Wind Tunnel to Atmospheric Mapping for Static Aeroelastic Scaling

Wind tunnel to Atmospheric Mapping (WAM) is a methodology for scaling and testing a static aeroelastic wind tunnel model. The WAM procedure employs scaling laws to define a wind tunnel model and wind tunnel test points such that the static aeroelastic flight test data and wind tunnel data will be correlated throughout the test envelopes. This methodology extends the notion that a single test condition - combination of Mach number and dynamic pressure - can be matched by wind tunnel data. The primary requirements for affecting this extension are matching flight Mach numbers, maintaining a constant dynamic pressure scale factor and setting the dynamic pressure scale factor in accordance with the stiffness scale factor. The scaling is enabled by capabilities of the NASA Langley Transonic Dynamics Tunnel (TDT) and by relaxation of scaling requirements present in the dynamic problem that are not critical to the static aeroelastic problem. The methodology is exercised in two example scaling problems: an arbitrarily scaled wing and a practical application to the scaling of the Active Aeroelastic Wing flight vehicle for testing in the TDT.

Heeg, Jennifer↗

Improved Temperature Dynamic Model of Turbine Subcomponents for Facilitation of Generalized Tip Clearance Control

This paper describes efforts conducted to improve dynamic temperature estimations of a turbine tip clearance system to facilitate design of a generalized tip clearance controller. This work builds upon research previously conducted and presented in and focuses primarily on improving dynamic temperature estimations of the primary components affecting tip clearance (i.e. the rotor, blades, and casing/shroud). The temperature profiles estimated by the previous model iteration, specifically for the rotor and blades, were found to be inaccurate and, more importantly, insufficient to facilitate controller design. Some assumptions made to facilitate the previous results were not valid, and thus improvements are presented here to better match the physical reality. As will be shown, the improved temperature sub- models, match a commercially validated model and are sufficiently simplified to aid in controller design.

Kypuros, Javier A.↗

JWST ISIM Distortion Analysis Challenge

Very tight distortion requirements are imposed on the JWST's ISM structure due to the sensitivity of the telescope's mirror segment and science instrument positioning. The ISIM structure is a three dimensional truss with asymmetric gusseting and metal fittings. One of the primary challenges for ISIM's analysis team is predicting the thermal distortion of the structure both from the bulk cooldown from ambient to cryo, and the smaller temperature changes within the cryogenic operating environment. As a first cut to estimate thermal distortions, a finite element model of bar elements was created. Elements representing joint areas and metal fittings use effective properties that match the behavior of the stack-up of the composite tube, gusset and adhesive under mechanical and thermal loads. These properties were derived by matching tip deflections of a solid model simplified T-joint. Because of the structure s asymmetric gusseting, this effective property model is a first attempt at predicting rotations that cannot be captured with a smeared CTE approach. In addition to the finite element analysis, several first order calculations have been performed to gauge the feasibility of the material design. Because of the stringent thermal distortion requirements at cryogenic temperatures, a composite tube material with near zero or negative CTE is required. A preliminary hand analysis of the contribution of the various components along the distortion path between FGS and the other instruments, neglecting second order effects were examined. A plot of bounding tube longitudinal and transverse CTEs for thermal stability requirements was generated to help determine the feasibility of meeting these requirements. This analysis is a work in progress en route to a large degree of freedom hi-fidelity FEA model for distortion analysis. Methods of model reduction, such as superelements, are currently being investigated.

Cifie, Emmanuel↗

Comparisons of Observations with Results from 3D Simulations and Implications for Predictions of Ozone Recovery

Although chemistry and transport models (CTMs) include the same basic elements (photo- chemical mechanism and solver, photolysis scheme, meteorological fields, numerical transport scheme), they produce different results for the future recovery of stratospheric ozone as chlorofluorcarbons decrease. Three simulations will be contrasted: the Global Modeling Initiative (GMI) CTM driven by a single year\'s winds from a general circulation model; the GMI CTM driven by a single year\'s winds from a data assimilation system; the NASA GSFC CTM driven by a winds from a multi-year GCM simulation. CTM results for ozone and other constituents will be compared with each other and with observations from ground-based and satellite platforms to address the following: Does the simulated ozone tendency and its latitude, altitude and seasonal dependence match that derived from observations? Does the balance from analysis of observations? Does the balance among photochemical processes match that expected from observations? Can the differences in prediction for ozone recovery be anticipated from these comparisons?

