Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Monte Carlo Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Irradiated Low-Enriched Uranium Fuel Measurements with a Gamma-Ray Scanning System

A gamma-ray scanning system was designed to perform post-irradiation measurements of nuclear fuel at Idaho National Laboratory (INL). The system is composed of a coaxial high-purity germanium (HPGe) detector, a collimator, and mechanical positioning stages that translate the fuel sample across the front of the collimator. A Monte Carlo N-Particle code simulation of the system and the fuel were created with vendor-supplied design specifications, dimensional measurements, and x-ray radiographs of the HPGe detector as well as all available fuel specifications. Benchmark measurements were performed by scanning an irradiated fuel rodlet containing eight pellets of 0.74% enriched UO2 in zirconium alloy. This fuel rodlet was part of the Static Environment Rodlet Transient Test Apparatus (SERTTA) testing campaign in the Transient Reactor Test Facility (TREAT). These results were compared to simulated spectra to help characterize the detector model and establish fidelity. A goal of the system is to determine the number of fissions per gram of UO2 in the fuel. This paper documents the modeling of the system and the calculation of the number of fissions per gram along the axial length of the SERTTA-C rodlet.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of Irradiated Low Enriched Fuel with a Gamma-Ray Scanning System (ANIMMA 2023 Conference Presentation)

A gamma-ray scanning system was designed to perform post-irradiation measurements of nuclear fuel at Idaho National Laboratory (INL). The system is composed of a coaxial high-purity germanium (HPGe) detector, a collimator, and mechanical positioning stages that translate the fuel sample across the front of the collimator. A Monte Carlo N-Particle code simulation of the system and the fuel were created with vendor-supplied design specifications, dimensional measurements, and x-ray radiographs of the HPGe detector as well as all available fuel specifications. Benchmark measurements were performed by scanning an irradiated fuel rodlet containing eight pellets of 0.74% enriched UO2 in zirconium alloy. This fuel rodlet was part of the Environment Rodlet Transient Test Apparatus (SERTTA) testing campaign in the Transient Reactor Test Facility (TREAT). These results were compared to simulated spectra to help characterize the detector model and establish fidelity. One goal of the system is to determine the number of fissions per gram of UO2 in the fuel. This article documents the modeling, benchmarking measurements, and the calculated number of fissions per gram in the SERTTA-A rodlet which was previously irradiated at TREAT.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dark Energy Survey Year 3 results: marginalization over redshift distribution uncertainties using ranking of discrete realizations

ABSTRACT Cosmological information from weak lensing surveys is maximized by sorting source galaxies into tomographic redshift subsamples. Any uncertainties on these redshift distributions must be correctly propagated into the cosmological results. We present hyperrank, a new method for marginalizing over redshift distribution uncertainties, using discrete samples from the space of all possible redshift distributions, improving over simple parametrized models. In hyperrank, the set of proposed redshift distributions is ranked according to a small (between one and four) number of summary values, which are then sampled, along with other nuisance parameters and cosmological parameters in the Monte Carlo chain used for inference. This approach can be regarded as a general method for marginalizing over discrete realizations of data vector variation with nuisance parameters, which can consequently be sampled separately from the main parameters of interest, allowing for increased computational efficiency. We focus on the case of weak lensing cosmic shear analyses and demonstrate our method using simulations made for the Dark Energy Survey (DES). We show that the method can correctly and efficiently marginalize over a wide range of models for the redshift distribution uncertainty. Finally, we compare hyperrank to the common mean-shifting method of marginalizing over redshift uncertainty, validating that this simpler model is sufficient for use in the DES Year 3 cosmology results presented in companion papers.

