Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Large deviations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

An Evolving GeV Spectrum from Prompt to Afterglow: The Case of GRB 160509A

We present the high-energy emission properties of GRB 160509A, from its prompt mission to late afterglow phase. GRB 160509A contains two emission episodes: 0–40 s and 280–420 s after the burst onset (t{sub 0}). The relatively high fluence of GRB 160509A allows us to establish an evolving spectrum above 100 MeV. During the first emission episode, the >100 MeV spectrum is soft with Γ ≥ 3.0, which can be smoothly connected to keV energies with a Band function with or without a high-energy cutoff. The >100 MeV spectrum rapidly changes to a hard spectrum with Γ ≤ 1.5 after t{sub 0}+40 s. The existence of very energetic photons, e.g., a 52 GeV that arrives at t{sub 0}+77 s and a 29 GeV that arrives at t{sub 0}+70 ks, is hard to reconcile by the synchrotron emission from forward-shock electrons, but is likely due to an inverse-Compton (IC) mechanism (e.g., synchrotron self-Compton emission). A soft spectrum (Γ ∼ 2) between 300 and 1000 s after the burst onset is also found at a significance of about 2 standard deviations, which suggests a different emission mechanism at work for this short period of time. GRB 160509A represents the latest example where IC emission has to be taken into account in explaining the afterglow GeV emission, which had been suggested long before the launch of the Fermi Large Area Telescope.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-I-27: Establishing Target Exposure Index Values for Computed Radiography

Purpose: To develop a standard set of target exposure index (TEI) values to be applied to Agfa Computed Radiography (CR) readers in accordance with International Electrotechnical Committee 62494-1 (ed. 1.0). Methods: A large data cohort was collected from six USAF Medical Treatment Facilities that exclusively use Agfa CR Readers. Dose monitoring statistics were collected from each reader. The data was analyzed based on anatomic region, view, and processing speed class. The Agfa specific exposure metric, logarithmic mean (LGM), was converted to exposure index (EI) for each data set. The optimum TEI value was determined by minimizing the number of studies that fell outside the acceptable deviation index (DI) range of +/− 2 for phototimed techniques or a range of +/−3 for fixed techniques. An anthropomorphic radiographic phantom was used to corroborate the TEI recommendations. Images were acquired of several anatomic regions and views using standard techniques. The images were then evaluated by two radiologists as either acceptable or unacceptable. The acceptable image with the lowest exposure and EI value was compared to the recommended TEI values using a passing DI range. Results: Target EI values were determined for a comprehensive list of anatomic regions and views. Conclusion: Target EI values must be established on each CR unit in order to provide a positive feedback system for the technologist. This system will serve as a mechanism to prevent under or overexposures of patients. The TEI recommendations are a first attempt at a large scale process improvement with the goal of setting reasonable and standardized TEI values. The implementation and effectiveness of the recommended TEI values should be monitored and adjustments made as necessary.

60 APPLIED LIFE SCIENCES↗

Bidisperse and polydisperse suspension rheology at large solid fraction

At the same solid volume fraction, bidisperse and polydisperse suspensions display lower viscosities, and weaker normal stress response, compared to monodisperse suspensions. The reduction of viscosity associated with size distribution can be explained by an increase of the maximum flowable, or jamming, solid fraction. In this work, concentrated or "dense" suspensions are simulated under strong shearing, where thermal motion and repulsive forces are negligible, but we allow for particle contact with a mild frictional interaction with interparticle friction coefficient of 0.2. Aspects of bidisperse suspension rheology are first revisited to establish that the approach reproduces established trends; the study of bidisperse suspensions at size ratios of large to small particle radii (2 to 4) shows that a minimum in the viscosity occurs for zeta slightly above 0.5, where zeta=phi_{large}/phi is the fraction of the total solid volume occupied by the large particles. The simple shear flows of polydisperse suspensions with truncated normal and log normal size distributions, and bidisperse suspensions which are statistically equivalent with these polydisperse cases up to third moment of the size distribution, are simulated and the rheologies are extracted. Prior work shows that such distributions with equivalent low-order moments have similar phi_{m}, and the rheological behaviors of normal, log normal and bidisperse cases are shown to be in close agreement for a wide range of standard deviation in particle size, with standard correlations which are functionally dependent on phi/phi_{m} providing excellent agreement with the rheology found in simulation. The close agreement of both viscosity and normal stress response between bi- and polydisperse suspensions demonstrates the controlling in influence of the maximum packing fraction in noncolloidal suspensions. Microstructural investigations and the stress distribution according to particle size are also presented.