Douglass, Anne R.↗

Multi-Image Registration for an Enhanced Vision System

An Enhanced Vision System (EVS) utilizing multi-sensor image fusion is currently under development at the NASA Langley Research Center. The EVS will provide enhanced images of the flight environment to assist pilots in poor visibility conditions. Multi-spectral images obtained from a short wave infrared (SWIR), a long wave infrared (LWIR), and a color visible band CCD camera, are enhanced and fused using the Retinex algorithm. The images from the different sensors do not have a uniform data structure: the three sensors not only operate at different wavelengths, but they also have different spatial resolutions, optical fields of view (FOV), and bore-sighting inaccuracies. Thus, in order to perform image fusion, the images must first be co-registered. Image registration is the task of aligning images taken at different times, from different sensors, or from different viewpoints, so that all corresponding points in the images match. In this paper, we present two methods for registering multiple multi-spectral images. The first method performs registration using sensor specifications to match the FOVs and resolutions directly through image resampling. In the second method, registration is obtained through geometric correction based on a spatial transformation defined by user selected control points and regression analysis.

Hines, Glenn↗

Optimization of single-base-pair mismatch discrimination in oligonucleotide microarrays

The discrimination between perfect-match and single-base-pair-mismatched nucleic acid duplexes was investigated by using oligonucleotide DNA microarrays and nonequilibrium dissociation rates (melting profiles). DNA and RNA versions of two synthetic targets corresponding to the 16S rRNA sequences of Staphylococcus epidermidis (38 nucleotides) and Nitrosomonas eutropha (39 nucleotides) were hybridized to perfect-match probes (18-mer and 19-mer) and to a set of probes having all possible single-base-pair mismatches. The melting profiles of all probe-target duplexes were determined in parallel by using an imposed temperature step gradient. We derived an optimum wash temperature for each probe and target by using a simple formula to calculate a discrimination index for each temperature of the step gradient. This optimum corresponded to the output of an independent analysis using a customized neural network program. These results together provide an experimental and analytical framework for optimizing mismatch discrimination among all probes on a DNA microarray.

NASA Discipline Life Sciences Technologies↗

Comparison of two weighted integration models for the cueing task: linear and likelihood

In a task in which the observer must detect a signal at two locations, presenting a precue that predicts the location of a signal leads to improved performance with a valid cue (signal location matches the cue), compared to an invalid cue (signal location does not match the cue). The cue validity effect has often been explained with a limited capacity attentional mechanism improving the perceptual quality at the cued location. Alternatively, the cueing effect can also be explained by unlimited capacity models that assume a weighted combination of noisy responses across the two locations. We compare two weighted integration models, a linear model and a sum of weighted likelihoods model based on a Bayesian observer. While qualitatively these models are similar, quantitatively they predict different cue validity effects as the signal-to-noise ratios (SNR) increase. To test these models, 3 observers performed in a cued discrimination task of Gaussian targets with an 80% valid precue across a broad range of SNR's. Analysis of a limited capacity attentional switching model was also included and rejected. The sum of weighted likelihoods model best described the psychophysical results, suggesting that human observers approximate a weighted combination of likelihoods, and not a weighted linear combination.

NASA Program Biomedical Research and Countermeasur↗

Survival after aortic valve replacement for severe aortic stenosis with low transvalvular gradients and severe left ventricular dysfunction

OBJECTIVE: We sought to assess whether aortic valve replacement (AVR) among patients with severe aortic stenosis (AS), severe left ventricular (LV) dysfunction and a low transvalvular gradient (TVG) is associated with improved survival. BACKGROUND: The optimal management of patients with severe AS with severe LV dysfunction and a low TVG remains controversial. METHODS: Between 1990 and 1998, we evaluated 68 patients who underwent AVR at our institution (AVR group) and 89 patients who did not undergo AVR (control group), with an aortic valve area < or = 0.75 cm(2), LV ejection fraction < or = 35% and mean gradient < or = 30 mm Hg. Using propensity analysis, survival was compared between a cohort of 39 patients in the AVR group and 56 patients in the control group. RESULTS: Despite well-matched baseline characteristics among propensity-matched patients, the one- and four-year survival rates were markedly improved in patients in the AVR group (82% and 78%), as compared with patients in the control group (41% and 15%; p < 0.0001). By multivariable analysis, the main predictor of improved survival was AVR (adjusted risk ratio 0.19, 95% confidence interval 0.09 to 0.39; p < 0.0001). The only other predictors of mortality were age and the serum creatinine level. CONCLUSIONS: Among select patients with severe AS, severe LV dysfunction and a low TVG, AVR was associated with significantly improved survival.