79 ASTRONOMY AND ASTROPHYSICS↗

Features of the application of the Monte Carlo method to calculations for large RBMK reactors and to model correction on the basis of data from in-core detectors

Statistical errors in sampling neutron fields in physically large systems like an RBMK are analyzed both qualitatively and quantitatively. Recommendations concerning the choice of parameters for calculations are given. A new procedure for Monte Carlo RBMK calculations with model corrections on the basis of data from in-core detectors is proposed. Dedicated software based on the CUDA software and hardware platform is developed for computational research. Results of testing the procedure and software in question via calculations for real RBMK reactors are discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Advanced Multilevel Monte Carlo Methods

This article reviews the application of some advanced Monte Carlo techniques in the context of multilevel Monte Carlo (MLMC). MLMC is a strategy employed to compute expectations, which can be biassed in some sense, for instance, by using the discretization of an associated probability law. The MLMC approach works with a hierarchy of biassed approximations, which become progressively more accurate and more expensive. Additionally, using a telescoping representation of the most accurate approximation, the method is able to reduce the computational cost for a given level of error versus i.i.d. sampling from this latter approximation. All of these ideas originated for cases where exact sampling from couples in the hierarchy is possible. This article considers the case where such exact sampling is not currently possible. We consider some Markov chain Monte Carlo and sequential Monte Carlo methods, which have been introduced in the literature, and we describe different strategies that facilitate the application of MLMC within these methods.

97 MATHEMATICS AND COMPUTING↗

A Monte Carlo study of reflection electron energy loss spectroscopy spectrum of a carbon contaminated surface

It has been experimentally found that the carbon surface contamination influences strongly the spectrum signals in reflection electron energy loss spectroscopy (REELS) especially at low primary electron energy. However, there is still little theoretical work dealing with the carbon contamination effect in REELS. Such a work is required to predict REELS spectrum for layered structural sample, providing an understanding of the experimental phenomena observed. In this study, we present a numerical calculation result on the spatially varying differential inelastic mean free path for a sample made of a carbon contamination layer of varied thickness on a SrTiO{sub 3} substrate. A Monte Carlo simulation model for electron interaction with a layered structural sample is built by combining this inelastic scattering cross-section with the Mott's cross-section for electron elastic scattering. The simulation results have clearly shown that the contribution of the electron energy loss from carbon surface contamination increases with decreasing primary energy due to increased individual scattering processes along trajectory parts carbon contamination layer. Comparison of the simulated spectra for different thicknesses of the carbon contamination layer and for different primary electron energies with experimental spectra clearly identifies that the carbon contamination in the measured sample was in the form of discontinuous islands other than the uniform film.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

TYPE Ia SUPERNOVA LIGHT-CURVE INFERENCE: HIERARCHICAL BAYESIAN ANALYSIS IN THE NEAR-INFRARED

We present a comprehensive statistical analysis of the properties of Type Ia supernova (SN Ia) light curves in the near-infrared using recent data from Peters Automated InfraRed Imaging TELescope and the literature. We construct a hierarchical Bayesian framework, incorporating several uncertainties including photometric error, peculiar velocities, dust extinction, and intrinsic variations, for principled and coherent statistical inference. SN Ia light-curve inferences are drawn from the global posterior probability of parameters describing both individual supernovae and the population conditioned on the entire SN Ia NIR data set. The logical structure of the hierarchical model is represented by a directed acyclic graph. Fully Bayesian analysis of the model and data is enabled by an efficient Markov Chain Monte Carlo algorithm exploiting the conditional probabilistic structure using Gibbs sampling. We apply this framework to the JHK{sub s} SN Ia light-curve data. A new light-curve model captures the observed J-band light-curve shape variations. The marginal intrinsic variances in peak absolute magnitudes are sigma(M{sub J}) = 0.17 +- 0.03, sigma(M{sub H}) = 0.11 +- 0.03, and sigma(M{sub Ks}) = 0.19 +- 0.04. We describe the first quantitative evidence for correlations between the NIR absolute magnitudes and J-band light-curve shapes, and demonstrate their utility for distance estimation. The average residual in the Hubble diagram for the training set SNe at cz > 2000kms{sup -1} is 0.10 mag. The new application of bootstrap cross-validation to SN Ia light-curve inference tests the sensitivity of the statistical model fit to the finite sample and estimates the prediction error at 0.15 mag. These results demonstrate that SN Ia NIR light curves are as effective as corrected optical light curves, and, because they are less vulnerable to dust absorption, they have great potential as precise and accurate cosmological distance indicators.

