Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Next”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Initial Flowsheet for the Next Generation GSSX Process in the MCU: Report for FY2010

The Next Generation Caustic Side Solvent Extraction (NG-CSSX) flowsheet is being developed in a collaboration among Oak Ridge National Laboratory (ORNL), Argonne National Laboratory (ANL), and Savannah River National Laboratory (SRNL) for the Modular CSSX Unit (MCU) facility at the Savannah River Site (SRS). This work is being done in cooperation with two groups at SRS (my principal contacts there are Mark Geeting, SRR, and Sam Fink, SRNL) and with one group at Oak Ridge National Laboratory (my principal contact there is Bruce Moyer). The evaluation of the various NG-CSSX solvent candidates was done using the SASSE (Spreadsheet Algorithm for Stagewise Solvent Extraction) program with cesium distribution coefficient (D Cs ) values supplied by ORNL. The final optimized solvent composition has 50 mM MaxCalix as the extractant. Using the SASSE spreadsheet to calculate the Cs decontamination factor (D.F.) as well as ROTOR program to evaluate contactor rotor throughputs, an initial flowsheet was developed for the optimized NG-CSSX solvent. The current CSSX flowsheet for the MCU at its maximum salt feed flow rate is shown in Fig. 1. The initial NG-CSSX flowsheet for the MCU at its targeted maximum salt feed flow rate is shown in Fig. 2. Comparing these two flowsheets, one can see that, for the NG-CSSX flowsheet, the maximum flow rate of the salt feed (DF) is increased 41%, from 8.5 gpm to 12.0 gpm. At the same time, because of the high concentration of the MaxCalix extractant in the NG-CSSX solvent, the Cs decontamination factor (D.F.) for the aqueous effluent from the extraction section (DW, the aqueous raffinate) is increased from 12 to 40,000. As required, the Cs concentration factor (C.F.) for the aqueous effluent from the strip section (EW) is maintained at 15.

Leonard, Ralph↗

Next Generation Surfactants for Improved Chemical Flooding Technology

The principle objective of this project was to characterize and test current and next generation high performance surfactants for improved chemical flooding technology, focused on reservoirs in the Pennsylvanian-aged (Penn) sands. In order to meet this objective the characteristic curvatures (Cc) of twenty-eight anionic surfactants selected for evaluation for use in chemical flooding formulations were determined. The Cc values ranged from -6.90 to 2.55 with the majority having negative values. Crude oil samples from nine Penn sand reservoirs were analyzed for several properties pertinent to surfactant formulation for EOR application. These properties included equivalent alkane carbon numbers, total acid numbers, and viscosity. The brine samples from these same reservoirs were analyzed for several cations and for total dissolved solids. Surfactant formulations were successfully developed for eight reservoirs by the end of the project period. These formulations were comprised of a tertiary mixture of anionic surfactants. The identities of these surfactants are considered proprietary, but suffice to say the surfactants in each mixture were comprised of varying chemical structures. In addition to the successful development of surfactant formulations for EOR, there were also two successful single-well field tests conducted. There are many aspects that must be considered in the development and implementation of effective surfactant formulations. Taking into account these other aspects, there were four additional studies conducted during this project. These studies focused on the effect of the stability of surfactant formulations in the presence of polymers with an associated examination of polymer rheology, the effect of the presence of iron complexes in the brine on surfactant stability, the potential use of sacrificial agents in order to minimize the loss of surfactant to adsorption, and the effect of electrolytes on surfactant adsorption. In these last four studies the effects of such things as temperature, electrolyte concentration and the effect of different types of electrolytes were taken into consideration.

02 PETROLEUM↗

Sample Results from the Next Generation Solvent Program Real Waste Extraction-Scrub-Strip Testing

Savannah River National Laboratory (SRNL) performed multiple Extraction-Scrub-Strip (ESS) testing using real waste solutions, and three Next Generation Solvent (NGS) variations, which included radiologically clean pure NGS, a blend of radiologically clean NGS and radiologically clean BOBCalixC6 (NGS-MCU), and a blend of radiologically clean NGS and radiologically contaminated BOBCalixC6 from the MCU Solvent system. The results from the tests indicate that both the NGS and the NGS-MCU blend exhibit adequate extraction, scrub and strip behavior.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development Of Analytical Methods for Determining Suppressor Concentration in the MCU Next Generation Solvent (NGS)