NASA Discipline Cardiopulmonary↗

Mid-infrared trace gas detection using continuous-wave difference frequency generation in periodically poled RbTiOAsO4

A tunable mid-infrared continuous-wave (cw) spectroscopic source in the 3.4-4.5 micrometers region is reported, based on difference frequency generation (DFG) in a quasi-phase-matched periodically poled RbTiOAsO4 (PPRTA) crystal. DFG power levels of 10 microW were generated at approximately 4 micrometers in a 20-mm long PPRTA crystal by mixing two cw single-frequency Ti:Al2O3 lasers operating near 713 nm and 871 nm, respectively, using a laser pump power of 300 mW. A quasi-phase-matched infrared wavelength-tuning bandwidth (FWHM) of ~ 12 cm-1 and a temperature tuning rate of 1.02 cm-1/degree C were achieved. Experimental details regarding the feasibility of trace gas detection based on absorption spectroscopy of CO2 in ambient air using this DFG radiation source are also described.

NASA Discipline Life Sciences Technologies↗

A laboratory analog for the carrier of the 3 micron emission of the protoplanetary nebula IRAS 05341+0852

A mixture of the polycyclic aromatic hydrocarbons (PAHs), acenaphthylene and acenaphthene, when subjected to the energetic environment of a hydrogen plasma, is transformed into a material that exhibits an infrared absorption profile in the 3 micron region that is an excellent match of the protoplanetary nebula IRAS 05341+0852 emission profile in the same wavelength region. Acenaphthylene and acenaphthene were chosen as precursors in the experiment because these molecules have a structure that can be described as a keystone in a process in which carbon atoms in a stellar wind condense into PAH species. The spectral match between experiment and observations appears to validate that scenario.

Non-NASA Center↗

Laboratory comparisons of organic materials to interstellar dust and the Murchison meteorite

Spectra of objects which lie along several lines of sight through the diffuse interstellar medium (DISM) reveal an absorption feature near 3.4 micrometers, which has been attributed to saturated aliphatic hydrocarbons on interstellar grains. The similarity of the absorption bands near 3.4 micrometers (2950 cm-1) along different lines of sight indicates that the carrier of this band lies in the diffuse dust. Several materials have been proposed as "fits" to the 3.4 micrometers feature over the years. A comparison of these identifications is presented. These comparisons illustrate the need for high resolution, high signal-to-noise observational data as a means of distinguishing between laboratory organics as matches to the interstellar material. Although any material containing hydrocarbons will produce features in the 3.4 micrometers region, the proposed "matches" to the DISM do differ in detail. These differences may help in the analyses of the chemical composition and physical processes which led to the production of the DISM organics, although ISO Observations through the 5-8 micrometers spectral region are essential for a definitive identification. A remarkable similarity between the spectrum of the diffuse dust and an organic extract from the Murchison meteorite suggests that some of the interstellar organic material may be preserved in primitive solar system bodies. The 3.4 micrometers absorption feature (in the rest frame) has recently been detected in external galaxies, indicating the widespread availability of organic material for incorporation into planetary systems.

NASA Center ARC↗

The 2140 cm-1 (4.673 microns) solid CO band: the case for interstellar O2 and N2 and the photochemistry of nonpolar interstellar ice analogs

The infrared spectra of CO frozen in nonpolar ices containing N2, CO2, O2, and H2O and the UV photochemistry of these interstellar/precometary ice analogs are reported. The spectra are used to test the hypothesis that the narrow 2140 cm-1 (4.673 microns) interstellar absorption feature attributed to solid CO might be produced by CO frozen in ices containing nonpolar species such as N2 and O2. It is shown that mixed molecular ices containing CO, N2, O2, and CO2 provide a good match to the interstellar band at all temperatures between 12 and 30 K both before and after photolysis. The optical constants (real and imaginary parts of the index of refraction) in the region of the solid CO feature are reported for several of these ices. The N2 and O2 absorptions at 2328 cm-1 (4.296 microns) and 1549 cm-1 (6.456 microns), respectively, are also shown. The best matches between the narrow interstellar band and the feature in the laboratory spectra of nonpolar ices are for samples which contain comparable amounts of N2, O2, CO2, and CO. Co-adding the CO band from an N2:O2:CO2:CO = 1:5:1/2:1 ice with that of an H2O:CO = 20:1 ice provides an excellent fit across the entire interstellar CO feature. The four-component, nonpolar ice accounts for the narrow 2140 cm-1 portion of the feature which is associated with quiescent regions of dense molecular clouds. Using this mixture, and applying the most recent cosmic abundance values, we derive that between 15% and 70% of the available interstellar N is in the form of frozen N2 along several lines of sight toward background stars. This is reduced to a range of 1%-30% for embedded objects with lines of sight more dominated by warmer grains. The cosmic abundance of O tied up in frozen O2 lies in the 10%-45% range toward background sources, and it is between 1% and 20% toward embedded objects. The amount of oxygen tied up in CO and CO2 frozen in nonpolar ices can be as much as 2%-10% toward background sources and on the order of 0.2%-5% for embedded objects. Similarly 3%-13% of the carbon is tied up in CO and CO2 frozen in nonpolar ices toward field stars, and 0.2%-6% toward embedded objects. These numbers imply that most of the N is in N2, and a significant fraction of the available O is in O2 in the most quiescent regions of dense clouds. Ultraviolet photolysis of these ices produces a variety of photoproducts including CO2, N2O, O3, CO3, HCO, H2CO, and possibly NO and NO2. XCN is not produced in these experiments, placing important constraints on the origin of the enigmatic interstellar XCN feature. N2O and CO3 have not been previously considered as interstellar ice components.