79 ASTRONOMY AND ASTROPHYSICS↗

Robust Importance Sampling for Bayesian Model Calibration with Spatio-Temporal Data

This paper addresses two challenges in Bayesian calibration: 1) computational speed of existing sampling algorithms, and 2) calibration with spatio-temporal responses. The commonly used Markov Chain Monte Carlo (MCMC) approaches require many sequential model evaluations making the computational expense prohibitive. This paper proposes an efficient sampling algorithm: iterative importance sampling with genetic algorithm (IISGA). While iterative importance sampling enables computational efficiency, the genetic algorithm enables robustness by preventing sample degeneration and avoids getting stuck in multimodal search spaces. An inflated likelihood further enables robustness in high-dimensional parameter spaces by enlarging the target distribution. Spatio-temporal data complicate both surrogate modeling, which is necessary for expensive computational models, and the likelihood estimation. In this work, singular value decomposition is investigated for reducing the high-dimensional field data to a lower-dimensional space prior to Bayesian calibration. Then the likelihood is formulated and Bayesian inference is performed in the lower-dimension, latent space. An illustrative example is provided to demonstrate IISGA relative to existing sampling methods, and then IISGA is employed to calibrate a thermal battery model with 26 uncertain calibration parameters and spatio-temporal response data.

97 MATHEMATICS AND COMPUTING↗

The influence of the ionizer geometry on the absolute density calibration of reactive neutral species in a molecular beam mass spectrometry

Molecular beam mass spectrometry is a powerful diagnostic technique, which can be used for the measurement of absolute number densities of reactive species in non-equilibrium reactive plasmas. However, the calibration of absolute number densities is susceptible to systematic errors. Critical issues are the proper design of the sampling system and the correction of the background signal. Here we discuss the effect of reflections of particles from the molecular beam in an ionizer, formation of additional background particle density in the ionizer, and its effect on the density calibration of reactive particle densities. A Monte Carlo simulation of particle trajectories in the ionizer is used to estimate the detection probability of a beam particle after the collision with the ionizer wall. The simulation shows that as much as two-third of the signal can be due to scattered particles in the commercially available mass spectrometers. This effect leads to systematic underestimation of densities of reactive particles, which are reactive at the surface and, therefore, do not have any background density. A simple change in the ionizer geometry is suggested, which can significantly reduce this problem.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Iterative Importance Sampling Algorithms for Parameter Estimation

In parameter estimation problems one computes a posterior distribution over uncertain parameters defined jointly by a prior distribution, a model, and noisy data. Markov chain Monte Carlo (MCMC) is often used for the numerical solution of such problems. An alternative to MCMC is importance sampling, which can exhibit near perfect scaling with the number of cores on high performance computing systems because samples are drawn independently. However, finding a suitable proposal distribution is a challenging task. Several sampling algorithms have been proposed over the past years that take an iterative approach to constructing a proposal distribution. We investigate the applicability of such algorithms by applying them to two realistic and challenging test problems, one in subsurface flow, and one in combustion modeling. More specifically, we implement importance sampling algorithms that iterate over the mean and covariance matrix of Gaussian or multivariate t-proposal distributions. Our implementation leverages massively parallel computers, and we present strategies to initialize the iterations using “coarse” MCMC runs or Gaussian mixture models.

97 MATHEMATICS AND COMPUTING↗

Fast and scalable quantum Monte Carlo simulations of electron-phonon models

We introduce methodologies for highly scalable quantum Monte Carlo simulations of electron-phonon models, and report benchmark results for the Holstein model on the square lattice. The determinant quantum Monte Carlo (DQMC) method is a widely used tool for simulating simple electron-phonon models at finite temperatures, but incurs a computational cost that scales cubically with system size. Alternatively, near-linear scaling with system size can be achieved with the hybrid Monte Carlo (HMC) method and an integral representation of the Fermion determinant. Here, we introduce a collection of methodologies that make such simulations even faster. To combat "stiffness" arising from the bosonic action, we review how Fourier acceleration can be combined with time-step splitting. To overcome phonon sampling barriers associated with strongly-bound bipolaron formation, we design global Monte Carlo updates that approximately respect particle-hole symmetry. To accelerate the iterative linear solver, we introduce a preconditioner that becomes exact in the adiabatic limit of infinite atomic mass. Finally, we demonstrate how stochastic measurements can be accelerated using fast Fourier transforms. Here, these methods are all complementary and, combined, may produce multiple orders of magnitude speedup, depending on model details.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Advances in the Assessment of Wind Turbine Operating Extreme Loads via More Efficient Calculation Approaches

