Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Neutron imaging of inertial confinement fusion implosions

We review experimental neutron imaging of inertial confinement fusion sources, including the neutron imaging systems that have been used in our measurements at the National Ignition Facility. These systems allow measurements with 10 µm resolution for fusion deuterium–deuterium and deuterium–tritium neutron sources with mean radius up to 400 µm, including measurements of neutrons scattered to lower energy in the remaining cold fuel. These measurements are critical for understanding the fusion burn volume and the three-dimensional effects that can reduce the neutron yields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Making A Circular-Harmonic Filter

Optical image-correlating system made rotationally invariant. Experiment shows circular-harmonic filter generated optically. Hologram made by phase-shifted-double-exposure procedure. Filter used in optical image-recognition system based on correlation between target (image to be recognized) and matched spatial filter. In addition to usual invariance under translation of target, circular harmonic filter invariant under rotation of target; peak intensity of illumination at origin of correlation plane does not vary when target rotated about optical axis.

Cheng, Yeou Yen↗

4C 41.17 - A radio galaxy at a redshift of 3.8

Observations, comprising radio imaging at three frequencies, optical broadband and narrow-band imaging, optical spectroscopy, and K-band IR imaging, of a distant radio source, 4C 41.17, are presented. It is shown that 4C 41.17 is associated with an extended source of optical and IR emission at a redshift of 3.8. The morphological similarities between the radio source and the ionized gas and optical/IR continua suggest that the radio source is interacting vigorously with the galaxy. Various mechanisms for producing the optical/IR emission in 4C 41.17 are considered. It is concluded that a large fraction of the spectral energy distribution is from stars, and that the star formation induced by the radio source is the likely mechanism to account for the radio/optical alignment.

Chambers, K. C.↗

Optical Extinction-Based 3D Nano-Imaging of WS 2 on Gold

Broad band nano-extinction images recorded in the tip-enhanced optical spectroscopy geometry track the 3D topography of a single layer of WS 2 on Au substrate. The described nano-optical method is complementary to conventional AFM and offers additional information about the buried material-metal interface that is not accessible using conventional topographic imaging. Beyond 3D optical imaging, we observe large variations in the junction plasmon resonance on the nanoscale. The latter is important to understand and account for in tip-enhanced Raman and photoluminescence studies that target low-dimensional materials specifically. Further, our observations and (coherent) optical scattering-based method are also relevant to emerging efforts aimed at exploring strong coupling and Fano interferences in hybrid plasmonic-low dimensional quantum material systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Heliostat optical error inspection with polarimetric imaging drone

On a Concentrated Solar Power (CSP) field, optical errors have significant impacts on the collection efficiency of heliostats. Fast, cost-effective, labor-efficient, and non-intrusive autonomous field inspection remains a challenge. Approaches using imaging drone, i.e., Unmanned Aerial Vehicle (UAV) system integrated with high resolution visible imaging sensors, have been developed to address these challenges; however, these approaches are often limited by insufficient imaging contrast. Here, in this study, we report a polarimetry-based method with a polarization imaging system integrated on UAV to enhance imaging contrast for in-situ detection of heliostat mirrors without interrupting field operation. We developed an optical model for skylight polarization pattern to simulate the polarization images of heliostat mirrors and obtained optimized waypoints for polarimetric imaging drone flight path to capture images with enhanced contrast. The polarimetric imaging-based method improved the success rate of edge detections in scenarios which were challenging for mirror edge detection with conventional imaging sensors. We have performed field tests to achieve significantly enhanced heliostat edge detection success rate and investigate the feasibility of integrating polarimetric imaging method with existing imaging-based heliostat inspection methods, i.e., Polarimetric Imaging Heliostat Inspection Method (PIHIM). Our preliminary field test results suggest that the PIHIM hold the promise to enable sufficient imaging contrast for real-time autonomous imaging and detection of heliostat field, thus suitable for non-interruptive fast CSP field inspection during its operation.

