Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

SU-E-T-239: Design and Evaluation of a Nozzle Shielding System in Passively Scattered Proton Therapy

Purpose: To design, implement and evaluate a shielding system that will reduce out-of-field dose experienced by the patient and associated electronic systems in passively scattered proton therapy treatment. Methods: A multi-stage neutron shielding system was retrofitted to the Gantry 1 treatment nozzle at Loma Linda University Medical Center. The system uses multiple borated polyethylene plates staged after the primary beam modifying devices to attenuate and absorb neutrons produced by such devices. This arrangement locates increasing levels of shielding between the sources of secondary particles in the nozzle and the patient. Additionally, the design of this shielding structure allows it to be easily retrofitted to an existing proton nozzle system without impacting design or treatment beam characteristics. The effectiveness of the shielding was evaluated both through experimental measurements and Geant4 Monte Carlo simulations. Results: Measurements were completed with Landauer Luxel+ dosimeters that use optically stimulated luminescence and CR-39 to detect fast neutrons, thermal neutrons, protons, photons and beta particles. Measurements of a 250 MeV proton beam indicated that the shielding system reduced out-of-field dose to the patient by almost half with dose equivalent values at 50 and 40 cm from the field edge decreasing from 0.965 and 1.262 mSv/Gy to 0.596 and 0.777 mSv/Gy respectively. The installation of the multi-stage shielding system also reduced dose equivalent experienced by electronic systems installed in the treatment room by up to 80%. Geant4 simulations were also used to evaluate the neutron fluence at various positions in the treatment room as well as provide information on microdosimetry spectra within the patient and treatment room. Conclusion: The shielding system described above proved to be an effective an inexpensive method of reducing out-of-field doses to the patient and electronic systems and can be easily retrofitted to existing passive scattering nozzles.

60 APPLIED LIFE SCIENCES↗

Joint IAEA/NNSA International Workshop Nuclear Forensics Methodologies for Practitioners 2013 Scenario Based Exercise – Version 4.0 Instructor’s Manual

[Participants will serve as border guards for Reimerland. They will be given brief instruction on the operation of hand-held RadioIsotope DetectorS (RIDS) and be provided an intelligence briefing that tells them to be on the lookout for suspicious activity at their post. Their instruction will include directing suspicious vehicles to a location for secondary screening. If, after secondary screening, suspicions of a criminal act involving nuclear and or radioactive materials remain, participants have been instructed to request assistance from the NLEA, who will then setup and manage a radiological crime scene. Participants will watch a demonstration of two vehicles containing radioactive materials driving through and setting off a portal monitor. The first vehicle, a semi-tractor trailer, sets off only a gamma alarm. After the driver provides a shipping manifest of fertilizer, participants, posing as border guards, are expected to waive this vehicle through inspection. The second vehicle, an SUV, set off both gamma and 2 neutron alarms. The alarming of the neutron monitor should prompt participants to set up a secondary inspection of the vehicle immediately. The driver of the vehicle indicates he is in legal possession of an industrial instrument containing an old 133Ba source that has decayed to a level no longer requiring official paperwork according to the IAEA and internationally accepted transportation regulations. Authorities have verified that the industrial source does fit the description of one that is sold commercially. However, upon setting up a secondary screening, participants will use hand-held detectors to locate several other radioactive sources emanating from a black duffle bag in the rear of the vehicle (Figure 1). Hand held detectors detect the presence of 133Ba, and Pu. Upon questioning, the driver only commits to having the 133Ba industrial source and cannot account for the detection of neutrons within his vehicle. Since neutron alarms also sounded, participants should indicate that a neutron alarm would be inconsistent with a 133Ba source alone and should therefore conclude further investigation is warranted. This will prompt participants to call in a response team from the NLEA to set up a radiological crime scene around the vehicle in question. The response team is able to shoot a 3-D X-ray radiograph of the duffle bag without moving it to ensure it is rendered safe and moveable without disturbing the contents in the field (Figure 2). At this point, the duffle bag is entered into inventory as evidence and a chain of custody form is initiated. Swipes are taken from the outer bag to confirm there is no dispersible contamination. The bag and its contents are considered valuable for the investigation by the lead investigator. He determines the duffle bag is safe to transport to RRL for evidence inventory and analysis. The duffle bag and its contents are packaged and sent off to the RRL.]

