Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LIMB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Sost and its paralog Sostdc1 coordinate digit number in a Gli3-dependent manner

WNT signaling is critical in most aspects of skeletal development and homeostasis, and antagonists of WNT signaling are emerging as key regulatory proteins with great promise as therapeutic agents for bone disorders. Here we show that Sost and its paralog Sostdc1 emerged through ancestral genome duplication and their expression patterns have diverged to delineate nonoverlapping domains in most organ systems including musculoskeletal, cardiovascular, nervous, digestive, reproductive and respiratory. In the developing limb, Sost and Sostdc1 display dynamic expression patterns with Sost being restricted to the distal ectoderm and Sostdc1 to the proximal ectoderm and the mesenchyme. While Sostdc1 –/– mice lack any obvious limb or skeletal defects, Sost –/– mice recapitulate the hand defects described for Sclerosteosis patients. However, elevated WNT signaling in Sost –/–; Sostdc1 –/– mice causes misregulation of SHH signaling, ectopic activation of Sox9 in the digit 1 field and preaxial polydactyly in a Gli1- and Gli3-dependent manner. In addition, we show that the syndactyly documented in Sclerosteosis is present in both Sost –/– and Sost –/–; Sostdc1 –/– mice, and is driven by misregulation of Fgf8 in the AER, a region lacking Sost and Sostdc1 expression. This study highlights the complexity of WNT signaling in skeletal biology and disease and emphasizes how redundant mechanism and non-cell autonomous effects can synergize to unveil new intricate phenotypes caused by elevated WNT signaling.

59 BASIC BIOLOGICAL SCIENCES↗

INTERPLAY OF THREE KINDS OF MOTION IN THE DISK COUNTERPART OF TYPE II SPICULES: UPFLOW, TRANSVERSAL, AND TORSIONAL MOTIONS

Recently, it was shown that the complex dynamical behavior of spicules has to be interpreted as the result of simultaneous action of three kinds of motion: (1) field aligned flows, (2) swaying motions, and (3) torsional motions. We use high-quality observations from the CRisp Imaging SpectroPolarimeter at the Swedish 1-m Solar Telescope to investigate signs of these different kinetic modes in spicules on the disk. Earlier, rapid blue-shifted excursions (RBEs), short-lived absorption features in the blue wing of chromospheric spectral lines, were identified as the disk counterpart of type II spicules. Here we report the existence of similar absorption features in the red wing of the Ca II 8542 and H{alpha} lines: rapid redshifted excursions (RREs). RREs are found over the whole solar disk and are located in the same regions as RBEs: in the vicinity of magnetic field concentrations. RREs have similar characteristics as RBEs: they have similar lengths, widths, lifetimes, and average Doppler velocity. The striking similarity of RREs to RBEs implies that RREs are a manifestation of the same physical phenomenon and that spicules harbor motions that can result in a net redshift when observed on-disk. We find that RREs are less abundant than RBEs: the RRE/RBE detection count ratio is about 0.52 at disk center and 0.74 near the limb. We interpret the higher number of RBEs and the decreased imbalance toward the limb as an indication that field-aligned upflows have a significant contribution to the net Dopplershift of the structure. Most RREs and RBEs are observed in isolation, but we find many examples of parallel and touching RRE/RBE pairs which appear to be part of the same spicule. We interpret the existence of these RRE/RBE pairs and the observation that many RREs and RBEs have varying Dopplershift along their width as signs that torsional motion is an important characteristic of spicules. The fact that most RBEs and RREs are observed in isolation agrees with the idea that transversal swaying motion is another important kinetic mode. We find examples of transitions from RRE to RBE and vice versa. These transitions sometimes appear to propagate along the structure with speeds between 18 and 108 km s{sup -1} and can be interpreted as the sign of a transverse (Alfvenic) wave.

79 ASTRONOMY AND ASTROPHYSICS↗

PROBING FOR EVIDENCE OF PLUMES ON EUROPA WITH HST /STIS

Roth et al. (2014a) reported evidence for plumes of water venting from a southern high latitude region on Europa: spectroscopic detection of off-limb line emission from the dissociation products of water. Here, we present Hubble Space Telescope direct images of Europa in the far-ultraviolet (FUV) as it transited the smooth face of Jupiter to measure absorption from gas or aerosols beyond the Europa limb. Out of 10 observations, we found 3 in which plume activity could be implicated. Two observations showed statistically significant features at latitudes similar to Roth et al., and the third at a more equatorial location. We consider potential systematic effects that might influence the statistical analysis and create artifacts, and are unable to find any that can definitively explain the features, although there are reasons to be cautious. If the apparent absorption features are real, the magnitude of implied outgassing is similar to that of the Roth et al. feature; however, the apparent activity appears more frequently in our data.

