Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Multimodal Bayesian registration of noisy functions using Hamiltonian Monte Carlo

Functional data registration is a necessary processing step for many applications. The observed data can be inherently noisy, often due to measurement error or natural process uncertainty; which most functional alignment methods cannot handle. A pair of functions can also have multiple optimal alignment solutions, which is not addressed in current literature. In this paper, a flexible Bayesian approach to functional alignment is presented, which appropriately accounts for noise in the data without any pre-smoothing required. Additionally, by running parallel MCMC chains, the method can account for multiple optimal alignments via the multi-modal posterior distribution of the warping functions. To most efficiently sample the warping functions, the approach relies on a modification of the standard Hamiltonian Monte Carlo to be well-defined on the infinite-dimensional Hilbert space. In this work, this flexible Bayesian alignment method is applied to both simulated data and real data sets to show its efficiency in handling noisy functions and successfully accounting for multiple optimal alignments in the posterior; characterizing the uncertainty surrounding the warping functions.

97 MATHEMATICS AND COMPUTING↗

ON THE RADIO AND OPTICAL LUMINOSITY EVOLUTION OF QUASARS

We calculate simultaneously the radio and optical luminosity evolutions of quasars, and the distribution in radio loudness R defined as the ratio of radio and optical luminosities, using a flux-limited data set containing 636 quasars with radio and optical fluxes from White et al. We first note that when dealing with multi-variate data it is imperative to first determine the true correlations among the variables, not those introduced by the observational selection effects, before obtaining the individual distributions of the variables. We use the methods developed by Efron and Petrosian which are designed to obtain unbiased correlations, distributions, and evolution with redshift from a data set truncated due to observational biases. It is found that the population of quasars exhibits strong positive correlation between the radio and optical luminosities. With this correlation, whether intrinsic or observationally induced accounted for, we find that there is a strong luminosity evolution with redshift in both wavebands, with significantly higher radio than optical evolution. We conclude that the luminosity evolution obtained by arbitrarily separating the sources into radio-loud (R > 10) and radio-quiet (R < 10) populations introduces significant biases that skew the result considerably. We also construct the local radio and optical luminosity functions and the density evolution. Finally, we consider the distribution of the radio-loudness parameter R obtained from careful treatment of the selection effects and luminosity evolutions with that obtained from the raw data without such considerations. We find a significant difference between the two distributions and no clear sign of bi-modality in the true distribution for the range of R values considered. Our results indicate therefore, somewhat surprisingly, that there is no critical switch in the efficiency of the production of disk outflows/jets between very radio-quiet and very radio-loud quasars, but rather a smooth transition. Also, this efficiency seems higher for the high-redshift and more luminous sources in the sample considered.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-J-192: Verification of 4D-MRI Internal Target Volume Using Cine MRI

Purpose: To investigate the accuracy of 4D-MRI in determining the Internal Target Volume (ITV) used in radiation oncology treatment planning of liver cancers. Cine MRI is used as the standard baseline in establishing the feasibility and accuracy of 4D-MRI tumor motion within the liver. Methods: IRB approval was obtained for this retrospective study. Analysis was performed on MR images from four patients receiving external beam radiation therapy for liver cancer at our institution. Eligible patients received both Cine and 4D-MRI scans before treatment. Cine images were acquired sagittally in real time at a slice bisecting the tumor, while 4D images were acquired volumetrically. Cine MR DICOM headers were manipulated such that each respiratory frame was assigned a unique slice location. This approach permitted the treatment planning system (Eclipse, Varian Medical Systems) to recognize a complete respiratory cycle as a “volume”, where the gross tumor was contoured temporally. Software was developed to calculate the union of all frame contours in the structure set, resulting in the corresponding plane of the ITV projecting through the middle of the tumor, defined as the Internal Target Area (ITA). This was repeated for 4D-MRI, at the corresponding slice location, allowing a direct comparison of ITAs obtained from each modality. Results: Four patients have been analyzed. ITAs contoured from 4D-MRI correlate with contours from Cine MRI. The mean error of 4D values relative to Cine values is 7.67 +/− 2.55 %. No single ITA contoured from 4D-MRI demonstrated more than 10.5 % error compared to its Cine MRI counterpart. Conclusion: Motion management is a significant aspect of treatment planning within dynamic environments such as the liver, where diaphragmatic and cardiac activity influence plan accuracy. This small pilot study suggests that 4D-MRI based ITA measurements agree with Cine MRI based measurements, an important step towards clinical implementation. NIH 1R21CA165384-01A1.

