Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscope and microscopy.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Measurement of Temperature Fluctuations and Microscopic Growth Rates in a Silicon Floating Zone Under Microgravity

USA Several microgravity experiments on sounding rockets and the Space Shuttle have shown that time-dependent thermocapillary (Marangoni) convection is the major cause for the formation of dopant striations in floating-zone grown semiconductor crystals, at least in small-scale systems not employing RF heating. To quantify this correlation, a silicon floating-zone experiment was performed during the TEXUS36 flight (February 7, 1998) in the monoellipsoid mirror furnace TEM02-ELLI. During the experiment, temperature fluctuations in the silicon melt zone and the microscopic growth rate were simultaneously measured. Temperature fluctuations of 0.5 C - 0.7 C with main frequencies between 0.1 Hz and 0.3 Hz were detectable. The microscopic growth rate fluctuated considerably around the average growth rate of 1 mm/min: rates from 4 mm/min to negative values (backmelting) were observed. Dopant striations are clearly visible in the Sb-doped crystal. They were characterized by Spreading Resistance measurements and Differential Interference Contrast microscopy. The frequencies associated with the dopant inhomogeneities correspond quite well with those of the temperature fluctuations and microscopic growth rates. 3D numerical simulations were performed to predict the optimum position of the temperature sensor, to evaluate characteristic temperature amplitudes and frequencies, and to give insight into the instability mechanisms of Marangoni convection in this configuration. The simulations were in good agreement with the experimental values, showing temperature fluctuations with frequencies ? 0.25 Hz and amplitudes up to 1.8 C at a position equivalent to that of the sensor tip in the experiment.

Croell, Arne↗

Calibration of lateral force measurements in atomic force microscopy with a piezoresistive force sensor

We present here a method to calibrate the lateral force in the atomic force microscope. This method makes use of an accurately calibrated force sensor composed of a tipless piezoresistive cantilever and corresponding signal amplifying and processing electronics. Two ways of force loading with different loading points were compared by scanning the top and side edges of the piezoresistive cantilever. Conversion factors between the lateral force and photodiode signal using three types of atomic force microscope cantilevers with rectangular geometries (normal spring constants from 0.092 to 1.24 N/m and lateral stiffness from 10.34 to 101.06 N/m) were measured in experiments using the proposed method. When used properly, this method calibrates the conversion factors that are accurate to {+-}12.4% or better. This standard has less error than the commonly used method based on the cantilever's beam mechanics. Methods such of this allow accurate and direct conversion between lateral forces and photodiode signals without any knowledge of the cantilevers and the laser measuring system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atomic force microscopy deep trench and sidewall imaging with an optical fiber probe

We report a method to measure critical dimensions of micro- and nanostructures using the atomic force microscope (AFM) with an optical fiber probe (OFP). This method is capable of scanning narrow and deep trenches due to the long and thin OFP tip, as well as imaging of steep sidewalls with unique profiling possibilities by laterally tilting the OFP without any modifications of the optical lever. A switch control scheme is developed to measure the sidewall angle by flexibly transferring feedback control between the Z- and Y-axis, for a serial scan of the horizontal surface (raster scan on XY-plane) and sidewall (raster scan on the YZ-plane), respectively. In experiments, a deep trench with tapered walls (243.5 μm deep) and a microhole (about 14.9 μm deep) have been imaged with the orthogonally aligned OFP, as well as a silicon sidewall (fabricated by deep reactive ion etching) has been characterized with the tilted OFP. Moreover, the sidewall angle of TGZ3 (AFM calibration grating) was accurately measured using the switchable scan method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation of Materials Processes in Liquids in the Electron Microscope

Materials synthesis and the functioning of devices often indispensably involve liquid media. But direct visualization of dynamic process in liquids, especially with high spatial and temporal resolution, has been challenging. For solid materials, advances in aberration corrected electron microscopy have made observation of atomic level features a routine practice. Here we discuss the extent to which one can take advantage of the resolution of modern electron microscopes to image phenomenon occuring in liquids. We will describe the fundamentals of two different experimental approaches, closed and open liquid cells. We will illustrate the capabilities of each approach by considering processes in batteries and nucleation and growth of nanoparticles from solution. We conclude that liquid cell electron microscopy appears to be duly fulfilling its role for in situ studies of nanoscale processes in liquids, revealing physical and chemical processes otherwise difficult to observe.

