High-precision evaluation of the magnetic moment of the helion

NMR spectra of samples containing a mixture of hydrogen deuteride HD with pressure of about 80 atm and helium-3 with partial pressure of about 1 atm are analyzed. The ratio of the resonance frequencies of the nuclei, F({sup 3}He)/F(H{sub 2}), is determined to be 0.761786594(2), which is equal to the magnetic moment of the helion (bound in a helium atom) in the units of the magnetic moment of a proton (bound in molecular hydrogen). The uncertainty of two digits in the last place corresponds to a relative error of {delta}[F({sup 3}He)/F(H{sub 2})] = 2.6 Multiplication-Sign 10{sup -9}. The use of the known calculated data on the shielding of nuclei in the helium-3 atom ({sigma}({sup 3}He) = 59924(2) Multiplication-Sign 10{sup -9}) and on the shielding of protons in hydrogen ({sigma}(H{sub 2}) = 26288(2) Multiplication-Sign 10{sup -9}) yields a value of {mu}({sup 3}He)/{mu}{sub p} = -0.761812217(3) for the free magnetic moment of the helion in the units of the proton magnetic moment.

74 ATOMIC AND MOLECULAR PHYSICS↗

Applying Analog Integrated Circuits for Hero Protection

One of the most efficient methods for protecting electro-explosive devices (EED's) from HERO and ESD is to shield the EED in a conducting shell (Faraday cage). Electrical energy is transferred to the bridge by means of a magnetic coupling which passes through a portion of the conducting shell that is made from a magnetically permeable but electrically conducting material. This technique was perfected by ML Aviation, a U.K. company, in the early 80's, and was called a Radio Frequency Attenuation Connector (RFAC). It is now in wide use in the U.K. Previously, the disadvantage of RFAC over more conventional methods was its relatively high cost, largely driven by a thick film hybrid circuit used to switch the primary of the transformer. Recently, through a licensing agreement, this technology has been transferred to the U.S. and significant cost reductions and performance improvements have been achieved by the introduction of analog integrated circuits. An integrated circuit performs the following functions: (1) Chops the DC input to a signal suitable for driving the primary of the transformer; (2) Verifies the input voltage is above a threshold; (3) Verifies the input voltage is valid for a pre set time before enabling the device; (4) Provides thermal protection of the circuit; and (5) Provides an external input for independent logic level enabling of the power transfer mechanism. This paper describes the new RFAC product and its applications.

Kenneth E Willis↗

Functional Janus structured liquids and aerogels

Janus structures have unique properties due to their distinct functionalities on opposing faces, but have yet to be realized with flowing liquids. We demonstrate such Janus liquids with a customizable distribution of nanoparticles (NPs) throughout their structures by joining two aqueous streams of NP dispersions in an apolar liquid. Using this anisotropic integration platform, different magnetic, conductive, or non-responsive NPs can be spatially confined to opposite sides of the original interface using magnetic graphene oxide (mGO)/GO, Ti 3 C 2 T x /GO, or GO suspensions. The resultant Janus liquids can be used as templates for versatile, responsive, and mechanically robust aerogels suitable for piezoresistive sensing, human motion monitoring, and electromagnetic interference (EMI) shielding with a tuned absorption mechanism. The EMI shields outperform their current counterparts in terms of wave absorption, i.e., SE T ≈ 51 dB, SE R ≈ 0.4 dB, and A = 0.91, due to their high porosity ranging from micro- to macro-scales along with non-interfering magnetic and conductive networks imparted by the Janus architecture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Verification of the Prompt Radiation Shielding Design of the ESS Accelerator

Fermilab will perform prompt radiation and shielding verification studies for the European Spallation Source ERIC (ESS) accelerator tunnel and existing penetration layouts using the latest information on the beam line and existing models of magnets and cryomodules. The input information about the assumptions, geometry layout, etc. will be provided by the Safety Group (accelerator division, ESS). The MEDT department of the Accelerator Division, Fermilab will provide the results of the studies. MARS15, a Fermilab a multi-purpose Monte-Carlo code developed since 1974, is at the heart of this effort. MARS15 is used for detailed simulation of hadronic and electromagnetic cascades in an arbitrary 3-D geometry of shielding, accelerator, detector and spacecraft components with energy ranging from a fraction of an electronvolt to 100 TeV. This work will provide additional validation of recent additions to the physical models in the code, including the code capabilities to simulate cascades and generate a variety of results in complex media.

