Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OUTDOORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

From biowaste to BioPave: Biological pathways for sequestration of anthropogenic CO 2 and enhancing durability of roadway infrastructures

Biomass-derived bio-oils are emerging as sustainable, low-carbon alternatives for construction materials, particularly in innovative pavement applications, 'BioPave'. Here, this study evaluates bio-oils from various sources, including algae and wastewater biomass, revealing variations in carbon, nitrogen, and sulfur contents, along with viscosity. We focused on their application in outdoor construction, assessing their resistance to thermal and solar radiation, and moisture. The study also examines their interaction with siliceous surfaces and their influence on asphalt adhesion in BioPave systems under moisture conditions. Laboratory experiments and computational modeling demonstrated molecular composition significantly influenced bio-oils' responses to thermal and UV exposure. Bio-oils rich in polar groups showed hardening upon thermal treatment, while those with higher concentrations of saturated aliphatics remained more stable. Furthermore, our findings highlight the significance of dosage control in maximizing beneficial effects of bio-oils in intermolecular interactions at bitumen-aggregate interface in BioPave applications. These findings offer insights into the potential of bio-oils in sustainable construction and the need for dosage control to optimize pavement performance.

59 BASIC BIOLOGICAL SCIENCES↗

The influence of ambient light spectrum (LED, INC, CFL, Xenon…) on the efficiency of perovskite indoor photovoltaic solar cells for Internet of Things (IoT) applications

This record provides a numerical investigation of a MAGeI₃-based perovskite solar cell with the structure FTO/TiO₂/MAGeI₃/Spiro-OMeTAD, evaluated for both outdoor and indoor light-harvesting applications using the SCAPS-1D simulator. Device performance is analyzed under AM 1.5G sunlight and several artificial light sources, including LED, incandescent, compact fluorescent lamp (CFL), flashlight, and xenon illumination. The study reports initial and optimized power conversion efficiencies and examines the influence of absorber layer thickness and bandgap on device performance under different lighting conditions. The results highlight the potential of MAGeI₃-based perovskite solar cells for indoor energy harvesting and low-power Internet of Things (IoT) applications.

14 SOLAR ENERGY↗

Interfacial stabilization for inverted perovskite solar cells with long-term stability

Perovskite solar cells (PSCs) commonly exhibit significant performance degradation due to ion migration through the top charge transport layer and ultimately metal electrode corrosion. Here, we demonstrate an interfacial management strategy using a boron chloride subphthalocyanine (Cl 6 SubPc)/fullerene electron-transport layer, which not only passivates the interfacial defects in the perovskite, but also suppresses halide diffusion as evidenced by multiple techniques, including visual element mapping by electron energy loss spectroscopy. As a result, we obtain inverted PSCs with an efficiency of 22.0% (21.3% certified), shelf life of 7000 h, Τ 80 of 816 h under damp heat stress (compared to less than 20 h without Cl 6 SubPc), and initial performance retention of 98% after 2000 h at 80 °C in inert environment, 90% after 2034 h of illumination and maximum power point tracking in ambient for encapsulated devices and 95% after 1272 h outdoor testing ISOS-O-1. Our strategy and results pave a new way to move PSCs forward to their potential commercialization solidly.

14 SOLAR ENERGY↗

Weather aging effects on modified asphalt with rubber-polyethylene composites

Weather aging may cause more severe degradation on asphalt than thermal-oxidative aging due to the synergistic effect among oxygen, heat, ultraviolet (UV) radiation, and moisture. This study aimed to investigate weather aging effects and anti-aging mechanisms on asphalt modified with rubber-polyethylene (PE) composites. The modified binder blends and asphalt mixtures were subjected to outdoor weather aging. Dynamic shear rheometer (DSR), Fourier transform infrared spectroscopy (FTIR), Gel permeation chromatography (GPC), and optical microscopy tests were adopted to characterize the rheological properties, aging resistance, polymer degradation, and anti-aging mechanisms of modified binder blends, respectively. Mixture performance tests including Asphalt Pavement Analyzer (APA) and Ideal-CT tests were used to evaluate rutting and cracking resistance of asphalt mixtures. Results showed that weather aging can cause more severe aging to asphalt binders than pressure aging vessel (PAV) due to the severe degradation of PE particles. Rubber-PE composites alloyed with an extruder proved to stabilize PE particles in asphalt and significantly improve the aging resistance of modified binder blends. Furthermore, the enhanced aging resistance is attributed to the dispersion of PE particles and carbon black released by soluble rubbers.

