Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement Science Laboratory”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Development and Implementation of 3-D, High Speed Capacitance Tomography for Imaging Large-Scale, Cold-Flow Circulating Fluidized Bed

A detailed understanding of multiphase flow behavior inside a Circulating Fluidized Bed (CFB) requires a 3-D technique capable of visualizing the flow field in real-time. Electrical Capacitance Volume Tomography (ECVT) is a newly developed technique that can provide such measurements. The attractiveness of the technique is in its low profile sensors, fast imaging speed and scalability to different section sizes, low operating cost, and safety. Moreover, the flexibility of ECVT sensors enable them to be designed around virtually any geometry, rendering them suitable to be used for measurement of solid flows in exit regions of the CFB. Tech4Imaging LLC has worked under contract with the U.S. Department of Energy's National Energy Technology Laboratory (DOE NETL) to develop an ECVT system for cold flow visualization and install it on a 12 inch ID circulating fluidized bed. The objective of this project was to help advance multi-phase flow science through implementation of an ECVT system on a cold flow model at DOE NETL. This project has responded to multi-phase community and industry needs of developing a tool that can be used to develop flow models, validate computational fluid dynamics simulations, provide detailed real-time feedback of process variables, and provide a comprehensive understating of multi-phase flow behavior. In this project, a complete ECVT system was successfully developed after considering different potential electronics and sensor designs. The system was tested at various flow conditions and with different materials, yielding real-time images of flow interaction in a gas-solid flow system. The system was installed on a 12 inch ID CFB of the US Department of Energy, Morgantown Labs. Technical and economic assessment of Scale-up and Commercialization of ECVT was also conducted. Experiments conducted with larger sensors in conditions similar to industrial settings are very promising. ECVT has also the potential to be developed for imaging multi-phase flow systems in high temperature and high pressure conditions, typical in many industrial applications.

42 ENGINEERING↗

Los Alamos National Laboratory RD 2015 Profile

A vital, multidisciplinary national security science laboratory, Los Alamos National Laboratory applies science and technology to help solve the nation’s toughest challenges. Outstanding science is the foundation for the past, present, and future. A rich variety of research programs directly and indirectly support the Laboratory’s basic mission: to ensure the safety, security, and reliability of the nation’s nuclear deterrent; reduce global threats; and solve emerging national security energy challenges. The Laboratory also works on nuclear nonproliferation and border security, energy and infrastructure security, and measures to counter nuclear and biological terrorist threats.

99 GENERAL AND MISCELLANEOUS↗

Chromatographic, Spectroscopic and Mass Spectrometric Approaches for Exploring the Habitability of Mars in 2012 and Beyond with the Curiosity Rover

The Sample Analysis at Mars (SAM) suite of instruments on the Curiosity Rover of Mars Science Laboratory Mission is designed to provide chemical and isotopic analysis of organic and inorganic volatiles for both atmospheric and solid samples. The goals of the science investigation enabled by the gas chromatograph mass spectrometer and tunable laser spectrometer instruments of SAM are to work together with the other MSL investigations is to quantitatively assess habitability through a series of chemical and geological measurements. We describe the multi-column gas chromatograph system employed on SAM and the approach to extraction and analysis of organic compounds that might be preserved in ancient martian rocks.

Mahaffy, Paul↗

Regolith Particle Erosion of Material in Aerospace Environments

This paper studies the effect of exposing thermal control S13GP:6N/LO-I white paint, Kapton flex cable, fiber optic cable, HEPA filter, and M55J graphite composite to high-velocity regolith environment that spacecraft landing on Mars are commonly exposed to. Due to the similarity between the Mars 2020 Rover design and Mars Science Laboratory design, it is expected that the Mars 2020 rover will be exposed to a similar high-speed regolith environment that the Mars Science Laboratory was exposed to. This environment is replicated to test the survivability of susceptible materials. The testing is performed at the University of Dayton Research Institute in Dayton, Ohio. The experiments expose different materials to basaltic–like particles ranging in size from approximately 40 μm to 2 cm, at velocities ranging from 19 m/s to 250 m/s, with varied particle fluxes (measured in mg/cm2). Depending on the size of the particle used, the particles can either embed in or erode the material. Posttest analysis shows that all materials tested will survive the expected environment observed during the Mars 2020 landing event. Some materials are tested to failure in order to better characterize material response. Materials that fail in some test scenarios include the paint, fiber optic cable, and the graphite composite. After being exposed to regolith, the α/ε ratio of the paint increased by ~37% due to particles embedding in the paint. Darkening of the paint can negatively affect thermal control of the rover. With high particle mass fluxes, the paint eventually degraded enough to expose the aluminum substrate. When impacted by a 1.5 cm particle traveling at 20 m/s, the fiber optic cable did not sever, but the impact did cause the cable to deform enough to crack the glass, which resulted in a significant increase in attenuation, rendering the cable unable to transmit data. The graphite composite also failed when exposed to high particle fluxes. All of the observed failures occurred for test cases above the expected landing environment with significant margin. Tests performed beyond the requirements help characterize how well these materials will survive in even more extreme environments for future missions.