Environmental Molecular Sciences Laboratory↗

Reversible patterning of poly(methylmethacrylate) doped with disperse Red 1 by laser scanning

Thin poly(methylmethacrylate) films doped by or covalently attached to disperse Red 1 acrylate (DR1) were patterned by laser scanning and simultaneous sample movement in confocal microscope. In both cases, periodical structure due to Marangoni effect is created. Modified polymers surfaces were analyzed by FTIR spectroscopy, X-ray photoelectron spectroscopy, and atomic force microscopy. After first stage of patterning, second stage with sample movement in perpendicular direction was applied. Depending on the method of DR1 dotation fishnet structure is obtained or pattern structure disappears. In the latter case, reversibility of pattern formation and erasure by laser scanning was studied.

36 MATERIALS SCIENCE↗

A single-cell scraper based on an atomic force microscope for detaching a living cell from a substrate

We describe an atomic force microscope (AFM) manipulator that can detach a single, living adhesion cell from its substrate without compromising the cell's viability. The micrometer-scale cell scraper designed for this purpose was fabricated from an AFM micro cantilever using focused ion beam milling. The homemade AFM equipped with the scraper was compact and standalone and could be mounted on a sample stage of an inverted optical microscope. It was possible to move the scraper using selectable modes of operation, either a manual mode with a haptic device or a computer-controlled mode. The viability of the scraped single cells was evaluated using a fluorescence dye of calcein-acetoxymethl ester. Single cells detached from the substrate were collected by aspiration into a micropipette capillary glass using an electro-osmotic pump. As a demonstration, single HeLa cells were selectively detached from the substrate and collected by the micropipette. It was possible to recultivate HeLa cells from the single cells collected using the system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electron Microscopic Examination of an Irradiated TRISO Coated Particle of AGR-2 Experiment: AGR2-222-RS019

The transmission electron microscopic (TEM) examination of an irradiated tristructural isotropic (TRISO) coated particle from advanced gas reactor (AGR) 2 fuel Compact 2-2-2 is presented in this report. Compact 2-2-2 refers to the compact in Capsule 2 at Level 2 of Stack 2. The examination on AGR2 222 RS019 is focused on the interface between the silicon carbide (SiC) to inner pyrolytic carbon (IPyC) layer, central part of SiC, and the interface between SiC and outer pyrolytic carbon layer. The SiC grain boundary distribution and associated fission product precipitates were characterized by scanning transmission electron microscopy (STEM) energy dispersive spectroscopy (EDS), and precession electron diffraction (PED) in the transmission electron microscope. Two separate locations on SiC layer were selected for on the basis of the intact of the buffer layer in the irradiated TRISO particle. The key observation in this particle is that the compositional nature of grain boundary precipitates is more complex near IPyC/SiC layer where Pd, Pd-Ag, Pd-U containing precipitates can be observed. However, the compositions of precipitate towards outer most region of SiC mainly contain Pd. Ag has been observed in the IPyC/SiC layer in one of the two locations. Comparison of the results to previously irradiated and analyzed, Variant 3, safety tested AGR-1 TRISO particles (AGR1-433-001 and AGR1 222-RS004) showed the grain boundary distributions have some noticeable differences. The differences in coincident site lattice grain boundary and misorientation angles are possibly inherent to the fabrication process. Neutron irradiation induced void distribution has been found to be nonuniform. A high concentration of smaller voids is found at stacking faults compared to those in the SiC matrix. Larger void sizes are observed in the SiC location that is near to the broken buffer layer. This void size variation with integrity of buffer layer can potentially affect the fission product retention. However, the average void size continuously decreases along the radius of SiC in both locations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Microstructure of RERTR DU-Alloys Irradiated with Krypton Ions

Fuel development for reduced enrichment research and test reactor (RERTR) program is tasked with the development of new low enrichment uranium fuels that can be employed to replace existing high enrichment uranium fuels currently used in many research and test reactors worldwide. Radiation stability of the interaction product formed at fuel-matrix interface has a strong impact on fuel performance. Three depleted uranium alloys are cast that consist of the following 5 phases of interest to be investigated: U(Si,Al)3, (U,Mo)(Si,Al)3, UMo2Al20, U6Mo4Al43 and UAl4. Irradiation of TEM disc samples with 500 keV Kr ions at 200?C to high doses up to ~100 dpa were conducted using an intermediate voltage electron microscope equipped with an ion accelerator. The irradiated microstructure of the 5 phases is characterized using transmission electron microscopy. The results will be presented and the implication of the observed irradiated microstructure on the fuel performance will be discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Rotational positioning system adapted to atomic force microscope for measuring anisotropic surface properties