60 APPLIED LIFE SCIENCES↗

SU-F-J-81: Evaluation of Automated Deformable Registration Between Planning Computed Tomography (CT) and Daily Cone Beam CT Images Over the Course of Prostate Cancer Radiotherapy

Purpose: To compute daily dose delivered during radiotherapy, deformable registration needs to be relatively fast, automated, and accurate. The aim of this study was to evaluate the performance of commercial deformable registration software for deforming between two modalities: planning computed tomography (pCT) images acquired for treatment planning and cone beam (CB) CT images acquired prior to each fraction of prostate cancer radiotherapy. Methods: A workflow was designed using MIM Software™ that aligned and deformed pCT into daily CBCT images in two steps: (1) rigid shifts applied after daily CBCT imaging to align patient anatomy to the pCT and (2) normalized intensity-based deformable registration to account for interfractional anatomical variations. The physician-approved CTV and organ and risk (OAR) contours were deformed from the pCT to daily CBCT over the course of treatment. The same structures were delineated on each daily CBCT by a radiation oncologist. Dice similarity coefficient (DSC) mean and standard deviations were calculated to quantify the deformable registration quality for prostate, bladder, rectum and femoral heads. Results: To date, contour comparisons have been analyzed for 31 daily fractions of 2 of 10 of the cohort. Interim analysis shows that right and left femoral head contours demonstrate the highest agreement (DSC: 0.96±0.02) with physician contours. Additionally, deformed bladder (DSC: 0.81±0.09) and prostate (DSC: 0.80±0.07) have good agreement with physician-defined daily contours. Rectum contours have the highest variations (DSC: 0.66±0.10) between the deformed and physician-defined contours on daily CBCT imaging. Conclusion: For structures with relatively high contrast boundaries on CBCT, the MIM automated deformable registration provided accurate representations of the daily contours during treatment delivery. These findings will permit subsequent investigations to automate daily dose computation from CBCT. However, improved methods need to be investigated to improve deformable results for rectum contours.

60 APPLIED LIFE SCIENCES↗

Fast numerical method for modelling one-dimensional diffraction gratings

Based on the generalised source method, a new method for calculating the light diffraction on one-dimensional dielectric diffraction gratings with an arbitrary profile is proposed. The method is an alternative to the widely used Fourier modal method because it possesses the same possibilities in defining different grating profiles; however, it has a significant advantage in calculating complex-shaped gratings because it requires many fewer mathematical operations. The applicability of the method is shown by comparing the calculation results by this method with the results obtained by the conventional methods of light diffraction calculation on the gratings. (laser applications and other topics in quantum electronics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-dose-rate Intracavitary Radiotherapy in the Management of Cervical Intraepithelial Neoplasia 3 and Carcinoma In Situ Presenting With Poor Histologic Factors After Undergoing Excisional Procedures

Purpose: To assess the effectiveness of high-dose-rate intracavitary radiotherapy (HDR-ICR) in patients with cervical intraepithelial neoplasia 3 (CIN 3) and carcinoma in situ (CIS) presenting with poor histologic factors for predicting residual disease after undergoing diagnostic excisional procedures. Methods and Materials: This study was a retrospective analysis of 166 patients with CIN 3 (n=15) and CIS (n=151) between October 1986 and December 2005. They were diagnosed by conization (n=158) and punch biopsy (n=8). Pathologic analysis showed 135 cases of endocervical gland involvement (81.4%), 74 cases of positive resection margins (44.5%), and 52 cases of malignant cells on endocervical curettage (31.3%). All patients were treated with HDR-ICR using Co{sup 60} or Ir{sup 192} at a cancer center. The dose was prescribed at point A located 2 cm superior to the external os and 2 cm lateral to the axis of the tandem for intact uterus. Results: Median age was 61 years (range, 29-77). The median total dose of HDR-ICR was 30 Gy/6 fractions (range, 30-52). At follow-up (median, 152 months), 2 patients developed recurrent diseases: 1 CIN 2 and 1 invasive carcinoma. One hundred and forty patients survived and 26 patients died, owing to nonmalignant intercurrent disease. Rectal bleeding occurred in one patient; however, this symptom subsided with conservative management. Conclusions: Our data showed HDR-ICR is an effective modality for CIN 3 and CIS patients presenting with poor histologic factors after excisional procedures. HDR-ICR should be considered as a definitive treatment in CIN 3 and CIS patients with possible residual disease after undergoing excisional procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MRI of prostate brachytherapy seeds at high field: A study in phantom