Abid, Mohamed↗

Implementation of a laser–neutron pump–probe capability for inelastic neutron scattering

Knowledge about nonequilibrium dynamics in spin systems is of great importance to both fundamental science and technological applications. Inelastic neutron scattering (INS) is an indispensable tool to study spin excitations in complex magnetic materials. However, conventional INS spectrometers currently only perform steady-state measurements and probe averaged properties over many collision events between spin excitations in thermodynamic equilibrium, while the exact picture of re-equilibration of these excitations remains unknown. In this paper, we report on the design and implementation of a time-resolved laser–neutron pump–probe capability at hybrid spectrometer (beamline 14-B) at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. This capability allows us to excite out-of-equilibrium magnons with a nanosecond pulsed laser source and probe the resulting dynamics using INS. Here, we discussed technical aspects to implement such a capability in a neutron beamline, including choices of suitable neutron instrumentation and material systems, laser excitation scheme, experimental configurations, and relevant firmware and software development to allow for time-synchronized pump–probe measurements. We demonstrated that the laser-induced nonequilibrium structure factor is able to be resolved by INS in a quantum magnet. In conclusion, the method developed in this work will provide SNS with advanced capabilities for performing out-of-equilibrium measurements, opening up an entirely new research direction to study out-of-equilibrium phenomena using neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NASA's Rodent Research Project: Validation of Capabilities for Conducting Long Duration Experiments in Space

Research using rodents is an essential tool for advancing biomedical research on Earth and in space. Prior rodent experiments on the Shuttle were limited by the short flight duration. The International Space Station (ISS) provides a new platform for conducting rodent experiments under long duration conditions. Rodent Research (RR)-1 was conducted to validate flight hardware, operations, and science capabilities that were developed at the NASA Ames Research Center. Twenty C57BL6J adult female mice were launched on Sept 21, 2014 in a Dragon Capsule (SpaceX-4), then transferred to the ISS for a total time of 21-22 days (10 commercial mice) or 37 days (10 validation mice). Tissues collected on-orbit were either rapidly frozen or preserved in RNAlater at -80C (n2group) until their return to Earth. Remaining carcasses on-orbit were rapidly frozen for dissection post-flight. The three controls groups at Kennedy Space Center consisted of: Basal mice euthanized at the time of launch, Vivarium controls housed in standard cages, and Ground Controls (GC) housed in flight hardware within an environmental chamber. Upon return to Earth, there were no differences in body weights between Flight (FLT) and GC at the end of the 37 days in space. Liver enzyme activity levels of FLT mice and all control mice were similar in magnitude to those of the samples that were processed under optimal conditions in the laboratory. Liver samples dissected on-orbit yielded high quality RNA (RIN8.99+-0.59, n7). Liver samples dissected post-flight from the intact, frozen FLT carcasses yielded RIN of 7.27 +- 0.52 (n6). Additionally, wet weights of various tissues were measured. Adrenal glands and spleen showed no significant differences in FLT compared to GC although thymus and livers weights were significantly greater in FLT compared to GC. Over 3,000 tissue aliquots collected post-flight from the four groups of mice were deposited into the Ames Life Science Data Archives for future Biospecimen Sharing Program. Together, the RR validation flight successfully demonstrates the capability to support long-duration experimentation on the ISS to achieve both basic science and biomedical objectives.

spaceflight↗

Detection of Critical Surface Features in PTLs and GDLs for Improved Device Performance and Manufacturing Reliability

High points, or features that protrude above the surface of the material, on porous transport layers (PTLs) and gas diffusion layers (GDLs) can be critical features that may affect the manufacturing process and the performance of the device containing the feature. High points on PTLs and GDLs may stress the membrane of a polymer electrolyte membrane (PEM) during lamination and cell operation of a PEM electrolyzer or fuel cell. Additionally, high points on GDLs may impact the reliability of the manufacturing process. Thus, understanding these critical features and developing procedures to detect them are a key part of developing quality control techniques for PTLs and GDLs. This work evaluates the effectiveness of the Keyence VR6200 benchtop-scale structured light optical profilometer for detection of surface protrusions on PTLs and GDLs. Standard testing procedures for detecting and measuring high points were created for use on both material types. These procedures were evaluated using Gage Repeatability and Reproducibility (Gage R&R), where the repeatability, reproducibility, and effectiveness of the system to detect and measure high points were quantified. We have shown with high statistical power that the system is very effective in detection and measurement of high points, with Gage R&R contributions measured to be 2.2% and 3.6% for PTLs and GDLs, respectively.

