Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MICROWAVES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Microwave Passive Ground-Based Retrievals of Cloud and Rain Liquid Water Path in Drizzling Clouds: Challenges and Possibilities

Satellite and ground-based microwave radiometers are routinely used for the retrieval of liquid water path (LWP) under all atmospheric conditions. The retrieval of water vapor and LWP from ground-based radiometers during rain has proved to be a difficult challenge for two principal reasons: the inadequacy of the nonscattering approximation in precipitating clouds and the deposition of rain drops on the instrument's radome. In this paper, we combine model computations and real ground-based, zenith-viewing passive microwave radiometer brightness temperature measurements to investigate how total, cloud, and rain LWP retrievals are affected by assumptions on the cloud drop size distribution (DSD) and under which conditions a nonscattering approximation can be considered reasonably accurate. Results show that until the drop effective diameter is larger than similar to 200 mu m, a nonscattering approximation yields results that are still accurate at frequencies less than 90 GHz. For larger drop sizes, it is shown that higher microwave frequencies contain useful information that can be used to separate cloud and rain LWP provided that the vertical distribution of hydrometeors, as well as the DSD, is reasonably known. The choice of the DSD parameters becomes important to ensure retrievals that are consistent with the measurements. A physical retrieval is tested on a synthetic data set and is then used to retrieve total, cloud, and rain LWP from radiometric measurements during two drizzling cases at the atmospheric radiation measurement Eastern North Atlantic site.

54 ENVIRONMENTAL SCIENCES↗

New Trends in Microwave Imaging Diagnostics and Application to Burning Plasma

Microwave and millimeter-wave (mm-wave)-based diagnostics have proven invaluable in the understanding of magnetic confinement fusion plasma science and have found wide application at major fusion facilities, including DIII-D, EAST, ASDEX-U, HL-2A, KSTAR, and J-TEXT. This trend is expected to continue unabated in future burning plasma devices such as ITER and DEMO. Attractive features include their nonperturbing nature and relatively modest access requirements due to their short wavelength, as well as recent dramatic advances in the state of the technology. In this tutorial, we describe the basic principles of a number of microwave diagnostics measurements emphasizing imaging, recent technology advances including the so-called “system-on-chip (SoC)” technology, and “synthetic” diagnostics which simulate the response of diagnostics under actual experimental scenarios. In conclusion, the application of microwave diagnostics on reactor plasmas benefits immensely from the development of wide-bandgap electronics and advanced optics designs, both of which ameliorate the effects of the harsh environment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microwave absorption properties of Mn- and Ni-doped zinc oxides

Microwave absorption properties of Mn- and Ni-doped zinc oxides were assessed in this study. Samples were prepared by the decomposition of acetate solid solutions. By changing the concentration of dopant ions in the reaction solutions, zinc oxides with different amounts of dopant were obtained. The morphologies, chemical compositions, and structures of the samples were investigated by scanning electron microscopy, energy dispersive x-ray spectroscopy, and x-ray powder diffraction. Electromagnetic characteristics of the doped samples were assessed by vector network analysis at a frequency range of 2-16 GHz. Both the real and imaginary parts of the complex permittivity decreased as Mn or Ni concentration increased. Results indicate that, compared with pure ZnO, Mn- and Ni-doped zinc oxides exhibit excellent microwave absorption properties. The highest level of microwave absorption observed was 80.7 dB at a frequency of 9.8 GHz, and the best frequency bandwidth was 8.6 GHz at reflection loss values below -10 dB.

36 MATERIALS SCIENCE↗

Surface scanning through a cylindrical tank of coupling fluid for clinical microwave breast imaging exams