Postimplant evaluation of prostate brachytherapy using magnetic resonance imaging (MRI) at 1.5 T has met with some difficulties due to the uncertainty associated with seed localization despite the excellent anatomical delineation this imaging modality can achieve. Seeds in vascularized regions or outside the prostate, where signal heterogeneity or drop off can obscure their position, can be difficult to identify. The increase in SNR available at 3.0 T offers the potential to improve these issues with visualization. However, before moving directly to in vivo studies, it is important to investigate the effects of artifact size on the ability to localize multiple seeds in close proximity. These artifacts are of extra concern at higher field because of the increased induced field distortions surrounding the seeds. A single prostate brachytherapy seed (IMC6711, OncoSeed) and arrays of seed pairs were suspended in a porcine gel medium and imaged on 1.5 and 3 T MRI scanners for comparison. Two basic acquisition techniques utilized in a wide array of clinical sequences [spin-echo based and gradient-echo (GE) based] were investigated for the types of artifacts they produce, and their dependence on field. Analysis of the resulting voids was performed to determine the relative size of seeds as seen on the images, as well as the ability to distinguish seeds at close proximity. The seed voids at 3 T were only slightly larger than those obtained at 1.5 T (0.5 mm longer and wider) when using a spin-echo type sequence. For this work, the authors used a proton density fast spin-echo (FSE) sequence. These results are promising for the use of 3 T imaging for postimplant evaluation since the SNR will increase by roughly a factor of 2 with only a limited corresponding increase in artifact size. The minimum separation of the seeds to be completely distinguished using void analysis increased from between 1.5 and 3 mm to between 3 and 4.5 mm when going from 1.5 to 3 T FSE imaging. The minimum separation of the seeds for GE at the demonstration TE of 11 ms was found to be between 3 and 4.5 mm for 1.5 T and between 4.5 and 6 mm for 3 T. These GE artifact dimensions will scale down with TE and, as this happens, approach the dimensions of the FSE artifacts given above.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-62: Cardiac Toxicity in Dynamic Conformal Arc Therapy, Intensity-Modulated Radiation Therapy and Volumetric Modulated Arc Therapy of Lung Cancers

Purpose: The cardiac toxicity for lung cancer patients, each treated with dynamic conformal arc therapy (DAT), intensity-modulated radiation therapy (IMRT), or volumetric modulated arc therapy (VMAT) is investigated. Methods: 120 lung patients were selected for this study: 25 treated with DAT, 50 with IMRT and 45 with VMAT. For comparison, all plans were generated in the same treatment planning system, normalized such that the 100% isodose lines encompassed 95% of planning target volume. The plan quality was evaluated in terms of homogeneity index (HI) and 95% conformity index (%95 CI) for target dose coverage and mean dose, maximum dose, V{sub 30} Gy as well as V{sub 5} Gy for cardiac toxicity analysis. Results: When all the plans were analyzed, the VMAT plans offered the best target coverage with 95% CI = 0.992 and HI = 1.23. The DAT plans provided the best heart sparing with mean heart dose = 2.3Gy and maximum dose = 11.6Gy, as compared to 5.7 Gy and 31.1 Gy by IMRT as well as 4.6 Gy and 30.9 Gy by VMAT. The mean V30Gy and V5Gy of the heart in the DAT plans were up to 11.7% lower in comparison to the IMRT and VMAT plans. When the tumor volume was considered, the VMAT plans spared up to 70.9% more doses to the heart when the equivalent diameter of the tumor was larger than 4cm. Yet the maximum dose to the heart was reduced the most in the DAT plans with up to 139.8% less than that of the other two plans. Conclusion: Overall, the VMAT plans achieved the best target coverage among the three treatment modalities, and would spare the heart the most for the larger tumors. The DAT plans appeared advantageous in delivering the least maximum dose to the heart as compared to the IMRT and VMAT plans.