Pednekar, Sidhant↗

Examination of Mean Stress Calculation Approaches in Rock Mechanics

The mean stress, as a fundamental statistical property of a group of stress data, is essential for stress variability characterisation. However, currently in rock mechanics, the mean stress is customarily and erroneously calculated by separately averaging the principal stress magnitudes and orientations. In order to draw the attention of our community to the appropriate approach for stress variability characterisation, here we compare the customary scalar/vector mean with that obtained by the mathematically rigorous tensorial approach—the Euclidean mean. Calculation of mean stress using both a small group of actual in situ stress measurement results and a large group of simulated stress data (obtained using the combined finite– discrete element method, FEMDEM) demonstrates that the two approaches yield different results. Further investigation of these results shows that the scalar/vector approach may yield non-unique and non-orthogonal mean principal stresses, and these may deviate significantly from those of the Euclidean mean. Our calculations and comparisons reveal that the scalar/ vector approach is deficient because it processes the principal stress magnitudes and orientations separately as independent quantities and ignores the connection between them. Conversely, the tensorial approach appropriately averages the tensors that simultaneously carry not only the information of stress magnitudes and orientations, but also the inherent relations between them. Therefore, arbitrarily using scalar/vector mean stress of in situ stress measurements as input in further rock engineering analyses may yield significantly erroneous results. Finally, we advise that stress data should be statistically processed in a tensorial manner using tensors referred to a common Cartesian coordinate system.

58 GEOSCIENCES↗

A High Voltage Power Supply That Mitigates Current Reversals in Capillary Zone Electrophoresis-Electrospray Mass Spectrometry

Capillary electrophoresis coupled with electrospray ionization typically employs two power supplies, one at each end of the capillary. One power supply is located at the proximal (injection) end of the capillary. The power supply located at the distal (detector) end of the capillary drives the electrospray. Electrophoresis is driven by the difference in potential between these power supplies. Separations that employ large capillary inner diameter, high conductivity background electrolyte, and high separation potentials generate higher current than that produced by the electrospray. Excess current flows through the electrospray power supply. Most power supplies are not designed to sink current, and the excess current will cause the electrospray voltage to deviate from its set point. We report a simple circuit to handle this excess current, allowing separations under a wide range of electrophoretic conditions. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surprising Effects of Hydrochloric Acid on the Water Evaporation Coefficient Observed by Raman Thermometry

© 2017 American Chemical Society. The kinetics and energetics of cloud droplet and aerosol formation in the atmosphere are strongly influenced by the evaporation and condensation rates of water, yet the magnitude and mechanism of evaporation remains incompletely characterized. Of particular import (and controversy) is the nature of interfacial water pH and its potential effects on evaporation rate and environmental reactivity. We have used Raman thermometry measurements of freely evaporating microdroplets to determine evaporation coefficients (Î) for two different hydrochloric acid solutions, both of which result in a significant deviation from Îwater. At 95% confidence, we find the evaporation coefficient for 1.0 M HCl to be 0.24 ± 0.04, a â-60% decrease relative to pure water, and for 0.1 M HCl to be 0.91 ± 0.08, a â-45% increase relative to pure water. These results suggest a large perturbation in the surface structure induced by either hydronium ions adsorbing to the water surface or by the presence of a Cl-···H3O+ ion-pair moiety in the interfacial region.

Rizzuto, Anthony M↗

Interactions Between the Amazonian Rainforest and Cumuli Clouds: A Large‐Eddy Simulation, High‐Resolution ECMWF, and Observational Intercomparison Study

Abstract The explicit coupling at meter and second scales of vegetation's responses to the atmospheric‐boundary layer dynamics drives a dynamic heterogeneity that influences canopy‐top fluxes and cloud formation. Focusing on a representative day during the Amazonian dry season, we investigate the diurnal cycle of energy, moisture and carbon dioxide at the canopy top, and the transition from clear to cloudy conditions. To this end, we compare results from a large‐eddy simulation technique, a high‐resolution global weather model, and a complete observational data set collected during the GoAmazon14/15 campaign. The overall model‐observation comparisons of radiation and canopy‐top fluxes, turbulence, and cloud dynamics are very satisfactory, with all the modeled variables lying within the standard deviation of the monthly aggregated observations. Our analysis indicates that the timing of the change in the daylight carbon exchange, from a sink to a source, remains uncertain and is probably related to the stomata closure caused by the increase in vapor pressure deficit during the afternoon. We demonstrate quantitatively that heat and moisture transport from the subcloud layer into the cloud layer are misrepresented by the global model, yielding low values of specific humidity and thermal instability above the cloud base. Finally, the numerical simulations and observational data are adequate settings for benchmarking more comprehensive studies of plant responses, microphysics, and radiation.