Aging resistance↗

Application of Intelligent Load Control to Manage Building Loads to Support Rapid Growth of Distributed Renewable Generation

Electricity utilities are faced with the mounting challenge of providing a stable supply of power to meet the growing demand while also integrating rapid growth in distributed variable renewable generation. Traditional means of balancing short- and long-term supply and demand imbalance will be expensive. Alternative approaches of using flexible loads in buildings are needed to mitigate the imbalance at a lower cost. This paper shows how the intelligent load control (ILC) process can be used to manage loads in buildings by dynamically prioritizing loads for curtailment using both quantitative and qualitative criteria. The ILC process can be deployed on low-cost computing platforms without the need for any additional sensing. ILC was first validated in a simulation environment to provide two grid service use cases: (1) managing monthly peak electricity demand and (2) managing buildings’ electricity consumption during a capacity bidding event. After being successfully tested in a simulation environment, ILC was deployed on real buildings to manage electricity consumption to provide two different use cases under different outdoor operating conditions. Both the simulation tests and the real building experiments were deployed using VOLTTRON™, a distributed sensing and control platform. The results from the tests and experiments showed that ILC was able to manage the controllable loads (heat pumps) in the building to maintain the electricity consumption at the desired level without a significant impact on occupant comfort. Overall, the results demonstrate that the ILC allows coordination of the controllable loads and provides a more intelligent means of load management than the traditional duty-cycling approach.

Kim, Woohyun↗

Urban heat island in southern Europe: The case study of Hania, Crete

The aim of the present paper is to analyze the results of the urban heat island research for a coastal densely built small Mediterranean town namely Hania, Crete, Greece. The specific research targets to verify the existence, the intensity, the size and the form of the urban heat island phenomenon in the specific region as well as to understand its correlation with the local weather conditions. Nine urban and three rural meteorological stations are used for this study. Temperature and relative humidity measurements are collected from May 26, 2007 until October 24, 2007. In parallel, meteorological data including wind speed and direction, barometric pressure, sunlight and precipitation for the specific region are collected and elaborated for cross-correlation with the appearance of the urban heat island (UHI) phenomenon. During summer period, where the temperature is high, the UHI takes its maximum intensity, of about 8 C. Also, the form of the UHI is strongly influenced from the wind speed and direction. The northern winds expand the UHI front, while the western winds contribute to the UHI reduction. Finally the Discomfort Index (DI) is calculated for the 2007 summer period to indicate the outdoor living conditions. (author)

54 ENVIRONMENTAL SCIENCES↗

Night ventilation control strategies in office buildings

In moderate climates night ventilation is an effective and energy-efficient approach to improve the indoor thermal environment for office buildings during the summer months, especially for heavyweight construction. However, is night ventilation a suitable strategy for office buildings with lightweight construction located in cold climates? In order to answer this question, the whole energy-consumption analysis software EnergyPlus was used to simulate the indoor thermal environment and energy consumption in typical office buildings with night mechanical ventilation in three cities in northern China. The summer outdoor climate data was analyzed, and three typical design days were chosen. The most important factors influencing night ventilation performance such as ventilation rates, ventilation duration, building mass and climatic conditions were evaluated. When night ventilation operation time is closer to active cooling time, the efficiency of night ventilation is higher. With night ventilation rate of 10 ach, the mean radiant temperature of the indoor surface decreased by up to 3.9 C. The longer the duration of operation, the more efficient the night ventilation strategy becomes. The control strategies for three locations are given in the paper. Based on the optimized strategies, the operation consumption and fees are calculated. The results show that more energy is saved in office buildings cooled by a night ventilation system in northern China than ones that do not employ this strategy. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental study of the salt gradient solar pond stability