A new adaptive stratified importance sampling (ASIS) method is proposed as an alternative approach for the calculation of the 50 year extreme load under operational conditions, as in design load case 1.1 of the the International Electrotechnical Commission design standard. ASIS combines elements of the binning and extrapolation technique, currently described by the standard, and of the importance sampling (IS) method to estimate load probability of exceedances (POEs). Whereas a Monte Carlo (MC) approach would lead to the sought level of POE with a daunting number of simulations, IS-based techniques are promising as they target the sampling of the input parameters on the parts of the distributions that are most responsible for the extreme loads, thus reducing the number of runs required. We compared the various methods on select load channels as output from FAST, an aero-hydro-servo-elastic tool for the design and analysis of wind turbines developed by the National Renewable Energy Laboratory (NREL). Our newly devised method, although still in its infancy in terms of tuning of the subparameters, is comparable to the others in terms of load estimation and its variance versus computational cost, and offers great promise going forward due to the incorporation of adaptivity into the already powerful importance sampling concept.

17 WIND ENERGY↗

MO-FG-BRA-01: 4D Monte Carlo Simulations for Verification of Dose Delivered to a Moving Anatomy

Purpose: To validate 4D Monte Carlo (MC) simulations of dose delivery by an Elekta Agility linear accelerator to a moving phantom. Methods: Monte Carlo simulations were performed using the 4DdefDOSXYZnrc/EGSnrc user code which samples a new geometry for each incident particle and calculates the dose in a continuously moving anatomy. A Quasar respiratory motion phantom with a lung insert containing a 3 cm diameter tumor was used for dose measurements on an Elekta Agility linac with the phantom in stationary and moving states. Dose to the center of tumor was measured using calibrated EBT3 film and the RADPOS 4D dosimetry system. A VMAT plan covering the tumor was created on the static CT scan of the phantom using Monaco V.5.10.02. A validated BEAMnrc model of our Elekta Agility linac was used for Monte Carlo simulations on stationary and moving anatomies. To compare the planned and delivered doses, linac log files recorded during measurements were used for the simulations. For 4D simulations, deformation vectors that modeled the rigid translation of the lung insert were generated as input to the 4DdefDOSXYZnrc code as well as the phantom motion trace recorded with RADPOS during the measurements. Results: Monte Carlo simulations and film measurements were found to agree within 2mm/2% for 97.7% of points in the film in the static phantom and 95.5% in the moving phantom. Dose values based on film and RADPOS measurements are within 2% of each other and within 2σ of experimental uncertainties with respect to simulations. Conclusion: Our 4D Monte Carlo simulation using the defDOSXYZnrc code accurately calculates dose delivered to a moving anatomy. Future work will focus on more investigation of VMAT delivery on a moving phantom to improve the agreement between simulation and measurements, as well as establishing the accuracy of our method in a deforming anatomy. This work was supported by the Ontario Consortium of Adaptive Interventions in Radiation Oncology (OCAIRO), funded by the Ontario Research Fund Research Excellence program.

60 APPLIED LIFE SCIENCES↗

Sputter deposition of ultrathick Bi coatings onto rotating substrates for inertial confinement fusion

Sputter-deposited Bi is a potential candidate material for the production of inertial confinement fusion (ICF) hohlraums, which are sphero-cylindrical canisters that serve as the housing for hydrogen-fuel-filled capsules in ICF implosions. The fabrication of hohlraums involves deposition onto rotating sphero-cylindrical substrates and, hence, requires an understanding of oblique angle deposition phenomena. Here, we systematically study the effect of dynamic substrate tilt on properties of Bi films deposited onto rotating planar substrates. Results show that film morphology, porosity, and electrical resistivity depend on substrate tilt. In comparison with films deposited onto substrates adhered to a stationary sample holder, films deposited on rotating substrates have more uniform microstructure with fewer void defects. Based on Monte Carlo simulations, these changes in film morphology and microstructure are attributed to averaging and geometric effects related to sample position and rotation. In conclusion, the fabrication of an ∼ 50-µm-thick Bi film on a rotating sphero-cylindrical mandrel demonstrates a significant step toward the production of Bi hohlraums.