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Search for unbound Be 15 states in the 3 n + Be 12 channel

Background: Be-15 is expected to have low-lying 3/2(+) and 5/2(+) states. A first search did not find the 3/2(+) [A. Spyrou et al., Phys. Rev. C 84, 044309 (2011)]; however, a resonance in Be-15 was populated in a second attempt and determined to be unbound with respect to Be-14 by 1.8(1) MeV with a tentative spin-parity assignment of 5/2(+) [J. Snyder et al., Phys. Rev. C 88, 031303(R) (2013)]. Purpose: Search for the predicted Be-15 3/2(+) state in the three-neutron decay channel. Method: A two-proton removal reaction from a 55 MeV/u C-17 beam was used to populate neutron-unbound states in Be-15. The two-, three-, and four-body decay energies of the Be-12+ neutron(s) detected in coincidence were reconstructed using invariant mass spectroscopy. Monte Carlo simulations were performed to extract the resonance and decay properties from the observed spectra. Results: The low-energy regions of the decay energy spectra can be described with the first excited unbound state of Be-14 (E-x = 1.54 MeV, E-r = 0.28 MeV). Including a state in Be-15 that decays through the first excited Be-14 state slightly improves the fit at higher energies though the cross section is small. Conclusions: A Be-15 component is not needed to describe the data. If the 3/2(+) state in Be-15 is populated, the decay by three-neutron emission through Be-14 is weak,

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Kinetic mix at gas-shell interface in inverted corona fusion targets

Gas-filled, laser-driven “inverted corona” fusion targets have attracted interest as a low-convergence neutron source and platform for studying kinetic physics. At the fill pressures under investigation, ejected particles from the shell can penetrate deeply into the gas before colliding, leading to significant mixing across the gas–shell interface. Here, we use kinetic-ion, fluid-electron hybrid particle-in-cell simulations to explore the nature of that mix. Simulations of the system demonstrate characteristics of a weakly collisional electrostatic shock, whereby a strong electric field accelerates shell ions into the rarefied gas and reflects upstream gas ions. This interpenetration is mediated by collisional processes: At higher initial gas pressure, fewer shell particles pass into the mix region and reach the hotspot. This effect is detectable through neutron yield scaling vs gas pressure. Predictions of neutron yield scaling show excellent agreement with experimental data recorded at the OMEGA laser facility, suggesting that 1D kinetic mechanisms are sufficient to capture the mix process.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Unprecedented Properties of the First Electromagnetic Counterpart to a Gravitational-wave Source

We discovered Swope Supernova Survey 2017a (SSS17a) in the LIGO/Virgo Collaboration (LVC) localization volume of GW170817, the first detected binary neutron star (BNS) merger, only 10.9 hr after the trigger. No object was present at the location of SSS17a only a few days earlier, providing a qualitative spatial and temporal association with GW170817. Here, we quantify this association, finding that SSS17a is almost certainly the counterpart of GW170817, with the chance of a coincidence being ≤9×10{sup −6} (90% confidence). We arrive at this conclusion by comparing the optical properties of SSS17a to other known astrophysical transients, finding that SSS17a fades and cools faster than any other observed transient. For instance, SSS17a fades >5 mag in g within 7 days of our first data point, while all other known transients of similar luminosity fade by <1 mag during the same time period. Its spectra are also unique, being mostly featureless, even as it cools. The rarity of “SSS17a-like” transients combined with the relatively small LVC localization volume and recent non-detection imply the extremely unlikely chance coincidence. We find that the volumetric rate of SSS17a-like transients is ≤1.6×10{sup 4} Gpc{sup −3} yr{sup −1} and the Milky Way rate is ⩽0.19 per century. A transient survey designed to discover similar events should be high cadence and observe in red filters. The LVC will likely detect substantially more BNS mergers than current optical surveys will independently discover SSS17a-like transients, however a 1 day cadence survey with the Large Synoptic Survey Telescope (LSST) could discover an order of magnitude more events.

