Ultrasonic Evaluation of Thermal Degradation in Adhesive Bonds
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Special requirements of the space industry for more detailed knowledge of the quality and reliability of each electroexplosive device (EED) selected for use aboard a spacecraft are described. Statistical methods do not practically demonstrate the high reliability needed. To close this gap, nondestructive test techniques and instrumentation for 1-W/1-A no-fire devices have been developed. Several lots of squibs have been evaluated using these techniques and instrumentation. They yield data as to the quality and normal behavior of each electroexplosive device without firing or degrading the unit. Performance data were obtained by initiating the EED's with an impulsive waveform and sensing the initiation characteristics, sensitivity, and output.
Explore the source record for details and available documents.
AGR 1 was the first in a series of experiments designed to test US TRISO fuel under high temperature gas-cooled reactor irradiation conditions. This experiment was irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) and is currently undergoing post irradiation examination (PIE) at INL and Oak Ridge National Laboratory. One component of the AGR 1 PIE is the experimental evaluation of the burnup of the fuel by two separate techniques. Gamma spectrometry was used to non destructively evaluate the burnup of all 72 of the TRISO fuel compacts that comprised the AGR 1 experiment. Two methods for evaluating burnup by gamma spectrometry were developed, one based on the Cs 137 activity and the other based on the ratio of Cs 134 and Cs 137 activities. Burnup values determined from both methods compared well with the values predicted from simulations. The highest measured burnup was 20.1% FIMA for the direct method and 20.0% FIMA for the ratio method (compared to 19.56% FIMA from simulations). An advantage of the ratio method is that the burnup of the cylindrical fuel compacts can determined in small (2.5 mm) axial increments and an axial burnup profile can be produced. Destructive chemical analysis by inductively coupled mass spectrometry (ICP MS) was then performed on selected compacts that were representative of the expected range of fuel burnups in the experiment to compare with the burnup values determined by gamma spectrometry. The compacts analyzed by mass spectrometry had a burnup range of 19.3% FIMA to 10.7% FIMA. The mass spectrometry evaluation of burnup for the four compacts agreed well with the gamma spectrometry burnup evaluations and the expected burnup from simulation. For all four compacts analyzed by mass spectrometry, the maximum range in the three experimentally determined values and the predicted value was 6% or less. Furthermore, the results confirm the accuracy of the nondestructive burnup evaluation from gamma spectrometry for TRISO fuel compacts across a burnup range of approximately 10 to 20% FIMA and also validate the approach used in the physics simulation of the AGR 1 experiment.
This brief report provides an update on FY24 efforts from the Acoustics team in the Instrumentation and Sensors technical area at Los Alamos National Laboratory to evaluate suitable data processing and modeling techniques for vibration-based defect localization.
An evaluation of nondestructive structural health monitoring methods was completed with over 132 documents, 37 specifically about wind turbines, summarized into a technology matrix. This matrix lists the technology, what can be monitored with this technology, and gives a short summary of the key aspects of the technology and its application. Passive and active acoustic emission equipment from Physical Acoustics Corp. and Acellent Technologies have been evaluated and selected for use in experimental state loading and fatigue tests of composite wind turbine blade materials. Acoustic Emission (AE) and Active Ultrasonic Testing (AUT), were applied to composite coupons with both simulated and actual damage. The results found that, while composites are more complicated in nature, compared to metallic structures, an artificial neural network analysis could still be used to determine damage. For the AE system, the failure mode could be determined (i.e. fiber breakage, delamination, etc.). The Acellent system has been evaluated to work well with composite materials. A test-rig for reliability testing of the rotating components was constructed. The research on the types of bearings used in the wind turbines indicated that in most of the designs, the main bearings utilized to support the shaft are cylindrical roller bearings. The accelerated degradation testing of a population of bearings was performed. Vibration and acoustic emission data was collected and analyzed in order to identify a representative degradation signal for each bearing to identify the initiation of the degradation process in the bearings. Afterwards, the RMS of the vibration signal from degradation initiation up to the end of the useful life of the bearing was selected to predict the remaining useful life of the bearing. This step included fitting Autoregressive Moving Average (ARMA) models to the degradation signals and approximating the probability distribution function (PDF) of remaining useful life based on the results of Monte-Carlo simulation of the ARMA models. This step was performed for different percentages of the degradation signal of each bearing. The accuracy of the proposed approach then was assessed by comparing the actual life of the bearing and the estimated life of the bearing from the developed models. The results were impressive and indicated that the accuracy of the models improved as more data was utilized in developing the ARMA models (we get closer to the end of the life of the bearing).