Savannah River National Laboratory (SRNL) was tasked with identifying and developing at least one, but preferably two methods for quantifying the suppressor in the Next Generation Solvent (NGS) system. The suppressor is a guanidine derivative, N,N',N"-tris(3,7-dimethyloctyl)guanidine (TiDG). A list of 10 possible methods was generated, and screening experiments were performed for 8 of the 10 methods. After completion of the screening experiments, the non-aqueous acid-base titration was determined to be the most promising, and was selected for further development as the primary method. 1 H NMR also showed promising results from the screening experiments, and this method was selected for further development as the secondary method. Other methods, including 36 Cl radiocounting and ion chromatography, also showed promise; however, due to the similarity to the primary method (titration) and the inability to differentiate between TiDG and TOA (tri-n-ocytlamine) in the blended solvent, 1 H NMR was selected over these methods. Analysis of radioactive samples obtained from real waste ESS (extraction, scrub, strip) testing using the titration method showed good results. Based on these results, the titration method was selected as the method of choice for TiDG measurement. 1 H NMR has been selected as the secondary (back-up) method, and additional work is planned to further develop this method and to verify the method using radioactive samples. Procedures for analyzing radioactive samples of both pure NGS and blended solvent were developed and issued for the both methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mass Transfer And Hydraulic Testing Of The V-05 And V-10 Contactors With The Next Generation Solvent

The Modular Caustic Side Solvent Extraction (CSSX) Unit (MCU) facility is actively pursuing the transition from the current BOBCalixC6 based solvent to the Next Generation Solvent (NGS)-MCU solvent. To support this integration of NGS into the MCU facilities, Savannah River Remediation (SRR) requested that Savannah River National Laboratory (SRNL) perform testing of a blend of the NGS (MaxCalix based solvent) with the current solvent (BOBCalixC6 based solvent) for the removal of cesium (Cs) from the liquid salt waste stream. This testing differs from prior testing by utilizing a blend of BOBCalixC6 based solvent and the NGS with the full (0.05 M) concentration of the MaxCalix as well as a new suppressor, tris(3,7dimethyloctyl) guanidine. Single stage tests were conducted using the full size V-05 and V-10 centrifugal contactors installed at SRNL.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sample Results from the Next Generation Solvent Program Real Waste Extraction-Scrub-Strip Testing

Savannah River National Laboratory (SRNL) performed multiple Extraction-Scrub-Strip (ESS) testing using real waste solutions, and three Next Generation Solvent (NGS) variations, which included radiologically clean pure NGS, a blend of radiologically clean NGS and radiologically clean BOBCalixC6 (NGS-MCU), and a blend of radiologically clean NGS and radiologically contaminated BOBCalixC6 from the MCU Solvent system. The results from the tests indicate that both the NGS and the NGS-MCU blend exhibit adequate extraction, scrub and strip behavior.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results of Analysis of NGS Concentrate Drum Samples (Next Generation Solvent)

Savannah River National Laboratory (SRNL) prepared two drums (50 gallons each in Drum#2 and Drum#4) of NGS-MCU (Next Generation Solvent-Modular CSSX Unit) concentrate for future use at MCU in downblending the BOBCalixC6 based solvent to produce NGS-MCU solvent. Samples of each drum were sent for analysis. The results of all the analyses indicate that the blend concentrate is of the correct composition and should produce a blended solvent at MCU of the desired formulation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

DOE/NNSA Next‐Generation Safeguards Initiative: Presentations by MIIS-LLNL Safeguards Policy Interns

As part of its Next‐Generation Safeguards Initiative (NGSI), DOE/NNSA’s Office of Nuclear Safeguards and Security has funded each year since 2008 a summer internship program in International Safeguards Policy jointly organized by the James Martin Center for Nonproliferation Studies at the Monterey Institute of International Studies (MIIS) and the Lawrence Livermore National Laboratory (LLNL). Graduate students selected for the program first attend an intensive one‐week course in Monterey on International Safeguards Policy and then, with NNSA‐funded stipend support from MIIS, spend a 10‐week internship at LLNL learning more about international nuclear safeguards and interacting with LLNL mentors and other Laboratory staff. As one component of the internship experience, each intern undertakes a project designed to expand knowledge of international safeguards or other relevant nuclear nonproliferation topics, culminating in a final presentation and paper. Attached are slides from this year’s intern project presentations, held August 16, 2013 at LLNL and attended by LLNL staff and by Bryan Lee from CNS. In the course of their work at LLNL, students had access only to unclassified, open source information, and no classified or controlled information was used in their projects. The views and recommendations in the slides are strictly their own, and should not be construed to represent views or conclusions of Lawrence Livermore National Laboratory, the Department of Energy, the U.S. Government, or the MIIS James Martin Center for Nonproliferation Studies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advanced, High Power, Next Scale, Wave Energy Conversion Device

The project conducted under DOE contract DE-EE0002649 is defined as the Advanced, High Power, Next Scale, Wave Energy Converter. The overall project is split into a seven-stage, gated development program. The work conducted under the DOE contract is OPT Stage Gate III work and a portion of Stage Gate IV work of the seven stage product development process. The project effort includes Full Concept Design & Prototype Assembly Testing building on our existing PowerBuoy technology to deliver a device with much increased power delivery. Scaling-up from 150kW to 500kW power generating capacity required changes in the PowerBuoy design that addressed cost reduction and mass manufacturing by implementing a Design for Manufacturing (DFM) approach. The design changes also focused on reducing PowerBuoy Installation, Operation and Maintenance (IO&M) costs which are essential to reducing the overall cost of energy. In this design, changes to the core PowerBuoy technology were implemented to increase capability and reduce both CAPEX and OPEX costs. OPT conceptually envisaged moving from a floating structure to a seabed structure. The design change from a floating structure to seabed structure would provide the implementation of stroke unlimited Power Take-Off (PTO) which has a potential to provide significant power delivery improvement and transform the wave energy industry if proven feasible.

