Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MASERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Interstellar OH excitation.

Interstellar SHF radio emission from hydroxyl molecules, discussing maser emission excitation mechanism

Stecher, T. P.↗

An improved atomic hydrogen frequency and time standard

Use of a large bulb, long-multipole magnet, automatic tuner and aluminum cavity provides an improved hydrogen maser which is accurate over long periods of time and suitable for tracking station environments.

Mc Gunigal, T. E.↗

Electrolytic separation of crystals of transition-metal oxides

Versatile flux system grows large, well-formed, stoichiometric single crystals of mixed oxides of the transition-metal elements. These crystals have important uses in the microwave field, and applications as lasers and masers in communications.

Arnott, R. J.↗

Quantum optics or quantum electronics.

Quantum optics or electronics, discussing electromagnetic waves control and interactions with matter, maser oscillators theory and characteristics, nonlinear optics, induced transparency, etc

Townes, C. H.↗

Multiple focusing magnets used for velocity selection of atoms

Computer techniques are used in calculating velocity selection of hydrogen atoms for use in maser frequency standard. Technique permits designer to resolve design problems of multiple focusing magnets employed in atomic velocity selection. There is excellent agreement with hand calculations in constant magnetic moment approximation.

Source record↗

Measurement of the gravitational redshift using a clock in an orbiting satellite

A hydrogen maser clock is proposed for enclosure in an orbiting satellite to measure the gravitational effect on time scales with high accuracy. This experiment is used to test the principle of equivalence for clocks in space. Extremely narrow linewidth of Fe-57 radiation and absorption due to Mossbauer effect over 75 ft vertical distance was used to confirm the prediction of the equivalence principle to 1 part in 100. The fractional frequency shift of a satellite-borne oscillator observed from earth is also given.

Vessot, R. F. C.↗

Rubidium gas cell studies

The stability of Rb-87 optically pumped masers and Rb gas cells is examined. Descriptions are given of the technical procedures used in construction and the changes made to solve the problems encountered in the electronics of the systems.

Vanier, J.↗

Spaceborne clock system: Some alternatives for a proposed NASA experiment

A spaceborne clock experiment is proposed with the objectives of improving international time and frequency comparisons, studying precise one-way Doppler tracking and one-way ranging techniques, performing relativistic studies, and developing new atomic frequency standards technology. Various alternatives are considered for accomplishing these goals, including the use of existing satellite and earth-based time dissemination systems as well as the development of a new frequency standard for this specific application. One conclusion is that several attractive alternatives already exist for meeting the goal of improved time and frequency dissemination. However, to achieve all the other 4 goals at the NASA-stated levels of accuracy, a spaceborne atomic frequency standard may be required. An analysis of achievements to date with quartz oscillators, rubidium standards, cesium beam standards, hydrogen masers, and several other possibilities leads to the conclusion that cesium and rubidium standards offer the best choices for the experiment as proposed by NASA. The greatest obstacle to a spaceborne atomic standard appears to be its electrical power requirements.

Beehler, R. E.↗

Hydrogen as an atomic beam standard

After a preliminary discussion of feasibility, new experimental work with a hydrogen beam is described. A space focused magnetic resonance technique with separated oscillatory fields is used with a monochromatic beam of cold hydrogen atoms which are selected from a higher temperature source. The first resonance curves and other experimental results are presented. These results are interpreted from the point of view of accuracy potential and frequency stability, and are compared with hydrogen maser and cesium beam capabilities.

Peters, H. E.↗

Infrared observations of 1612 MHz IR/OH sources.

IR spectra and photometry are given for several IR objects which are known to have 1612 MHz OH emission. These IR/OH sources are shown to be either M type Mira variables or M supergiants with photospheric temperatures around 2000 K. All those examined are oxygen rich and none are carbon stars which suggests a high abundance of OH in their photospheres. A significant fraction of the total luminosity is emitted in the IR beyond 3.5 microns which is taken to imply a dust shell structure around the central star. There is no evidence which uniquely requires that IR pumping of the OH maser is taking place; there are, however, generally enough near infrared photons to supply the observed microwave energy.

Hyland, A. R.↗