This paper assesses the feasibility of using eddy current nondestructive examination to determine flaw sizes in completely assembled hydrazine propellant tanks. The study was performed by the NASA Goddard Space Flight Center for the Tropical Rainfall Measuring Mission (TRMM) project to help determine whether existing propellant tanks could meet the fracture analysis requirements of the current pressure vessel specification, MIL-STD-1522A and, therefore be used on the TRMM spacecraft. After evaluating several nondestructive test methods, eddy current testing was selected as the most promising method for determining flaw sizes on external and internal surfaces of completely assembled tanks. Tests were conducted to confirm the detection capability of the eddy current NDE, procedures were developed to inspect two candidate tanks, and the test support equipment was designed. The non-spherical tank eddy current NDE test program was terminated when the decision was made to procure new tanks for the TRMM propulsion subsystem. The information on the development phase of this test program is presented in this paper as a reference for future investigation on the subject.
This paper assesses the feasibility of using eddy current nondestructive examination of determine flaw sizes in completely assembled hydrazine propellant tanks. The study was performed by the NASA Goddard Space Flight Center for the Tropical Rainfall Measuring Mission (TRMM) project to help determine whether existing propellant tanks could meet the fracture analysis requirements of the current pressure vessel specification, MIL-STD-1522A and, therefore be used on the TRMM spacecraft. After evaluating several nondestructive test methods, eddy current testing was selected as the most promising method for determining flaw sizes on external and internal surfaces of completely assembled tanks. Tests were conducted to confirm the detection capability of the eddy current NDE, procedures were developed to inspect two candidate tanks, and the test support equipment was designed. The non-spherical tank eddy current NDE test program was terminated when the decision was made to procure new tanks for the TRMM propulsion subsystem. The information on the development phase of this test program is presented in this paper as a reference for future investigation on the subject.
The Pacific Northwest National Laboratory (PNNL) in Richland, Washington, conducted initial studies to evaluate the effectiveness of nondestructive examinations (NDE) coupled with mechanical testing for assessing butt fusion joint integrity in high density polyethylene (HDPE) pipe. The work provided insightful information to the United States Nuclear Regulatory Commission (NRC) on the effectiveness of volumetric inspection techniques for detecting lack of fusion (LOF) conditions in the fusion joints. HDPE has been installed on a limited basis in American Society of Mechanical Engineers (ASME) Class 3, buried piping systems at several operating U.S. nuclear power plants and has been proposed for use in new construction. A comparison was made between the results from ultrasonic and microwave nondestructive examinations and the results from mechanical destructive evaluations, specifically the high-speed tensile test and the side-bend test, for determining joint integrity. The data comparison revealed that none of the NDE techniques detected all of the lack-of-fusion conditions that were revealed by the destructive tests. Follow-on work has recently been initiated at PNNL to accurately characterize the NDE responses from machined flaws of varying size and location in PE 4710 materials as well as the LOF condition. This effort is directed at quantifying the ability of volumetric NDE techniques to detect flaws in relation to the critical flaw size associated with joint integrity. A status of these latest investigations is presented.
