Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optics and Optical Instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Benchmark Analysis for the Optical Dilatometry Method Using Silicon Carbide Temperature Monitors

The main objective of this project was to conduct a benchmark analysis for the optical dilatometry method by using NSUF’s SiC temperature monitors: two (2) SiC temperature monitors provided by NSUF’s BSU-8242 experiment and two (2) SiC temperature monitors provided by NSUF’s GE-Hitachi experiment. Per the BSU-8242 experiment, KGT-3597 and KGT-3591 had a design temperature of 400°C and an exposure of 3 dpa. Per the GE-Hitachi experiment, KGT-3341 and KGT-3336 had a design temperature of 290°C +/- 50°C and an exposure of 0.5–1 dpa. The KGT-3336 SiC monitor was split into two pieces during the decontamination process, making the dilatometry method the only way to analyze both those pieces. The BSU-8242 monitors revealed peak irradiation temperatures under the design temperature, and the GE-Hitachi monitors revealed peak irradiation temperatures within the design temperature range. The optical dilatometry method measured the peak irradiation temperature of BSU-8242 KGT-3597 to be 330°C, while the resistivity method measured the peak irradiation temperature of BSU-8242 KGT-3591 to be 320°C +/- 20°C. The optical dilatometry method measured the peak irradiation temperatures of the pieces of GE-Hitachi KGT-3336 to be 260°C (for the larger piece) and 220°C (for the smaller piece), while the resistivity method measured the peak irradiation temperature of GE-Hitachi KGT-3341 to be 300°C, with an accuracy range of -50°C to +20°C. Both methods of SiC temperature monitor analysis produced very similar peak irradiation temperatures for each pair of SiC passive monitors from the two experiments, BSU-8242 and GE-Hitachi. The results show dilatometry method to be a reliable and less time-intensive process for determining irradiation temperatures from passive SiC thermometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sub-keV design for the National Ignition Facility’s soft x-ray Opacity Spectrometer (OpSpec) and expansion plans for time-resolved measurements

When compared with the National Ignition Facility’s (NIF) original soft x-ray opacity spectrometer, which used a convex cylindrical design, an elliptically shaped design has helped to increase the signal-to-noise ratio and eliminated nearly all reflections from alternate crystal planes. The success of the elliptical geometry in the opacity experiments has driven a new elliptical geometry crystal with a spectral range covering 520–1100 eV. When coupled with the primary elliptical geometry, which spans 1000–2100 eV, the new sub-keV elliptical geometry helps to cover the full iron L-shell and major oxygen transitions important to solar opacity experimentation. The new design has been built and tested by using a Henke x-ray source and shows the desired spectral coverage. Additional plans are underway to expand these opacity measurements into a mode of time-resolved detection, ~1 ns gated, but considerations for the detector size and photometrics mean a crystal geometry redesign. Here, the new low-energy geometry, including preliminary results from the NIF opacity experiments, is presented along with the expansion plans into a time-resolved platform.

47 OTHER INSTRUMENTATION↗

Digital autofocusing of a coded-aperture Laue diffraction microscope

To provide optimal depth resolution with a coded-aperture Laue diffraction microscope, an accurate position of the coded-aperture and its scanning geometry need to be known. However, finding the geometry by trial and error is a time-consuming and often challenging process because of the large number of parameters involved. In this paper, we propose an optimization approach to automate the focusing process after data is collected. Here we demonstrate the robustness and efficiency of the proposed approach with experimental data taken at a synchrotron facility.

47 OTHER INSTRUMENTATION↗

The next-generation magnetic recoil spectrometer (MRSnext) on OMEGA and NIF for diagnosing ion temperature, yield, areal density, and alpha heating

The next-generation magnetic recoil spectrometer (MRSnext) is being designed to replace the current MRS at the National Ignition Facility and OMEGA for measurements of the neutron spectrum from an inertial confinement fusion implosion. The MRSnext will provide a far-superior performance and faster data turnaround than the current MRS systems, i.e., a 2× and 6× improvement in energy resolution at the NIF and OMEGA, respectively, and 20× improvement in data turnaround time. The substantially improved performance of the MRSnext is enabled by using electromagnets that provide a short focal plane (12–16 cm) and unprecedented flexibility for a wide range of applications. In addition to being able to measure neutron yield, apparent ion temperature, areal density, and plasma-flow velocity over a wide range of yields, the NIF MRSnext will be able to directly, uniquely assess the alpha heating of the fuel ions through measurements of the alpha knock-on tail in the neutron spectrum. The goal is to implement a radiation-hard electronic detection system capable of providing rapid data acquisition and analysis. The development of the MRSnext will also set the foundation for the more advanced, time-resolving MRSt and serve as a testbed for its implementation on the NIF.