43 PARTICLE ACCELERATORS↗

A portable cryostat for the cold transfer of polarized solid HD targets: HDice-I

We developed a device with moveable liquid nitrogen and liquid helium volumes that is capable of reaching over 2 m into the coldest regions of a cryostat or dilution refrigerator and reliably extracting or installing a target of solid, polarized hydrogen deuteride (HD). This Transfer Cryostat incorporates a cylindrical neodymium rare-earth magnet that is configured as a Halbach dipole, which is maintained at 77 K and produces a 0.1 T field around the HD target. Multiple layers provide a hermetic 77 K-shield as the device is used to maintain a target at 2 K during a transfer between cryostats. Our tests with frozen-spin HD show very little polarization loss for either H (-1±2%, relative) or D (0±3%, relative) over typical transfer periods. Multiple target transfers with this apparatus have shown an overall reliability of about 95% per transfer, which is a significant improvement over earlier versions of the device.

42 ENGINEERING↗

Indirect Magnetic Measurements on the Aerodynamic Heating Facility (AHF)

The arc jet complex at NASA Ames Research Center (ARC) investigates various thermal protection systems (TPS) and their performance in high enthalpy flow environments to improve heat shields used in atmospheric entry. The arc jet operates by inducing an arc between two electrodes and passing the heated gas through a supersonic nozzle. The arc plasma is typically a partially ionized air mixture at low temperature (< 2 eV) but operates for long periods of time (up to 30 min) at high power (< 60 MW). However, simulations using the in-house ARC Heater Simulator (ARCHeS) code predict that the arc is still unstable to MHD instabilities, primarily the kink instability, which limit the operational envelope of the facility [1]. Consequently, it is important to better characterize these instabilities to improve facility stability and extend operational ranges. Due to the high enthalpy and long timescales (i.e., minutes) arc diagnostics must be non-invasive (i.e., optical or magnetic). This work will cover the development of tri-axial magnetic hall sensors for arc jet instabilities and subsequent 3D characterization of arc motion. The latest results describing the kink instability amplitude, frequency and wavelength will be presented and represent the first measurements of this instability in a NASA arc jet facility. References: [1] Meurisse, J. (2018). 3D Unsteady Model of Arc Heater Plasma Flow Using the ARC Heater Simulator (ARCHeS), APS Gaseous Electronics Conference, 2018: APS.

Sebastian Vicente Colom↗

OPTICAL SPECTRAL VARIABILITY OF THE VERY HIGH ENERGY GAMMA-RAY BLAZAR 1ES 1011+496

We present results of five years of optical (UBVRI) observations of the very high energy gamma-ray blazar 1ES 1011+496 at the MDM Observatory. We calibrated UBVRI magnitudes of five comparison stars in the field of the object. Most of our observations were done during moderately faint states of 1ES 1011+496 with R {approx}> 15.0. The light curves exhibit moderate, closely correlated variability in all optical wavebands on timescales of a few days. A cross-correlation analysis between optical bands does not show significant evidence for time lags. We find a positive correlation (Pearson's r = 0.57; probability of non-correlation P(>r) {approx} 4 x 10{sup -8}) between the R-band magnitude and the B-R color index, indicating a bluer-when-brighter trend. Snapshot optical spectral energy distributions exhibit a peak within the optical regime, typically between the V and B bands. We find a strong (r = 0.78; probability of non-correlation P(>r) {approx} 10{sup -15}) positive correlation between the {nu}F{sub {nu}} peak flux and the peak frequency, best fit by a relation {nu}F {sup pk}{sub {nu} {proportional_to}} {nu} {sup k}{sub pk} with k = 2.05 {+-} 0.17. Such a correlation is consistent with the optical (synchrotron) variability of 1ES 1011+496 being primarily driven by changes in the magnetic field.