Assessment and management of aging concrete structures in nuclear power plants require a more systematic approach than simple reliance on existing code margins of safety. Health monitoring of concrete structures is performed in order to understand the current condition of a structure based on heterogeneous measurements and then produce high confidence actionable information regarding structural integrity; this information can then be used to support operational and maintenance decisions. The paper describes a framework of research activities for the health monitoring of nuclear power plant concrete structures. The proposed framework consists of four elements: health monitoring, data analytics, uncertainty quantification, and prognosis. The goal of this framework is to enable plant operators to make risk-informed decisions on structural integrity, remaining useful life, and performance of concrete structures across the nuclear fleet. Among several concrete degradations, the research focuses on the degradation caused by the Alkali-Silica Reaction (ASR). ASR is a chemical reaction that in presence of sufficient moisture forms a gel that increases in volume and exerts an expansive pressure inside the material causing micro- to macro-cracks. The paper also presents development of controlled concrete samples with reactive aggregates to cause ASR degradation and application of different non-destructive evaluation techniques to detect the damage caused by ASR. Initial results are presented in the paper along with potential path forward.
Planar capacitor sensors have been proposed to measure the aging-related dielectric constant variation of the jacket or insulation materials of cables. Although capacitor sensors have been used to monitor the aging of cable insulation by removing the jacket, through the jacket measurement of cable insulation dielectric constant variation is difficult because once the sensor is placed on the jacket it would either measure the aging of the jacket or that of the jacket and insulation together. A reconfigurable sensor along with innovative cable-specific models could be used to determine the jacket and insulation aging using the same sensor. For the proposed novel reconfigurable sensor, the electric field penetration depth is changed by activating and deactivating PIN diode switches. In one instance, the sensor measures the dielectric constant variation of the jacket, while in the next, it measures the dielectric constant variation of both the jacket and the insulation. Here, by leveraging previously developed capacitance estimation models from large-scale finite element simulations for a specific cable, these two sets of measurement data are used to evaluate the aging-related dielectric constant variation of the insulation. Experimental data from aged cable specimens are presented to demonstrate the operation of the sensor.
The U.S. Nuclear Regulatory Commission (NRC) regulates the storage of used nuclear fuel, which is now and will be increasingly placed in dry storage systems. Since a final disposition pathway is not defined, the fuel is expected to be maintained in dry storage well beyond the time frame originally intended. Due to knowledge gaps regarding the viability of current dry storage systems for long term use, efforts are underway to acquire the technical knowledge and tools required to understand the issues and verify the integrity of the dry storage system components. This report summarizes the initial efforts performed by researchers at Idaho National Laboratory and Argonne National Laboratory to identify and evaluate approaches to in-situ inspection dry storage casks. This task is complicated by the design of the current storage systems that severely restrict access to the casks.
A study was performed on the effect of experimental variables on radiographic sensitivity (image quality) in x-ray micro-computed tomography images for a high density thin wall metallic cylinder containing micro-EDM holes. Image quality was evaluated in terms of signal-to-noise ratio, flaw detectability, and feature sharpness. The variables included: day-to-day reproducibility, current, integration time, voltage, filtering, number of frame averages, number of projection views, beam width, effective object radius, binning, orientation of sample, acquisition angle range (180deg to 360deg), and directional versus transmission tube.
Passive thermography is a large area inspection technique and is commonly used during fatigue loading of composite structures. Passive thermography allows for real time tracking of damage. This provides an accurate assessment of the damage progression as a function of load cycles and determines when the loading is stopped for ultrasonic or X-ray CT evaluations for detail damage assessment through-the-thickness. In addition, if new areas of damage growth are detected, with passive thermography, then those areas are additionally inspected with ultrasound or X-ray CT. A custom developed passive thermography inspection system for fatigue loading is presented. Passive thermography of damage progression is compared to ultrasound inspections as a function of the fatigue cycles. Discussion is made on processing of the thermal data for periodic and non-periodic thermal responses.