47 OTHER INSTRUMENTATION↗

Photon-Counting Interferometry to Detect Geontropic Space-Time Fluctuations with GQuEST

The gravity from the quantum entanglement of space-time (GQuEST) experiment uses tabletop-scale Michelson laser interferometers to probe for fluctuations in space-time. We present a practicable interferometer design featuring a novel photon-counting readout method that provides unprecedented sensitivity, as it is not subject to the interferometric standard quantum limit. We evaluate the potential of this design to measure space-time fluctuations motivated by recent “geontropic” quantum gravity models. The accelerated accrual of Fisher information offered by the photon-counting readout enables GQuEST to detect the predicted quantum gravity phenomena within measurement times at least 100 times shorter than equivalent conventional interferometers. The GQuEST design, thus, enables a fast and sensitive search for signatures of quantum gravity in a laboratory-scale experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Inner Shell Spectroscopy beamline at NSLS-II: a facility for in situ and operando X-ray absorption spectroscopy for materials research

The Inner Shell Spectroscopy (ISS) beamline on the 8-ID station at the National Synchrotron Light Source II (NSLS-II), Upton, NY, USA, is a high-throughput X-ray absorption spectroscopy beamline designed for in situ, operando, and time-resolved material characterization using high monochromatic flux and scanning speed. This contribution discusses the technical specifications of the beamline in terms of optics, heat load management, monochromator motion control, and data acquisition and processing. Results of the beamline tests demonstrating the quality of the data obtainable on the instrument, possible energy scanning speeds, as well as long-term beamline stability are shown. The ability to directly control the monochromator trajectory to define the acquisition time for each spectral region is highlighted. Examples of studies performed on the beamline are presented. The paper is concluded with a brief outlook for future developments.

36 MATERIALS SCIENCE↗

Low Threshold, Long Wavelength Interband Cascade Lasers With High Voltage Efficiencies

Here, we report on the substantial advancement of long wavelength InAs-based interband cascade lasers (ICLs) utilizing advanced waveguides formed from hybrid cladding layers and targeting the 10-12 µm wavelength region. Modifications in the hole injector have improved carrier transport in these ICLs, resulting in significantly reduced threshold voltages (V th ) as low as 3.62 V at 80 K. Consequently, much higher voltage efficiencies were observed, peaking at about 73% at 10.3 µm and allowing for large output powers of more than 100 mW/facet. Also, low threshold current densities (J th ) of 8.8 A/cm 2 in cw mode and 7.6 A/cm 2 in pulsed mode near 10 µm were observed; a result of adjustments in the GaInSb hole well composition intended to reduce the overall strain accumulation in the ICL. Furthermore, an ICL from the second wafer operating at a longer wavelength achieved a peak voltage efficiency of 57% at 11.7 µm, with a peak output power of more than 27 mW/facet. This ICL went on to lase beyond 12 µm in both cw and pulsed modes, representing a new milestone in long wavelength coverage for ICLs with the standard W-QW active region.

47 OTHER INSTRUMENTATION↗

Tomographic FLEET with a wedge array for multi-point three-component velocimetry

Femtosecond laser electronic excitation tagging (FLEET) velocimetry is an important diagnostic technique for seedless velocimetry measurements particularly in supersonic and hypersonic flows. Typical FLEET measurements feature a single laser line and camera system to achieve one-component velocimetry along a line, although some multiple-spot and multiple-component configurations have been demonstrated. In this work, tomographic imaging is used to track the three-dimensional location of many FLEET spots. A quadscope is used to combine four unique views onto a single high-speed image intensifier and camera. Tomographic reconstructions of the FLEET emission are analyzed for three-component velocimetry from multiple FLEET spots. Glass wedges are used to create many (nine) closely spaced FLEET spots with less than 10% transmission losses. These developments lead to a significant improvement in the dimensionality and spatial coverage of a FLEET instrument with some increases in experimental complexity and data processing. Multiple-point three-component FLEET velocimetry is demonstrated in an underexpanded jet.