60 APPLIED LIFE SCIENCES↗

Templates for Risk Informed Assurance with Curvature Embeddings (TRACE)

We investigate recovery of geometric structure from networks embedded in manifolds with spatially varying curvature, extending the constant-curvature framework of Lubold et al. (2023). Our work supports cascade risk assessment in critical infrastructure through the Templates for Risk-informed Assurance with Curvature Embeddings (TRACE) framework. Simulations on a bi-modal Gaussian surface show that constant-curvature methods yield weighted averages shaped by clique patterns, while hierarchical clustering identifies distinct regimes. Localized estimation, however, reveals boundary contamination in transitional regions. To address heterogeneity, we develop distance metrics for graphs with edge and node features, proving their metric validity, and validate them via deterministic graph generation from canonical tilings. We further propose a diffusion-based anomaly detection approach that treats networks as glued manifolds, using curvature discontinuities to detect structural anomalies. Employing the carré-du-champ operator and scalar curvature, we achieve robust anomaly discrimination, demonstrated on the Singapore Water Treatment (SWaT) dataset with joint network-traffic and sensor features. Integration with TRACE reveals how curvature shapes cascade dynamics: positive curvature impedes, while negative curvature accelerates propagation. This geometric perspective provides interpretable risk metrics and visualization tools for critical infrastructure managers. While full validation remains ongoing, our contributions establish a rigorous foundation for geometric analysis of network resilience and cascade vulnerability.

97 MATHEMATICS AND COMPUTING↗

Phase Segmentation in Atom-Probe Tomography Using Deep Learning-Based Edge Detection

Abstract Atom-probe tomography (APT) facilitates nano- and atomic-scale characterization and analysis of microstructural features. Specifically, APT is well suited to study the interfacial properties of granular or heterophase systems. Traditionally, the identification of the interface between, for precipitate and matrix phases, in APT data has been obtained either by extracting iso-concentration surfaces based on a user-supplied concentration value or by manually perturbing the concentration value until the iso-concentration surface qualitatively matches the interface. These approaches are subjective, not scalable, and may lead to inconsistencies due to local composition inhomogeneities. We introduce a digital image segmentation approach based on deep neural networks that transfer learned knowledge from natural images to automatically segment the data obtained from APT into different phases. This approach not only provides an efficient way to segment the data and extract interfacial properties but does so without the need for expensive interface labeling for training the segmentation model. We consider here a system with a precipitate phase in a matrix and with three different interface modalities—layered, isolated, and interconnected—that are obtained for different relative geometries of the precipitate phase. We demonstrate the accuracy of our segmentation approach through qualitative visualization of the interfaces, as well as through quantitative comparisons with proximity histograms obtained by using more traditional approaches.

47 OTHER INSTRUMENTATION↗

TH-CD-202-07: A Methodology for Generating Numerical Phantoms for Radiation Therapy Using Geometric Attribute Distribution Models

Purpose: A persistent challenge for the quality assessment of radiation therapy treatments (e.g. contouring accuracy) is the absence of the known, ground truth for patient data. Moreover, assessment results are often patient-dependent. Computer simulation studies utilizing numerical phantoms can be performed for quality assessment with a known ground truth. However, previously reported numerical phantoms do not include the statistical properties of inter-patient variations, as their models are based on only one patient. In addition, these models do not incorporate tumor data. In this study, a methodology was developed for generating numerical phantoms which encapsulate the statistical variations of patients within radiation therapy, including tumors. Methods: Based on previous work in contouring assessment, geometric attribute distribution (GAD) models were employed to model both the deterministic and stochastic properties of individual organs via principle component analysis. Using pre-existing radiation therapy contour data, the GAD models are trained to model the shape and centroid distributions of each organ. Then, organs with different shapes and positions can be generated by assigning statistically sound weights to the GAD model parameters. Organ contour data from 20 retrospective prostate patient cases were manually extracted and utilized to train the GAD models. As a demonstration, computer-simulated CT images of generated numerical phantoms were calculated and assessed subjectively and objectively for realism. Results: A cohort of numerical phantoms of the male human pelvis was generated. CT images were deemed realistic both subjectively and objectively in terms of image noise power spectrum. Conclusion: A methodology has been developed to generate realistic numerical anthropomorphic phantoms using pre-existing radiation therapy data. The GAD models guarantee that generated organs span the statistical distribution of observed radiation therapy patients, according to the training dataset. The methodology enables radiation therapy treatment assessment with multi-modality imaging and a known ground truth, and without patient-dependent bias.