Purpose: Microwave tomographic image quality can be improved significantly with prior knowledge of the breast surface geometry. The authors have developed a novel laser scanning system capable of accurately recovering surface renderings of breast-shaped phantoms immersed within a cylindrical tank of coupling fluid which resides completely external to the tank (and the aqueous environment) and overcomes the challenges associated with the optical distortions caused by refraction from the air, tank wall, and liquid bath interfaces. Methods: The scanner utilizes two laser line generators and a small CCD camera mounted concentrically on a rotating gantry about the microwave imaging tank. Various calibration methods were considered for optimizing the accuracy of the scanner in the presence of the optical distortions including traditional ray tracing and image registration approaches. In this paper, the authors describe the construction and operation of the laser scanner, compare the efficacy of several calibration methods-including analytical ray tracing and piecewise linear, polynomial, locally weighted mean, and thin-plate-spline (TPS) image registrations-and report outcomes from preliminary phantom experiments. Results: The results show that errors in calibrating camera angles and position prevented analytical ray tracing from achieving submillimeter accuracy in the surface renderings obtained from our scanner configuration. Conversely, calibration by image registration reliably attained mean surface errors of less than 0.5 mm depending on the geometric complexity of the object scanned. While each of the image registration approaches outperformed the ray tracing strategy, the authors found global polynomial methods produced the best compromise between average surface error and scanner robustness. Conclusions: The laser scanning system provides a fast and accurate method of three dimensional surface capture in the aqueous environment commonly found in microwave breast imaging. Optical distortions imposed by the imaging tank and coupling bath diminished the effectiveness of the ray tracing approach; however, calibration through image registration techniques reliably produced scans of submillimeter accuracy. Tests of the system with breast-shaped phantoms demonstrated the successful implementation of the scanner for the intended application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reducing the effects of acoustic heterogeneity with an iterative reconstruction method from experimental data in microwave induced thermoacoustic tomography

Purpose: An iterative reconstruction method has been previously reported by the authors of this paper. However, the iterative reconstruction method was demonstrated by solely using the numerical simulations. It is essential to apply the iterative reconstruction method to practice conditions. The objective of this work is to validate the capability of the iterative reconstruction method for reducing the effects of acoustic heterogeneity with the experimental data in microwave induced thermoacoustic tomography. Methods: Most existing reconstruction methods need to combine the ultrasonic measurement technology to quantitatively measure the velocity distribution of heterogeneity, which increases the system complexity. Different to existing reconstruction methods, the iterative reconstruction method combines time reversal mirror technique, fast marching method, and simultaneous algebraic reconstruction technique to iteratively estimate the velocity distribution of heterogeneous tissue by solely using the measured data. Then, the estimated velocity distribution is used subsequently to reconstruct the highly accurate image of microwave absorption distribution. Experiments that a target placed in an acoustic heterogeneous environment are performed to validate the iterative reconstruction method. Results: By using the estimated velocity distribution, the target in an acoustic heterogeneous environment can be reconstructed with better shape and higher image contrast than targets that are reconstructed with a homogeneous velocity distribution. Conclusions: The distortions caused by the acoustic heterogeneity can be efficiently corrected by utilizing the velocity distribution estimated by the iterative reconstruction method. The advantage of the iterative reconstruction method over the existing correction methods is that it is successful in improving the quality of the image of microwave absorption distribution without increasing the system complexity.

60 APPLIED LIFE SCIENCES↗

Microwave ablation at 915 MHz vs 2.45 GHz: A theoretical and experimental investigation

Purpose: The relationship between microwave ablation system operating frequency and ablation performance is not currently well understood. The objective of this study was to comparatively assess the differences in microwave ablation at 915 MHz and 2.45 GHz. Methods: Analytical expressions for electromagnetic radiation from point sources were used to compare power deposition at the two frequencies of interest. A 3D electromagnetic-thermal bioheat transfer solver was implemented with the finite element method to characterize power deposition and thermal ablation with asymmetrical insulated dipole antennas (single-antenna and dual-antenna synchronous arrays). Simulation results were validated against experiments in ex vivo tissue. Results: Theoretical, computational, and experimental results indicated greater power deposition and larger diameter ablation zones when using a single insulated microwave antenna at 2.45 GHz; experimentally, 32 ± 4.1 mm and 36.3 ± 1.0 mm for 5 and 10 min, respectively, at 2.45 GHz, compared to 24 ± 1.7 mm and 29.5 ± 0.6 mm at 915 MHz, with 30 W forward power at the antenna input port. In experiments, faster heating was observed at locations 5 mm (0.91 vs 0.49 °C/s) and 10 mm (0.28 vs 0.15 °C/s) from the antenna operating at 2.45 GHz. Larger ablation zones were observed with dual-antenna arrays at 2.45 GHz; however, the differences were less pronounced than for single antennas. Conclusions: Single- and dual-antenna arrays systems operating at 2.45 GHz yield larger ablation zone due to greater power deposition in proximity to the antenna, as well as greater role of thermal conduction.