47 OTHER INSTRUMENTATION↗

Two Year Cosmology Large Angular Scale Surveyor (CLASS) Observations: Long Timescale Stability Achieved with a Front-end Variable-delay Polarization Modulator at 40 GHz

The Cosmology Large Angular Scale Surveyor (CLASS) is a four-telescope array observing the largest angular scales (2≲ ℓ ≲ 200) of the cosmic microwave background (CMB) polarization. These scales encode information about reionization and inflation during the early universe. The instrument stability necessary to observe these angular scales from the ground is achieved through the use of a variable-delay polarization modulator as the first optical element in each of the CLASS telescopes. Here, we develop a demodulation scheme used to extract the polarization timestreams from the CLASS data and apply this method to selected data from the first 2 yr of observations by the 40 GHz CLASS telescope. These timestreams are used to measure the 1/f noise and temperature-to-polarization (T → P) leakage present in the CLASS data. We find a median knee frequency for the pair-differenced demodulated linear polarization of 15.12 mHz and a T → P leakage of <3.8 × 10 -4 (95% confidence) across the focal plane. We examine the sources of 1/f noise present in the data and find the component of 1/f due to atmospheric precipitable water vapor (PWV) has an amplitude of 203 ± 12 µK RJ $\sqrt{{s}}$ for 1 mm of PWV when evaluated at 10 mHz; accounting for ~17% of the 1/f noise in the central pixels of the focal plane. In conclusion, the low levels of T → P leakage and 1/f noise achieved through the use of a front-end polarization modulator are requirements for observing of the largest angular scales of the CMB polarization by the CLASS telescopes.

79 ASTRONOMY AND ASTROPHYSICS↗

In-line measurements of below-the-surface food deformation during drying with an interference-based optical fiber strain sensor

Real-time measurements of food deformation are important for quality control in drying, yet they pose significant challenges. In this study, we developed an interference-based optical fiber strain sensor to enable in-line, continuous, below-the-surface strain measurements in drying of soft food samples. Compared to a strain resolution of 8 × 10 -4 at zero strain and 7.2 × 10 -3 at 0.20 strain reported in our previously published work, the present study achieves markedly improved resolutions of 1.3 × 10 -4 at zero strain and 7.8 × 10 -4 at 0.25 strain, which strains are the lower and higher boundaries of the dynamic range, respectively. This nearly order-of-magnitude improvement is attributed to the unique interference-based sensing mechanism, no need for calibration to convert optical signals to strain, and the system-design-enabled immunity to fiber-disk misalignments and light source intensity fluctuations. To demonstrate the in-line process monitoring, deformation measurements of fresh banana slices and sugar cookie doughs were carried out in a benchtop oven and an industrial-scale hot-air pilot dryer, respectively. In both dryers, strain measurements were continuously measured during the whole drying process at various depths and radii below the sample surfaces, with the strains up to 25%. Computer vision was used only in the benchtop drying to confirm the faithfulness of the fiber sensor measurements and cannot provide below-the-surface measurements. The measured spatiotemporal deformation allowed us to confirm the shell-hardening effect and to determine the speed and location of large deformation changes in the whole drying process, the latter of which is related to the sample cracking. To the best of the authors’ knowledge, this study is the first to report on an interferometry-based fiber sensor to measure food deformation. This sensor and the sensing mechanism have high potential for real-time process monitoring and control to prevent over-drying or cracking during drying processes.

47 OTHER INSTRUMENTATION↗

Wavefront preserving X-ray optics for Synchrotron and Free Electron Laser photon beam transport systems

We report in the last two decades, after the first light from the new Free Electron Lasers, either in the UV (FLASH and FERMI@Elettra) or X-ray (LCLS and SACLA), more and more new diffraction limited sources have been either constructed or planned. Third generation storage rings are upgraded to provide a more collimated, brighter, and coherent light for the next generation experimental techniques. X-ray optics are the bridge between the light sources and the experimental stations. They are the key to the success of advanced experiments but also the potential bottleneck preventing the exploitation of the full characteristics of the source. The beam degradation originated by any mirror defect (either from mirror polishing or from contamination) is amplified with a coherent source. Delivering diffraction-limited spots, including the option for variable spot sizes in and out of focus, requires the control of the surface of the optics at the 1 nm rms level, if not better. At LCLS, only very recently an almost perfectly uniform beam out of focus has been obtained in the hard X-rays. It has been obtained after two 1-m long mirrors with 0.5 nm rms shape precision (after installation). Those mirrors were not readily available just a decade ago. But, thanks to the pioneering work performed at the Osaka University, those optics are now commercially available with arbitrary tangential profiles. This new generation of mirrors permits achieving unprecedented results. However, they do not remove all road blocks to a perfect photon transport system. Instead, they highlighted the critical importance of mirror mounting, handling of the thermal deformation, and the need of advanced diagnostics to properly exploit all the new potentiality of these optics. Besides the need of “perfect” mirrors, other aspects of the beamline design and elements may impact the quality of the beam in the experimental station, from the lack of blaze gratings to the need of advanced simulation tools, just to cite two. In this article, after a brief historical excursus, we will present the current state of the art of mirrors, gratings, crystals, lenses, diagnostics, and simulation tools. The main problems yet to solve and a look ahead at what would be achievable in the next decade will give the reader an idea on the search for an almost ideal photon transport system and how the path toward experiments, not conceivable today, will unfold.