60 APPLIED LIFE SCIENCES↗

Cardiovascular Morbidity After Radiotherapy or Chemoradiation in Patients With Cervical Cancer

Purpose: To evaluate the risk of cardiovascular events (CVE) in patients with cervical cancer treated with radiotherapy or chemoradiation. Methods and Materials: The incidence of CVE in patients treated between 1989 and 2002 by radiotherapy or chemoradiation was compared with a Dutch reference population. Standardized incidence ratios (SIRs) were calculated for myocardial infarction (MI), angina pectoris (AP), congestive heart failure (CHF), cerebrovascular accident (CVA) separately and for any cardiac event combined (MI, AP, and CHF). Results: In 277 patients with a median follow-up of 4.5 years (range, 0.1-17 years) and a median survival of 9.2 years, 27 cardiac events occurred. The 5-, 10-, and 15-year actuarial incidence of any cardiac event were 9, 14, and 16%, respectively. For the whole population, the SIR for MI was elevated (2.05, 95% CI: 1.12-3.43). The radiotherapy group (n = 132) was older and had more cardiovascular risk factors than the chemoradiation group (n = 145). The SIR for MI in the radiotherapy group was 2.88 (95% CI: 1.44-5.15) and in the chemoradiation group 1.00 (95% CI: 0.21-7.47). In multivariate analyses, there was no relation between treatment modality and the risk for MI. Conclusions: In this cohort of cervical cancer patients, an increased risk for developing a MI was observed. This increased risk of MI, in combination with the high prevalence of cardiovascular risk factors in cervical cancer patients, urges the need to explore strategies to reduce their risk for cardiovascular morbidity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Collaboration as a second thought.

Collaboration is often an afterthought to a project or development. In this paper we describe and analyze our experiences in developing collaborative technologies, most often involving the sharing of visual information. We have often developed these in a context that required us to retrofit existing analysis applications with collaboration capabilities. This approach, though fruitful, is time-consuming, expensive, and often difficult to re-apply elsewhere - it is just hard to change an existing application. One way to make such an effort easier is to package the collaborative components as a kit that can be leveraged on a case-by-case basis. The fixed interface provided by a well-designed toolkit eases the integration process by providing an unchanging and familiar set of components to deploy. Better still, we find, are approaches that require no modification of applications while providing rich and powerful means for sharing information with collaborators. We discuss three separate and illuminating examples that meet this criterion in different ways: (1) building the collaborative potential into the underlying abstractions on which operating systems are built, (2) building tools that live side-by-side with any application in the context provided by the operating system, or by (3) building information tools that use collaborative modalities to better integrate with our workflow. These are probably not the only options, but they all derive from an approach where collaboration is considered early in the design process and therefore manifests itself deep in the computing infrastructure giving it a wider cast.

97 MATHEMATICS AND COMPUTING↗

TU-A-210-00: HIFU Therapies - A Primer

High-intensity focused ultrasound (HIFU) has developed rapidly in recent years and is used frequently for clinical treatments in Asia and Europe with increasing clinical use and clinical trial activity in the US, making it an important medical technology with which the medical physics community must become familiar. Akin to medical devices that deliver treatments using ionizing radiation, HIFU relies on emitter geometry to non-invasively form a tight focus that can be used to affect diseased tissue while leaving healthy tissue intact. HIFU is unique in that it does not involve the use of ionizing radiation, it causes thermal necrosis in 100% of the treated tissue volume, and it has an immediate treatment effect. However, because it is an application of ultrasound energy, HIFU interacts strongly with tissue interfaces, which makes treatment planning challenging. In order to appreciate the advantages and disadvantages of HIFU as a thermal therapy, it is important to understand the underlying physics of ultrasound tissue interactions. The first lecture in the session will provide an overview of the physics of ultrasound wave propagation; the mechanism for the accumulation of heat in soft-tissue; image-guidance modalities including temperature monitoring; current clinical applications and commercial devices; active clinical trials; alternate mechanisms of action (future of FUS). The second part of the session will compare HIFU to existing ionization radiation techniques. The difficulties in defining a clear concept of absorbed dose for HIFU will be discussed. Some of the technical challenges that HIFU faces will be described, with an emphasis on how the experience of radiation oncology physicists could benefit the field. Learning Objectives: Describe the basic physics and biology of HIFU, including treatment delivery and image guidance techniques. Summarize existing and emerging clinical applications and manufacturers for HIFU. Understand that thermal ablation with HIFU is likely the first of several applications of the technology Learn about some similarities and differences between HIFU and ionizing radiation in terms of physics and biological effects. Learn about some of the technical challenges HIFU faces that might benefit from the experience of radiation oncology physicists including treatment planning improvements, quality assurance procedures, and treatment risk analysis. David Schlesinger receives research support from Elekta Instruments, AB. Matt Eames is an employee of the Focused Ultrasound Foundation which supports research and clinical trials. Dr. Eames conducts research which is supported by the Focused Ultrasound Foundation.