NASA Discipline Exobiology↗

Testing the PV-Theta Mapping Technique in a 3-D CTM Model Simulation

Mapping lower stratospheric ozone into potential vorticity (PV)- potential temperature (Theta) coordinates is a common technique employed to analyze sparse data sets. Ozone transformed into a flow-following dynamical coordinate system is insensitive to meteorological variations. Therefore data from a wide range of times/locations can be compared, so long as the measurements were made in the same airmass (as defined by PV). Moreover, once a relationship between ozone and PV/Theta is established, a full 3D ozone field can be estimated from this relationship and the 3D analyzed PV field. However, ozone data mapped in this fashion can be hampered by noisy PV fields, or "mis-matches" in the resolution and/or exact location of the ozone and PV measurements. In this study, we investigate the PV-ozone relationship using output from a recent 50-year run of the Goddard 3D chemical transport model (CTM). Model constituents are transported using off-line dynamics from the finite volume general circulation model (FVGCM). By using the internally consistent model PV and ozone fields, we minimize noise due to mis-matching and resolution issues. We calculate correlations between model ozone and PV throughout the stratosphere, and test the sensitivity of the technique to initial data resolution. To do this we degrade the model data to that of various satellite instruments, then compare the mapped fields derived from the sub-sampled data to the full resolution model data. With these studies we can determine appropriate limits for the PV-theta mapping technique in latitude, altitude, and as a function of original data resolution.

Frith, Stacey M.↗

Autogenic-feedback training exercise is superior to promethazine for control of motion sickness symptoms

Motion sickness symptoms affect approximately 50% of the crew during space travel and are commonly treated with intramuscular injections of promethazine. The purpose of this paper is to compare the effectiveness of three treatments for motion sickness: intramuscular injections (i.m.) of promethazine, a physiological training method (autogenic-feedback training exercise [AFTE]), and a no-treatment control. An earlier study tested the effects of promethazine on cognitive and psychomotor performance and motion sickness tolerance in a rotating chair. For the present paper, motion sickness tolerance, symptom reports, and physiological responses of these subjects were compared to matched subjects selected from an existing database who received either AFTE or no treatment. Three groups of 11 men, between the ages of 33 and 40 years, were matched on the number of rotations tolerated during their initial rotating-chair motion sickness test. The motion sickness test procedures and the 7-day interval between tests were the same for all subjects. The drug group was tested under four treatment conditions: baseline (no injections), a 25 mg dose of promethazine, a 50 mg dose of promethazine, and a placebo of sterile saline. AFTE subjects were given four 30-minute AFTE sessions before their second, third, and fourth motion sickness tests (6 hours total). The no-treatment control subjects were only given the four rotating-chair tests. Motion sickness tolerance was significantly increased after 4 hours of AFTE when compared to either 25 mg (p < 0.00003) or 50 mg (p < 0.00001) of promethazine. The control and promethazine groups did not differ. AFTE subjects reported fewer or no symptoms at higher rotational velocities than subjects in the control or promethazine groups. The primary physiological effect of promethazine was an inhibition of skin conductance level. The AFTE group showed significantly less heart rate and skin conductance variability during motion sickness tests administered after training.

Clinical Trial↗

Optical properties of poly-HCN and their astronomical applications

Matthews (1992) has proposed that HCN "polymer" is ubiquitous in the solar system. We apply vacuum deposition and spectroscopic techniques previously used on synthetic organic heteropolymers (tholins), kerogens, and meteoritic organic residues to the measurement of the optical constants of poly-HCN in the wavelength range 0.05-40 micrometers. These measurements allow quantitative comparison with spectrophotometry of organic-rich bodies in the outer solar system. In a specific test of Matthews' hypothesis, poly-HCN fails to match the optical constants of the haze of the Saturnian moon, Titan, in the visible and near-infrared derived from astronomical observations and standard models of the Titan atmosphere. In contrast, a tholin produced from a simulated Titan atmosphere matches within the probable errors. Poly-HCN is much more N-rich than Titan tholin.