79 ASTRONOMY AND ASTROPHYSICS↗

PANCHROMATIC IMAGING OF A TRANSITIONAL DISK: THE DISK OF GM AUR IN OPTICAL AND FUV SCATTERED LIGHT

We have imaged GM Aurigae with the Hubble Space Telescope , detected its disk in scattered light at 1400 and 1650 Å, and compared these with observations at 3300 Å, 5550 Å, 1.1 μ m, and 1.6 μ m. The scattered light increases at shorter wavelengths. The radial surface brightness profile at 3300 Å shows no evidence of the 24 au radius cavity that has been previously observed in submillimeter observations. Comparison with dust grain opacity models indicates that the surface of the entire disk is populated with submicron grains. We have compiled a spectral energy distribution from 0.1 μ m to 1 mm and used it to constrain a model of the star + disk system that includes the submillimeter cavity using the Monte Carlo radiative transfer code by Barbara Whitney. The best-fit model image indicates that the cavity should be detectable in the F330W bandpass if the cavity has been cleared of both large and small dust grains, but we do not detect it. The lack of an observed cavity can be explained by the presence of submicron grains interior to the submillimeter cavity wall. We suggest one explanation for this that could be due to a planet of mass <9 M {sub J} interior to 24 au. A unique cylindrical structure is detected in the far-UV data from the Advanced Camera for Surveys/Solar Blind Channel. It is aligned along the system semiminor axis, but does not resemble an accretion-driven jet. The structure is limb brightened and extends 190 ± 35 au above the disk midplane. The inner radius of the limb brightening is 40 ± 10 au, just beyond the submillimeter cavity wall.

79 ASTRONOMY AND ASTROPHYSICS↗

ARE INTERNETWORK MAGNETIC FIELDS IN THE SOLAR PHOTOSPHERE HORIZONTAL OR VERTICAL?

Using many observations obtained during 2007 with the Spectro-Polarimeter of the Hinode Solar Optical Telescope , we explore the angular distribution of magnetic fields in the quiet internetwork regions of the solar photosphere. Our work follows from the insight of Stenflo, who examined only linear polarization signals in photospheric lines, thereby avoiding complications of the analysis arising from the differing responses to linear and circular polarization. We identify and isolate regions of a strong polarization signal that occupy only a few percent of the observed quiet Sun area yet contribute most to the net linear polarization signal. The center-to-limb variation of the orientation of linear polarization in these strong signal regions indicates that the associated magnetic fields have a dominant vertical orientation. In contrast, the great majority of the solar disk is occupied by much weaker linear polarization signals. The orientation of the linear polarization in these regions demonstrates that the field orientation is dominantly horizontal throughout the photosphere. We also apply our analysis to Stokes profiles synthesized from the numerical MHD simulations of Rempel as viewed at various oblique angles. The analysis of the synthetic data closely follows that of the observations, lending confidence to using the simulations as a guide for understanding the physical origins of the center-to-limb variation of linear polarization in the quiet Sun area.

79 ASTRONOMY AND ASTROPHYSICS↗

Enhanced Polarized Emission from the One-parsec-scale Hotspot of 3C 84 as a Result of the Interaction with the Clumpy Ambient Medium

We present Very Long Baseline Array polarimetric observations of the innermost jet of 3C 84 (NGC 1275) at 43 GHz. A significant polarized emission is detected at the hotspot of the innermost restarted jet, which is located 1 pc south from the radio core. While the previous report presented a hotspot at the southern end of the western limb, the hotspot location has been moved to the southern end of the eastern limb. Faraday rotation is detected within an entire bandwidth of the 43 GHz band. The measured rotation measure (RM) is at most (6.3 ± 1.9) × 10{sup 5} rad m{sup −2} and might be slightly time variable on the timescale of a month by a factor of a few. Our measured RM and the RM previously reported by the CARMA and SMA observations cannot be consistently explained by the spherical accretion flow with a power-law profile. We propose that a clumpy/inhomogeneous ambient medium is responsible for the observed RM. Using an equipartition magnetic field, we derive the electron density of 2 × 10{sup 4} cm{sup −3}. Such an electron density is consistent with the cloud of the narrow line emission region around the central engine. We also discuss the magnetic field configuration from the black hole scale to the parsec scale and the origin of low polarization.