Many natural systems such as oceans, lakes, etc.., are influenced by the effect of double-diffusive convection. This phenomenon, which is a combination of heat and mass transfer, can destroy the stability of system-flows. In the case of solar ponds the middle layer, that is linearly stratified, acts as a thermal and mass insulator for the lower layer. This middle layer, called the Non-Convective Zone (NCZ), needs special care to avoid convection and to maintain its stability. In fact, due to an excess of heat stored, a thermal gradient occurs within the NCZ. A convective movement appears at the bottom of the stratified-layers and then grows to a double-diffusive convection movement. This movement transforms the stratified-layers into a well mixed layer, reducing the storage capacity of the pond. Laboratory small-scale pond and middle-scale outdoor solar ponds were designed and built to provide both quantitative data and to study the dynamic processes in solar ponds, including the behavior of the gradient zone. Particle Image Velocimetry (PIV) visualization-experiments carried out in the mechanical and energetic laboratory in the engineering school of Tunisia and experiments in the field showed that the instability of solar ponds could be limited by using porous media placed in the lower layer of the stratification. (author)

14 SOLAR ENERGY↗

Aging behavior of polymeric solar absorber materials: Aging on the component level

Within this study, the aging behavior of a PPE + PS absorber material was investigated on the absorber component level. To indicate aging, characteristic mechanical values were determined by indentation tests of specimens taken from components and exposed to laboratory aging (140 C in air, 80 C in water) and service near outdoor aging conditions (stagnation in northern climate). In addition to the mechanical tests, the unaged and aged specimens were also characterized thermo-analytically via differential scanning calorimetry (DSC). The results indicate that reductions in both characteristic mechanical values of the indentation tests, i.e., load of the first transition and ultimate indentation, reflect at least some physical aging although chemical aging may also be of importance based on previous analytical investigations of laboratory aged polymer films. While laboratory aging in air at 140 C and service exposure at a test facility in Oslo (N) under stagnation conditions led to a significant reduction in the mechanical indentation resistance, no influence of laboratory aging in water at 80 C on the mechanical behavior of the absorber sheet was found. Depending on the ultimate failure criterion applied (reduction of characteristic mechanical values to 80% and 50%, respectively), the technical service life found for hot air laboratory and stagnation service conditions was found to be less than 51 and 159 h, respectively. As these durations are significantly below the estimated stagnation conditions accumulated in the desired operation lifetime for such a collector, the PPE + PS type investigated does not seem to be a proper material candidate for solar thermal absorbers. Finally, based on the results obtained, a relation between laboratory aging time in air at 140 C and cumulated irradiation energy during exposure on the test facility in Oslo was established. (author)

14 SOLAR ENERGY↗

System dynamic model and charging control of lead-acid battery for stand-alone solar PV system

The lead-acid battery which is widely used in stand-alone solar system is easily damaged by a poor charging control which causes overcharging. The battery charging control is thus usually designed to stop charging after the overcharge point. This will reduce the storage energy capacity and reduce the service time in electricity supply. The design of charging control system however requires a good understanding of the system dynamic behaviour of the battery first. In the present study, a first-order system dynamics model of lead-acid battery at different operating points near the overcharge voltage was derived experimentally, from which a charging control system based on PI algorithm was developed using PWM charging technique. The feedback control system for battery charging after the overcharge point (14 V) was designed to compromise between the set-point response and the disturbance rejection. The experimental results show that the control system can suppress the battery voltage overshoot within 0.1 V when the solar irradiation is suddenly changed from 337 to 843 W/m{sup 2}. A long-term outdoor test for a solar LED lighting system shows that the battery voltage never exceeded 14.1 V for the set point 14 V and the control system can prevent the battery from overcharging. The test result also indicates that the control system is able to increase the charged energy by 78%, as compared to the case that the charging stops after the overcharge point (14 V). (author)

14 SOLAR ENERGY↗

Modeling, design and thermal performance of a BIPV/T system thermally coupled with a ventilated concrete slab in a low energy solar house: Part 2, ventilated concrete slab