CSP Field↗

Novel imaging technique for thermal neutrons using a fast optical camera

A novel imaging technique for thermal neutrons using a fast optical camera is presented. Thermal neutrons are reacted with 6 Lithium to produce a pair of 2.73 MeV tritium and 2.05 MeV alpha particles, which in turn interact in a thin layer of LYSO crystal scintillator to produce a localized flash of light. These photons are directed by a pair of lenses to a micro-channel plate intensifier, and its output is connected to the optical camera, TPX3CAM. The results from the camera are reconstructed through a custom algorithm. Various cutting parameters were found through data analysis to eliminate the background, and they were shown effective in matching the simulated rate of the neutron source. The system is fast with 40 ns decay time and allows free-space light collection, both vastly enhances flexibility of neutron detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of an automated imaging system for use in a space experiment

An experiment, occurring in an orbiting platform, examines the mass transfer across gas-liquid and liquid-liquid interfaces. It employs an imaging system with real time image analysis. The design includes optical design, imager selection and integration, positioner control, image recording, software development for processing and interfaces to telemetry. It addresses the constraints of weight, volume, and electric power associated with placing the experiment in the Space Shuttle cargo bay. Challenging elements of the design are: imaging and recording of a 200-micron-diameter bubble with a resolution of 2 microns to serve a primary source of data; varying frame rates from 500 per second to 1 frame per second, depending on the experiment phase; and providing three-dimensional information to determine the shape of the bubble.

Hartz, William G.↗

Performance Assessment of the Optical Transient Detector and Lightning Imaging Sensor: Clustering Algorithm - Part 2

We describe the clustering algorithm used by the Lightning Imaging Sensor (LIS) and the Optical Transient Detector (OTD) for combining the lightning pulse data into events, groups, flashes, and areas. Events are single pixels that exceed the LIS/OTD background level during a single frame (2 ms). Groups are clusters of events that occur within the same frame and in adjacent pixels. Flashes are clusters of groups that occur within 330 ms and either 5.5 km (for LIS) or 16.5 km (for OTD) of each other. Areas are clusters of flashes that occur within 16.5 km of each other. Many investigators are utilizing the LIS/OTD flash data; therefore, we test how variations in the algorithms for the event group and group-flash clustering affect the flash count for a subset of the LIS data. We divided the subset into areas with low (1-3), medium (4-15), high (16-63), and very high (64+) flashes to see how changes in the clustering parameters affect the flash rates in these different sizes of areas. We found that as long as the cluster parameters are within about a factor of two of the current values, the flash counts do not change by more than about 20%. Therefore, the flash clustering algorithm used by the LIS and OTD sensors create flash rates that are relatively insensitive to reasonable variations in the clustering algorithms.

Mach, Douglas M.↗

Path-Integrated Stereo X-Ray Digital Image Correlation: Resolving the Violation of Conservation of Intensity

In this study, x-ray imaging addresses many challenges with visible light imaging in extreme environments, where optical diagnostics such as digital image correlation (DIC) and particle image velocimetry (PIV) suffer biases from index of refraction changes and/or cannot penetrate visibly occluded objects. However, conservation of intensity—the fundamental principle of optical image correlation algorithms—may be violated if ancillary components in the X-ray path besides the surface or fluid of interest move during the test. The test series treated in this work sought to characterize the safe use of fiber-epoxy composites in aerospace and aviation industries during fire accident scenarios. Stereo X-ray DIC was employed to measure test unit deformation in an extreme thermal environment involving a visibly occluded test unit, incident surface heating to temperatures above 600°C, and flames and soot from combusting epoxy decomposition gasses. The objective of the current work is to evaluate two solutions to resolve the violation of conservation of intensity that resulted from both the test unit and the thermal chamber deforming during the test. The first solution recovered conservation of intensity by pre-processing the path-integrated X-ray images to isolate the DIC pattern of the test unit from the thermal chamber components. These images were then correlated with standard, optical DIC software. The second solution, called Path-Integrated Digital Image Correlation (PI-DIC), modified the fundamental matching criterion of DIC to account for multiple, independently-moving components contributing to the final image intensity. The PI-DIC algorithm was extended from a 2D framework to a stereo framework and implemented in a custom DIC software. Both solutions accurately measured the cylindrical shape of the undeformed test unit, recovering radii values of R = 76.20±0.12 mm compared to the theoretical radius of R theor = 76.20 mm. During the test, the test unit bulged asymmetrically as decomposition gasses pressurized the interior and eventually burned in a localized jet. Both solutions measured the heterogeneous radius of this bulge, which reached a maximum of approximately R = 91 mm, with a discrepancy of 2–3% between the two solutions. Two solutions that resolve the violation of conservation of intensity for path-integrated X-ray images were developed. Both were successfully employed in a stereo X-ray DIC configuration to measure deformation of an aluminum-skinned, fiber-epoxy composite test unit in a fire accident scenario.