The diverse atomic configurations induce the anisotropic surface properties. For investigating anisotropic phenomena, we developed a rotational positioning system adapted to atomic force microscope (AFM). This rotational positioning system is applied to revolve the measured sample to defined angular direction, and it composed of an inertial rotational stepper and a visual angular measurement. The inertial rotational stepper with diameter 30 mm and height 7.6 mm can be easily attached to the AFM-system built in any general optical microscope. Based on a clearance less bearing and the inertial driving method, its bidirectional angular resolution reaches 0.005 deg. per step. For realizing a close-loop controlled angular positioning function, the visual measurement method is utilized. Through the feedback control, the angular positioning error is less than 0.01 deg. For verifying the system performance, we used it to investigate the anisotropic surface properties of graphite. Through a modified cantilever tip, the atomic-scale stick-slip, and the anisotropic friction phenomena can be distinctly detected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Oxidation characteristics of gasoline direct-injection (GDI) engine soot: Catalytic effects of ash and modified kinetic correlation

In this paper, experimental analyses are conducted into the GDI soot oxidation characteristics as dependent on engine operating conditions. Soot is sampled at various engine operating conditions of a commercial 2.4 L GDI engine with a naturally aspirated, homogeneous, and stoichiometric operation strategy. The oxidation reactivity, ash composition, and carbon nanostructure of the GDI soot samples are analyzed using thermogravimetric analysis (TGA), scanning electron microscope–energy-dispersive spectroscopy (SEM-EDS), high-resolution transmission electron microscopy (HR-TEM), and Raman spectroscopy. Based on the analyses, a global GDI soot oxidation mechanism is proposed which includes the effects of soluble organic fractions (SOF)/weakly bonded carbon (WBC), and three types of ash on GDI soot oxidation. The results show that GDI soot contains an order of magnitude higher ash fraction than does conventional diesel soot, and oxidation reactivity is significantly enhanced by the catalytic effects of ash, as a function of ash content in soot. A modified empirical kinetic correlation for GDI soot oxidation is suggested on the basis of the results, and the modified kinetic correlation predicts the GDI soot oxidation rate accurately for various engine operation points at wide ranges of soot conversion and temperature without modifying kinetic parameters. The kinetic parameters are determined from isothermal and non-isothermal thremogravimetric analysis (TGA) soot oxidation tests; the methods are elucidated in detail.

33 ADVANCED PROPULSION SYSTEMS↗

Effect of processing parameters on the formation of C{sub f}/LAS composites/Ag−Cu−Ti/TC4 brazed joint

C{sub f}/LAS composites were successfully jointed to TC4 alloy with Ag−Cu−Ti filler by vacuum brazing. The interfacial microstructure of TC4/C{sub f}/LAS composites joints was characterized by employing scanning electron microscope (SEM), energy dispersive spectrometer (EDS), X-diffraction (XRD) and transmission electron microscopy (TEM). The determination of the thin interfacial reaction layer (TiSi{sub 2} + TiC layer) was realized by TEM. The effect of holding time on the interfacial microstructure and shear strength were investigated. With the increasing holding time, the thickness of diffusion layer, Ti{sub 3}Cu{sub 4} layer, and TiSi{sub 2} + TiC layer increased obviously, on the contrary, that of Ti−Cu intermetallic compound layers decreased gradually. Besides, blocky Ti{sub 3}Cu{sub 4} phase was coarsened when the joint was brazed at 890 °C for 20 min, which deteriorated the mechanical properties of the joint dramatically. The interfacial evolution of TC4/C{sub f}/LAS composites joint and the formation of TiSi{sub 2}, TiC, Ti{sub 3}Cu{sub 4}, TiCu and Ti{sub 2}Cu phases were expounded. The maximum shear strength of 26.4 MPa was obtained when brazed at 890 °C for 10 min. - Highlights: •The thin interface reaction layer was determined to be TiSi{sub 2} + TiC layer by TEM. •Holding time had influence on the interfacial microstructure and joint properties. •Microstructural evolution mechanism and reactions of brazed joints were expounded.

