Stability of polymeric separators in lithium metal batteries in a low voltage environment
Separators can largely affect the coulombic efficiency and cycling stability of lithium metal anode, especially when using the LiPF 6 electrolyte.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Separators can largely affect the coulombic efficiency and cycling stability of lithium metal anode, especially when using the LiPF 6 electrolyte.
Bioinspired nickel phosphide electrocatalysts achieve breakthrough efficiency and selectivity for C 3 and C 4 products.
A new solution-based synthesis method to produce a high quality Li 2 S–P 2 S 5 solid electrolyte was developed by using a strong nucleophile of LiC 2 H 5 .
Phase diagram in the Na x MoO 2 system ( x ≤ 0.5) determined using electrochemistry and in situ X-ray powder diffraction.
Synthesis, electronic structure, and reactivity of a novel Co( ii ) carbene radical in the bis(alkoxide) ligand environment are reported.
Abstract not provided
High-pressure structural studies of claudetite I reveal that it exhibits the lowest As coordination numbers despite being the densest As 2 O 3 polymorph.
A facile, scalable, wastewater-free synthesis of high energy density LiMn0.5Fe0.5PO4 (LMFP) cathodes with high electrode press density is achieved by employing the spinel LiMnFeO4 (LMFO) as a precursor.
We report the Li+d reaction with liquid Li target and the D+D reaction in liquid Li with ultrasonic cavitation. The screening potential of the Li+d reaction has been deduce from the thick target yields of alpha particles emitted in the {sup 6}Li(d,alpha){sup 4} He reaction in the solid and liquid phase. The deduced screening potential for the liquid Li is about 180 eV larger than for the solid. This difference is considered to attributed to the effect of liquefied Li{sup +} ions. It is found out that the D+D reaction in liquid Li with ultrasonic cavitation is enhanced very much; the enhancement corresponds to effective energy increase of about 2000 eV.
Charge transfer (CT) in molecular ion-neutral interactions can proceed through dynamically coupled electronic, vibrational, and rotational degrees of freedom. Using the upgraded Oak Ridge National Laboratory ion-atom merged-beams apparatus, absolute direct charge transfer is explored from keV/u collision energies where the collision is considered ''ro-vibrationally frozen'' to sub-eV/u collision energies where collision times are long enough to sample vibrational and rotational modes. Our first molecular ion measurement with the merged-beams apparatus has been performed for D{sub 2}{sup +}+H and is used to benchmark high energy sudden approximation theory and vibrational specific adiabatic theory for the (H{sub 2}-H){sup +} complex. CT measurements have also been performed for D{sub 3}{sup +}+H from 2 eV/u to 2 keV/u and CO{sup +}+D from 20 eV/u to 2000 eV/u. With straightforward improvements to the apparatus, we plan to extend our measurements to key ''destructive'' rate coefficients for H{sub 2}{sup +} and CH{sup +} with H at temperatures relevant to the interstellar medium.
Thomas Jefferson National Accelerator Facility (Jefferson Lab) has become one of the premier facilities for the study of nucleon spin structure. Over the past two decades, several high precision measurements of the polarized structure functions g1(x,Q{sup 2}) and g2(x,Q{sup 2}) have been performed that have extensively covered the region between 0.02 and 5 GeV{sup 2}. Spin moments have been formed from the measured structure functions. These proceedings will concentrate on experiment E97-110, which was performed in Hall A to study the neutron and {sup 3}He spin structure at four-momentum transfers squared (Q{sup 2}) = 0.02 - 0.26 GeV{sup 2}. This range allows us to make a benchmark-check of Chiral Perturbation Theory calculations. Previous results for the neutron spin polarizability, {delta}LT , down to 0.1 GeV{sup 2} have shown significant disagreement with the calculations. Preliminary results on the generalized spin polarizabilities, {gamma}0 and {delta}LT , for the neutron were presented at the conference and will be discussed here.
Fast wave electron heating experiments are carried out on Aditya tokamak [R = 0.75 m, a = 0.25m,Bt = 0.75T,ne{approx}1-3E13/cc,Te{approx}250eV] with the help of indigenously developed 200 kW, 20-40 MHz RF heating system. Significant direct electron heating is observed by fast waves in hydrogen plasma with prompt rise in electron temperature with application of RF power and it increases linearly with RF power. A corresponding increase in plasma beta and hence increase in stored diamagnetic energy is also observed in presence of RF. We observe an improvement of energy confinement time from 2-4msec during ohmic heating phase to 3-6msec in RF heating phase. This improvement is within the ohmic confinement regime for the present experiments. The impurity radiation and electron density do not escalate significantly with RF power. The direct electron heating by fast wave in Aditya is also predicted by ion cyclotron resonance heating code TORIC.
For an experiment to study neutron radiative beta-decay, we operated large area avalanche photodiodes (APDs) near liquid nitrogen temperature to detect x rays with energies between 0.2 keV and 20 keV. Whereas there are numerous reports of x ray spectrometry using APDs at energies above 1 keV, operation near liquid nitrogen temperature allowed us to reach a nominal threshold of 0.1 keV. However, due to the short penetration depth of x rays below 1 keV, the pulse height spectrum of the APD become complex. We studied the response using monochromatic x ray beams and employed phenomenological fits of the pulse height spectrum to model the measurement of a continuum spectrum from a synchrotron. In addition, the measured pulse height spectrum was modelled using a profile for the variation in efficiency of collection of photoelectrons with depth into the APD. The best results are obtained with the collection efficiency model.
Explore the source record for details and available documents.
Precise measurement of transverse phase space of a high-brightness electron beamis of fundamental importance in modern accelerators and free-electron lasers. Often, the transverse phase space of a high-brightness, space-charge-dominated electron beam is measured using a multi-slit method. In this method, a transverse mask (slit/pepperpot) samples the beaminto a set of beamlets, which are then analyzed on to a screen downstream. The resolution in this method is limited by the type of screen used which is typically around 20 {mu}m for a high-sensitivity Yttrium Aluminum Garnet screen. Accurate measurement of sub-micron transverse emittance using this method would require a long drift space between the multi-slit mask and observation screen. In this paper, we explore a variation of the technique that incorporates quadrupole magnets between the multi-slit mask and the screen. It is shown that this arrangement can improve the resolution of the transverse-phase-space measurement with in a short footprint.
N/A
Energetic and geometric aspects of the permeation of the atoms hydrogen to neon neutral atoms through graphene sheets are investigated by investigating the associated energy barriers and sheet deformations. Density functional theory calculations on cluster models, where graphene is modeled by planar polycyclic aromatic hydrocarbons (PAHs), provide the energies and geometries. Particularities of our systems, such as convergence of both energy barriers and deformation curves with increasing size of the PAHs, are discussed. Three different interaction regimes, adiabatic, planar and vertical, are investigated by enforcing different geometrical constraints. The adiabatic energy barriers range from 5 eV for hydrogen to 20 eV for neon. We find that the permeation of oxygen and carbon into graphene is facilitated by temporary chemical bonding while for other, in principle reactive atoms, it is not. We discuss implications of our results for modeling chemical sputtering of graphite.