Materials issues are a key concern for the existing nuclear reactor fleet as material degradation can increase maintenance, downtime, and risk. Extending reactor life to 60 years and beyond will likely increase the reactor’s susceptibility to, and the severity of known forms of degradation. Additionally, new mechanisms of materials degradation are also possible. The purpose of the U.S. Department of Energy Office of Nuclear Energy’s Light Water Reactor Sustainability (LWRS) program is to develop technologies and other solutions that can improve the reliability, sustain the safety, and extend the operating lifetimes of nuclear power plants (NPPs) beyond 60 years.
An extension of the point kinetics model is developed in this paper to describe the neutron multiplicity response of a bare uranium object under interrogation by an associated particle imaging deuterium-tritium (D-T) measurement system. This extended model is used to estimate the total neutron multiplication of the uranium. Both MCNPX-PoliMi simulations and data from active interrogation measurements of highly enriched and depleted uranium geometries are used to evaluate the potential of this method and to identify the sources of systematic error. The detection efficiency correction for measured coincidence response is identified as a large source of systematic error. If the detection process is not considered, results suggest that the method can estimate total multiplication to within 13% of the simulated value. Values for multiplicity constants in the point kinetics equations are sensitive to enrichment due to (n, xn) interactions by D-T neutrons and can introduce another significant source of systematic bias. This can theoretically be corrected if isotopic composition is known a priori. Finally, the spatial dependence of multiplication is also suspected of introducing further systematic bias for high multiplication uranium objects.
The purpose of the non-destructive evaluation (NDE) R&D Roadmap for Cables is to support the Materials Aging and Degradation (MAaD) R&D pathway. The focus of the workshop was to identify the technical gaps in detecting aging cables and predicting their remaining life expectancy. The workshop was held in Knoxville, Tennessee, on July 30, 2012, at Analysis and Measurement Services Corporation (AMS) headquarters. The workshop was attended by 30 experts in materials, electrical engineering, U.S. Nuclear Regulatory Commission (NRC), U.S. Department of Energy (DOE) National Laboratories (Oak Ridge National Laboratory, Pacific Northwest National Laboratory, Argonne National Laboratory, and Idaho National Engineering Laboratory), NDE instrumentation development, universities, commercial NDE services and cable manufacturers, and Electric Power Research Institute (EPRI). The motivation for the R&D roadmap comes from the need to address the aging management of in-containment cables at nuclear power plants (NPPs).
NASA requires that NDE methods and inspectors demonstrate 90% Probability of Detection (POD) with 95% confidence for critical flaw sizes when inspecting fracture critical metallic components. NASA addresses the known variability of NDE inspector capability in two ways. The first, Special NDE, requires that every inspector demonstrate the required 90/95 POD, which is resource intensive. The second approach is Standard NDE for which conservative flaw sizes for different NDE methods are provided such that it is expected that most properly trained inspectors will exceed the 90/95 POD requirement. As such, individual POD demonstration testing is not required. The origin of NASA Standard NDE dates to the start of the Space Shuttle Program in the early 1970’s. In the first study to quantitatively assess NDE methods and inspectors, the performance of multiple inspectors was evaluated for different NDE methods using a large set of fatigue cracked specimens. A rudimentary POD analysis was performed to estimate the 90/95 POD flaw size for each inspector for each method. Additionally, the average and standard deviation of the 90/95 POD flaw size across the multiple inspectors was calculated to estimate the flaw size for which 95 percent of inspectors would provide the 90/95 POD capability. These estimated 90/95/95 POD flaw sizes evolved into the NASA Standard NDE flaw sizes still in use for structural analysis five decades later. The methodology for performing Standard NDE POD studies was never documented in NASA requirements. Furthermore, POD analysis methods have significantly evolved since this seminal study. Likewise, NDE methods have improved and there has been a push to reassess Standard NDE flaw sizes for existing methods, and to develop Standard NDE flaw sizes for new methods such as digital radiography. In this study, a Standard NDE POD methodology was developed and baselined using the historical data. This reanalysis of the historical data identified several deficiencies in the original test plan as well as an overall lack of conservatism in the estimated 90/95/95 POD flaw sizes. The results of this historical review and the new methodology are being incorporated into an update of NASA NDE POD requirements.