This paper is the second of two papers that describe the modeling and design of a building-integrated photovoltaic-thermal (BIPV/T) system thermally coupled with a ventilated concrete slab (VCS) adopted in a prefabricated, two-storey detached, low energy solar house and their performance assessment based on monitored data. The VCS concept is based on an integrated thermal-structural design with active storage of solar thermal energy while serving as a structural component - the basement floor slab ({proportional_to}33 m{sup 2}). This paper describes the numerical modeling, design, and thermal performance assessment of the VCS. The thermal performance of the VCS during the commissioning of the unoccupied house is presented. Analysis of the monitored data shows that the VCS can store 9-12 kWh of heat from the total thermal energy collected by the BIPV/T system, on a typical clear sunny day with an outdoor temperature of about 0 C. It can also accumulate thermal energy during a series of clear sunny days without overheating the slab surface or the living space. This research shows that coupling the VCS with the BIPV/T system is a viable method to enhance the utilization of collected solar thermal energy. A method is presented for creating a simplified three-dimensional, control volume finite difference, explicit thermal model of the VCS. The model is created and validated using monitored data. The modeling method is suitable for detailed parametric study of the thermal behavior of the VCS without excessive computational effort. (author)

14 SOLAR ENERGY↗

Experimental comparison of pyranometer, reflectometer, and spectrophotometer methods for the measurement of roofing product albedo

Albedo (solar reflectance) can be measured outdoors with a pyranometer or indoors with a hemispherical reflectometer or a spectrophotometer. The current study evaluates these methods and their applicability to roofing materials by measuring and comparing the ASTM E1918 (pyranometer), non-ASTM E1918A (alternative pyranometer), ASTM C1549 (reflectometer), and E903 (spectrophotometer) albedos of 10 roofing products, including three single-ply membranes, one asphalt shingle, three roofing aggregates, and three high-profile tiles. It uses full-size (4 m × 4 m) assemblies in the E1918 and E1918A trials; corrects the E1918 albedos to remove shadow and background errors; and evaluates C1549 and E903 albedos with two different irradiance spectra, one global horizontal and the other beam normal. E1918A albedos matched E1918 corrected (E1918_cor) albedos to within 0.036. Furthermore, agreement between C1549 air mass 1 global horizontal (C1549_G1) albedo and E1918_cor albedo was within 0.015 for membrane and shingle coupons, and within 0.031 for aggregates, though the uncertainty in the latter agreement was up to 0.043. After minor corrections, C1549_G1 albedos of flat or slightly convex tile chips were 0.032–0.052 higher than the E1918_cor albedos of their corresponding high-profile tile assemblies because high-profile surfaces have concavities. Switching to the beam-normal albedo C1549_1.5E increased the C1549 albedos of the 10 tested products by 0.004–0.054, with the largest increases (C1549_1.5E – C1549_G1) accruing to spectrally selective cool colors. Using C1549_1.5E albedo to characterize a chip of a cool-colored tile compounded the error induced by representing a high-profile surface by a flat or slightly convex specimen.

14 SOLAR ENERGY↗

Design, characterization and indoor validation of the optical soiling detector “DUSST”

Nowadays, photovoltaic (PV) technology has reached a high level of maturity in terms of module efficiency and cost competitiveness in comparison with other energy technologies. As PV has achieved high levels of deployment, the development of devices that can help to reduce PV operation and maintenance costs has become a priority. Soiling can be cause of significant losses in certain PV plants and its detection has become essential to ensure a correct mitigation. For this reason, accurate and low-cost monitoring devices are needed. While soiling stations have been traditionally employed to measure the impact of soiling, their high cost and maintenance have led to the development of innovative low-cost optical sensors, such as the device presented in this work and named “DUSST” (Detector Unit for Soiling Spectral Transmittance). The thermal characterization of DUSST’s components and the methodology used to predict soiling transmittance losses are presented in this study. The results demonstrate that the losses can be predicted with an error lower than 1.4%. The method has been verified with an experimental campaign with naturally soiled coupons exposed outdoors in Jaén, Spain.

