Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Level Of Conservation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Thermal analysis for ion-exchange column system

Models have been developed to simulate the thermal characteristics of Crystalline Silico-titanate (CST) ion exchange media fully loaded with radioactive cesium in a column configuration and distributed within a waste storage tank. This work was conducted to support the Small Column Ion Exchange (SCIX) program which is focused on processing dissolved, high-sodium salt waste for the removal of specific radionuclides (including Cs-137, Sr-90, and actinides) within a High Level Waste (HLW) storage tank at the Savannah River Site. A two-dimensional computational modeling approach for the in-column ion-exchange domain was taken to include conservative, bounding estimates for key parameters such that the results would provide the maximum centerline temperatures achievable under the design configurations using a feed composition known to promote high cesium loading on CST. A primary objective of these calculations was to estimate temperature distributions across packed CST beds immersed in waste supernate or filled with dry air under various accident scenarios. Accident scenarios evaluated included loss of salt solution flow through the bed, inadvertent column drainage, and loss of active cooling in the column. The modeling results demonstrate that the baseline design using one central and four outer cooling tubes provides a highly efficient cooling mechanism for reducing the maximum column temperature. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Zero Liquid Discharge and Water Reuse in Recirculating Cooling Towers at Power Facilities: Review and Case Study Analysis

Zero liquid discharge (ZLD) systems installed at power facilities with the primary purpose of meeting water discharge regulations have the added benefit of providing high quality effluent that can be reused in the facility. This paper provides a review of water use in power sector recirculating cooling towers and a baseline assessment of on-site water reuse at natural gas combined cycle (NGCC) power facilities. Two NGCC facilities with reverse-osmosis (RO) or brine-concentrator processes followed by evaporation ponds were selected as case studies; data from these facilities were used to quantify the water, energy, and cost implications of implementing conventional and emerging ZLD technologies. At one case study facility, model results show that implementation of ZLD would reduce water withdrawals by 18%, which is less than savings associated with implementation of dry cooling but comparable to current efforts to reduce water withdrawals by increasing cycles of concentration. Implementation of ZLD using high-recovery RO resulted in a doubling of the levelized cost of water (LCOW). LCOW increased more when a brine concentrator was used. For both case studies, the ZLD system using high-recovery RO required less than 0.1% of a facilitiy's annual electricity generation and the ZLD system using a brine concentrator process required less than 0.8%. Additionally, increasing the evaporation pond area to minimize required ZLD system recovery rates and reduce system electricity costs does not reduce the LCOW. Instead, the LCOW increases because less water is recovered and more water is lost to evaporation. Furthermore, if water availability decreases or water competition/cost increases, facilities may be incentivized to maximize water recovery from ZLD systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Examining the self-interaction of dark matter through central cluster galaxy offsets

ABSTRACT While collisionless cold dark matter models have been largely successful in explaining a wide range of observational data, some tensions still exist, and it remains possible that dark matter possesses a non-negligible level of self-interactions. In this paper, we investigate a possible observable consequence of self-interacting dark matter: offsets between the central galaxy and the centre of mass of its parent halo. We examine 23 relaxed galaxy clusters in a redshift range of 0.1–0.3 drawn from clusters in the Dark Energy Survey and the Sloan Digital Sky Survey which have archival Chandra X-ray data of sufficient depth for centre and relaxation determination. We find that most clusters in our sample show non-zero offsets between the X-ray centre, taken to be the centroid within the cluster core, and the central galaxy position. All of the measured offsets are larger, typically by an order of magnitude, than the uncertainty in the X-ray position due to Poisson noise. In all but six clusters, the measured offsets are also larger than the estimated, combined astrometric uncertainties in the X-ray and optical positions. A more conservative cut on concentration to select relaxed clusters marginally reduces but does not eliminate the observed offset. With our more conservative sample, we find an estimated median X-ray to central galaxy offset of $\mu = 6.0 ^{+ 1.4}_{- 1.5}$ kpc. Comparing to recent simulations, this distribution of offsets is consistent with some level of dark matter self-interaction, though further simulation work is needed to place constraints.