79 ASTRONOMY AND ASTROPHYSICS↗

A neutron diagnostic for high current deuterium beams

A neutron diagnostic for high current deuterium beams is proposed for installation on the spectral shear interferometry for direct electric field reconstruction (SPIDER, Source for Production of Ion of Deuterium Extracted from RF plasma) test beam facility. The proposed detection system is called Close-contact Neutron Emission Surface Mapping (CNESM). The diagnostic aims at providing the map of the neutron emission on the beam dump surface by placing a detector in close contact, right behind the dump. CNESM uses gas electron multiplier detectors equipped with a cathode that also serves as neutron-proton converter foil. The cathode is made of a thin polythene film and an aluminium film; it is designed for detection of neutrons of energy >2.2 MeV with an incidence angle < 45 deg. CNESM was designed on the basis of simulations of the different steps from the deuteron beam interaction with the beam dump to the neutron detection in the nGEM. Neutron scattering was simulated with the MCNPX code. CNESM on SPIDER is a first step towards the application of this diagnostic technique to the MITICA beam test facility, where it will be used to resolve the horizontal profile of the beam intensity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Demonstration of Early Warning Gravitational-wave Alerts

Gravitational-wave observations became commonplace in Advanced LIGO-Virgo's recently concluded third observing run. 56 nonretracted candidates were identified and publicly announced in near real time. Gravitational waves from binary neutron star mergers, however, remain of special interest since they can be precursors to high-energy astrophysical phenomena like γ-ray bursts and kilonovae. While late-time electromagnetic emissions provide important information about the astrophysical processes within, the prompt emission along with gravitational waves uniquely reveals the extreme matter and gravity during—and in the seconds following—merger. Rapid communication of source location and properties from the gravitational-wave data is crucial to facilitate multimessenger follow-up of such sources. This is especially enabled if the partner facilities are forewarned via an early warning (pre-merger) alert. Here we describe the commissioning and performance of such a low-latency infrastructure within LIGO-Virgo. We present results from an end-to-end mock data challenge that detects binary neutron star mergers and alerts partner facilities before merger. We set expectations for these alerts in future observing runs.

Ryan Magee↗

Cosmogenic Backgrounds in Borexino at 3800 m water-equivalent depth

The solar neutrino experiment Borexino, which is located in the Gran Sasso underground laboratories, is in a unique position to study muon-induced backgrounds in an organic liquid scintillator. In this study, a large sample of cosmic muons is identified and tracked by a muon veto detector external to the liquid scintillator, and by the specific light patterns observed when muons cross the scintillator volume. The yield of muon-induced neutrons is found to be Y{sub n} = (3.10±0.11)·10{sup −4} n/(μ·(g/cm{sup 2})). The distance profile between the parent muon track and the neutron capture point has the average value λ = (81.5±2.7) cm. Additionally the yields of a number of cosmogenic radioisotopes are measured for {sup 12}N, {sup 12}B, {sup 8}He, {sup 9}C, {sup 9}Li, {sup 8}B, {sup 6}He, {sup 8}Li, {sup 11}Be, {sup 10}C and {sup 11}C. All results are compared with Monte Carlo simulation predictions using the FLUKA and GEANT4 packages. General agreement between data and simulation is observed for the cosmogenic production yields with a few exceptions, the most prominent case being {sup 11}C yield for which both codes return about 50% lower values. The predicted μ-n distance profile and the neutron multiplicity distribution are found to be overall consistent with data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Center-of-Mass Corrections in Associated Particle Imaging

Associated particle imaging (API) utilizes the inelastic scattering of neutrons produced in deuterium-tritium (DT) fusion reactions to obtain 3-D isotopic distributions within an object. The locations of the inelastic scattering centers are calculated by measuring the arrival time and position of the associated alpha particle produced in the fusion reactions, and the arrival time of the prompt gamma created in the neutron scattering event. While the neutron and its associated particle move in opposite directions in the center-of-mass (COM) system, in the laboratory system the angle is slightly less than 180°, and the COM movement must be taken into account in the reconstruction of the scattering location. Furthermore, the fusion reactions are produced by ions of different momenta, and thus the COM velocity varies, resulting in an uncertainty in the reconstructed positions. In this article, we analyze the COM corrections to this reconstruction by simulating the energy loss of beam ions in the target material and identifying sources of uncertainty in these corrections. Here we show that an average COM velocity calculated using the ion beam direction and energy can be used in the reconstruction and discuss errors as a function of ion beam energy, composition, and alpha detection location. When accounting for the COM effect, the mean of the reconstructed locations can be considered a correctable systematic error leading to a shift/tilt in the reconstruction. However, the distribution of reconstructed locations also have a spread that will introduce an error in the reconstruction that cannot be corrected. In this article, we will use the known stopping powers of ions in materials and reaction cross sections to examine the reconstruction uncertainties. We also discuss the impact of this effect on our API system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron Interrogation System For Underwater Threat Detection And Identification