47 OTHER INSTRUMENTATION↗

NLR CSP Optical Facilities: Illuminating the Path Forward Through Innovation and Impact: Agreement 38490

This initiative is a multi-faceted project at the National Laboratory of the Rockies (NLR) aimed at strengthening its Concentrating Solar Power (CSP) Optical Facilities to advance the development of low-cost, high-performance materials for solar and other applications. The project's strategy is built on three pillars: strategic stakeholder engagement, diligent facility maintenance and utilization, and the development of new research capabilities. The overarching goal is to ensure the facilities remain state-of-the-art resources for industry and academia, thereby accelerating the conversion of concentrated sunlight into energy. A key driver of the project is an international Advisory Board, which provides critical guidance on research priorities and industry needs, leading to new collaborations and secured funding. This external engagement, combined with proactive outreach to industry partners, ensures the lab's work remains aligned with real-world challenges, including materials durability and performance certification. Significant efforts in facility maintenance have addressed challenges with aging infrastructure. Notable achievements include the complete refurbishment of the hail-damaged Ultra-Accelerated Weathering System (UAWS) and the successful replacement of a failing 15-year-old Lambda 1050 spectrophotometer with a new-generation model, substantially upgrading material characterization capabilities. These maintenance activities were complemented by achieving a prestigious ISO 9001:2015 certification for the Advanced Optical Materials Labs, formally recognizing the quality and reliability of NLR's measurement capabilities. Despite these successes, challenges remain, including high demand for the High Flux Solar Furnace (HFSF) and intermittent failures of other key instruments. The project has delivered major advancements in research techniques and capabilities. At the Flatirons campus, a new indoor laboratory, was established to house advanced deflectometry and photogrammetry systems for heliostat characterization. For on-sun testing, a novel, actively cooled turning mirror was developed for the HFSF, enabling more realistic testing of particle receivers and components. A collaboration with Virginia Tech successfully demonstrated the high-temperature durability of a new solar absorber coating through extensive cyclic testing. Concurrently, new modeling took place to better predict material degradation on rough, fractal surfaces. In summary, this project has systematically enhanced NLR's CSP Optical Facilities through strategic upgrades, rigorous maintenance, and stakeholder-guided research. By overcoming equipment failures, budgetary constraints, and logistical hurdles, the project has reinforced NLR's role as a central hub for CSP innovation and materials testing. Future work will focus on securing diverse funding, expanding collaborations, and continuing to provide the critical infrastructure needed to accelerate the development and deployment of next-generation technologies.

14 SOLAR ENERGY↗

A versatile pressure-cell design for studying ultrafast molecular-dynamics in supercritical fluids using coherent multi-pulse x-ray scattering

Supercritical fluids (SCFs) can be found in a variety of environmental and industrial processes. They exhibit an anomalous thermodynamic behavior, which originates from their fluctuating heterogeneous micro-structure. Characterizing the dynamics of these fluids at high temperature and high pressure with nanometer spatial and picosecond temporal resolution has been very challenging. The advent of hard x-ray free electron lasers has enabled the development of novel multi-pulse ultrafast x-ray scattering techniques, such as x-ray photon correlation spectroscopy (XPCS) and x-ray pump x-ray probe (XPXP). These techniques offer new opportunities for resolving the ultrafast microscopic behavior in SCFs at unprecedented spatiotemporal resolution, unraveling the dynamics of their micro-structure. However, harnessing these capabilities requires a bespoke high-pressure and high-temperature sample system that is optimized to maximize signal intensity and address instrument-specific challenges, such as drift in beamline components, x-ray scattering background, and multi-x-ray-beam overlap. We present a pressure cell compatible with a wide range of SCFs with built-in optical access for XPCS and XPXP and discuss critical aspects of the pressure cell design, with a particular focus on the design optimization for XPCS.