Bismuth↗

The new cold neutron chopper spectrometer at the Spallation Neutron Source: Design and performance

The design and performance of the new cold neutron chopper spectrometer (CNCS) at the Spallation Neutron Source in Oak Ridge are described. CNCS is a direct-geometry inelastic time-of-flight spectrometer, designed essentially to cover the same energy and momentum transfer ranges as IN5 at ILL, LET at ISIS, DCS at NIST, TOFTOF at FRM-II, AMATERAS at J-PARC, PHAROS at LANSCE, and NEAT at HZB, at similar energy resolution. Measured values of key figures such as neutron flux at sample position and energy resolution are compared between measurements and ray tracing Monte Carlo simulations, and good agreement (better than 20% of absolute numbers) has been achieved. The instrument performs very well in the cold and thermal neutron energy ranges, and promises to become a workhorse for the neutron scattering community for quasielastic and inelastic scattering experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effects of applied current on one-dimensional interdiffusion between copper and nickel in spark plasma sintering

Spark plasma sintering (SPS) is a powder metallurgy technique that employs the use of fast sintering kinetics to produce final consolidated components in a matter of minutes. In order to use blended powders in SPS to obtain fully alloyed parts, diffusion during sintering must be understood. An investigation into the effects of current on the diffusion of copper and nickel was performed using SPS. Bulk specimens were used to generate diffusion couples in SPS in alternating orientations with respect to the direction of the current. Control samples were produced using a horizontal insertion vacuum furnace. Experiments were performed at temperatures between 850°C and 1000°C for 3 h. Concentration profiles were obtained by the use of both energy-dispersive spectroscopy and a Monte Carlo simulated correction curve. Diffusion coefficients and activation energies were calculated for samples produced by SPS and annealing without current. It was shown that, at temperatures near 0.9 T{sub m}, the application of current in SPS inhibits diffusion between copper and nickel due to the re-orientation of electrons caused by the loss of ferromagnetism in nickel. Activation energy for diffusion is, however, decreased due to the temperature gradients arising from the difference in resistivity between the two species.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of the unstained biological sample by a novel scanning electron generation X-ray microscope based on SEM

We introduced a novel X-ray microscope system based on scanning electron microscopy using thin film, which enables the measurement of unstained biological samples without damage. An unstained yeast sample was adsorbed under a titanium (Ti)-coated silicon nitride (Si{sub 3}N{sub 4}) film 90 nm thick. The X-ray signal from the film was detected by an X-ray photodiode (PD) placed below the sample. With an electron beam at 2.6 kV acceleration and 6.75 nA current, the yeast image is obtained using the X-ray PD. The image is created by soft X-rays from the Ti layer. The Ti layer is effective in generating the characteristic 2.7-nm wavelength X-rays by the irradiation of electrons. Furthermore, we investigated the electron trajectory and the generation of the characteristic X-rays within the Ti-coated Si{sub 3}N{sub 4} film by Monte Carlo simulation. Our system can be easily utilized to observe various unstained biological samples of cells, bacteria, and viruses.

60 APPLIED LIFE SCIENCES↗

A Note on the Effects of Linear Topology Preservation in Monte Carlo Simulations of Knotted Proteins

Monte Carlo simulations are a powerful technique and are widely used in different fields. When applied to complex molecular systems with long chains, such as those in synthetic polymers and proteins, they have the advantage of providing a fast and computationally efficient way to sample equilibrium ensembles and calculate thermodynamic and structural properties under desired conditions. Conformational Monte Carlo techniques employ a move set to perform the transitions in the simulation Markov chain. While accepted conformations must preserve the sequential bonding of the protein chain model and excluded volume among its units, the moves themselves may take the chain across itself. We call this a break in linear topology preservation. In this manuscript, we show, using simple protein models, that there is no difference in equilibrium properties calculated with a move set that preserves linear topology and one that does not. However, for complex structures, such as those of deeply knotted proteins, the preservation of linear topology provides correct equilibrium results but only after long relaxation. In any case, to analyze folding pathways, knotting mechanisms and folding kinetics, the preservation of linear topology may be an unavoidable requirement.

Especial, João N. C. (ORCID:0000000254765370)↗