Wartime and terrorist activities, training and munitions testing, dumping and accidents have generated significant munitions contamination in the coastal and inland waters in the United States and abroad. Although current methods provide information about the existence of the anomaly (for instance, metal objects) in the sea bottom, they fail to identify the nature of the found objects. Field experience indicates that often in excess of 90% of objects excavated during the course of munitions clean up are found to be non-hazardous items (false alarm). The technology to detect and identify waterborne or underwater threats is also vital for protection of critical infrastructures (ports, dams, locks, refineries, and LNG/LPG). We are proposing a compact neutron interrogation system, which will be used to confirm possible threats by determining the chemical composition of the suspicious underwater object. The system consists of an electronic d-T 14-MeV neutron generator, a gamma detector to detect the gamma signal from the irradiated object and a data acquisition system. The detected signal then is analyzed to quantify the chemical elements of interest and to identify explosives or chemical warfare agents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SEQUOIA: A Newly Operating Chopper Spectrometer at the SNS

A fine resolution chopper spectrometer (SEQUOIA) recently received first neutronsat the SNS. The commissioning phase of the instrument is underway. SEQUOIA is designedto utilize neutrons of an incident energy (Ei) between 10-2000 meV. A monochromatic beamis provided on a sample, 20 m from the decoupled ambient temperature H2O moderator, byfiltering the white beam with a Fermi chopper located 18 m from the source. After interactingwith the sample, neutrons are detected by an array of 3He linear position sensitive tubes locatedon a vertical cylinder with a radius of 5.5 m. This contribution presents current results from thecommissioning experiments and compares SEQUOIA’s actual and predicted performance. Thesecommissioning experiments include characterization of the beam by monitors, determination ofthe chopper phase offsets, and runs with V and C4H2I2S. The predicted performance is providedby analytical calculations and Monte Carlo simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Compound pulse characteristics of a heterogeneous composite scintillator in a gamma-ray field

An important aspect of radiation detection in scintillators is the time dependence of emitted fluorescence, which results in characteristic measured pulse shape. In some materials, a relatively strong dependence of the scintillation pulse shape on stopping power exists, which can provide reliable identification of the incident particle. An alternative method to realize particle identification is by combining materials with different fluorescence lifetimes into heterogeneous structures. Such composite scintillators derive their properties from both the constituent material characteristics and the geometry of the composite structure. In composite scintillators with a high degree of heterogeneous loading, a superposition of fluorescence contributions originating in multiple materials, which is observed as single waveform with an intermediate pulse shape, may affect its ability to reject rays. We measure the time dependence of light output from a scintillator composed of 6 Li-containing glass shards and scintillating polyvinyl toluene and identify events that exhibit such compound behavior when exposed to rays and fast neutrons. We develop a modeling and simulation framework that reproduces the pulse shapes in heterogeneous scintillators and use it study the effect that the weight percentage of 6 Li glass has on rejection. The modeling framework is applied to the experimentally studied scintillator, finding a good agreement. Here, the developed modeling and simulation approach will help optimize the design of heterogeneous scintillators to meet the desired trade-o between neutron capture efficiency and -ray rejection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The impact of detection rate changes and correlations on random-coincidence background measurements

Coincidence detection of multiple particles emitted during an experiment can yield a new depth of understanding of the underlying process under study. However, the probability of detecting particles that are generated from the same physical event within a given coincidence time window is generally much lower than that of detecting particles that appear in the same coincidence time window, but were not created from the same physical event, and are therefore detected randomly in coincidence with each other. Thus, accurate and precise methods of measuring this random-coincidence background are essential for a wide variety of fields of science. A method to determine this background directly using the data themselves without any additional experimental run time or fake signals introduced in the data was recently established (O’Donnell, 2016). This method yields a statistical uncertainty on the random-coincidence background that is orders of magnitude smaller than that of the true coincidence data, though the potential for systematic errors of backgrounds from this method was never explored. In this work, we discuss common varieties of correlated and uncorrelated changes in the detection rates of each particle detected in an experiment. Here we demonstrate here that a correlation between particle detection rates from, for example, an incident particle beam that initiates a physical process of interest, creates systematic errors in the random-coincidence background measurement. We also discuss the impact of a variety of other realistic scenarios for rate changes in experiments. Lastly, a method is introduced to correct for errors in the random-coincidence background from any source, yielding an optimization between statistical precision and eliminating potential lingering systematic errors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast heating of fuel assembled in a spherical deuterated polystyrene shell target by counter-irradiating tailored laser pulses delivered by a HAMA 1 Hz ICF driver