36 MATERIALS SCIENCE↗

Entangled Photon Spectroscopy

Conspectus The enhanced interest in quantum-related phenomena has provided new opportunities for chemists to push the limits of detection and analysis of chemical processes. As some have called this the second quantum revolution, a time has come to apply the rules learned from previous research in quantum phenomena toward new methods and technologies important to chemists. While there has been great interest recently in quantum information science (QIS), the quest to understand how nonclassical states of light interact with matter has been ongoing for more than two decades. Our entry into this field started around this time with the use of materials to produce nonclassical states of light. Here, the process of multiphoton absorption led to photon-number squeezed states of light, where the photon statistics are sub-Poissonian. In addition to the great interest in generating squeezed states of light, there was also interest in the formation of entangled states of light. While much of the effort is still in foundational physics, there are numerous new avenues as to how quantum entanglement can be applied to spectroscopy, imaging, and sensing. These opportunities could have a large impact on the chemical community for a broad spectrum of applications. Here, we discuss the use of entangled (or quantum) light for spectroscopy as well as applications in microscopy and interferometry. The potential benefits of the use of quantum light are discussed in detail. From the first experiments in porphyrin dendrimer systems by Dr. Dong-Ik Lee in our group to the measurements of the entangled two photon absorption cross sections of biological systems such as flavoproteins, the usefulness of entangled light for spectroscopy has been illustrated. These early measurements led the way to more advanced measurements of the unique characteristics of both entangled light and the entangled photon absorption cross-section, which provides new control knobs for manipulating excited states in molecules. The first reports of fluorescence-induced entangled processes were in organic chromophores where the entangled photon cross-section was measured. These results would later have widespread impact in applications such as entangled two-photon microscopy. From our design, construction and implementation of a quantum entangled photon excited microscope, important imaging capabilities were achieved at an unprecedented low excitation intensity of 10 7 photons/s, which is 6 orders of magnitude lower than the excitation level for the classical two-photon image. New reports have also illustrated an advantage of nonclassical light in Raman imaging as well. From a standpoint of more precise measurements, the use of entangled photons in quantum interferometry may offer new opportunities for chemistry research. Experiments that combine molecular spectroscopy and quantum interferometry, by utilizing the correlations of entangled photons in a Hong–Ou–Mandel (HOM) interferometer, have been carried out. The initial experiment showed that the HOM signal is sensitive to the presence of a resonant organic sample placed in one arm of the interferometer. In addition, parameters such as the dephasing time have been obtained with the opportunity for even more advanced phenomenology in the future.

36 MATERIALS SCIENCE↗

Multiscale Mechanical Characterization of Mineral-Reinforced Wood Cell Walls

Studying the multiscale mechanics of bio-based composites offers unique perspectives on underlying structure–property relations. Cellular materials, such as wood, are highly organized, hierarchical assemblies of load-bearing structural elements that respond to mechanical stimuli at the microscopic, mesoscopic and macroscopic scale. In this study, we modified oak wood with nanocrystalline ferrihydrite, a widespread ferric oxyhydroxide mineral, and characterized the resulting mechanical properties of the composite at various levels of organization. Ferrihydrite nanoparticles were deposited inside the wood cell wall by an in situ chemical reaction, resulting in increased stiffness and hardness of the functionalized secondary cell wall, as evidenced by region-specific nanoindentation tests under an electron microscope. Chemically modified and pristine wood samples were characterized by using atomic force microscopy in the bimodal frequency modulation mode, which produced topographical images from the cellular ultrastructure with high lateral resolution and localized nanomechanical information across distinct cell wall layers. In conclusion, despite mineral reinforcement at the cell wall level, the macroscopic fracture behavior examined through three-point flexural testing remained unchanged upon modification, as cell–cell adhesion could be impaired by harsh chemical conditions.

Cells↗

Visualization of Aluminum Ions at the Mica Water Interface Links Hydrolysis State-to-Surface Potential and Particle Adhesion

When hydrolyzable cations such as aluminum interact with solid-water interfaces, macroscopic interfacial properties (e.g., surface charge and potential) and interfacial phenomena (e.g., particle adhesion) become tightly linked with the microscopic details of ion adsorption and speciation. We use in situ atomic force microscopy to directly image individual aluminum ions at a mica-water interface and show how adsorbate populations change with pH and aluminum activity. Complementary streaming potential measurements then allow us to build a triple layer model (TLM) that links surface potentials to adsorbate populations, via equilibrium binding constants. Our model predicts that hydrolyzed species dominate the mica-water interface, even when unhydrolyzed species dominate the solution. Ab initio molecular dynamics (AIMD) simulations confirm that aluminum hydrolysis is strongly promoted at the interface. The TLM indicates that hydrolyzed adsorbates are responsible for surface-potential inversions, and we find strong correlations between hydrolyzed adsorbates and particle-adhesion forces, suggesting that these species mediate adhesion by chemical bridging.