79 ASTRONOMY AND ASTROPHYSICS↗

The transition from resistance to acceptance: Managing a marine invasive species in a changing world

Abstract Marine invasive species can transform coastal ecosystems, yet mitigating their effects can be difficult, and even impractical. Often, marine invasive species are managed at poorly matched spatial scales, and at the same time, rates of spread and establishment are increasing under climate change and can outpace resources available for population suppression. These circumstances challenge traditional conservation goals of maintaining a historic environmental state, especially for a species like the European green crab ( Carcinus maenas ), a formidable invader with few examples of successful long‐term removal programs. A management paradigm where decision alternatives include resisting or accepting a new ecological trajectory may be needed. We apply mathematical concepts from decision theory to develop a quantitative framework for navigating management decisions in this new resist‐accept paradigm. We develop a model of European green crab growth, removal and colonization, and we find optimal levels of removal effort that minimize both ecological change and removal cost. We establish a benchmark of colonization pressure at which green crab density becomes decoupled from a decision maker's actions, such that population control can no longer shape the invasion trajectory. For informing the decision boundary between resistance and acceptance, our results highlight that a decision maker's understanding of how removal cost scales with removal effort is more important than understanding the density‐impact relationship. We show that assuming stationary system dynamics can result in sub‐optimal levels of species removal effort, highlighting the importance of developing anticipatory management strategies by accounting for non‐stationary dynamics. Policy implications . For marine invasive species that can disperse across long distances and recolonize rapidly after removal, the focus of conservation policy should shift away from understanding how to resist change to understanding when to stop resisting change. Navigating this decision problem involves trade‐offs among competing objectives, highlighting the need for structured approaches to elicit objective weights that reflect the values of the decision maker. For natural resource managers facing possible ecosystem transformation, this decision framework can enable proactive and strategic decisions made under uncertainty in a changing world.

Keller, Abigail G. [Department of Environment Scie↗

Structure of the C-terminal heme-binding domain of THAP domain containing protein 4 from Homo sapiens

The thanatos (the Greek god of death)-associated protein (THAP) domain is a sequence-specific DNA-binding domain that contains a C2-CH (Cys-Xaa{sub 2-4}-Cys-Xaa{sub 35-50}-Cys-Xaa{sub 2}-His) zinc finger that is similar to the DNA domain of the P element transposase from Drosophila. THAP-containing proteins have been observed in the proteome of humans, pigs, cows, chickens, zebrafish, Drosophila, C. elegans, and Xenopus. To date, there are no known THAP domain proteins in plants, yeast, or bacteria. There are 12 identified human THAP domain-containing proteins (THAP0-11). In all human THAP protein, the THAP domain is located at the N-terminus and is {approx}90 residues in length. Although all of the human THAP-containing proteins have a homologous N-terminus, there is extensive variation in both the predicted structure and length of the remaining protein. Even though the exact function of these THAP proteins is not well defined, there is evidence that they play a role in cell proliferation, apoptosis, cell cycle modulation, chromatin modification, and transcriptional regulation. THAP-containing proteins have also been implicated in a number of human disease states including heart disease, neurological defects, and several types of cancers. Human THAP4 is a 577-residue protein of unknown function that is proposed to bind DNA in a sequence-specific manner similar to THAP1 and has been found to be upregulated in response to heat shock. THAP4 is expressed in a relatively uniform manner in a broad range of tissues and appears to be upregulated in lymphoma cells and highly expressed in heart cells. The C-terminal domain of THAP4 (residues 415-577), designated here as cTHAP4, is evolutionarily conserved and is observed in all known THAP4 orthologs. Several single-domain proteins lacking a THAP domain are found in plants and bacteria and show significant levels of homology to cTHAP4. It appears that cTHAP4 belongs to a large class of proteins that have yet to be fully functionally characterized. On the basis of prior work, we predicted that cTHAP4 is composed of a heme-binding nitrobindin domain, making THAP4 the only human THAP protein predicted to bind a cofactor. Nitrobindin, a recently characterized protein from Arabidopsis thaliana, is structurally similar and exhibits nitric oxide (NO)-binding properties that resemble the heme-binding nitrophorins. Nitrophorins use a heme moiety to store, transport, and release NO in a pH-specific manner. Although the exact function of nitrobindin is not fully known, the similarities between the well-characterized nitrophorins imply a role in NO transport, sensing, or metabolism. To better elucidate the possible function of THAP4, we solved the hemebound structure of cTHAP4 to a resolution of 1.79 {angstrom}.

59 BASIC BIOLOGICAL SCIENCES↗

Effective field theories for superconducting systems with multiple Fermi surfaces

In this work we investigate the description of superconducting systems with multiple Fermi surfaces. For the case of one Fermi surface we re-obtain the result that the superconductor is more precisely described as a topological state of matter. Studying the case of more than one Fermi surface, we obtain the effective theory describing a time reversal symmetric topological superconductor. These results are obtained by employing a general procedure to construct effective low energy actions describing states of electromagnetic systems interacting with charges and defects. The procedure consists in taking into account the proliferation or dilution of these charges and defects and its consequences for the low energy description of the electromagnetic response of the system. We find that the main ingredient entering the low energy characterization of the system with more than one Fermi surface is a non-conservation of the canonical supercurrent triggered by particular vortex configurations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Stochastic scheduling for commercial building cooling systems: considering uncertainty in zone temperature prediction