60 APPLIED LIFE SCIENCES↗

TU-A-210-01: HIFU Physics and Delivery

High-intensity focused ultrasound (HIFU) has developed rapidly in recent years and is used frequently for clinical treatments in Asia and Europe with increasing clinical use and clinical trial activity in the US, making it an important medical technology with which the medical physics community must become familiar. Akin to medical devices that deliver treatments using ionizing radiation, HIFU relies on emitter geometry to non-invasively form a tight focus that can be used to affect diseased tissue while leaving healthy tissue intact. HIFU is unique in that it does not involve the use of ionizing radiation, it causes thermal necrosis in 100% of the treated tissue volume, and it has an immediate treatment effect. However, because it is an application of ultrasound energy, HIFU interacts strongly with tissue interfaces, which makes treatment planning challenging. In order to appreciate the advantages and disadvantages of HIFU as a thermal therapy, it is important to understand the underlying physics of ultrasound tissue interactions. The first lecture in the session will provide an overview of the physics of ultrasound wave propagation; the mechanism for the accumulation of heat in soft-tissue; image-guidance modalities including temperature monitoring; current clinical applications and commercial devices; active clinical trials; alternate mechanisms of action (future of FUS). The second part of the session will compare HIFU to existing ionization radiation techniques. The difficulties in defining a clear concept of absorbed dose for HIFU will be discussed. Some of the technical challenges that HIFU faces will be described, with an emphasis on how the experience of radiation oncology physicists could benefit the field. Learning Objectives: Describe the basic physics and biology of HIFU, including treatment delivery and image guidance techniques. Summarize existing and emerging clinical applications and manufacturers for HIFU. Understand that thermal ablation with HIFU is likely the first of several applications of the technology Learn about some similarities and differences between HIFU and ionizing radiation in terms of physics and biological effects. Learn about some of the technical challenges HIFU faces that might benefit from the experience of radiation oncology physicists including treatment planning improvements, quality assurance procedures, and treatment risk analysis. David Schlesinger receives research support from Elekta Instruments, AB. Matt Eames is an employee of the Focused Ultrasound Foundation which supports research and clinical trials. Dr. Eames conducts research which is supported by the Focused Ultrasound Foundation.

60 APPLIED LIFE SCIENCES↗

TU-A-210-02: HIFU: Why Should a Radiation Oncology Physicist Pay Attention?

High-intensity focused ultrasound (HIFU) has developed rapidly in recent years and is used frequently for clinical treatments in Asia and Europe with increasing clinical use and clinical trial activity in the US, making it an important medical technology with which the medical physics community must become familiar. Akin to medical devices that deliver treatments using ionizing radiation, HIFU relies on emitter geometry to non-invasively form a tight focus that can be used to affect diseased tissue while leaving healthy tissue intact. HIFU is unique in that it does not involve the use of ionizing radiation, it causes thermal necrosis in 100% of the treated tissue volume, and it has an immediate treatment effect. However, because it is an application of ultrasound energy, HIFU interacts strongly with tissue interfaces, which makes treatment planning challenging. In order to appreciate the advantages and disadvantages of HIFU as a thermal therapy, it is important to understand the underlying physics of ultrasound tissue interactions. The first lecture in the session will provide an overview of the physics of ultrasound wave propagation; the mechanism for the accumulation of heat in soft-tissue; image-guidance modalities including temperature monitoring; current clinical applications and commercial devices; active clinical trials; alternate mechanisms of action (future of FUS). The second part of the session will compare HIFU to existing ionization radiation techniques. The difficulties in defining a clear concept of absorbed dose for HIFU will be discussed. Some of the technical challenges that HIFU faces will be described, with an emphasis on how the experience of radiation oncology physicists could benefit the field. Learning Objectives: Describe the basic physics and biology of HIFU, including treatment delivery and image guidance techniques. Summarize existing and emerging clinical applications and manufacturers for HIFU. Understand that thermal ablation with HIFU is likely the first of several applications of the technology Learn about some similarities and differences between HIFU and ionizing radiation in terms of physics and biological effects. Learn about some of the technical challenges HIFU faces that might benefit from the experience of radiation oncology physicists including treatment planning improvements, quality assurance procedures, and treatment risk analysis. David Schlesinger receives research support from Elekta Instruments, AB. Matt Eames is an employee of the Focused Ultrasound Foundation which supports research and clinical trials. Dr. Eames conducts research which is supported by the Focused Ultrasound Foundation.