Legg, Benjamin A.↗

Real-time studies of ferroelectric domain switching: a review

Ferroelectric materials have been utilized in a broad range of electronic, optical, and electromechanical applications and hold the promise for the design of future high-density nonvolatile memories and multifunctional nano-devices. The applications of ferroelectric materials stem from the ability to switch polarized domains by applying an electric field, and therefore a fundamental understanding of the switching dynamics is critical for design of practical devices. In this review, we summarize the progress in the study of the microscopic process of ferroelectric domain switching using recently developed in situ transmission electron microscopy (TEM). We first briefly introduce the instrumentation, experimental procedures, imaging mechanisms, and analytical methods of the state-of-the-art in situ TEM techniques. The application of these techniques to studying a wide range of complex switching phenomena, including domain nucleation, domain wall motion, domain relaxation, domain-defect interaction, and the interplay between different types of domains, is demonstrated. The underlying physics of these dynamic processes are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enabling direct nanoscale observations of biological reactions with dynamic TEM

Biological processes can occur over a wide range of spatial and temporal scales; from femtoseconds to hours and from angstroms to meters. Although no single experimental method can fully cover this entire phase space, many new biological insights can be expected from a better understanding of the processes that occur on the very fast timescales and very small length scales. In this regard, new instruments that use fast x-ray or electron pulses are now available that are expected to reveal new mechanistic insights for macromolecular protein dynamics. To ensure that any observed conformational change is physiologically relevant and not constrained by three-dimensional crystal packing, it would be preferable for experiments to utilize smaller protein samples such as single particles or two-dimensional crystals that mimic the target protein’s native environment. These samples aren’t typically amenable to x-ray analysis, but transmission electron microscopy has successfully imaged such sample geometries for over 40 years and permits data acquisition using both direct imaging and diffraction modes. While conventional transmission electron microscopes (TEM) have only visualized biological samples with atomic resolution in an arrested or frozen state, the recent development of the dynamic TEM (DTEM) extends electron microscopy capabilities into dynamics. A new 2nd generation DTEM that is currently being constructed has the potential to observe live biological processes with unprecedented spatiotemporal resolution by using pulsed electron packets to probe the sample on the micro- and nanosecond timescale. In addition to the enhanced temporal resolution, the DTEM also operates in the pump-probe regime that can permit visualizing reactions propagating in real-time. This article reviews the experimental parameters necessary for coupling DTEM with in situ liquid microscopy to allow direct imaging of protein conformational dynamics in a fully hydrated environment.

Dynamic TEM↗

Electron Microscopy Laboratory MST-6: Instruments and Capabilities [Slides]

The Electron Microscopy Laboratory (EML) is a lab-wide facility, overseen by MST-6, that is available for use by qualified users. In FY12 the EML service contract costs were covered by funds from LDRD, BES, NE and other programs. Users can be trained to use the equipment independently or work collaboratively with other trained users or EML staff. Users are charged for the labor portion of their training. Most electron microscopy is done by staff or post-docs but some students are performing microscopy, particularly SEM. In the Materials Science Complex (MSC), there are two optical microscopes, two scanning electron microscopes (SEM’s), a SEM/ FIB (a SEM with a focused ion beam (FIB) column added), three transmission electron microscopes (TEM’s) and sample preparation equipment.

36 MATERIALS SCIENCE↗

Fluorescence Microscopy Denoising (FMD) dataset

We created a dataset - the Fluorescence Microscopy Denoising (FMD) dataset - that is dedicated to Poisson-Gaussian denoising. The dataset consists of 12,000 real fluorescence microscopy images obtained with commercial confocal, two-photon, and wide-field microscopes and representative biological samples such as BPAE cells, zebrafish, and mouse brain tissues. We use image averaging to effectively obtain ground truth images and 60,000 noisy images with different noise levels.

Image Denoising↗