of variable renewable energy (VRE) raises new questions for power system planning regarding the optimal siting of generation capacity, trade-offs between generation and transmission infrastructure, and system flexibility needs. This study aims to evaluate least-cost pathways for India's electric power system over the period 2017-2047. Uniquely, this work considers an expanded planning horizon and range of scenarios not previously analyzed in national planning studies in India. The data collection and model design processes undertaken for this study provides a framework for recurring planning studies. This study finds anticipated changes in electricity demand and component costs can drive a significant shift in India's future electricity supply and how this system will be operated. In the Base scenario, the share of generation from VRE reaches 54% by 2047. Reducing the capital cost of wind has a larger impact on VRE penetration than reducing the capital cost of solar PV or battery storage. In the lowest wind cost scenario (40% capital cost decline by 2047 relative to the Base scenario), the penetration of VRE in the generation mix reaches 722%, exceeding the penetration levels achieved when the cost of battery storage or solar PV are reduced by an even greater 50%. In a future system with high penetrations of RE, capacity additions are driven by the coincidence of demand and RE generation rather than peak demand alone. This study finds the system could have surplus capacity during the peak demand months of July–September because this period corresponds to periods with high wind speeds and more wind generation available to meet peak demand. By contrast, new capacity is needed to meet demand during moderate demand months of October–November when output from wind plants falls more than 75% nationally compared to the previous two months. Finally, the success for gas for electricity production may depend on cost competitiveness rather than fuel availability. Increasing the amount of gas available for electricity production had no significant impact on the capacity or generation mix by 2047, as determined from a scenario that significantly increases fuel availability throughout the planning horizon. In fact, over 80% of new gas fuel available for the power sector remains unused. This suggests the high cost of gas plant operations relative to other technologies may constrain the expansion of gas generation in India more than fuel availability.

14 SOLAR ENERGY↗

Managing Solar Photovoltaic Integration in the Western United States Appendix: Reference and High Solar Photovoltaic Scenarios for Three Regions [Slides]

This slide deck is an appendix to a paper series that examines potential challenges related to planning future power systems with higher solar photovoltaic (PV) penetrations. The series uses the western U.S. power system for these investigations because it is a region the authors and their colleagues have already extensively studied. We are therefore well-suited to analyze even higher PV penetrations and then examine the results in multiple models to determine whether our current approaches are missing key details that only emerge at higher PV penetrations. This deck details the systems underlying those analyses and how they were modeled using the Resource Planning Model (RPM), a capacity expansion modeling tool. We examine both Western Interconnection-wide and regional results for three regions in the Western U.S. with significantly different existing power systems and connections to neighboring regions; this provides a more balanced picture as to how power systems with high PV penetration might emerge in different contexts and what the resulting grid challenges, if any, might be.

14 SOLAR ENERGY↗

Tamper-Indicating Enclosures with Visually Obvious Tamper Response (Final Project Report)

Sandia National Laboratories is developing a new method for detecting penetration of tamper - indicating enclosures (TIEs). This method incorporates the use of "bleeding" materials (analogous to visually obvious, colorful bruised skin that doesn't heal) into the design of TIEs. As designed, it will allow inspectors to use simple visual observation to detect attempts to penetrate the external surfaces of a TIE, without providing adversaries the ability to repair damage. A material of this type can enhance tamper indication of current TIEs used to support treaty verification regimes. Current TIE inspections are time - consuming and rely on subjective visual assessment by an inspector, equipment such as eddy current or camera devices, or involve approaches that may be limited due to application environment. The complexities and requirements that volumetric sealing methods (or TIEs) must address are: (1) enclosures that are non - standard in size/shape; (2) enclosures that may be inspectorate - or facility - owned; (3) finding tamper attempts that are difficult and time consuming for an inspector to locate; (4) enclosures that are reliable and durable enough to survive the conditions that exist in the operating environment (including facility handling); and (5) methods that prevent adversaries from repairing penetrations. Early project R&D [1] focused on encapsulated transition metals. Due to the challenges associated with the transition metal - based approach, a mitigation approach was investigated resulting in two separate research paths — one that involves fabricating custom TIE molds that meet the specific (size and shape) needs of safeguards equipment a nd one that can be deployed as a sprayed on or painted coating to an existing TIE or surface. The "custom mold" approach is based on creating thin layers of materials that , when penetrated, expose an inner material to O 2 which causes an irreversible color change. The "in-situ coating" approach is based on applying a sensor solution containing color changing microcapsules that bleed when the microcapsule is ruptured. The anticipated benefits of this work are passive, flexible, scalable, robust , cost-effective TIEs with visually obvious responses to tamper attempts. This provides more efficient and effective monitoring , as inspectors will require little or no additional equipment and will be able to detect tamper without extensive time - consuming visual examination. Applications include custom TIEs (cabinets , equipment enclosures or seal bodies ), or spray-coating/painting onto facility-owned items, walls or structures, or circuit boards. The paper describes research and testing completed to-date on the method and integration of select system components.