79 ASTRONOMY AND ASTROPHYSICS↗

Debye screening and injection of positrons across the magnetic surfaces of a pure electron plasma in a stellarator

Just as quasineutral plasmas, pure electron plasmas display collective behavior and screen externally imposed electrostatic potentials. However, for pure electron plasmas, the screening of large negative potentials is fully nonlinear and deviates significantly from the textbook Debye screening. Such potentials create an evacuated region that may penetrate a long distance away from the source of the potential perturbation. An analytic model for this case is presented and compared to numerical solutions of the pure electron plasma equilibrium equation in a stellarator. Debye screening in non-neutral plasmas is asymmetric; in a pure electron plasma, negative potentials are not screened as effectively as positive potentials. Because external potentials can penetrate deep into the plasma, they can have a strong effect on particle orbit quality. Importantly, the assessment of transport driven by internal objects, e.g., diagnostic rods, depends on this. Numerical calculations are presented, showing that the poor shielding of negative potentials can be used not only to perturb and worsen confinement of a pure electron plasma, but can also be used to improve confinement modestly and can be used for injection of positrons across the magnetic surfaces in an initially pure electron plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-400: Evaluation of Shielding and Activation at Two Pencil Beam Scanning Proton Facilities

Purpose: To verify acceptably low dose levels around two newly constructed identical pencil beam scanning proton therapy facilities and to evaluate accuracy of pre-construction shielding calculations. Methods: Dose measurements were taken at select points of interest using a WENDI-2 style wide-energy neutron detector. Measurements were compared to pre-construction shielding calculations. Radiation badges with neutron dose measurement capabilities were worn by personnel and also placed at points throughout the facilities. Seven neutron and gamma detectors were permanently installed throughout the facility, continuously logging data. Potential activation hazards have also been investigated. Dose rates near water tanks immediately after prolonged irradiation have been measured. Equipment inside the treatment room and accelerator vault has been surveyed and/or wipe tested. Air filters from air handling units, sticky mats placed outside of the accelerator vault, and water samples from the magnet cooling water loops have also been tested. Results: All radiation badges have been returned with readings below the reporting minimum. Measurements of mats, air filters, cooling water, wipe tests and surveys of equipment that has not been placed in the beam have all come back at background levels. All survey measurements show the analytical shielding calculations to be conservative by at least a factor of 2. No anomalous events have been identified by the building radiation monitoring system. Measurements of dose rates close to scanning water tanks have shown dose rates of approximately 10 mrem/hr with a half-life less than 5 minutes. Measurements around the accelerator show some areas with dose rates slightly higher than 10 mrem/hr. Conclusion: The shielding design is shown to be adequate. Measured dose rates are below those predicted by shielding calculations. Activation hazards are minimal except in certain very well defined areas within the accelerator vault and for objects placed directly in the path of the beam.

60 APPLIED LIFE SCIENCES↗

Prediction of LDEF ionizing radiation environment

The Long Duration Exposure Facility (LDEF) spacecraft flew in a 28.5 deg inclination circular orbit with an altitude in the range from 172 to 258.5 nautical miles. For this orbital altitude and inclination two components contribute most of the penetrating charge particle radiation encountered - the galactic cosmic rays and the geomagnetically trapped Van Allen protons. Where shielding is less than 1.0 g/sq cm geomagnetically trapped electrons make a significant contribution. The 'Vette' models together with the associated magnetic filed models were used to obtain the trapped electron and proton fluences. The mission proton doses were obtained from the fluence using the Burrell proton dose program. For the electron and bremsstrahlung dose we used the Marshall Space Flight Center (MSFC) electron dose program. The predicted doses were in general agreement with those measured with on-board thermoluminescent detector (TLD) dosimeters. The NRL package of programs, Cosmic Ray Effects on MicroElectronics (CREME), was used to calculate the linear energy transfer (LET) spectrum due to galactic cosmic rays (GCR) and trapped protons for comparison with LDEF measurements.