Fast heating is a method of heating an assembled high-density plasma into a hot state by irradiating it with short-duration (sub-picosecond), high-intensity ($>$ $10^{18}$ W ${\rm cm}^{-2}$ ) laser pulses before the plasma expands and dissolves hydrodynamically. In this paper, we present detailed experimental results of fast heating fuel assembled in a spherical deuterated polystyrene shell target of 500 ${\mu}$ m diameter and 7 μm thickness with counterbeam illumination by using a HAMA 1 Hz, 5.9 J inertial confinement fusion laser driver with pulse tailoring. These tailored pulses contain three pulses in sequence: a 'foot' pulse of 2.4 J/25 ns, a 'spike' pulse of 0.5 J/300 ps and a 'heater' pulse of 0.4 J/110 fs; these pulses are designed to assemble the fuel and heat it. By varying the energy of the foot pulse, we find that fast heating the fuel is achieved only if the fuel is weakly ablated by the foot pulse and then shock-assembled by the spike pulse into the target centre so that the heater pulse can access the fuel with a focal intensity greater than $10^{18}$ W ${\rm cm}^{-2}$ . Without a foot pulse, the heater pulse contributes to assembling the fuel. For higher foot-pulse energies, the heater pulse drives a hydrodynamic motion with speeds of the order 107 cm ${\rm s}^{-1}$ with intensities of the order $10^{17}$ W ${\rm cm}^{-2}$ , resulting in re-assembling and additional heating of the pre-assembled fuel. Once a shock-assembled core is achieved at the target centre, we succeed qualitatively in fast heating the core for shots in sequence with variations of laser energy within 18%. The coupling efficiency from the heating laser to the core is inferred to be $(10 \pm 2)$ % in total: $(8 \pm 1.6)$ % for the ionized bulk electrons and $(2 \pm 0.4)$ % for the bulk ions. The fusion neutron spectrum detected on the laser axis exhibits peaks at 1.0 MeV, 1.7 MeV and 3.8 MeV. These peaks are attributed to the $C(d, n){\hspace{0pt}}^{13}$ N and $d(d, n){\hspace{0pt}}^3$ He reactions induced by counterpropagating fast deuterons accelerated by the photon pressure of the heating pulses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

( d , n ) proton-transfer reactions on Be 9 , B 11 , C 13 , N 14 , 15 , and F 19 and spectroscopic factors at E d = 16 MeV

The (d,n) reaction has been studied with targets of 9 Be, 11 B, 13 C, 14,15 N, and 19F at E d = 16MeV using a deuterated liquid-scintillator array. Advanced spectral unfolding techniques with accurately measured scintillator response functions were employed to extract neutron energy spectra without the need for long-path neutron time-of-flight. An analysis of the proton-transfer data at forward angles to the ground states of the final nuclei, using finite-range distorted-wave Born approximation analysis with common bound-state, global, and local optical-model parameter sets, yields a set of self-consistent spectroscopic factors. These are compared with the results of several previous time-of-flight measurements, most done many years ago for individual nuclei at lower energy and often analyzed using zero-range transfer codes. In contrast to some of the earlier published data, our data generally compare well with simple shell-model predictions, with little evidence for uniform quenching (reduction from shell-model values) that has previously been reported from analysis of nucleon knock-out reactions. Data for low-lying excited states in 14 N from 13 C(d,n) also is analyzed and spectroscopic information relevant to nuclear astrophysics obtained. Here, a preliminary study of the radioactive ion beam induced reaction 7 Be(d,n), E( 7 Be) = 30MeV was carried out and indicates further improvements are needed for such measurements, which require detection of neutrons with E n < 2MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First observation of the splittings of the E1 p-wave amplitudes in low energy deuteron photodisintegration and its implications for the Gerasimov-Drell-Hearn Sum Rule integrand

Angular distributions of the cross section and linear analyzing powers have been measured for the d({gamma}-vector,n)p reaction at the High Intensity {gamma}-ray Source with linearly polarized beams of 14 and 16 MeV. The outgoing neutrons were detected using the Blowfish detector array, consisting of 88 liquid scintillator detectors with large solid angle coverage. The amplitudes of the reduced transition matrix elements were extracted by means of fits to the data and good agreement was found with a recent potential model calculation of the splittings of the triplet p-wave amplitudes. The extracted amplitudes are used to reconstruct the Gerasimov-Drell-Hearn sum rule integrand for the deuteron and are compared to theory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