60 APPLIED LIFE SCIENCES↗

3D microwave tomography of the breast using prior anatomical information

Purpose: The authors have developed a new 3D breast image reconstruction technique that utilizes the soft tissue spatial resolution of magnetic resonance imaging (MRI) and integrates the dielectric property differentiation from microwave imaging to produce a dual modality approach with the goal of augmenting the specificity of MR imaging, possibly without the need for nonspecific contrast agents. The integration is performed through the application of a soft prior regularization which imports segmented geometric meshes generated from MR exams and uses it to constrain the microwave tomography algorithm to recover nearly uniform property distributions within segmented regions with sharp delineation between these internal subzones. Methods: Previous investigations have demonstrated that this approach is effective in 2D simulation and phantom experiments and also in clinical exams. The current study extends the algorithm to 3D and provides a thorough analysis of the sensitivity and robustness to misalignment errors in size and location between the spatial prior information and the actual data. Results: Image results in 3D were not strongly dependent on reconstruction mesh density, and the changes of less than 30% in recovered property values arose from variations of more than 125% in target region size—an outcome which was more robust than in 2D. Similarly, changes of less than 13% occurred in the 3D image results from variations in target location of nearly 90% of the inclusion size. Permittivity and conductivity errors were about 5 times and 2 times smaller, respectively, with the 3D spatial prior algorithm in actual phantom experiments than those which occurred without priors. Conclusions: The presented study confirms that the incorporation of structural information in the form of a soft constraint can considerably improve the accuracy of the property estimates in predefined regions of interest. These findings are encouraging and establish a strong foundation for using the soft prior technique in clinical studies, where their microwave imaging system and MRI can simultaneously collect breast exam data in patients.

60 APPLIED LIFE SCIENCES↗

Effect of photoions on the line shape of the Foerster resonance lines and microwave transitions in cold rubidium Rydberg atoms

Experiments are carried out on the spectroscopy of the Foerster resonance lines Rb(37P) + Rb(37P) {yields} Rb(37S) + Rb(38S) and microwave transitions nP {yields} n Prime S, n Prime D between Rydberg states of cold rubidium atoms in a magneto-optical trap (MOT). Under ordinary conditions, all spectra exhibit a linewidth of 2-3 MHz irrespective of the interaction time between atoms or between atoms and microwave radiation, although the limit resonance width should be determined by the inverse interaction time. The analysis of experimental conditions has shown that the main source of line broadening is the inhomogeneous electric field of cold photoions that are generated under the excitation of initial nP Rydberg states by broadband pulsed laser radiation. The application of an additional electric-field pulse that rapidly extracts photoions produced by a laser pulse leads to a considerable narrowing of lines of microwave resonances and the Foerster resonance. Various sources of line broadening in cold Rydberg atoms are analyzed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Microwave electrode discharge in nitrogen: Structure and characteristics of the electrode region

The parameters of the electrode region of an electrode microwave discharge in nitrogen are studied by emission spectroscopy. The radial and axial distributions of the intensities of the bands of the second (N{sub 2}(C{sup 3{Pi}}{sub u} {sup {yields}}B{sup 3{Pi}}{sub g})) and first (N{sub 2}(B{sup 3{Pi}}{sub g} {sup {yields}}A{sup 3{Sigma}}{sub u}{sup +})) positive systems of molecular nitrogen and the first negative system of nitrogen ions (N{sub 2}{sup +} (B{sup 2{Sigma}}{sub u}{sup +} {sup {yields}}X{sup 2{Sigma}}{sub g}{sup +})), the radial profiles of the electric field E and the electron density N{sub e}, and the absolute populations of the vibrational levels v{sub C} = 0-4 of the C{sup 3{Pi}}{sub u} excited state of N{sub 2} and the vibrational level v{sub Bi} = 0 of the B{sup 2{Sigma}}{sub u}{sup +} excited state of a molecular nitrogen ion are determined. The population temperature of the first vibrational level T{sub V} of the ground electronic state X{sup 1{Sigma}}{sub g}{sup +} of N{sub 2} and the excitation temperature T{sub C} of the C{sup 3{Pi}}{sub u} state in the electrode region of the discharge are measured. The radius of the spherical region and the spatially integrated plasma emission spectra are studied as functions of the incident microwave power and gas pressure. A method for determining the electron density and the microwave field strength from the plasma emission characteristics is described in detail.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Repetitively rated plasma relativistic microwave oscillator with a controllable frequency in every pulse