Vilà‐Guerau de Arellano, J.↗

Target normal sheath acceleration with a large laser focal diameter

In this work, the dependence of the laser-driven ion acceleration from thin titanium foils in the Target Normal Sheath Acceleration (TNSA) regime on target and laser parameters is explored using two dimensional particle-in-cell simulations. The oblique incidence (θ L = 45°) and large focal spot size (w 0 = 40μm) are chosen to take an advantage of quasi one-dimensional geometry of sheath fields and effective electron heating. This interaction setup also reveals low and achromatic angular divergence of a proton beam. It is shown that the hot electron temperature deviates from the ponderomotive scaling for short laser pulses and small pre-plasmas. This deviation is mainly due to the laser sweeping, as the short duration laser pulse each moment in time effectively heats only a fraction of a focal spot on the foil. This instantaneous partial heating results in an electron temperature deviation from the ponderomotive scaling and, thus, lower maximum proton energies than it could have been expected from the TNSA theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fitting FFT-derived spectra: Theory, tool, and application to solar radio spike decomposition

Spectra derived from fast Fourier transform (FFT) analysis of time-domain data intrinsically contain statistical fluctuations whose distribution depends on the number of accumulated spectra contributing to a measurement. The tail of this distribution, which is essential for separating the true signal from the statistical fluctuations, deviates noticeably from the normal distribution for a finite number of accumulations. In this paper, we develop a theory to properly account for the statistical fluctuations when fitting a model to a given accumulated spectrum. The method is implemented in software for the purpose of automatically fitting a large body of such FFT-derived spectra. We apply this tool to analyze a portion of a dense cluster of spikes recorded by our FASR Subsystem Testbed instrument during a record-breaking event that occurred on 2006 December 6. The outcome of this analysis is briefly discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Modular invariant inflation

Modular invariance is a striking symmetry in string theory, which may keep stringy corrections under control. In this paper, we investigate a phenomenological consequence of the modular invariance, assuming that this symmetry is preserved as well as in a four dimensional (4D) low energy effective field theory. As a concrete setup, we consider a modulus field T whose contribution in the 4D effective field theory remains invariant under the modular transformation and study inflation drived by T. The modular invariance restricts a possible form of the scalar potenntial. As a result, large field models of inflation are hardly realized. Meanwhile, a small field model of inflation can be still accomodated in this restricted setup. The scalar potential traced during the slow-roll inflation mimics the hilltop potential V{sub ht}, but it also has a non-negligible deviation from V{sub ht}. Detecting the primordial gravitational waves predicted in this model is rather challenging. Yet, we argue that it may be still possible to falsify this model by combining the information in the reheating process which can be determined self-completely in this setup.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The f ( R ) halo mass function in the cosmic web

An important indicator of modified gravity is the effect of the local environment on halo properties. This paper examines the influence of the local tidal structure on the halo mass function, the halo orientation, spin and the concentration-mass relation. We use the excursion set formalism to produce a halo mass function conditional on large-scale structure. Our simple model agrees well with simulations on large scales at which the density field is linear or weakly non-linear. Beyond this, our principal result is that f ( R ) does affect halo abundances, the halo spin parameter and the concentration-mass relationship in an environment-independent way, whereas we find no appreciable deviation from \text(ΛCDM) for the mass function with fixed environment density, nor the alignment of the orientation and spin vectors of the halo to the eigenvectors of the local cosmic web. There is a general trend for greater deviation from \text(ΛCDM) in underdense environments and for high-mass haloes, as expected from chameleon screening.

79 ASTRONOMY AND ASTROPHYSICS↗

Search for cascade decays of charged sleptons and sneutrinos in final states with three leptons and missing transverse momentum in 𝑝⁢𝑝 collisions at $\sqrt{𝑠} = 13$ TeV with the ATLAS detector