14 SOLAR ENERGY↗

Thermal model to quantify the impact of sub-bandgap reflectance on operating temperature of fielded PV modules

Minimizing module heating is an effective way to increase the lifetime energy output of photovoltaic systems. Maximizing the reflection of light that is unusable for energy conversion is one of the most promising ways to reduce the operating temperature of fielded modules. We derive a model based on a steady-state energy balance to quantify the temperature benefit of cell or module optical modifications aimed at improving reflection of light with photon energies below the photovoltaic cell bandgap energy. This more detailed model is then simplified so that, from outdoor measured data, temperature differences arising from reflectance can be isolated from those arising from irradiance, wind speed, and module standard-test-condition efficiency.

14 SOLAR ENERGY↗

Use of non-contact voltmeter to quantify potential induced degradation in CdTe modules

Potential induced degradation (PID) is a significant reliability issue for photovoltaic modules in the field. Conventionally, to detect the PID-affected modules, all the modules in a string are individually disconnected and measured using I-V (current–voltage) tracers. It is extremely time-consuming, expensive and unsafe (if the module connectors are field aged) approach. In our approach, we aim detecting the PID-affected modules quickly, inexpensively and safely without disconnecting individual modules in the string. In this study, contactless electrostatic voltmeter’s (ESV) strength was explored to detect the PID-affected cadmium telluride (CdTe) modules in a string. These contactless measurements on high-voltage PV strings could make this technique unique and preferable to detect PID-affected modules in a string compared to the I-V curve method. In this work, a CdTe module was stressed for PID using the Aluminum (Al) foil method in a walk-in environmental chamber, which resulted in a reduction of module's peak current (I max ), peak voltage (Vmax), and fill factor (FF), and hence power (Pmax). Outdoor light I-V, EL, and ESV measurements were performed pre- and post-PID to determine the effectiveness of the non-contact ESV technique. Further, the ESV technique successfully detected the change in V max , and hence Pmax, compared to the pre-and post-PID conditions. A difference of less than 2% was observed in the results of the non-contact and non-interruptive method compared to the conventionally used interruptive voltmeter or I-V tracer method. This technique and the test results demonstrate a significant promise to identify poor-performing modules in PV string without disconnection of individual modules in the string.

14 SOLAR ENERGY↗

Modeling, testing, and mitigation of electromagnetic pulse on PV systems

Electromagnetic Pulse (EMP) poses a significant threat to the normal operation of power systems, especially with the increasing penetration of renewable energy. Without adequate protection, EMP can severely damage equipment or result in circuit breakdowns or short circuits. Solar photovoltaic (PV) facilities are particularly susceptible to EMP since PV systems are outdoors and exposed to EMP radiation. To assess and mitigate this threat, this paper summarizes various models and tests used to study the effects of EMP on PV systems, assesses the nature of the threat, and identifies measures to mitigate it. The paper provides a comprehensive review by categorizing analytical methods based on their pros and cons, introducing and describing EMP-related events, and providing a taxonomy of analytical methods for studying EMP. This paper compares the processes of modeling, testing, and mitigating EMP at both the component and system levels of PV systems. Furthermore, it also presents a case study that reveals the vulnerability of solar inverters to EMP using the pulse current injection method. Finally, the paper discusses some of the remaining challenges that should be considered in future solar PV system design and deployment.

14 SOLAR ENERGY↗

Comprehensive assessment of metrology techniques for heliostat efficiency and performance evaluation

Concentrating solar power plants, specifically central receiver type systems and their heliostat field, are struggling with negative reputation in the USA, due to perceived underperformance and reliability issues. This is in part due to a lack of standards for performance assessment as well as overly simplified techno-economical models. A better understanding of influences and losses along the solar radiation path from the sun, across the solar collector to the receiver, increases the fidelity of heliostat efficiency assessment as well as solar field performance predictions. Such data are currently scarce and require a complete set of metrology capabilities to evaluate direct solar irradiance, sun shape, atmospheric attenuation, reflectance, collector shape, slope errors and total beam dispersion. In preparation for establishing a 3rd party metrology platform in collaboration with Sandia National Labs, NLR conducted a scoping study on available metrology. We present an extensive overview of techniques and commercial systems for each category. Our work includes an analysis to increase understanding of strengths and limitations of the many techniques used for surface shape and slope measurement. This applies to a controlled, indoor or outdoor laboratory environment assessing a single heliostat.

14 SOLAR ENERGY↗