36 MATERIALS SCIENCE↗

X-ray Vision for Aerosol Scientists: LCLS Snapshots of Soot (Narrated)

This short conceptual animation depicts how scientists can now simultaneously capture fractal morphology (structure), chemical composition and nanoscale imagery of individual aerosol particles in flight. These particles, known as "PM2.5" because they are smaller than 2.5 microns in diameter, affect climate by interacting with sunlight and impact human health by entering the lungs. The single LCLS laser pulses travel to the Atomic, Molecular and Optical Sciences (AMO) laboratory in the Near Experimental Hall. As we zoom in, we see deep inside a simplified aerosol inlet, where the complex fractal structure of the soot particles, each one completely unique, is shown. Individual soot particles are then delivered into the pulses of the LCLS beam, which destroys them. X-rays are scattered to the detector before the particle is destroyed, giving information about the morphology of the particle. Ion fragments released in the explosion are sent into a mass spectrometer, which measures their mass-to-charge ratio -- giving scientists information about the chemical composition of the particle. Many different particles are analyzed in this manner, allowing scientists to probe variations in the particles due to changes in their environment before being sent through the aerosol inlet. The final visual of aerosols emitted from a factory is representative of the goal that such LCLS aerosol dynamics experiments can provide critical feedback into modeling and understanding combustion, aerosol processes in manufacturing or aerosol effects on climate change.

60 APPLIED LIFE SCIENCES↗

Behavioral Health and Performance Laboratory Standard Measures (BHP-SM)

The Spaceflight Standard Measures is a NASA Johnson Space Center Human Research Project (HRP) project that proposes to collect a set of core measurements, representative of many of the human spaceflight risks, from astronauts before, during and after long-duration International Space Station (ISS) missions. The term "standard measures" is defined as a set of core measurements, including physiological, biochemical, psychosocial, cognitive, and functional, that are reliable, valid, and accepted in terrestrial science, are associated with a specific and measurable outcome known to occur as a consequence of spaceflight, that will be collected in a standardized fashion from all (or most) crewmembers. While such measures might be used to define standards of health and performance or readiness for flight, the prime intent in their collection is to allow longitudinal analysis of multiple parameters in order to answer a variety of operational, occupational, and research-based questions. These questions are generally at a high level, and the approach for this project is to populate the standard measures database with the smallest set of data necessary to indicate further detailed research is required. Also included as standard measures are parameters that are not outcome-based in and of-themselves, but provide ancillary information that supports interpretation of the outcome measures, e.g., nutritional assessment, vehicle environmental parameters, crew debriefs, etc. The project's main aim is to ensure that an optimized minimal set of measures is consistently captured from all ISS crewmembers until the end of Station in order to characterize the human in space. -This allows the HRP to identify, establish, and evaluate a common set of measures for use in spaceflight and analog research to: develop baselines, systematically characterize risk likelihood and consequences, and assess effectiveness of countermeasures that work for behavioral health and performance risk factors. -By standardizing the battery of measures on all crewmembers, it will allow the HRP to evaluate countermeasures that work for one physiological system and ensure another system is not negatively affected. -These measures, named "Standard Measures," will serve as a data repository and be available to other studies under data sharing agreements.

Williams, Thomas J.↗

Low energy inelastic neutron scattering (INS) data of SrCoGe2O6 taken at CNCS chopper spectrometer.

INS measurements were performed using the Cold Neutron Chopper Spectrometer CNCS at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. A powder sample of SrCoGe2O6 was loaded in an aluminum can for the measurements and a standard orange cryostat was used to cover the temperature region from 1.7 K to 100 K. Data were collected using fixed incident neutron energy of 5.0 meV.