47 OTHER INSTRUMENTATION↗

Diaboloidal mirrors: algebraic solution and surface shape approximations

A new type of optical element that can focus a cylindrical wave to a point focus (or vice versa) is analytically described. Such waves are, for example, produced in a beamline where light is collimated in one direction and then doubly focused by a single optic. A classical example in X-ray optics is the collimated two-crystal monochromator, with toroidal mirror refocusing. The element here replaces the toroid, and in such a system provides completely aberration free, point-to-point imaging of rays from the on-axis source point. We present an analytic solution for the mirror shape in its laboratory coordinate system with zero slope at the centre, and approximate solutions, based on bending an oblique circular cone and a bent right circular cylinder, that may facilitate fabrication and metrology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-cost, portable optical sensors for critical mineral prospecting and process monitoring

A combination of projected demand increases for economically critical minerals and a monopolistic global marketplace for these minerals has caused concern over supply chain vulnerabilities, which would impact energy, national defense, and advanced technology production. Domestic production of critical minerals is hindered by expensive and non-portable methods for analyzing metal concentration, which is vital both for resource prospecting and process monitoring. Here, a suite of luminescent materials along with portable instrumentation is presented for fluorescence-based detection of trace concentrations of critical minerals (cobalt, rare earth elements, and aluminum) as well as common gangue metals that are removed during processing (iron and aluminum). A metal-organic framework comprised of zinc, adenine, and trimesic acid immobilized on a fiber optic tip is capable of sensing part-per-billion concentrations of terbium, europium, dysprosium, and samarium through a sensitization approach, in which individual elements produce characteristic emission bands enabling multiple rare earths to be simultaneously detected and distinguished. A deep-UV light emitting diode is used as the excitation source, while a portable spectrometer is used to detect the emitted light. A similar optical set-up is coupled with two different carbon dot materials, which can detect low part-per-million concentrations of cobalt and iron in acidic environments. Metal-organic framework thin films comprised of copper and 2-aminoterephthalic acid are used in tandem with a portable optical set-up to further detect aluminum, with successful deployment in real fly ash leachates. Taken together, these technologies provide an inexpensive and sensitive path towards characterizing economically critical metals.

characterization and extraction of rare earth elem↗

Quiescent Host Galaxies of Extended Quasars Revealed by Spectrophotometric Decomposition

Previous works of low-redshift quasar host galaxies have focused on compact quasars and found that their host galaxies are mainly star-forming galaxies. Here, we present a study of host galaxies for quasars with extended morphologies in ground-based optical images. We select a sample of more than 1000 type 1 quasars at redshift 0.1 < z < 1 that are classified as extended objects by the Dark Energy Spectroscopic Instrument (DESI). Combining high-resolution spectra from DESI and high-quality images from Subaru Hyper Suprime-Cam, we develop a spectrophotometric decomposition technique to iteratively decompose each quasar into an active galactic nucleus (AGN) component and its host galaxy. The technique can effectively break the degeneracy between the AGN and host components and capture the host spectral features. Our results show that the host galaxies of most quasars have low star formation rates (SFRs) and low specific SFRs, indicating that they are quiescent galaxies. Many of them exhibit prominent post-starburst features with the existence of significant old stellar populations. These properties are quite different from the nature of compact quasars with star-forming host galaxies. In addition, the relation between the black hole mass and stellar mass for our sample is broadly consistent with the canonical local relations. This work is complementary to the previous studies and suggests that the host galaxies of low-redshift quasars are more diverse than was thought.

79 ASTRONOMY AND ASTROPHYSICS↗

Application and performance of the novel Elcomat 5000 autocollimator in slope-measuring profilometry of beamline optics

Autocollimators are used in profilometers for the precise form measurement of beam-shaping optics for synchrotron light sources and x-ray free-electron lasers. This application requires using an aperture stop, typically 2.5 mm in diameter, which limits the footprint of the autocollimator’s measuring beam on the optics to achieve a sufficiently high lateral resolution. Central to the development of profilometry has been the availability of commercial autocollimators, such as the Elcomat 3000 from Möller–Wedel Optical. Although autocollimators are generally not designed for use with small apertures, this device has proven capable and has become the de facto standard. Now that it has been replaced by the Elcomat 5000, we evaluate the performance of several autocollimators of this type at small apertures, including the characterization of instrument transfer functions with a chirped height profile. We demonstrate that the Elcomat 5000 is capable of repeatable angle measurements with a standard deviation of 0.014 arcsec at an aperture diameter of 1.6 mm, whereas the Elcomat 3000 achieves 0.03 arcsec at 2.5 mm, comparing models with modified reticle designs. Here, we also investigate the influence of optical aberrations of the autocollimator’s objective and their changes with the path length to the surface under test. We characterize the sensitivity of the angle measurement to changes in environmental parameters, in particular, barometric pressure. These efforts are aimed at approaching fundamental limits in the characterization of the shape of optical surfaces with autocollimator-based profilometers so that these are ready for characterizing the next generation of synchrotron and XFEL beamline optics.

angle metrology↗