60 APPLIED LIFE SCIENCES↗

The Effect of Intensity-Modulated Radiotherapy on Radiation-Induced Second Malignancies

Purpose: To compare intensity-modulated radiotherapy (IMRT) with three-dimensional conformal radiotherapy (3D-CRT) in terms of carcinogenic risk for actual clinical scenarios. Method and Materials: Clinically equivalent IMRT plans were generated for prostate, breast, and head-and-neck cases treated with 3D-CRT. Two possible dose-response models for radiocarcinogenesis were generated based on A-bomb survivor data corrected for fractionation. Dose-volume histogram analysis was used to determine dose and its distribution to nontargeted tissues within the planning CT scan volume and thermoluminescent dosimetry for the rest of the body. Carcinogenic estimates were calculated with and without a correction factor accounting for cancer patients' advanced age and reduced longevity. Results: For the model assuming a plateau in risk above 2-Gy single-fraction-equivalent (SFE), IMRT and 3D-CRT produced risks of 1.7% and 2.1%, respectively, for prostate; 1.9% and 1.8%, respectively, for nasopharynx; 1% each for tonsil; and 1.4-2.2% and 1.5-1.6%, respectively, depending on technique, for breast. Assuming a reduction in risk above 2-Gy SFE, risks for IMRT and 3D-CRT were 1.1% and 1.5%, respectively, for prostate; 1.4% and 1.2%, respectively, for nasopharynx; 1% each for tonsil; and 1.3-1.8% vs. 1.3-1.6%, respectively, for breast. Applying a correction factor of 0.5 for cancer patients halved these risks and their relative differences. Conclusions: Carcinogenic risks were comparable in absolute terms between modalities. Risks are dependant on technique used. Risks with IMRT are influenced by monitor unit demand and are therefore software/hardware dependant. The dose-response model accounting for cell killing at higher doses fitted best with actual observed risks.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low-dose-rate Brachytherapy for Prostate Cancer in Low-resource Settings

Purpose: In areas with limited health care, it is important to identify and implement effective treatment methods and to optimize available resources. We investigated the implementation of a low-dose-rate (LDR) brachytherapy program for the treatment of prostate cancer (PCa) in a low-resource setting such as Puerto Rico (PR), where PCa is the main cause of cancer-associated death. Methods and Materials: After institutional approval, the medical records of patients with nonmetastatic PCa undergoing LDR brachytherapy from 2008 to 2013 were reviewed from PR. The factors analyzed included adequate D{sub 90} (radiation dose delivered to 90% of the target volume) coverage (≥140 Gy), early and late toxicity (Common Terminology Criteria for Adverse Events grade >2), and prostate-specific antigen failure. Freedom from biochemical failure was evaluated using Kaplan-Meier analysis. Results: The barriers to implementation of LDR brachytherapy in a country with limited resources were identified. These included lack of access to funding for startup costs, specific referral patterns, lack of trained support staff, such as dosimetrists and physicists, and initial opposition from insurance companies for reimbursement. The initial results from 191 patients were included in the present study with a median follow-up period of 26 months. Prostate-specific antigen failure occurred in 6 patients (3%). No early or late gastrointestinal toxicity (grade >2) developed. Only 3 (2%) and 2 (1%) patients experienced early and late genitourinary toxicity (grade >2), respectively. The 2- and 3-year freedom from biochemical failure in this population was 97% and 95.9%, respectively. Conclusions: At present, limited data are available delineating the barriers faced by low-resource settings in the implementation of LDR brachytherapy. Our data highlight the issues unique to this environment and support the use of LDR brachytherapy as a reliable and effective treatment modality for patients with PCa in low-resource settings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