Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Operational Efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Two-dimensional forms of robust CO 2 reduction photocatalysts

Photoelectrocatalysts that use sunlight to power the CO 2 reduction reaction will be crucial for carbon-neutral power and energy-efficient industrial processes. Scalable photoelectrocatalysts must satisfy a stringent set of criteria, such as stability under operating conditions, product selectivity, and efficient light absorption. Two-dimensional materials can offer high specific surface area, tunability, and potential for heterostructuring, providing a fresh landscape of candidate catalysts. From a set of promising bulk CO 2 reduction photoelectrocatalysts, we screen for candidate monolayers of these materials, then study their catalytic feasibility and suitability. For stable monolayer candidates, we verify the presence of visible-light band gaps, check that band edges can support CO 2 reduction, determine exciton binding energies, and compute surface reactivity. We find visible light absorption for SiAs, ZnTe, and ZnSe monolayers, and that due to a lack of binding, CO selectivity is possible. We thus identify SiAs, ZnTe, and ZnSe monolayers as targets for further investigation, expanding the chemical space for CO 2 photoreduction candidates.

36 MATERIALS SCIENCE↗

Experimental Investigation of Gaseous Mixtures of Ethane, Methane, and Carbon Dioxide as an Alternative to Conventional Fuel in Spark Ignition Engines

This study investigates the viability and performance of certain synthetic fuels in spark ignition internal combustion engine based stationary power generation wherein the fuel comprises a mixture of methane and ethane in high dilutions of carbon dioxide (CO 2 ). The fuel of concern is a byproduct of a novel method for producing ethylene from ethane. The byproduct gas mixture has a concentration of approximately 41% CO 2 , 40% ethane, and 5% methane by weight along with other minor compounds. Varying mixtures of ethane and methane combined with between 42% and 46% by weight CO 2 were used to evaluate the viability and efficiency of this fuel to operate in existing internal combustion engines as a means of reducing emissions and increasing industrial process efficiency. A 13 hp gasoline generator was repurposed as a test stand by incorporating a modified fuel induction system and instrumentation for data collection. A gas metering and mixing system was installed to precisely control the mass flow of gases induced into the engine. Various instrumentations were installed to monitor in-cylinder pressure, temperature at various locations, emissions, and fuel and airflow rates. Varying fuel mixtures and loads were tested and compared to gasoline. It was found that under a high load, the mixed gas was able to generate comparable thermal efficiency and power to gasoline. But under no load or a part load condition the indicated thermal efficiency was found to be about 21% lower than that of gasoline. Further, the mixed gas also resulted in up to 50% reduction in CO and NOx emissions when compared to gasoline.

42 ENGINEERING↗

Thermal management of a high temperature sodium sulphur battery stack

The sodium sulfur battery is an advanced secondary battery with high potential for grid-level storage due to their high energy density, low cost of the reactants, and high open-circuit voltage. However, as the operating temperature of the battery is high (about 300 °C), effective thermal management is required to prevent thermal runaway under high current density operation. Here, to develop efficient thermal management strategies, a detailed, thermo-electrochemical, non-isothermal, distributed dynamic model of a sodium-sulfur battery stack is developed. Models of three thermal management strategies are developed and analyzed in this work: active cooling, passive cooling, and hybrid cooling. The active cooling strategy uses air as the cooling medium whereas, the passive cooling strategy uses a phase change material. In the hybrid cooling strategy, both active and passive cooling strategies are used. Due to the high operating temperature of the sodium sulfur batteries, the rejected heat can be utilized effectively and consequently a high variability in the heat rejection rate may not be acceptable. Performance of these strategies is analyzed under high current density operation by evaluating the variability in the cell temperature during charge/discharge cycles, temperature difference between the cells based on their locations, and variability in the heat rejection rate. The phase change-based hybrid thermal management strategy with an embedded controller maintained the temperature variation within ±/- 2.8 °C. Considering the tradeoff between the capital cost for PCM, fan power requirement, and variability in the heat rejection rate, the optimal quantity of the PCM and the maximum air velocity for the maximum current density of 260 mA/cm 2 (0.55 C-rate) were found be 0.74 g/Wh and 3 m/s, respectively.