Watts, John W.↗

Revised prediction of LDEF exposure to trapped protons

The Long Duration Exposure Facility (LDEF) spacecraft flew in a 28.5 deg inclination circular orbit with an altitude in the range from 319.4 to 478.7 km. For this orbital altitude and inclination, two components contribute most of the penetrating charge particle radiation encountered - the galactic cosmic rays and the geomagnetically trapped Van Allen protons. Where shielding is less than 1.0 g/sq cm geomagnetically trapped electrons make a significant contribution. The 'Vette' models together with the associated magnetic field models and the solar conditions were used to obtain the trapped electron and proton omnidirectional fluences reported previously. Results for directional proton spectra using the MSFC anisotropy model for solar minimum and 463 km altitude (representative for the LDEF mission) were also reported. The directional trapped proton flux as a function of mission time is presented considering altitude and solar activity variation during the mission. These additional results represent an extension of previous calculations to provide a more definitive description of the LDEF trapped proton exposure.

Watts, John W.↗

High-Energy Space Propulsion Based on Magnetized Target Fusion

Magnetized target fusion is an approach in which a magnetized target plasma is compressed inertially by an imploding material wall. A high energy plasma liner may be used to produce the required implosion. The plasma liner is formed by the merging of a number of high momentum plasma jets converging towards the center of a sphere where two compact toroids have been introduced. Preliminary 3-D hydrodynamics modeling results using the SPHINX code of Los Alamos National Laboratory have been very encouraging and confirm earlier theoretical expectations. The concept appears ready for experimental exploration and plans for doing so are being pursued. In this talk, we explore conceptually how this innovative fusion approach could be packaged for space propulsion for interplanetary travel. We discuss the generally generic components of a baseline propulsion concept including the fusion engine, high velocity plasma accelerators, generators of compact toroids using conical theta pinches, magnetic nozzle, neutron absorption blanket, tritium reprocessing system, shock absorber, magnetohydrodynamic generator, capacitor pulsed power system, thermal management system, and micrometeorite shields.

Thio, Y. C. F.↗

Parametrial Boost Using Midline Shielding Results in an Unpredictable Dose to Tumor and Organs at Risk in Combined External Beam Radiotherapy and Brachytherapy for Locally Advanced Cervical Cancer

Purpose: Midline-blocked boost (MBB) fields are frequently used in the treatment of locally advanced cervical cancer. The purpose of this study was to evaluate the dose contribution from MBBs to tumor and organs at risk. Methods and Materials: Six patients with locally advanced cervical cancer (IIB-IIIB) treated with definitive chemoradiotherapy and magnetic resonance imaging (MRI)-guided brachytherapy were analyzed. A three-phase plan was modeled: 45 Gy (1.8 Gy per fraction) four-field box, 9 Gy (1.8 Gy per fraction) MBB (midline-shielded anteroposterior/posteroanterior fields), and intracavitary MRI-guided brachytherapy boost of 28 Gy (7 Gy per fraction). Midline shields 3, 4, and 5 cm wide were simulated for each patient. Brachytherapy and MBB plans were volumetrically summed. The rectum, sigmoid, and bladder minimum dose in the most exposed 2 cm{sup 3} of an organ at risk (D{sub 2cc}) and high-risk clinical target volume (HR-CTV) and intermediate-risk clinical target volume (IR-CTV) D90 and D100 were evaluated. The intended HR-CTV D90 was 85 Gy or greater, and the intended IR-CTV D90 was greater than 60 Gy. Results: After a 4-cm MBB, HR-CTV D90 remained lower than 85 Gy in all cases (mean, 74 Gy; range, 64-82 Gy). High-risk clinical target volume (85 Gy) coverage increased slightly from 73% (range, 64-82%) to 78% (range, 69-88%). Mean IR-CTV D90 increased from 56 Gy (range, 53-64 Gy) to 62 Gy (range, 59-67 Gy). Intermediate-risk clinical target volume 60-Gy dose coverage increased from 81% (range, 72-96%) to 96% (range, 90-100%). The mean volume irradiated to 85 Gy increased by 14 cm{sup 3} (range, 10-22 cm{sup 3}), whereas the volume irradiated to 60 Gy increased from 276 cm{sup 3} (range, 185-417 cm{sup 3}) to 592 cm{sup 3} (range, 385-807 cm{sup 3}). Bladder, rectum, or sigmoid D{sub 2cc} increased by more than 50% of the boost dose in 4 of 6 patients. Conclusions: Midline-blocked boosts contribute substantial dose to rectum, sigmoid, and bladder D{sub 2cc}. HR-CTV dose and 85-Gy coverage remain compromised in large tumors despite MBB. IR-CTV 60-Gy coverage improved at the expense of a considerable increase in volume of normal tissue irradiated to 60 Gy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electronic Structure, Elastic, Magnetic, and Optical Properties of Fe{sub 2}MnZ (Z = Si, Ge, and Sn) Full Heusler Alloys: First-Principle Calculations