A repetitively rated microwave oscillator whose frequency can be varied electronically from pulse to pulse in a predetermined manner is created for the first time. The microwave oscillator has a power on the order of 10{sup 8} W and is based on the Cherenkov interaction of a high-current relativistic electron beam with a plasma preformed before each pulse. Electronic control over the plasma properties allows one to arbitrarily vary the microwave frequency from pulse to pulse at a pulse repetition rate of up to 50 Hz.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Epitaxial synthesis of diamond layers on a monocrystalline diamond substrate in a torch microwave plasmatron

The epitaxial growth of a diamond single-crystal film in a torch microwave discharge excited by a magnetron of a domestic microwave oven with the power of {<=}1 kW in an argon-hydrogen-methane mixture with a high concentration of methane (up to 25% with respect to hydrogen) at atmospheric pressure on a sub-strate of a synthetic diamond single crystal (HPHP) with the orientation (100) and 4 Multiplication-Sign 4 mm in size is obtained. A discharge with the torch diameter of {approx}2 mm and the concentration of the microwave power absorbed in the torch volume of >10{sup 3} W/cm{sup 3} is shown to be effective for epitaxial enlargement of a single crystal of synthetic diamond. The structure of the deposited film with the thickness up to 10 {mu}m with high-quality morphology is investigated with an optical microscope as well as using the methods of the Raman scattering and scanning electron microscopy.

36 MATERIALS SCIENCE↗

The use of a high-current electron beam in plasma relativistic microwave oscillators

Relativistic microwave electronics faces the problem of using high currents of relativistic electron beams; i.e., it is possible to use beams the current of which is lower than that of actually existing high-current accelerators. We show the possibility of increasing the power of radiation generated in a plasma relativistic microwave oscillator (PRMO) due to an increase in the absolute value of current. For the beam currents close to the value of limiting vacuum current, the efficiency of microwave generation decreases; therefore, we study PRMO schemes with a high value of limiting vacuum current, i.e., schemes with a small gap between a hollow relativistic electron beam and the waveguide wall. The results of the experiment and numerical simulation are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pulsed microwave discharges in powder mixtures: Status, problems, and prospects

Results of experiments on the excitation of pulsed microwave discharges by gyrotron radiation (λ = 4 mm, P{sub 0} = 100–500 kW, τ = 1–10 ms) in the volumes and on the surfaces of metal-dielectric powder mixtures are presented. It is shown that there are two phases of discharge development: the spark phase, accompanied by a partial evaporation of the powder material, and the phase of a developed discharge, characterized by a plasma density of ∼10{sup 17} cm{sup –3}, high absorption, and high temperatures (∼5–10 kK) in a thin layer (∼0.1–0.2 mm) of plasma and vapor. It is demonstrated that the conductivity induced in the targets by UV radiation play an important role in the microwave absorption by powder grains. It is found that, in the course of the discharge, a conductive metal mesh forms in the powder volume as a result of metal evaporation. Reactions of high-temperature synthesis were initiated in various powder mixtures (Ti + B, Al + Fe{sub 2}O{sub 3}, Mo + B, etc.). It is shown that the reactions of high-temperature synthesis last for up to 0.1 s and are accompanied by the evaporation of powder grains and the formation of an aerosol cloud due to free expansion of reactants from the sample surface. The possibility of experimentally studying the kinetics of reactions of high-temperature synthesis is demonstrated. It is noticed that microwave discharges can be used to initiate plasmachemical reactions on the surfaces of radioparent materials in active gaseous media.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Propagation and amplification of microwave radiation in a plasma channel created in gas by a high-power femtosecond UV laser pulse