MATERIALS SCIENCE↗

Catalytic Pulping of Wood

The pulp and paper industry is an essential segment of the U.S. economy, making products necessary for everyday life from renewable resources. Lignin is a naturally occurring polymer in wood that must be removed to expose the polysaccharides used in the pulping industry to produce paper products. Kraft pulping, the predominant technology, is capital- and energy-intensive, and it provides a less efficient use of wood resources than desired. Catalytic methods offer a viable alternative to increase cellulose fiber yield by improving selectivity, reducing energy use and eliminating the formation of odor-causing mercaptans associated with kraft pulping. If successful, catalytic methods will improve yield, reduce fiber waste, reduce energy use, lower the cost of bleaching and decrease the cost of air emission controls. The purpose of this CRADA was to combine industrial expertise in wood pulping with national laboratory expertise in high-performance computing eventually leading to the design of new catalysts that can remove lignin from wood pulp efficiently and cost-effectively. A combined computational and experimental approach was used to investigate the detailed chemical mechanism of oxidation of ligninlike small molecules by a cobalt-based catalyst. These reactions were also investigated in the laboratory by synthesizing the catalyst and lignin-like phenols and measuring reaction yields for the formation of benzoquinones and benzaldehydes. In this report we summarize the accomplishments of the project.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Capillary Isotachophoresis-Nanoelectrospray Ionization-Selected Reaction Monitoring MS via a Novel Sheathless Interface for High Sensitivity Sample Quantification

A novel sheathless CITP/CZE-MS interface featuring a large i.d. separation capillary and a detachable small i.d. ESI emitter was developed in this study to simultaneously achieve large sample loading capacity and stable nanoESI operation. Crucial operating parameters, including sample loading volume, flow rate, and separation window, were systematically investigated to attain optimum CITP/CZE separation efficiency and MS detection sensitivity. The performance of CITP/CZE-nanoESI-MS using the new sheathless interface was evaluated for its achievable low limit of quantitation (LOQ) by analyzing targeted peptides, leu-enkephalin and angiotensin II, spiked in a BSA tryptic digest matrix at different concentrations. A linear dynamic range spanning 4.5 orders of magnitude and a 10 pM LOQ with excellent measurement reproducibility were obtained experimentally for both targeted peptides, representing a 5-fold sensitivity improvement as compared to using the sheath liquid interface developed previously.

Environmental Molecular Sciences Laboratory↗

A Preorganized Hydrogen Bond Network and Its Effect on Anion Stability

Rigid tricyclic locked in all axial 1,3,5-cyclohexanetriol derivatives with 0–3 trifluoromethyl groups were synthesized and photoelectron spectra of their conjugate bases and chloride anion clusters are reported along with density functional computations. The resulting vertical and adiabatic detachment energies provide measures of the anion stabilization due to the hydrogen bond network and inductive effects. The latter mechanism is found to be transmitted through space via hydrogen bonds

Environmental Molecular Sciences Laboratory↗

Structural Insights into the Interaction Between a Potent Anti-Inflammatory Protein, Viral CC Chemokine Inhibitor (vCCI), and the Human CC Chemokine, Eotaxin-1

Chemokines play important roles in the immune system, not only recruiting leukocytes to the site of infection and inflammation but also guiding cell homing and cell development. The soluble poxvirusencoded protein vCCI, a CC chemokine inhibitor, can bind to human CC chemokines tightly to impair the host immune defense. This protein has no known homologs in eukaryotes, and may represent a potent method to stop inflammation. Previously, our structure of the vCCI:MIP-1β complex indicated that vCCI uses negatively charged residues in β-sheet II to interact with positively charged residues in the MIP-1βN-terminus, 20’s region and 40’s loop. However, the interactions between vCCI and other CC chemokines have not yet been fully explored. Here, we used NMR and fluorescence anisotropy to study the interaction between vCCI and eotaxin-1 (CCL11), another CC chemokine that is an important factor in the asthma response. NMR results reveal that the binding pattern is very similar to the vCCI:MIP-1βcomplex, and suggest that electrostatic interactions provide a major contribution to binding. Fluorescence anisotropy results on variants of eotaxin-1 further confirm the critical roles of the charged residues in eotaxin. Compared to wild-type eotaxin, single, double, or triple mutations at these critical charged residues weaken the binding. One exception is the K47A mutation that exhibits increased affinity for vCCI, which can be explained structurally. In addition, the binding affinity between vCCI and other wild type CC chemokines, MCP-1, MIP-1β and RANTES, were determined as 1.09 nM, 1.16 nM, and 0.22 nM, respectively. To our knowledge, this is the first work quantitatively measuring the binding affinity between vCCI and different CC chemokines.

anti-inflammatory protein↗

The development and evolution of biological AMS at Livermore: a perspective

Biological accelerator mass spectrometry (AMS) provides ultrasensitive carbon-14 isotopic analysis enabling a deeper understanding of human health concerns by enabling quantification of pharmacokinetics and other molecular endpoints directly in humans. It enables environmentally and human relevant studies of metabolic pathways through the use of very low concentrations of labeled metabolic substrates in cells and organisms. Here, we discuss why AMS is an important tool for the biosciences, the development and evolution of biological AMS at Livermore and discuss technical refinements that will improve the efficiency of operation for the measurement of ultra-trace levels of 14 C, which, long term, will enable greater ease of use and sample throughput.