25 ENERGY STORAGE↗

FOULING MITIGATION FOR LASER IGNITERS IN NATURAL GAS ENGINES

Due to several recent developments in lasers and optics, laser igniters can now be designed to be (i) compact so as to have the same footprint as a standard spark plug, (ii) have low power draw, usually less than 50 Watts, and (iii) have vibration and temperature resistance at levels typical of reciprocating engines. Primary advantages of these laser igniters remain (i) extension of lean or dilution limits for ignition of combustible mixtures, and (ii) improved ignition at higher pressures. Recently, tests performed in a 350 kW six-cylinder stationary natural gas reciprocating engine retrofitted with these igniters showed an extension of the operational envelope to yield efficiency improvements of the order of 2.6% points while being compliant with the mandated emission regulations. Even though laser igniters offer promise, fouling of the final optical element that introduces the laser into the combustion chamber is of concern. After performing a thorough literature search, a test plan was devised to evaluate various fouling mitigation strategies. The final approach that was used is a combination of three strategies and helped sustain an optical transmissivity exceeding 98% even after 1500 h of continuous engine operation at 2400 rpm. Based on the observed trend in transmissivity, it now appears that laser igniters can last up to 6000 h of continuous engine operation in a stationary engine running at 1800 rpm.

spark ignited engines, laser ignition, natural gas↗

Optimization of InGaN quantum well interfaces for fast interwell carrier transport and low nonradiative recombination

Efficient high-power operation of light emitting diodes based on InGaN quantum wells (QWs) requires rapid interwell hole transport and low nonradiative recombination. The transport rate can be increased by replacing GaN barriers with that of InGaN. Introduction of InGaN barriers, however, increases the rate of the nonradiative recombination. In this work, we have attempted to reduce the negative impact of the nonradiative recombination by introducing thin GaN or AlGaN interlayers at the QW/barrier interfaces. The interlayers, indeed, reduce the nonradiative recombination rate and increase the internal quantum efficiency by about 10%. Here, the interlayers do not substantially slow down the interwell hole transport; for 0.5 nm Al 0.10 Ga 0.90 N interlayers the transport rate has even been found to increase. Another positive feature of the interlayers is narrowing of the QW PL linewidth, which is attributed to smoother QW interfaces and reduced fluctuations of the QW width.

carrier transport↗

Compact Hydrogen Generator

GTI Energy (GTI) is developing a One-Step Hydrogen Generation through Sorption Enhanced Reforming (SER) process that provides significant improvements in energy productivity (18% efficiency improvement), environmental performance (90% CO 2 capture and up to 98%), product yield (30% reduction in natural gas consumption), and economic benefit (reduce Levelized Cost of Hydrogen by 28%) as compared to the Steam Methane Reforming process. A 20,000 Standard Cubic Feet per Day pilot plant (or Feasibility Demonstration Unit, FDU) located at the Energy and Environmental Research Center (EERC) was moved to GTI’s Des Plaines, IL facility and reconfigured to utilize an atmospheric calciner which enables CO 2 capture as a high purity product. Between operations at EERC and GTI’s facility, the pilot plant has demonstrated over 110 hours of sorbent enhanced hydrogen production at 80% or higher purity. The primary objective of this project is to advance the development of GTI’s Sorption Enhanced Reforming (SER) hydrogen production technology, known as the Compact Hydrogen Generator (CHG), to allow for a future commercial demonstration. This effort was performed over the course of 51 months. The previous effort demonstrated that previously observed catalyst deactivation can be mitigated with different catalyst substrates and operating conditions. This follow-on effort will improve both the system operational reliability, and system efficiency. Additionally, a novel approach for the calcination process will be demonstrated which can reduce the cost of carbon dioxide capture by up to 60% compared to equivalent commercial approaches.

03 NATURAL GAS↗

Enabling Stable and Salt-Free Formic Acid Production via Reactive Interface Optimization in Forward-Bias Bipolar-Membrane CO2 Electrolyzers

Electrochemical conversion of CO2 to liquid products is limited by parasitic reactions that consume products and destabilize operation. Here, we show that salt-free formic acid synthesis in a forward-bias bipolar-membrane CO2 electrolyzer is governed by a coupled reaction-transport instability driven by parasitic anode formic acid oxidation. Operando mass spectrometry reveals that this process proceeds through CO-mediated poisoning, identifying catalyst tolerance to CO as a key descriptor of anode selectivity. Among the catalysts examined, PtRu/C preferentially promotes hydrogen oxidation over formic acid oxidation. Coupling this catalyst with transport-interface engineering improves product removal, enhances Faradaic and energy efficiency, and enables stable operation at 200 mA/cm2 for 190 h with a voltage decay of 0.64 mV/h. Techno-economic analysis indicates an 18% reduction in minimum selling price and highlights product concentration as the dominant cost lever. These results establish a general framework for suppressing product oxidation in liquid-product electrolyzers.