TREAT Fuel Motion Summary Report. SETH A-E Experiments

In support of the Accident Tolerant Fuels program, experiment devices are being developed to enable transient testing of pressurized water reactor (PWR) type fuel specimens. In fiscal year 2019 several fueled tests were conducted in the Transient Reactor Test Facility (TREAT) using the Separate Effects Test Holder (SETH). Five different SETH capsules (SETH A-E) were assembled, each holding a 10-pellet rodlet with 4.9% enriched, commercially-produced fresh UO2 pellets in zirconium alloy cladding with pellet dimensions having typical PWR radial dimensions and a total pellet stack length measuring 10.16 cm. The rodlet’s length allows the specimen to be axially positioned in the center of the core with minimal flux variation over the height of the rodlet. The fuel motion monitoring system (FMMS) is located on the north side of the TREAT reactor. Having direct line-of-sight of the core enables the FMMS to collect spatially-resolved data for fast neutrons generated due to fission occurring in experiment specimens. The FMMS contains 360 channels that make up a 10 (horizontal) by 36 (vertical) array of viewing slots; for the SETH A-E test series 96 proton-recoil scintillator (PRS) detectors were installed in the system. The fast neutrons are detected in the PRS detectors from light produced by the recoil of protons interacting with ZnS(Ag) grains in each detector's scintillator button. This report focuses on the FMMS data captured in the SETH A-E experiments, with multiple transients varying in reactivity addition and length. The first three experiments had a total reactor energy of 101 MJ each and were critical in understanding the FMMS field of view, lead shielding, and other TREAT data acquisition systems. SETH-B2 and C had a reactivity addition of almost double the previous transients and served as a demonstration of the detector array behavior under increased reactor energy. The final two SETH experiments (D and E) were aimed at reaching cladding melting temperatures with a reactor energy over 500 MJ for each test. In preparation for the higher energy transients, the FMMS lead shielding was reduced to 0.5 inches from the 6 inches used in SETH A-C. This was expected to saturate the detectors at the peak of the transient in exchange for higher sensitivity at lower energies after the peak, when the motion was expected. SETH-D was clipped at approximately 3 seconds, which was too early for the FMMS to capture any rodlet motion. SETH-E had the same reactivity addition as SETH-D but the transient time was extended to 18 seconds. The FMMS captured the downward motion of the rodlet in SETH-E as the count rate significantly changed for the detectors viewing the specimen. Snapshots taken throughout the transient helped identify the approximate time at which the motion initiated. Further analysis of the individual detector data captured on a per-millisecond time basis resulted in a determination that the approximate time for the onset of the downward motion was 2.84 ± 0.02 seconds. Neutron radiographs confirmed that downward motion occurred for SETH-D and SETH-E. Motion in SETH-D could also have been captured by the FMMS if the transient time had been longer for SETH-D. Ultimately, these final two tests served to demonstrate the FMMS's ability to track fuel motion during transient experiments at TREAT.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of High Gradient Laser Wakefield Accelerators Towards Nuclear Detection Applications at LBNL

Compact high-energy linacs are important to applications including monochromatic gamma sources for nuclear material security applications. Recent laser wakefield accelerator experiments at LBNL demonstrated narrow energy spread beams, now with energies of up to 1 GeV in 3 cm using a plasma channel at low density. This demonstrates the production of GeV beams from devices much smaller than conventional linacs, and confirms the anticipated scaling of laser driven accelerators to GeV energies. Stable performance at 0.5 GeV was demonstrated. Experiments and simulations are in progress to control injection of particles into the wake and hence to improve beam quality and stability. Using plasma density gradients to control injection, stable beams at 1 MeV over days of operation, and with an order of magnitude lower absolute momentum spread than previously observed, have been demonstrated. New experiments are post-accelerating the beams from controlled injection experiments to increase beam quality and stability. Thomson scattering from such beams is being developed to provide collimated multi-MeV monoenergetic gamma sources for security applications from compact devices. Such sources can reduce dose to target and increase accuracy for applications including photofission and nuclear resonance fluorescence.

43 PARTICLE ACCELERATORS↗