A search for cascade decays of charged sleptons and sneutrinos using final states characterized by three leptons (electrons or muons) and missing transverse momentum is presented. The analysis is based on a dataset with 140 fb −1 of proton-proton (pp) collisions at a center-of-mass energy of $\sqrt{𝑠} = 13$ TeV recorded by the ATLAS detector at the Large Hadron Collider. This paper focuses on a supersymmetric scenario that is motivated by the muon anomalous magnetic moment observation, dark-mattter relic density abundance, and electroweak naturalness. A mass spectrum involving light Higgsinos and heavier sleptons with a bino at intermediate mass is targeted. No significant deviation from the Standard Model expectation is observed. This search enables us to place stringent constraints on this model, excluding at the 95% confidence level charged slepton and sneutrino masses up to 450 GeV when assuming a lightest neutralino mass of 100 GeV and mass-degenerate selectrons, smuons and sneutrinos.

extensions of Higgs sector↗

Jeff=1/2 Mott spin-orbit insulating state close to the cubic limit in Ca4IrO6

The J_eff=1/2 state is manifested in systems with large cubic crystal field splitting and spin-orbit coupling that are comparable to the on-site Coulomb interaction, U. 5d transition metal oxides host parameters in this regime and strong evidence for this state in Sr2IrO4, and additional iridates, has been presented. All the candidates, however, deviate from the cubic crystal field required to provide an unmixed canonical J_eff=1/2 state, impacting the development of a robust model of this novel insulating and magnetic state. We present experimental and theoretical results that not only show Ca4IrO6 hosts the state, but furthermore uniquely resides in the limit required for a canonical unmixed J_eff=1/2 state.

Calder, Stuart A↗

Search for charged-lepton-flavor violating μ τ q t interactions in top-quark production and decay in p p collisions at s = 13 TeV with the ATLAS detector at the LHC

A search for charged-lepton-flavor violating μ τ q t (q = u, c) ) interactions is presented, considering both top-quark production and decay. The data analyzed correspond to 140 fb -1 of proton-proton collisions at a center-of-mass energy of $\sqrt{s}$ = 13 TeV recorded with the ATLAS detector at the Large Hadron Collider. The analysis targets events containing two muons with the same electric charge, a hadronically decaying $\tau$ -lepton and at least one jet, with exactly one b -tagged jet, produced by a μ τ q t interaction. Agreement with the Standard Model expectation within 1.6 standard deviations is observed, and limits are set at the 95% confidence level (CL) on the charged-lepton-flavor violation branching ratio of $\mathcal{B}$(t → μ$\tau$q) < 8.7 x 10 -7 . An effective field theory interpretation is performed yielding 95% CL limits on Wilson coefficients, dependent on the flavor of the associated light quark and the Lorentz structure of the coupling. These range from |c$^{3(2313)}_{lequ}$|Λ 2 < 0.10 TeV -2 for μ$\tau$ut to |c$^{1(2323)}_{lequ}$| /Λ 2 < 1.8 TeV -2 for μ$\tau$ct. An additional interpretation is performed for scalar leptoquark production inducing charged-lepton-flavor violation, with fixed intergenerational couplings. Upper limits on leptoquark coupling strengths are set at the 95% CL, ranging from $\lambda$ LQ = 1.3 to $\lambda$ LQ =3.7 for leptoquark masses between 0.5 and 2.0 TeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-J-129: Atlas Development for Cardiac Automatic Contouring Using Multi-Atlas Segmentation

Purpose: To develop a set of atlases for automatic contouring of cardiac structures to determine heart radiation dose and the associated toxicity. Methods: Six thoracic cancer patients with both contrast and non-contrast CT images were acquired for this study. Eight radiation oncologists manually and independently delineated cardiac contours on the non-contrast CT by referring to the fused contrast CT and following the RTOG 1106 atlas contouring guideline. Fifteen regions of interest (ROIs) were delineated, including heart, four chambers, four coronary arteries, pulmonary artery and vein, inferior and superior vena cava, and ascending and descending aorta. Individual expert contours were fused using the simultaneous truth and performance level estimation (STAPLE) algorithm for each ROI and each patient. The fused contours became atlases for an in-house multi-atlas segmentation. Using leave-one-out test, we generated auto-segmented contours for each ROI and each patient. The auto-segmented contours were compared with the fused contours using the Dice similarity coefficient (DSC) and the mean surface distance (MSD). Results: Inter-observer variability was not obvious for heart, chambers, and aorta but was large for other structures that were not clearly distinguishable on CT image. The average DSC between individual expert contours and the fused contours were less than 50% for coronary arteries and pulmonary vein, and the average MSD were greater than 4.0 mm. The largest MSD of expert contours deviating from the fused contours was 2.5 cm. The mean DSC and MSD of auto-segmented contours were within one standard deviation of expert contouring variability except the right coronary artery. The coronary arteries, vena cava, and pulmonary vein had DSC<70% and MSD>3.0 mm. Conclusion: A set of cardiac atlases was created for cardiac automatic contouring, the accuracy of which was comparable to the variability in expert contouring. However, substantial modification may need for auto-segmented contours of indistinguishable small structures.