Hu, Leiming↗

Optimized Lie–Trotter–Suzuki decompositions for two and three non-commuting terms

Lie–Trotter–Suzuki decompositions are an efficient way to approximate operator exponentials exp ( t H ) when H is a sum of n (non-commuting) terms which, individually, can be exponentiated easily. They are employed in time-evolution algorithms for tensor network states, digital quantum simulation protocols, path integral methods like quantum Monte Carlo, and splitting methods for symplectic integrators in classical Hamiltonian systems. Here, we provide optimized decompositions up to order t 6 . The leading error term is expanded in nested commutators (Hall bases) and we minimize the 1-norm of the coefficients. For n = 2 terms, several of the optima we find are close to those in McLachlan (1995). Generally, our results substantially improve over unoptimized decompositions by Forest, Ruth, Yoshida, and Suzuki. We explain why these decompositions are sufficient to efficiently simulate any one- or two-dimensional lattice model with finite-range interactions. This follows by solving a partitioning problem for the interaction graph.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Direct Air Capture Using Aqueous Amino Acid Solvents in a Crossflow Absorber

Carbon dioxide (CO 2 ) is the most abundant of all greenhouse gases (GHGs). CO 2 levels in the atmosphere are 50% higher than in the preindustrial era, trapping heat. CO 2 removal from the atmosphere by direct air capture (DAC) is needed to achieve the internationally agreed global temperature goals. The most common CO 2 capture technology is absorption by aminebased solvents in packed columns. Amino acid solutions have recently gained attention due to their advantages over traditional amine solvents. To be implemented effectively, DAC industrial processes need to handle large airflow rates in separation absorbers. The large air and solvent flow rates preclude the use of countercurrent columns due to high-pressure drops and the occurrence of flooding. Crossflow air−liquid absorbers are used to handle large air and liquid volumes due to their lower-pressure drop. The objective of this work is to study the influence of crossflow absorber geometric parameters and operating conditions on product formation and process efficiency. An already derived theoretical model for countercurrent absorbers has been modified to simulate the operation of a crossflow DAC absorber. The predictive model was implemented into a computer code that was used to study the efficiency of the processes as geometric equipment dimensions and operating parameters vary. Practical suggestions are made to design more efficient DAC processes.

Absorption↗

Coefficient-to-Basis Network: a fine-tunable operator learning framework for inverse problems with adaptive discretizations and theoretical guarantees

We propose a Coefficient-to-Basis Network (C2BNet), a novel framework for solving inverse problems within the operator learning paradigm. C2BNet efficiently adapts to different discretizations through fine-tuning, using a pre-trained model to significantly reduce computational cost while maintaining high accuracy. Unlike traditional approaches that require retraining from scratch for new discretizations, our method enables seamless adaptation without sacrificing predictive performance. Furthermore, we establish theoretical approximation and generalization error bounds for C2BNet by exploiting low-dimensional structures in the underlying datasets. Our analysis demonstrates that C2BNet adapts to low-dimensional structures without relying on explicit encoding mechanisms, highlighting its robustness and efficiency. To validate our theoretical findings, we conducted extensive numerical experiments that showcase the superior performance of C2BNet on several inverse problems. The results confirm that C2BNet effectively balances computational efficiency and accuracy, making it a promising tool to solve inverse problems in scientific computing and engineering applications.

97 MATHEMATICS AND COMPUTING↗

Medium-Duty Delivery Truck Integrated Bidirectional Wireless Power Transfer System With Grid and Stationary Energy Storage System Connectivity

Electric vehicles (EVs) can provide power to the grid or buildings similar to distributed energy resources (DER) for energy balancing applications or optimizing the operation of the microgrids in harmony with the other DER assets. This article presents the operating modes of a bidirectional wireless power transfer (WPT) system designed for a medium-duty package delivery vehicle. The WPT system designed for this study can transfer 20 kW of power across 11 in of air gap using custom-designed double-D (DD) couplers with LCC–LCC tuning networks. The proposed system utilizes a 480-V three-phase grid connection, a plug-in hybrid delivery truck with bidirectional WPT, and a stationary energy storage system (SESS) that can be connected to the primary-side dc link. Due to the differences in primary and secondary dc bus voltages, and considering the voltage of the SESS, asymmetric voltage gains were used in the system. Sensitivity analyses of this system with respect to these voltage levels are presented. Five different operating modes of the grid, SESS, and the EV battery are investigated with experimental results. Control algorithms are described for grid-to-vehicle (G2V) and vehicle-to-grid (V2G) operating modes. A bidirectional WPT system is operated with a power factor of 0.99 on the grid side in every operating mode. The EV battery was charged with 20.3 kW with an overall efficiency of 93.02% in the G2V operating mode. Finally, in the V2G operating mode, the WPT system provided 12.82 kW of power back to the grid with an overall efficiency of 89.08%.