Investigations of the electronic structure, elastic, magnetic, and optical properties of Fe{sub 2}MnZ (Z = Si, Ge, and Sn) full Heusler alloys show mechanical stability with cubic symmetry in all three alloys. They are elastically anisotropic and Fe{sub 2}MnSi is ductile whereas Fe{sub 2}MnGe and Fe{sub 2}MnSn are brittle in nature. The value of total magnetic moment is 3 μ{sub B} for Fe{sub 2}MnSi and Fe{sub 2}MnGe at their equilibrium lattice constants and follows the Slater–Pauling curve. Fe{sub 2}MnSn possess the largest magnetic moment among the three with a value of 5.73 μ{sub B} at equilibrium lattice constant. Fe{sub 2}MnSi shows half-metallic nature with 100% spin polarization for a wide range of lattice parameters and is useful for spintronics devices. Good optical properties over wide photon energies point to the possible use of these alloys as radiation shielding materials, optical filters, and photo-electronic devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Superconductor-Mediated Modification of Gravity? AC Motor Experiments with Bulk YBCO Disks in Rotating Magnetic Fields

We have previously reported results using a high precision gravimeter to probe local gravity changes in the neighborhood of large bulk-processed high-temperature superconductors. Podkietnov, et al (Podkietnov, E. and Nieminen, R. (1992) A Possibility of Gravitational Force Shielding by Bulk YBa2 Cu3 O7-x Superconductor, Physica C, C203:441-444.) have indicated that rotating AC fields play an essential role in their observed distortion of combined gravity and barometric pressure readings. We report experiments on large (15 cm diameter) bulk YBCO ceramic superconductors placed in the core of a three-phase, AC motor stator. The applied rotating field produces up to a 12,000 revolutions per minute magnetic field. The field intensity decays rapidly from the maximum at the outer diameter of the superconducting disk (less than 60 Gauss) to the center (less than 10 Gauss). This configuration was applied with and without a permanent DC magnetic field levitating the superconducting disk, with corresponding gravity readings indicating an apparent increase in observed gravity of less than 1 x 10(exp -6)/sq cm, measured above the superconductor. No effect of the rotating magnetic field or thermal environment on the gravimeter readings or on rotating the superconducting disk was noted within the high precision of the observation. Implications for propulsion initiatives and power storage flywheel technologies for high temperature superconductors will be discussed for various spacecraft and satellite applications.

Noever, David A.↗

Validation of on- and off-axis neutral beam current drive against experiment in DIII-D