79 ASTRONOMY AND ASTROPHYSICS↗

A NEW METHOD TO QUANTIFY AND REDUCE THE NET PROJECTION ERROR IN WHOLE-SOLAR-ACTIVE-REGION PARAMETERS MEASURED FROM VECTOR MAGNETOGRAMS

Projection errors limit the use of vector magnetograms of active regions (ARs) far from the disk center. In this Letter, for ARs observed up to 60° from the disk center, we demonstrate a method for measuring and reducing the projection error in the magnitude of any whole-AR parameter that is derived from a vector magnetogram that has been deprojected to the disk center. The method assumes that the center-to-limb curve of the average of the parameter’s absolute values, measured from the disk passage of a large number of ARs and normalized to each AR’s absolute value of the parameter at central meridian, gives the average fractional projection error at each radial distance from the disk center. To demonstrate the method, we use a large set of large-flux ARs and apply the method to a whole-AR parameter that is among the simplest to measure: whole-AR magnetic flux. We measure 30,845 SDO /Helioseismic and Magnetic Imager vector magnetograms covering the disk passage of 272 large-flux ARs, each having whole-AR flux >10{sup 22} Mx. We obtain the center-to-limb radial-distance run of the average projection error in measured whole-AR flux from a Chebyshev fit to the radial-distance plot of the 30,845 normalized measured values. The average projection error in the measured whole-AR flux of an AR at a given radial distance is removed by multiplying the measured flux by the correction factor given by the fit. The correction is important for both the study of the evolution of ARs and for improving the accuracy of forecasts of an AR’s major flare/coronal mass ejection productivity.

79 ASTRONOMY AND ASTROPHYSICS↗

Image Processing for Planetary Limb/Terminator Extraction

A novel image segmentation technique for extracting limb and terminator of planetary bodies is proposed. Conventional edge- based histogramming approaches are used to trace object boundaries. The limb and terminator bifurcation is achieved by locating the harmonized segment in the two equations representing the 2-D parameterized boundary curve. Real planetary images from Voyager 1 and 2 served as representative test cases to verify the proposed methodology.

image processing planetary limb planetary terminat↗

Global navigation satellite sounding of the atmosphere and GNSS altimetry : prospects for geosciences

The vast illuminating power of the Global Positioning System (GPS), which transformed space geodesy in the 199Os, is now serving to probe the earth's fluid envelope in unique ways. Three distinct techniques have emerged: ground-based sensing of the integrated atmospheric moisture; space-based profiling of atmospheric refractivity, pressure, temperature, moisture, and other properties by active limb sounding; and surface (ocean and ice) altimetry and scatterometry with reflected signals detected from space. Ground-based GPS moisture sensing is already in provisional use for numerical weather prediction. Limb sounding, while less mature, offers a bevy of attractions, including high accuracy, stability, and vertical resolution; all-weather operation; and exceptionally low cost. GPS bistatic radar, r 'reflectometry,' is the least advanced but shows promise for a number of niche applications.

occultation↗

Driving ATHLETE: Analysis of Operational Efficiency

The All-Terrain Hex-Limbed Extra-Terrestrial Explorer (ATHLETE) is a modular mobility and manipulation platform being developed to support NASA operations in a variety of missions, including exploration of planetary surfaces. The agile system consists of a symmetrical arrangement of six limbs, each with seven articulated degrees of freedom and a powered wheel. This design enables transport of bulky payloads over a wide range of terrain and is envisioned as a tool to mobilize habitats, power-generation equipment, and other supplies for long-range exploration and outpost construction. In 2010, ATHLETE traversed more than 80 km in field environments over eight weeks of testing, demonstrating that the concept is well suited to long-range travel. However, while ATHLETE is designed to travel at speeds of up to 5 kilometers per hour, the observed average traverse rate during field-testing rarely exceeded 1.5 kilometers per hour. This paper investigates sources of inefficiency in ATHLETE traverse operations and identifies targets for improvement of overall traverse rate.

traverse↗

Associations between cumulative environmental quality and ten selected birth defects in Texas