25 ENERGY STORAGE↗

Comparative Analysis of Model Predictive Control and MPC-Informed Rule-Based Control for Thermal Storage Operation in Ultra-Low Temperature 4th Generation District Heating Networks

The integration of thermal storage and heat pumps in district heating networks (DHNs) can significantly enhance operational flexibility and energy efficiency; however, the practical deployment of advanced control strategies is often hindered by forecasting requirements and computational complexity. This study presents a comparative analysis of thermal storage control strategies in an ultra-low-temperature fourth-generation DHN, focusing on the development of a simplified rule-based control (RBC) explicitly informed by Model Predictive Control (MPC) behavior. The proposed methodology systematically analyzes the charging and discharging decisions of an MPC-controlled system under ideal forecasting conditions and extracts recurrent control patterns as a function of key system variables, including outdoor temperature, thermal demand, and electricity price. These patterns are translated into a set of structured time- and condition-based rules, resulting in an MPC-informed RBC that embeds predictive insights while preserving implementation simplicity and operational transparency. The approach is validated on a realistic mixed-use urban district in Denver, Colorado, USA, equipped with a centralized air-source heat pump, distributed water-to-water heat pumps, and a central thermal storage unit. Results show that the tuned RBC attains approximately 96% of ideal MPC economic performance (-27% of costs), preserves values of technical and environmental indicators (reduction only of 2-3%), and substantially reduces complexity. Sensitivity analyses further demonstrate the robustness of the RBC under varying operational conditions (i.e., ambient temperature, electricity price). Overall, the study demonstrates that MPC-informed rule-based control represents an effective trade-off between control performance and real-world applicability, enabling the integration of additional system components while maintaining simplicity, robustness, and ease of implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A non-fueled nuclear-heated rod for in-pile transient boiling studies

Separate-effects boiling experiments have recently been conducted in the Transient Reactor Test Facility at Idaho National Laboratory to investigate transient heating and irradiation effects on cladding-to-coolant heat transfer. Specifically, transient critical heat flux (CHF) remains an important area of research, and better understanding of this phenomenon has potential for improving predictive models related to operational and safety limits. Consequently, this knowledge is expected to improve efficiency of light-water reactor operations. A novel borated nuclear-heated rodlet (BNHR) was designed to enable observation of transient cladding-to-coolant heat transfer phenomena. The final BNHR design takes a surrogate approach, wherein nuclear heating is induced by 10 B(n, α) reactions rather than derived from fissions in a fueled specimen. The structure of the BNHR consists of a hollowed out borated (B nat ~ 2.05 wt %) stainless steel tube with an hourglass-shaped outer surface, capped at both ends with non-borated stainless steel. This geometry allows for inner-rodlet instrumentation and generation of the highest nuclear heating rates near the center of the rodlet to ensure onset of boiling near instrumentation for real-time observation. A novel approach to measuring the nuclear energy deposition rate in the BNHR separate and apart from the influence of the coolant, termed the n-a thermometer, is also detailed in this paper. This device has demonstrated excellent repeatability, and measurements indicate predictive modeling results for energy deposition in the BNHR rod agree within a 10% margin of the experiment measurements. In conclusion, these results give confidence that the BNHR design has successfully met experiment objectives.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Helical Fins for Concentrated Solar Receivers: Design Optimization and Entropy Analysis

Concentrated solar power (CSP) with thermal energy storage (TES) has the potential to achieve grid parity. This can be realized by operating CSP systems at temperatures above 700 °C with high-efficiency sCO 2 power cycles. However, operating CSP systems at such temperatures poses several challenges, among which the design of solar receivers to accommodate increased thermal loads is critical. To this end, this work explores and optimizes various swirl-inducing internal fin designs for solar receiver tubes. These fin designs not only improve the thermal performance of receiver tubes but also levelize temperature unevenness caused by non-uniform thermal loading. In this work, the geometric parameters of the fin designs are optimized to maximize the Nusselt number with a constraint on the friction factor. This optimization, however, is computationally intensive, requiring hundreds of simulation calls to computational fluid dynamics (CFD) models. Here, to circumvent this problem, surrogate models are used to approximate the simulation outputs needed during the optimization. In addition, this study also examines the fin designs from an entropy generation perspective. To this end, the entropy contributions from thermal and viscous effects are quantitatively compared while varying the operational Reynolds number.