Neutral beam current drive (NBCD) experiments in DIII-D using vertically shifted plasmas to move the current drive away from the axis have clearly demonstrated robust off-axis NBCD. Time-dependent measurements of magnetic field pitch angles by the motional Stark effect diagnostic are used to obtain the evolution of the poloidal magnetic flux, which indicates a broad off-axis NBCD profile with a peak at about half the plasma minor radius. In most cases, the measured off-axis NBCD profile is consistent with calculations using an orbit-following Monte Carlo code for the beam ion slowing down including finite-orbit effects provided there is no large-scale magnetohydrodynamic activity such as Alfven eigenmodes modes or sawteeth. An alternative analysis method shows good agreement between the measured pitch angles and those from simulations using transport-equilibrium codes. Two-dimensional image of Doppler-shifted fast ion D{sub {alpha}} light emitted by neutralized energetic ions shows clear evidence for a hollow profile of beam ion density, consistent with classical beam ion slowing down. The magnitude of off-axis NBCD is sensitive to the alignment of the beam injection relative to the helical pitch of the magnetic field lines. If the signs of toroidal magnetic field and plasma current yield the proper helicity, both measurement and calculation indicate that the efficiency is as good as on-axis NBCD because the increased fraction of trapped electrons reduces the electron shielding of the injected ion current, in contrast with electron current drive schemes where the trapping of electrons degrades the efficiency. The measured off-axis NBCD increases approximately linearly with the injection power, although a modest amount of fast ion diffusion is needed to explain an observed difference in the NBCD profile between the measurement and the calculation at high injection power.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

NASA Tech Briefs, July 2003

Topics covered include: Real-Time, High-Frequency QRS Electrocardiograph; Software for Improved Extraction of Data From Tape Storage; Radio System for Locating Emergency Workers; Software for Displaying High-Frequency Test Data; Capacitor-Chain Successive-Approximation ADC; Simpler Alternative to an Optimum FQPSK-B Viterbi Receiver; Multilayer Patch Antenna Surrounded by a Metallic Wall; Software To Secure Distributed Propulsion Simulations; Explicit Pore Pressure Material Model in Carbon-Cloth Phenolic; Meshed-Pumpkin Super-Pressure Balloon Design; Corrosion Inhibitors as Penetrant Dyes for Radiography; Transparent Metal-Salt-Filled Polymeric Radiation Shields; Lightweight Energy Absorbers for Blast Containers; Brush-Wheel Samplers for Planetary Exploration; Dry Process for Making Polyimide/ Carbon-and-Boron-Fiber Tape; Relatively Inexpensive Rapid Prototyping of Small Parts; Magnetic Field Would Reduce Electron Backstreaming in Ion Thrusters; Alternative Electrochemical Systems for Ozonation of Water; Interferometer for Measuring Displacement to Within 20 pm; UV-Enhanced IR Raman System for Identifying Biohazards; Prognostics Methodology for Complex Systems; Algorithms for Haptic Rendering of 3D Objects; Modeling and Control of Aerothermoelastic Effects; Processing Digital Imagery to Enhance Perceptions of Realism; Analysis of Designs of Space Laboratories; Shields for Enhanced Protection Against High-Speed Debris; Study of Dislocation-Ordered In(x)Ga(1-x)As/GaAs Quantum Dots; and Tilt-Sensitivity Analysis for Space Telescopes.

Source record↗

Space Flight Qualification Program for the AMS-2 Commercial Cryocoolers

The Alpha Magnetic Spectrometer-02 (AMS-02) experiment is a state-of-the-art particle physics detector containing a large superfluid helium-cooled superconducting magnet. Highly sensitive detector plates inside the magnet measure a particle's speed, momentum, charge, and path. The AMS-02 experiment will study the properties and origin of cosmic particles and nuclei including antimatter and dark matter. AMS-02 will be installed on the International Space Station on Utilization Flight-4. The experiment will be run for at least three years. To extend the life of the stored cryogen and minimize temperature gradients around the magnet, four Stirling-cycle Sunpower M87N cryocoolers will be integrated with AMS-02. The cryocooler cold tip will be connected via a flexible strap to the outer vapor cooled shield of the dewar. Initial thermal analysis shows the lifetime of the experiment is increased by a factor of 2.8 with the use of the cryocooler. The AMS-02 project selected the Sunpower M87 cryocoolers and has asked NASA Goddard to qualify the cryocoolers for space flight use. This paper describes the interfaces with the cryocoolers and presents data collected during testing of the two engineering model cryocoolers. Tests include thermal performance characterization and launch vibration testing. Magnetic field compatibility testing will be presented in a separate paper at the conference.