47 OTHER INSTRUMENTATION↗

Soil Organic Matter (SOM): Mass Spectrometry Data Analysis

Considered a general purpose tool for characterization of samples at the molecular level in environmental and life sciences, mass spectrometry (MS) is commonly used for measuring organic matter in air, water and soil. Broad base of commercially available instrumentation and data analysis tools provide functional analytical platforms for molecular characterization for a variety of applications and samples. MS instrumentation with ultrahigh resolving power (m/ΔmFWHM > 200 000) is necessary for broad identification of thousands of molecular components present in organic matter samples. This article discusses basic principles of data analysis for ultrahigh resolution MS measurements of small molecules of organic matter.

Environmental Molecular Sciences Laboratory↗

Real-time neutron multiplicity and source localization for criticality safety during fuel debris removal

Advancing neutron detection and analysis techniques for complex radiation environments is an ongoing focus in nuclear instrumentation and monitoring. This proposal presents research and development of a generalized real-time neutron monitoring and analysis system, applicable to any detector capable of producing time-tagged neutron count data. While the work is demonstrated using the Neutron Multiplication Analysis Detector (NoMAD), a modular 15-tube helium-3 (He-3) array, due to its availability, spatial resolution, and flexible deployment, the methods developed are extensible to other systems, including organic scintillators and fast digital detectors. This research investigates two complementary analytical techniques for real-time characterization of neutron emitting sources: neutron multiplicity estimation based on the Hage-Cifarelli formalism and spatial localization using supervised machine learning applied to spatial count rate patterns. These methods are designed to operate under dynamic, evolving conditions such as fuel debris retrieval or reactor startup, where neutron-emitting material geometries may be partially unknown or changing over time. By integrating statistical neutron emission data with spatial localization, this research aims to develop and evaluate methods for real time neutron monitoring, source characterization, and material verification. Key contributions include implementation of a low-latency data pipeline for continuous neutron multiplicity analysis, development and validation of machine learning models for spatial inference, and experimental evaluation of system performance under variable measurement conditions. The outcomes are intended to support applications in nuclear safeguards, verification, emergency response, and reactor startup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-19A-02: Comparison of Absorbed Dose to Water Standards for HDR Ir-192 Brachytherapy Between the LCR, Brazil and NRC, Canada

Purpose: To compare absorbed dose to water standards for HDR brachytherapy dosimetry developed by the Radiological Science Laboratory of Rio de Janeiro State University (LCR) and the National Research Council, Canada (NRC). Methods: The two institutions have separately developed absorbed dose standards based on the Fricke dosimetry system. There are important differences between the two standards, including: preparation and read-out of the Fricke solution, irradiation geometry of the Fricke holder in relation to the Ir-192 source, and determination of the G-value to be used at Ir-192 energies. All measurements for both standards were made directly at the NRC laboratory (i.e., no transfer instrument was used) using a single Ir-192 source (microSelectron v2). In addition, the NRC group has established a self-consistent method to determine the G-value for Ir-192, based on an interpolation between G-values obtained at Co-60 and 250kVp X-rays, and this measurement was repeated using the LCR Fricke solution to investigate possible systematic uncertainties. Results: G-values for Co-60 and 250 kVp x-rays, obtained using the LCR Fricke system, agreed with the NRC values within 0.5 % and 1 % respectively, indicating that the general assumption of universal G-values is appropriate in this case. The standard uncertainty in the determination of G for Ir-192 is estimated to be 0.6 %. For the comparison of absorbed dose measurements at the reference point for Ir-192 (1 cm depth in water, perpendicular to the seed long-axis), the ratio Dw(NRC)/Dw(LCR) was found to be 1.011 with a combined standard uncertainty of 1.7 %, k=1. Conclusion: The agreement in the absorbed dose to water values for the LCR and NRC systems is very encouraging. Combined with the lower uncertainty in this approach compared to the present air-kerma approach, these results reaffirm the use of Fricke solution as a potential primary standard for HDR Ir-192 brachytherapy.

07 ISOTOPE AND RADIATION SOURCES↗