14 SOLAR ENERGY↗

Integrated Turbine Component Cooling Designs Facilitated by Additive Manufacturing and Optimization

This research program involved the development of improved gas turbine cooling by optimizing the combined internal and film cooling configurations used for turbine blades and vanes. Improved cooling of turbine airfoils allows the gas turbines to be operated at higher temperatures which improves efficiency for gas turbine-based power generation. This also facilitates operation with hydrogen-based fuels which inherently generate higher operating temperatures. Designs of the new cooling configurations were based on the added geometric flexibility that is available when using metal additive manufacturing techniques. When making these designs, adjustments were made to account for imperfections occurring in the metal additive manufacturing process. New designs for film cooling holes were developed using computational adjoint gradient optimization techniques which generated a unique film cooling hole with 70% greater film cooling effectiveness compared to conventional shaped film cooling holes. A major factor in improving the film cooling effectiveness were small external protrusions on either side of the new hole which generated vortices that pushed coolant towards the surface and increased the lateral spreading of the coolant. Our studies also included optimization of film cooling holes that can be built with conventional manufacturing techniques and optimizing the internal coolant channels that supply coolant to the film cooling holes. Various internal coolant channel shapes were investigated and designs that maximized the cooling of the airfoil while minimizing pressure losses in the channel flows were identified. Testing and verification of the performance of the final configurations was done with a transonic wind tunnel facility which allowed testing at engine realistic high velocities. Final testing of the combined internal and film cooling configurations was done by incorporating the configurations in Penn State’s National Experimental Turbine (NExT) vane. These tests confirmed the enhanced overall cooling effectiveness provided by the new cooling configuration designs.

03 NATURAL GAS↗

To dee or not to dee: costs and benefits of altering the triangularity of a steady-state DEMO-like reactor

Shaping a tokamak plasma to have a negative triangularity may allow operation in an ELM-free L-mode regime and with a larger strike-point radius, ameliorating divertor power-handling requirements. However, the shaping has a potential drawback in the form of a lower no-wall ideal beta limit, found using the MHD codes CHEASE and DCON. Using the new fusion systems code FAROES, we construct a steady-state DEMO2 reactor model. This model is essentially zero-dimensional and neglects variations in physical mechanisms like turbulence, confinement, and radiative power limits, which could have a substantial impact on the conclusions deduced herein. Keeping its shape otherwise constant, we alter the triangularity and compute the effects on the levelized cost of energy (LCOE). If the tokamak is limited to a fixed B field, then unless other means to increase performance (such as reduced turbulence, improved current drive efficiency or higher density operation) can be leveraged, a negative-triangularity reactor is strongly disfavored in the model due to lower \beta_N limits at negative triangularity, which leads to tripling of the LCOE. However, if the reactor is constrained by divertor heat fluxes and not by magnet engineering, then a negative-triangularity reactor with higher B0 could be favorable: we find a class of solutions at negative triangularity with lower peak heat flux and lower LCOE than those of the equivalent positive triangularity reactors.

CHEASE↗

To dee or not to dee: costs and benefits of altering the triangularity of a steady-state DEMO-like reactor

Shaping a tokamak plasma to have a negative triangularity may allow operation in an edge-localized mode-free L-mode regime and with a larger strike-point radius, ameliorating divertor power-handling requirements. However, the shaping has a potential drawback in the form of a lower no-wall ideal beta limit, found using the MHD codes CHEASE and DCON. Using the new fusion systems code FAROES, we construct a steady-state DEMO2 reactor model. This model is essentially zero-dimensional and neglects variations in physical mechanisms like turbulence, confinement, and radiative power limits, which could have a substantial impact on the conclusions deduced herein. Keeping its shape otherwise constant, we alter the triangularity and compute the effects on the levelized cost of energy (LCOE). If the tokamak is limited to a fixed B field, then unless other means to increase performance (such as reduced turbulence, improved current drive efficiency or higher density operation) can be leveraged, a negative-triangularity reactor is strongly disfavored in the model due to lower β N limits at negative triangularity, which leads to tripling of the LCOE. However, if the reactor is constrained by divertor heat fluxes and not by magnet engineering, then a negative-triangularity reactor with higher B 0 could be favorable: we find a class of solutions at negative triangularity with lower peak heat flux and lower LCOE than those of the equivalent positive triangularity reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