47 OTHER INSTRUMENTATION↗

Optical-mechanical line-scan imaging process - Its information capacity and efficiency

Optical-mechanical line-scan techniques have been applied to earth satellite multispectral imaging systems. The capability of the imaging system is generally assessed by its information capacity. An approach based on information theory is developed to formulate the capacity of the line-scan process. Included are the effects of blurring of spatial detail, photosensor noise, aliasing, and quantization. The information efficiency is shown to be dependent on sampling rate, system frequency response shape, SNR, and quantization interval.

Huck, F. O.↗

Apparatus and method using a holographic optical element for converting a spectral distribution to image points

A holographic optical element transforms a spectral distribution of light to image points. The element comprises areas, each of which acts as a separate lens to image the light incident in its area to an image point. Each area contains the recorded hologram of a point source object. The image points can be made to lie in a line in the same focal plane so as to align with a linear array detector. A version of the element has been developed that has concentric equal areas to match the circular fringe pattern of a Fabry-Perot interferometer. The element has high transmission efficiency, and when coupled with high quantum efficiency solid state detectors, provides an efficient photon-collecting detection system. The element may be used as part of the detection system in a direct detection Doppler lidar system or multiple field of view lidar system.

McGill, Matthew J.↗

Microcomputer-based programmable optical signal processor

A microcomputer-based real-time programmable optical signal processing system utilizing a magneto-optic spatial light modulator (MOSLM) and a liquid crystal light valve (LCLV) is described. This system can perform a myriad of complicated optical operations, such as image correlation, image subtraction, and matrix multiplication. Its important asserts are its programmability and the capability of real-time addressing. These are important for telerobotic vision in space automation applications. Design specifications and suggestions for practical implementation of the system are discussed. Some preliminary experimental demonstrations are conducted to demonstrate applications of the proposed system to image correlation for optical pattern recognition, image subtraction for lC chip inspection, and matrix multiplication for optical computing.

Yu, F. T. S.↗

Optics-Free Chip-Scale Intraoperative Imaging Using NIR-Excited Upconverting Nanoparticles

Here we present an optics-free CMOS image sensor that incorporates a novel time-gated dual-photodiode pixel design to allow filter- and lens-less image acquisition of near-infrared-excited (NIR-excited) upconverting nanoparticles. Recent biomedical advances have highlighted the benefits of NIR excitation, but NIR interaction with silicon has remained a challenge, even with high-performance optical blocking filters. Using a secondary diode and a dual-photodiode design, this sensor is able to remove the 100s of mV of NIR background on pixels and bring it down to single-digit mV level, nearing its noise floor of 2.2 mV rms, not achievable with any optical filter. Non-linear effects of background cancellation using the diode pair has been mitigated using an initial one-time pixel-level curve fitting and calibration in a post-processing setting. This imager comprises a highly linear 11 fF metal-oxide-metal (MOM) capacitor and includes integrated angle-selective gratings to reject oblique light and enhance sharpness. Each pixel also includes two distinct correlated double sampling schemes, to remove low frequency flicker noise and systematic offset in the datapath. We demonstrate the performance of this imager using pulsed NIR-excited upconverting nanoparticles on standard United-States-Air-Force (USAF) resolution targets and achieve an SNR of 15 dB, while keeping NIR background below 6 mV. This 36-by-80-pixel array measures only 2.3 mm by 4.8 mm and can be thinned down to 25 µm, allowing it to become surgically compatible with intraoperative instruments and equipment, while remaining optics-free.