60 APPLIED LIFE SCIENCES↗

Cross-section measurements of the Higgs boson decaying to a pair of tau leptons in proton--proton collisions at s = 13 TeV with the ATLAS detector

A measurement of total production cross sections of the Higgs boson in proton-proton collisions is presented in the H -> tau tau decay channel. The analysis is performed using 36.1 fb-1 of data recorded by the ATLAS experiment at the Large Hadron Collider at a center-of-mass energy of 13 TeV. All combinations of leptonic and hadronic tau decays are considered. The H->tau tau signal over the expected background from other Standard Model processes is established with an observed (expected) significance of 4.4 (4.1) standard deviations. Combined with results using data taken at 7 and 8 TeV centre-of-mass energies, the observed (expected) significance amounts to 6.4 (5.4) standard deviations and constitutes an observation of H->tautau decays by the ATLAS experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Galaxy clustering with photometric surveys using PDF redshift information

Here, photometric surveys produce large-area maps of the galaxy distribution, but with less accurate redshift information than is obtained from spectroscopic methods. Modern photometric redshift (photo-z) algorithms use galaxy magnitudes, or colors, that are obtained through multi-band imaging to produce a probability density function (PDF) for each galaxy in the map. We used simulated data to study the effect of using different photo-z estimators to assign galaxies to redshift bins in order to compare their effects on angular clustering and galaxy bias measurements. We found that if we use the entire PDF, rather than a single-point (mean or mode) estimate, the deviations are less biased, especially when using narrow redshift bins. When the redshift bin widths are $\Delta z=0.1$, the use of the entire PDF reduces the typical measurement bias from 5%, when using single point estimates, to 3%.

79 ASTRONOMY AND ASTROPHYSICS↗

Quality assurance of proton beams using a multilayer ionization chamber system

Purpose: The measurement of percentage depth-dose (PDD) distributions for the quality assurance of clinical proton beams is most commonly performed with a computerized water tank dosimetry system with ionization chamber, commonly referred to as water tank. Although the accuracy and reproducibility of this method is well established, it can be time-consuming if a large number of measurements are required. In this work the authors evaluate the linearity, reproducibility, sensitivity to field size, accuracy, and time-savings of another system: the Zebra, a multilayer ionization chamber system.Methods: The Zebra, consisting of 180 parallel-plate ionization chambers with 2 mm resolution, was used to measure depth-dose distributions. The measurements were performed for scattered and scanned proton pencil beams of multiple energies delivered by the Hitachi PROBEAT synchrotron-based delivery system. For scattered beams, the Zebra-measured depth-dose distributions were compared with those measured with the water tank. The principal descriptors extracted for comparisons were: range, the depth of the distal 90% dose; spread-out Bragg peak (SOBP) length, the region between the proximal 95% and distal 90% dose; and distal-dose fall off (DDF), the region between the distal 80% and 20% dose. For scanned beams, the Zebra-measured ranges were compared with those acquired using a Bragg peak chamber during commissioning.Results: The Zebra demonstrated better than 1% reproducibility and monitor unit linearity. The response of the Zebra was found to be sensitive to radiation field sizes greater than 12.5 × 12.5 cm; hence, the measurements used to determine accuracy were performed using a field size of 10 × 10 cm. For the scattered proton beams, PDD distributions showed 1.5% agreement within the SOBP, and 3.8% outside. Range values agreed within −0.1 ± 0.4 mm, with a maximum deviation of 1.2 mm. SOBP length values agreed within 0 ± 2 mm, with a maximum deviation of 6 mm. DDF values agreed within 0.3 ± 0.1 mm, with a maximum deviation of 0.6 mm. For the scanned proton pencil beams, Zebra and Bragg peak chamber range values demonstrated agreement of 0.0 ± 0.3 mm with a maximum deviation of 1.3 mm. The setup and measurement time for all Zebra measurements was 3 and 20 times less, respectively, compared to the water tank measurements.Conclusions: Our investigation shows that the Zebra can be useful not only for fast but also for accurate measurements of the depth-dose distributions of both scattered and scanned proton beams. The analysis of a large set of measurements shows that the commonly assessed beam quality parameters obtained with the Zebra are within the acceptable variations specified by the manufacturer for our delivery system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