Optics↗

Regional ventilation-perfusion distribution is more uniform in the prone position

The arterial blood PO(2) is increased in the prone position in animals and humans because of an improvement in ventilation (VA) and perfusion (Q) matching. However, the mechanism of improved VA/Q is unknown. This experiment measured regional VA/Q heterogeneity and the correlation between VA and Q in supine and prone positions in pigs. Eight ketamine-diazepam-anesthetized, mechanically ventilated pigs were studied in supine and prone positions in random order. Regional VA and Q were measured using fluorescent-labeled aerosols and radioactive-labeled microspheres, respectively. The lungs were dried at total lung capacity and cubed into 603-967 small ( approximately 1.7-cm(3)) pieces. In the prone position the homogeneity of the ventilation distribution increased (P = 0.030) and the correlation between VA and Q increased (correlation coefficient = 0.72 +/- 0.08 and 0.82 +/- 0.06 in supine and prone positions, respectively, P = 0.03). The homogeneity of the VA/Q distribution increased in the prone position (P = 0.028). We conclude that the improvement in VA/Q matching in the prone position is secondary to increased homogeneity of the VA distribution and increased correlation of regional VA and Q.

NASA Program Biomedical Research and Countermeasur↗

Development of a hydraulic model of the human systemic circulation

Physical and numeric models of the human circulation are constructed for a number of objectives, including studies and training in physiologic control, interpretation of clinical observations, and testing of prosthetic cardiovascular devices. For many of these purposes it is important to quantitatively validate the dynamic response of the models in terms of the input impedance (Z = oscillatory pressure/oscillatory flow). To address this need, the authors developed an improved physical model. Using a computer study, the authors first identified the configuration of lumped parameter elements in a model of the systemic circulation; the result was a good match with human aortic input impedance with a minimum number of elements. Design, construction, and testing of a hydraulic model analogous to the computer model followed. Numeric results showed that a three element model with two resistors and one compliance produced reasonable matching without undue complication. The subsequent analogous hydraulic model included adjustable resistors incorporating a sliding plate to vary the flow area through a porous material and an adjustable compliance consisting of a variable-volume air chamber. The response of the hydraulic model compared favorably with other circulation models.

NASA Program Biomedical Research and Countermeasur↗

Abnormalities of the QT interval in primary disorders of autonomic failure

BACKGROUND: Experimental evidence shows that activation of the autonomic nervous system influences ventricular repolarization and, therefore, the QT interval on the ECG. To test the hypothesis that the QT interval is abnormal in autonomic dysfunction, we examined ECGs in patients with severe primary autonomic failure and in patients with congenital dopamine beta-hydroxylase (DbetaH) deficiency who are unable to synthesize norepinephrine and epinephrine. SUBJECTS AND METHODS: Maximal QT and rate-corrected QT (QTc) intervals and adjusted QTc dispersion [(maximal QTc - minimum QTc on 12 lead ECG)/square root of the number of leads measured] were determined in blinded fashion from ECGs of 67 patients with primary autonomic failure (36 patients with multiple system atrophy [MSA], and 31 patients with pure autonomic failure [PAF]) and 17 age- and sex-matched healthy controls. ECGs of 5 patients with congenital DbetaH deficiency and 6 age- and sex-matched controls were also analyzed. RESULTS: Patients with MSA and PAF had significantly prolonged maximum QTc intervals (492+/-58 ms(1/2) and 502+/-61 ms(1/2) [mean +/- SD]), respectively, compared with controls (450+/-18 ms(1/2), P < .05 and P < .01, respectively). A similar but not significant trend was observed for QT. QTc dispersion was also increased in MSA (40+/-20 ms(1/2), P < .05 vs controls) and PAF patients (32+/-19 ms(1/2), NS) compared with controls (21+/-5 ms(1/2)). In contrast, patients with congenital DbetaH deficiency did not have significantly different RR, QT, QTc intervals, or QTc dispersion when compared with controls. CONCLUSIONS: Patients with primary autonomic failure who have combined parasympathetic and sympathetic failure have abnormally prolonged QT interval and increased QT dispersion. However, QT interval in patients with congenital DbetaH deficiency was not significantly different from controls. It is possible, therefore, that QT abnormalities in patients with primary autonomic failure are not solely caused by lesions of the sympathetic nervous system, and that the parasympathetic nervous system is likely to have a modulatory role in ventricular repolarization.