Here, this paper presents the first attempt to address the uncertainty in zone temperature prediction with stochastic optimization. The uncertain zone temperature is a process uncertainty and has not been considered in the existing stochastic optimization for building control. To fill this gap, we proposed a novel formulation of stochastic optimization to handle process uncertainty in building control. Specifically, we first examined the accuracy of a typical linear model for predicting zone temperature. We then formulated the scheduling of the building cooling system as a stochastic optimization problem over a 24-hour look-ahead period to minimize the electricity cost of the studied building cooling system. After that, we applied the proposed stochastic load scheduling (SLS) to a direct expansion (DX) cooling system that serves a medium office building. Through simulation with a detailed building energy simulation software, EnergyPlus, we evaluated the operational cost and the thermal comfort compared with a deterministic load scheduling. The operation cost of scheduling was found to vary with the level of zone temperature prediction uncertainty. The proposed SLS can mitigate the impacts of uncertain zone temperature predictions on both operational cost and thermal comfort. The evaluation results indicate that the proposed SLS works better when the uncertainty level is more significant.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving cosmological analyses of HI clustering by reducing stochastic noise

High-number-density tracers of large-scale structure, such as the HI-rich galaxies measured by 21 cm intensity mapping, have low sampling noise, making them particularly promising as cosmological probes. At large scales, this sampling noise can be subdominant to other scale-independent contributions to the power spectrum; such contributions arise from nonlinear bias, and exceed the sampling noise if at least one of the associated bias coefficients is sufficiently large. This has important consequences for cosmological constraints obtained from such tracers, since it indicates that using the power spectrum does not lead to optimal constraints even in the linear regime. In this paper, we provide a conservative estimate of the possible improvement in constraining power of a 21 cm survey if one were to use an optimal analysis strategy (such as field-level analysis), where only the true sampling noise enters the error budget. We find that improvements in uncertainties on some cosmological parameters can be as large as 50%, depending on redshift, foreground cleaning efficiency, scales used in the analysis, and instrumental noise. One byproduct of our work is measurements of bias parameters and stochasticity for neutral hydrogen in the IllustrisTNG simulation over a wide range of redshifts; we provide simple fitting formulas for these measurements. Furthermore, our results motivate further exploration of new optimal analysis techniques and provide important insights into the constraining power of current and future 21 cm surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

On a chiral analog of the Einstein-de Haas effect

The Einstein-de Haas effect reveals a transfer of angular momentum from microscopic constituents (electrons) to a macroscopic body, but in the case of massless fermions, one could expect the transfer of the chirality of constituents to macroscopic helical motion. For such a picture to be consistent, the macroscopic helicity is to be conserved classically, to echo the conservation of the angular momentum of a rotating body. The helicity conservation would in turn impose constraints on hydrodynamics of chiral liquids (whose constituents are massless fermions). Essentially, the chiral liquids are dissipation-free, on the classical level. Reservations and alternatives to this scenario are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Institutional Transformation v. 2.6

IX uses whole building analysis, and solar power cost algorithms to evaluate tradeoffs associated with alternative large-scale, long term facilities energy conservation strategies. It is designed to use existing energy simulation tools such as doe2.2 and SAMS to produce detailed results which are then processed at a higher level.

Villa, Daniel↗

Blender Pump Fuel Survey: CRC Project E-95

To increase the number of ethanol blends available in the United States, several states have 'blender pumps' that blend gasoline with flex-fuel vehicle (FFV) fuel. No specification governs the properties of these blended fuels, and little information is available about the fuels sold at blender pumps. No labeling conventions exist, and labeling on the blender pumps surveyed was inconsistent.; Thesurvey samples, collected across the Midwestern United States, included the base gasoline and FFV fuel used in the blends as well as the two lowest blends offered at each station. The samples were tested against the applicable ASTM specifications and for critical operability parameters. Conventional gasoline fuels are limited to 10 vol% ethanol by the U.S. EPA. The ethanol content varied greatlyin the samples. Half the gasoline samples contained some ethanol, while the other half contained none. The FFV fuel samples were all within the specification limits. No pattern was observed for the blend content of the higher ethanol content samples at the same station. Other properties tested were specific to higher-ethanol blends. This survey also tested the properties of fuels containingethanol levels above conventional gasoline but below FFV fuels.