36 MATERIALS SCIENCE↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Creating an Inter-Tribal Technical Assistance Network in the Northwest Arctic

The US Department of Energy-Office of Indian Energy's (DOE-IE) support for NANA's establishment of an Inter-Tribal Assistance Network in the Northwest Arctic was a ground-breaking effort that led to many individual community successes and a regional escalation of clean energy for our tribes. Before this grant award was initiated, high penetration renewable-diesel hybrid systems were primarily aspirational. Now, after five years of intensive technical assistance and multi-institution collaboration and funding, the NANA Region has three high penetration solar-wind-battery-diesel hybrid systems and one solar-battery-diesel hybrid system fully operational with diesel-off operation occurring regularly; another solar-battery-diesel hybrid system fully funded with an RFP for construction targeted for 2023; a current grant application that was awarded to begin the final design process for solar-battery-diesel hybrid systems for four other villages in the region; and initial funding to begin a high penetration wind-battery-diesel system for the remaining village in the region. Clearly, our goal to demonstrate and replicate high penetration renewable hybrid technology has been accomplished and is increasing in scale and pace.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Smart Refractory Sensors Development for Corrosion and Erosion Monitoring in High Temperature Systems

To optimize the operation and functioning of high temperature systems such as slagging gasifiers, coal boilers and glass/steel melters, it is important to monitor corrosion and erosion of refractory used in such systems. Corrosion test strategies are generally based on continuous gravimetric and chemical reactivity monitoring at operational temperatures (750°-1500°C). Both thermocouples and failure sensors and arrays would be useful to monitor the health of any refractory or coatings in these systems. Many of such type of sensors are installed into the systems through open access ports within the refractory; however, there are some disadvantages of this approach where corrosive/erosive gas and molten materials can penetrate and compromise the system. The current work presents the development and performance demonstration of smart refractory with embedded high temperature sensors such as thermocouples, thermistors, and various spallation/crack monitoring sensors, which may be used within a variety of refractory brick in different high temperature processes and applications. The main feature of this technology is that electroceramic based sensors are embedded into smart refractory without significantly impact to the intrinsic properties of the refractory. This technology circumvents the need to insert an isolated monolithic, stand-alone sensor into the refractory via an access port. This technological approach guarantees the integrity and the chemical stability of the materials used in the sensor fabrication within the harsh environment and does not introduce molten material (such as slag) penetration pathways within the refractory. One interesting and important aspect of this innovation is that these embedded sensors can be used to in situ monitoring processes such as chemical reactions and at the same time give information and a deeper understanding of the corrosion and erosion process of the refractory within the system. As stated above, the objective of our work is to develop high-temperature sensors composed of electroceramic materials that are chemically stable at high temperatures (750°-1500°C) and high pressures (up to 1000 psi) that can be used in monitoring corrosion and erosion process in refractory used in high energy systems. The high-temperature sensors investigated in this work were composed of various oxide composites directly embedded into the refractory oxides. The composites used for this work were synthesized by a mixed-oxide route. Metal oxides were inserted within a matrix material composed of refractory oxides (Al2O3, ZrO2, etc.). The physical and electrical properties were specifically manipulated by altering the level of percolation of the conductive species (metal oxides) within the refractory constituent (refractory oxide). Prior to the development of the high-temperature sensors, the oxides composites developed in this study were sintered up to 1600°C under oxidizing atmosphere in order to investigate densification, microstructural evolution, phase development, and their thermoelectrical performance as a function of the composition. The 4-point DC conductivity measurements were performed between 100°-1500°C. The sensors were fabricated from the composite materials by 3D-printing or screen-printing methods into the refractory brick during the consolidation process. An example of one of these embedded sensors consisted of an electroceramic-based thermocouple fabricated with two separate oxide composite compositions which were patterned to produce a couple within the interior of a refractory matrix. The thermocouple successfully displayed thermoelectric voltage trend (as a function of temperature), and the voltage was 220.0 mV around 1400 °C. Corrosion tests on the refractory embedded sensors were performed. To evaluate corrosion in the refractory brick an in-house glass composition was prepared and pressed into pellets and delivered into a pre-cut cavity in the brick. Corrosion experiments results showed the glass penetrated the brick over a 90 h period, and the penetration of the glass through the brick could be monitored by both an amperometric and voltametric based sensor. With this experiment, it was demonstrated that the embedded sensor could dynamically monitor the corrosion process.