42 ENGINEERING↗

Optical rotation velocities and images of the spiral galaxy NGC 3198

H-alpha rotation velocities obtained from an echelle spectrogram to a radius of 2 arcmin for the spiral galaxy NGC 3198 agree well with the 21 cm rotation velocities of van Albada et al. (1985). The rotation curve is typical of Sc type galaxies in spite of NGC 3198's extended H I disk. From optical R and H-alpha-emission images, used to search for star-forming regions in the outer parts of this galaxy, several H-alpha knots are identified as far out as the Holmberg radius. With increasing radial distance out to 2 arcmin, the R-band surface brightness falls, the H-alpha is approximately constant, and the H I surface brightness rises.

Hunter, D. A.↗

Optical polarimetry and thermal imaging of the disc around Beta Pictoris

The dust disk around the main-sequence A5 star Beta Pic is characterized on the basis of recently obtained data. Optical polarimetry indicates that the disk has polarization of about 15 percent and polarization vectors normal to the scattering plane, indicating that the features observed are indeed a dust disk made visible by scattering. Thermal images of the central 13-arcsec-diameter region, obtained at 10 and 20 microns by Telesco et al. (1988) using the NASA Marshall 20-pixel bolometer array, suggest that the dust grains in the disk have a mean diameter of 1 micron or smaller. Also discussed are (1) unsuccessful searches for other nearby stars with disks and (2) the potential value of Hubble Space Telescope images for understanding the structure of Beta Pic.

Wolstencroft, R. D.↗

Formulation of the information capacity of the optical-mechanical line-scan imaging process

An expression for the information capacity of the optical-mechanical line-scan imaging process is derived which includes the effects of blurring of spatial, photosensor noise, aliasing, and quantization. Both the information capacity for a fixed data density and the information efficiency (the ratio of information capacity to data density) exhibit a distinct single maximum when displayed as a function of sampling rate, and the location of this maximum was determined by the system frequency-response shape, signal-to-noise ratio, and quantization interval.

Huck, F. O.↗

Full Field X-Ray Fluorescence Imaging Using Micro Pore Optics for Planetary Surface Exploration

Many planetary surface processes leave evidence as small features in the sub-millimetre scale. Current planetary X-ray fluorescence spectrometers lack the spatial resolution to analyse such small features as they only provide global analyses of areas greater than 100 mm(exp 2). A micro-XRF spectrometer will be deployed on the NASA Mars 2020 rover to analyse spots as small as 120m. When using its line-scanning capacity combined to perpendicular scanning by the rover arm, elemental maps can be generated. We present a new instrument that provides full-field XRF imaging, alleviating the need for precise positioning and scanning mechanisms. The Mapping X-ray Fluorescence Spectrometer - "Map-X" - will allow elemental imaging with approximately 100μm spatial resolution and simultaneously provide elemental chemistry at the scale where many relict physical, chemical and biological features can be imaged in ancient rocks. The arm-mounted Map-X instrument is placed directly on the surface of an object and held in a fixed position during measurements. A 25x25 mm(exp 2) surface area is uniformly illuminated with X-rays or alpha-particles and gamma-rays. A novel Micro Pore Optic focusses a fraction of the emitted X-ray fluorescence onto a CCD operated at a few frames per second. On board processing allows measuring the energy and coordinates of each X-ray photon collected. Large sets of frames are reduced into 2d histograms used to compute higher level data products such as elemental maps and XRF spectra from selected regions of interest. XRF spectra are processed on the ground to further determine quantitative elemental compositions. The instrument development will be presented with an emphasis on the characterization and modelling of the X-ray focussing Micro Pore Optic. An outlook on possible alternative XRF imaging applications will be discussed.

micro-XRF spectrometer↗

Fine Pitch Grids for an X-Ray Solar Imaging Spectrometer Fabricated by Optical Lithography and XeF2 Etching

Fine-pitch, sub-collimating X-ray grids have been developed for an instrument in the High Energy Solar Spectroscopic Imager , a proposed NASA mission. In addition to high-energy x- rays, the instrument requires collimation of photons with energies of less than 4 keV such that free-standing grids are required that have no material between the grid slats. Fabrication of these grids is described.

x-ray↗