02 PETROLEUM↗

INDEPENDENT TECHNICAL ASSESSMENT OF MANAGEMENT OF STORMWATER AND WASTEWATER AT THE SEPARATIONS PROCESS RESEARCH UNIT (SPRU) DISPOSITION PROJECT, NEW YORK

The U.S. Department of Energy (DOE) is currently evaluating the water management procedures at the Separations Process Research Unit (SPRU). The facility has three issues related to water management that require technical assistance: (1) due to a excessive rainfall event in October, 2010, contaminated water collected in basements of G2 and H2 buildings. As a result of this event, the contractor has had to collect and dispose of water offsite; (2) The failure of a sump pump at a KAPL outfall resulted in a Notice of Violation issued by the New York State Department of Environment and Conservation (NYSDEC) and subsequent Consent Order. On-site water now requires treatment and off-site disposition; and (3) stormwater infiltration has resulted in Strontium-90 levels discharged to the storm drains that exceed NR standards. The contractor has indicated that water management at SPRU requires major staff resources (at least 50 persons). The purpose of this review is to determine if the contractor's technical approach warrants the large number of staff resources and to ensure that the technical approach is compliant and in accordance with federal, state and NR requirements.

54 ENVIRONMENTAL SCIENCES↗

Air-to-Water Heat Pumps With Radiant Delivery in Low-Load Homes

Space conditioning represents nearly 50% of average residential household energy consumption, highlighting the need to identify alternative cost-effective, energy-efficient cooling and heating strategies. As homes are better built, there is an increasing need for strategies that are particularly well suited for high performance, low load homes. ARBI researchers worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump (AWHP) systems, an energy efficient space conditioning solution designed to cost-effectively provide comfort in homes with efficient, safe, and durable operation. Two monitoring projects of test houses in hot-dry climates were initiated in 2010 to test this system. Both systems were fully instrumented and have been monitored over one year to capture complete performance data over the cooling and heating seasons. Results are used to quantify energy savings, cost-effectiveness, and system performance using different operating modes and strategies. A calibrated TRNSYS model was developed and used to evaluate performance in various climate regions. This strategy is most effective in tight, insulated homes with high levels of thermal mass (i.e. exposed slab floors).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Socioeconomic Assessment and Analysis Program

Preliminary review and analyses of residential energy consumption surveys' (various) comparing levels of energy expenditures across population categories.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Hood River Passive House

The Hood River Passive Project was developed by Root Design Build of Hood River Oregon using the Passive House Planning Package (PHPP) to meet all of the requirements for certification under the European Passive House standards. The Passive House design approach has been gaining momentum among residential designers for custom homes and BEopt modeling indicates that these designs may actually exceed the goal of the U.S. Department of Energy's (DOE) Building America program to reduce home energy use by 30%-50% (compared to 2009 energy codes for new homes). This report documents the short term test results of the Shift House and compares the results of PHPP and BEopt modeling of the project. The design includes high R-Value assemblies, extremely tight construction, high performance doors and windows, solar thermal DHW, heat recovery ventilation, moveable external shutters and a high performance ductless mini-split heat pump. Cost analysis indicates that many of the measures implemented in this project did not meet the BA standard for cost neutrality. The ductless mini-split heat pump, lighting and advanced air leakage control were the most cost effective measures. The future challenge will be to value engineer the performance levels indicated here in modeling using production based practices at a significantly lower cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air-to-Water Heat Pumps With Radiant Delivery in Low-Load Homes

Space conditioning represents nearly 50% of average residential household energy consumption, highlighting the need to identify alternative cost-effective, energy-efficient cooling and heating strategies. As homes are better built, there is an increasing need for strategies that are particularly well suited for high performance, low load homes. ARBI researchers worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump systems, an energy efficient space conditioning solution designed to cost-effectively provide comfort in homes with efficient, safe, and durable operation. Two monitoring projects of test houses in hot-dry climates were initiated in 2010 to test this system. Both systems were fully instrumented and have been monitored over one year to capture complete performance data over the cooling and heating seasons. Results are used to quantify energy savings, cost-effectiveness, and system performance using different operating modes and strategies. A calibrated TRNSYS model was developed and used to evaluate performance in various climate regions. This strategy is most effective in tight, insulated homes with high levels of thermal mass (i.e. exposed slab floors).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hood River Passive House

The Hood River Passive Project was developed by Root Design Build of Hood River Oregon using the Passive House Planning Package (PHPP) to meet all of the requirements for certification under the European Passive House standards. The Passive House design approach has been gaining momentum among residential designers for custom homes and BEopt modeling indicates that these designs may actually exceed the goal of the U.S. Department of Energy's (DOE) Building America program to "reduce home energy use by 30%-50% (compared to 2009 energy codes for new homes). This report documents the short term test results of the Shift House and compares the results of PHPP and BEopt modeling of the project. The design includes high R-Value assemblies, extremely tight construction, high performance doors and windows, solar thermal DHW, heat recovery ventilation, moveable external shutters and a high performance ductless mini-split heat pump. Cost analysis indicates that many of the measures implemented in this project did not meet the BA standard for cost neutrality. The ductless mini-split heat pump, lighting and advanced air leakage control were the most cost effective measures. The future challenge will be to value engineer the performance levels indicated here in modeling using production based practices at a significantly lower cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