The time evolution of a nonequilibrium plasma channel created in a noble gas by a high-power femtosecond KrF laser pulse is investigated. It is shown that such a channel possesses specific electrodynamic properties and can be used as a waveguide for efficient transportation and amplification of microwave pulses. The propagation of microwave radiation in a plasma waveguide is analyzed by self-consistently solving (i) the Boltzmann kinetic equation for the electron energy distribution function at different spatial points and (ii) the wave equation in the parabolic approximation for a microwave pulse transported along the plasma channel.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Propagation of microwave beams through the stagnation zone in an inhomogeneous plasma

A study is made of the microwave beam evolution due to passing through the stagnation zone, where the group velocity vanishes, thus making the paraxial approximation for the wavefield inappropriate. An extension to the standard beam tracing technique is suggested that allows one to calculate the microwave beam parameters on either branch of its path apart from the stagnation zone, omitting the calculation of the wavefield inside it. Application examples of the extended technique are presented for the case of microwave reflection from the upper hybrid resonance layer in a tokamak plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of microwave treatment on current flow mechanisms in Au-TiB{sub x}-Al-Ti-n{sup +}-n-n{sup +}-GaN-Al{sub 2}O{sub 3} ohmic contacts

The temperature dependences of the contact resistivity {rho}{sub c} of Au-TiB{sub x} Al-Ti-n{sup +}-n-n{sup +}-GaN-Al{sub 2}O{sub 3} ohmic contacts have been studied before and after microwave treatment followed by nine-nonth room-temperature sample storage. The temperature dependences of {rho}{sub c} of initial samples were measured twice. The first measurement showed the temperature dependence typical of ohmic contacts; the repeated measurement in the temperature region above 270 K showed a {rho}{sub c} increase caused by metallic conductivity. After microwave treatment, the metallic conductivity in the ohmic contact is not observed. This is presumably associated with local heating of metal Ga inclusions under microwave irradiation and the formation, due to high chemical activity of liquid gallium, of compounds of it with other metallization components. In this case, the temperature dependence of {rho}{sub c} is controlled by ordinary charge transport mechanisms. After nine-nonth room-temperature storage, the temperature dependence of ?c is described by the tunneling mechanism of charge transport.

36 MATERIALS SCIENCE↗

High-power microwave LDMOS transistors for wireless data transmission technologies (Review)

The fields of the application, structure, fabrication, and packaging technology of high-power microwave LDMOS transistors and the main advantages of these devices were analyzed. Basic physical parameters and some technology factors were matched for optimum device operation. Solid-state microwave electronics has been actively developed for the last 10-15 years. Simultaneously with improvement of old devices, new devices and structures are actively being adopted and developed and new semiconductor materials are being commercialized. Microwave LDMOS technology is in demand in such fields as avionics, civil and military radars, repeaters, base stations of cellular communication systems, television and broadcasting transmitters, and transceivers for high-speed wireless computer networks (promising Wi-Fi and Wi-Max standards).

36 MATERIALS SCIENCE↗

Specific features of the anisotropy of low-temperature microwave magnetoresistivity of lightly doped p-Ge due to the presence of light and heavy holes

The microwave magnetoresistivity of lightly doped (nondegenerate) p-Ge has been studied by the electron spin resonance method. This technique can be employed to record the derivative of the microwave absorption with respect to the magnetic field on the assumption that changes in this absorption are proportional to changes in the conductivity of a semiconductor. At the 10-GHz frequency of the electromagnetic field, the averaging time of the effective masses of light and heavy holes at low temperatures is substantially longer than the oscillation period. This makes it possible to study the individual responses of light and heavy holes to the magnetic field. It is shown that the microwave magnetoabsorption associated with light holes only slightly depends on the direction of the magnetic field relative to the crystallographic axes of Ge. At the same time, the signal related to heavy holes changes by several times when a sample is rotated in a magnetic field. The experimental results are correlated with the theory of the classical magnetoresistive effect.

36 MATERIALS SCIENCE↗