16 TIDAL AND WAVE POWER↗

Air-Cooled Condensers for Next Generation Geothermal Power Plants (Final Report)

This report summarizes the efforts performed under the ARRA project “Air-Cooled Condensers in Next Generation Conversion Systems”. This project examined technologies that provide near-term improvements to the performance of binary power plants utilizing air-cooled condensers. The motivation for pursuing these improvements is to reduce the power generation costs for enhanced geothermal system (EGS) resources. The study is based on two premises. • Water will not be readily available, and there will be no consumptive use of it in the surface energy conversion system. • The EGS resources utilized for power production will be at greater depths, requiring expensive wells to access the heat. In addition, these resources will have costs associated with the creation of the subsurface reservoir where heat that powers the energy conversion system is extracted. The costs associated with the well field development and EGS reservoir creation provide the impetus for using more efficient energy conversion systems, as well as conversion systems that have higher efficiencies at ‘off-design’ conditions. In identifying the more efficient conversion systems, this work focused on: • Existing technologies with the potential to increase conversion efficiency. These are commercially available technologies that are not typically used in plants operating on hydrothermal resources, • Design strategies to increase plant output during operation at higher ambient temperatures, as well as at ‘off-design’ conditions (operation at resource and ambient temperatures other than those for which the plant was designed), • The feasibility of using mixed working fluids in binary plants using air-cooled condensers. Mixtures have been shown to have the potential to increase binary plant performance by 10% to 20%. This project was originally proposed to also evaluate the use of air-cooled condensers in flash-steam geothermal plants. However, reduced funding subsequent to starting work resulted in elimination of that task.

15 GEOTHERMAL ENERGY↗

Synchronization System for Next Generation Light Sources

An alternative synchronization technique – one that would allow explicit control of the pulse train including its repetition rate and delay is clearly desired. We propose such a scheme. Our method is based on optical interferometry and permits synchronization of the pulse trains generated by two independent mode-locked lasers. As the next generation x-ray sources will be driven by a clock signal derived from a mode-locked optical source, our technique will provide a way to synchronize x-ray probe with the optical pump pulses.

43 PARTICLE ACCELERATORS↗

Results From The Salt Disposition Project Next Generation Solvent Demonstration Plan

Strip Effluent Hold Tank (SEHT), Decontaminated Salt Solution Hold Tank (DSSHT), Caustic Wash Tank (CWT) and Solvent Hold Tank (SHT) samples were taken throughout the Next Generation Solvent (NGS) Demonstration Plan. These samples were analyzed and the results are reported. SHT: The solvent behaved as expected, with no bulk changes in the composition over time, with the exception of the TOA and TiDG. The TiDG depletion is higher than expected, and consideration must be taken on the required rate of replenishment. Monthly sampling of the SHT is warranted. If possible, additional SHT samples for TiDG analysis (only) would help SRNL refine the TiDG degradation model. CWT: The CWT samples show the expected behavior in terms of bulk chemistry. The 137Cs deposited into the CWT varies somewhat, but generally appears to be lower than during operations with the BOBCalix solvent. While a few minor organic components were noted to be present in the Preliminary sample, at this time these are thought to be artifacts of the sample preparation or may be due to the preceding solvent superwash. DSSHT: The DSSHT samples show the predicted bulk chemistry, although they point towards significant dilution at the front end of the Demonstration. The 137Cs levels in the DSSHT are much lower than during the BOBCalix operations, which is the expected observation. SEHT: The SEHT samples represent the most different output of all four of the outputs from MCU. While the bulk chemistry is as expected, something is causing the pH of the SEHT to be higher than what would be predicted from a pure stream of 0.01 M boric acid. There are several possible different reasons for this, and SRNL is in the process of investigating. Other than the pH issue, the SEHT is as predicted. In summary, the NGS Demonstration Plan samples indicate that the MCU system, with the Blend Solvent, is operating as expected. The only issue of concern regards the pH of the SEHT, and SRNL is in the process of investigating this. SRNL results support the transition to routine operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Next Gen Safeguards Professional Network (Final Report 2014)

This report summarizes the 2014 Next Generation Safeguards Professional Network (NGSPN) meeting held at Sandia and Los Alamos National Laboratories. The meeting comprised two days at each laboratory and included facility tours, technology demonstrations, presentations, and networking opportunities to strengthen expertise in nuclear safeguards and nonproliferation.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