Abstract Background Causes of most birth defects are largely unknown. Genetics, maternal factors (e.g., age, smoking) and environmental exposures have all been linked to some birth defects, including neural tube, oral cleft, limb reduction, and gastroschisis; however, the contribution of cumulative exposures across several environmental domains in association with these defects is not well understood. Methods The Environmental Quality Index (EQI) and its domains (air, water, land, sociodemographic, built) were used to estimate county‐level cumulative environmental exposures from 2006–2010 and matched to birth defects identified from Texas Birth Defects Registry and live birth records from births in years 2007–2010 ( N = 1,610,709). Poisson regression models estimated prevalence ratios (PR) and 95% confidence intervals (CI) for associations between 10 birth defects and the EQI. Results We observed some positive associations between worst environmental quality and neural tube, anencephaly, spina bifida, oral cleft, cleft palate, cleft lip with and without cleft palate, and gastroschisis [PR range: 1.12–1.55], but near null associations with limb reduction defects. Among domain specific results, we observed the strongest positive associations with the sociodemographic domain across birth defects but varied positive associations among the air and water domains, and negative or null associations with the land and built domains. Overall, few exposure‐response patterns were evident. Conclusions Our results highlight the complexities of cumulative, simultaneous environmental exposures in the prevalence rates of 10 selected birth defects. We were able to explore the impact of overall and domain specific environmental quality on birth defects and identify potential domain specific drivers of these associations.

Krajewski, Alison K.↗

Cryoplasty Versus Conventional Balloon Angioplasty of the Femoropopliteal Artery in Diabetic Patients: Long-Term Results from a Prospective Randomized Single-Center Controlled Trial

The purpose of this study was to investigate the immediate and long-term results of cryoplasty versus conventional balloon angioplasty in the femoropopliteal artery of diabetic patients. Fifty diabetic patients (41 men, mean age 68 years) were randomized to cryoplasty (group CRYO; 24 patients with 31 lesions) or conventional balloon angioplasty (group COBA; 26 patients with 34 lesions) of the femoropopliteal artery. Technical success was defined as <30% residual stenosis without any adjunctive stenting. Primary end points included technical success, primary patency, binary in-lesion restenosis (>50%), and freedom from target lesion recanalization. Cox proportional hazards regression analysis was performed to adjust for confounding factors of heterogeneity. In total, 61.3% (19 of 31) in group CRYO and 52.9% (18 of 34) in group COBA were de novo lesions. More than 70% of the lesions were Transatlantic Inter-Society Consensus (TASC) B and C in both groups, and 41.4% of the patients in group CRYO and 38.7% in group COBA suffered from critical limb ischemia. Immediate technical success rate was 58.0% in group CRYO versus 64.0% in group COBA (p = 0.29). According to 3-year Kaplan-Meier estimates, there were no significant differences with regard to patient survival (86.8% in group CRYO vs. 87.0% in group COBA, p = 0.54) and limb salvage (95.8 vs. 92.1% in groups CRYO and COBA, respectively, p = 0.60). There was a nonsignificant trend of increased binary restenosis in group CRYO (hazard ratio [HR] 1.3; 95% CI 0.6-2.6, p = 0.45). Primary patency was significantly lower in group CRYO compared with group COBA (HR 2.2; 95% CI 1.1-4.3, p = 0.02). Significantly more repeat intervention events because of recurrent symptoms were required in group CRYO (HR 2.5; 95% CI 1.2-5.3, p = 0.01). Cryoplasty was associated with lower primary patency and more clinically driven repeat procedures after long-term follow-up compared with conventional balloon angioplasty.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cost-Effectiveness Analysis of Infrapopliteal Drug-Eluting Stents