20 FOSSIL-FUELED POWER PLANTS↗

An RTDS-Based Testbed for Investigating the Impacts of Transmission-Level Disturbances on Solar PV Operation

The increasing penetration of renewable energy resources such as solar and wind via power electronic inverters is challenging grid dynamics, as well as grid planning, operation, and protection. Recently, the North American Electric Reliability Corporation (NERC) has reported a series of similar events of the unintended loss of solar generation in Southern California over a large geographic area following the transmission-level disturbances. These events highlight the importance of understanding the characteristics of the transmission-side disturbances propagating into the distribution systems and their impacts on the operation of inverter-based resources. In this paper, a real-time electromagnetic simulation testbed is constructed for real-time electromagnetic simulations to generate realistic transmission-level disturbances and investigate their impacts on the solar PV operation under different fault types and locations, solar penetration levels, and loading levels. Through the simulation analysis and grid strength assessment, it is found that the grid strength at points of integration (POIs) of solar PVs significantly affects the transient stability of solar generators. Particularly, undesirable transient stability events are more likely to occur at the weak POIs following the transmission-level disturbances. Moreover, undesirable transient stability events become severer when the transmission-level disturbance is closer to the weak POIs or the disturbances become more serious. Additionally, the impact of the transmission-level disturbances on the solar PVs at the weak POIs exacerbate with the increasing solar penetration levels and loading levels. Thus, it is important to study and develop new technologies for grid planning, operation, and protection in weak grid conditions to address the emerging issues of integrating the high penetration of solar PVs and other IBRs.

14 SOLAR ENERGY↗

Flight investigation of the response of a helicopter to the trailing vortex of a fixed-wing aircraft

A flight investigation was conducted to quantitatively determine the response of a medium-weight helicopter to the trailing-vortex system of a fixed-wing aircraft. Flight tests and analytical tools were both utilized in the investigation. The flight tests involved an extensively instrumented UH-1H helicopter and a C-54 aircraft. Penetrations of the vortex system by the UH-1H were made at the following nominal conditions: the C-54 flew at 5500 feet altitude at a nominal gross weight of 58,000 pounds and an indicated airspeed of 115 knots in a cruise configuration. The UH-1H, nominally 7200 pounds gross weight, flew at 60 knots indicated airspeed during the penetrations at separation distances of 6.64 nautical miles to 0.42 nautical mile between aircraft. In general, the data analyzed for the above tests indicated that no unsafe penetration occurred. Further, penetrating vehicle attitude changes and structural loads were nominal. In addition, the response of the helicopter did not change appreciably with decreased separation distance.

Mantay, W. R.↗

Lithospheric instabilities

In this paper we define a mantle geoid. This is the height that hot solid mantle rock from the asthenosphere would attain if it were not confined by the lithosphere. The mantle geoid lies 3.25 km below the hydrogeoid (sea level). Hot mantle rock cannot entirely penetrate the continental lithosphere. One consequence of this partial penetration is rifting; as a result of rifting an accreting plate margin may be created. Hot mantle rock from the asthenosphere can penetrate through the oceanic lithosphere if the sea floor lies below the mantle geoid. Penetration of the oceanic lithosphere by this solid mantle rock is a necessary condition for the initiation of subduction. We argue that the same processes that are associated with rifting in continental lithosphere will be associated with behind arc spreading and the initiation of subduction in the oceanic lithosphere.

Turcotte, D. L.↗

Meteoroid bumper experiment on Explorer 46

The effectiveness of a meteoroid bumper in reducing meteoroid penetrations is discussed. The bumper reduced the penetration flux by a factor of 30 and demonstrated a weight savings of a factor of 6.9 in the material needed to resist meteoroid penetration. The method of calculating the penetration flux recommended in the NASA space vehicle design criteria for meteoroid damage assessment was found to be very conservative, and changes are suggested. The optimum distribution of material between a bumper and the main wall is discussed.

Humes, D. H.↗