IntroductionThere are no cost-utility data about below-the-knee placement of drug-eluting stents. The authors determined the cost-effectiveness of infrapopliteal drug-eluting stents for critical limb ischemia (CLI) treatment. The event-free individual survival outcomes defined by the absence of any major events, including death, major amputation, and target limb repeat procedures, were reconstructed on the basis of two published infrapopliteal series. The first included spot Bail-out use of Sirolimus-eluting stents versus bare metal stents after suboptimal balloon angioplasty (Bail-out SES).The second was full-lesion Primary Everolimus-eluting stenting versus plain balloon angioplasty and bail-out bare metal stenting as necessary (primary EES). The number-needed-to-treat (NNT) to avoid one major event and incremental cost-effectiveness ratios (ICERs) were calculated for a 3-year postprocedural period for both strategies. Overall event-free survival was significantly improved in both strategies (hazard ratio (HR) [confidence interval (CI)]: 0.68 [0.41-1.12] in Bail-out SES and HR [CI]: 0.53 [0.29-0.99] in Primary EES). Event-free survival gain per patient was 0.89 (range, 0.11-3.0) years in Bail-out SES with an NNT of 4.6 (CI: 2.5-25.6) and a corresponding ICER of 6,518 Euro-Sign (range 1,685-10,112 Euro-Sign ). Survival gain was 0.91 (range 0.25-3.0) years in Primary EES with an NNT of 2.7 (CI: 1.7-5.8) and an ICER of 11,581 Euro-Sign (range, 4,945-21,428 Euro-Sign ) per event-free life-year gained. Two-way sensitivity analysis showed that stented lesion length >10 cm and/or DES list price >1000 Euro-Sign were associated with the least economically favorable scenario in both strategies. Both strategies of bail-out SES and primary EES placement in the infrapopliteal arteries for CLI treatment exhibit single-digit NNT and relatively low corresponding ICERs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of Diabetic Foot in a Selected Population of Patients with Below-the-Knee Disease: Is the Angiosome Model Effective?

Purpose. To evaluate the efficacy of percutaneous transluminal angioplasty (PTA) in a selected population of diabetic patients with below-the-knee (BTK) disease and to analyze the reliability of the angiosome model. Methods. We made a retrospective analysis of the results of PTA performed in 201 diabetic patients with BTK-only disease treated at our institute from January 2005 to December 2011. We evaluated the postoperative technical success, and at 1, 6, and 12 months' follow-up, we assessed the rates and values of partial and complete ulcer healing, restenosis, major and minor amputation, limb salvage, and percutaneous oximetry (TcPO{sub 2}) (Student's t test). We used the angiosome model to compare different clinicolaboratory outcomes in patients treated by direct revascularization (DR) from patients treated with indirect revascularization (IR) technique by Student's t test and the {chi}{sup 2} test. Results. At a mean {+-} standard deviation follow-up of 17.5 {+-} 12 months, we observed a mortality rate of 3.5 %, a major amputation rate of 9.4 %, and a limb salvage rate of 87 % with a statistically significant increase of TcPO{sub 2} values at follow-up compared to baseline (p < 0.05). In 34 patients, treatment was performed with the IR technique and in 167 by DR; in both groups, there was a statistically significant increase of TcPO{sub 2} values at follow-up compared to baseline (p < 0.05), without statistically significant differences in therapeutic efficacy. Conclusion. PTA of the BTK-only disease is a safe and effective option. The DR technique is the first treatment option; we believe, however, that IR is similarly effective, with good results over time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rearfoot Transcutaneous Oximetry is a Useful Tool to Highlight Ischemia of the Heel

PurposeTo demonstrate the usefulness of rearfoot transcutaneous oximetry to assess the peripheral arterial disease in diabetic patients with heel ulcer.MethodsFrom our database of 550 critical limb ischemia diabetic patients followed after a percutaneous transluminal angioplasty, we have selected patients with below the knee arterial disease. Patients were grouped according to the dorsal transcutaneous oximetry value (Group A < 30 mmHg; Group B ≥ 30 mmHg). Patients of Group B had a second oximetry performed at the rearfoot, close to the lesion localized in all cases at the heel. Finally, the analysis of the arterial pattern disease has been done.ResultsWe selected 191 patients: Group A (151 patients), dorsal transcutaneous oximetry of 11.8 ± 0.7 mmHg; Group B (40 patients), dorsal transcutaneous oximetry of 44.2 ± 10.1 mmHg. In Group B, rearfoot oximetry was 20.5 ± 5 mmHg, significantly lower than dorsal oximetry (p = 0.0179). The anterior tibial artery was involved in all patients of Group A. In Group B, the anterior tibial artery was involved in 15 subjects and never alone; the posterior tibial artery was involved in 20 subjects and in 11 cases alone. The peroneal artery was affected in 20 subjects and in 14 patients alone.ConclusionWhen a heel lesion is present and the transcutaneous oximetry recorded on the dorsum of the foot does not confirm the presence of critical limb ischemia (not ≤30 mmHg), a second oximetry recorded on the rearfoot is useful to point out ischemia of the peroneal artery and/or of the posterior tibial artery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combined Static and Dynamic Computed Tomography Angiography of Peripheral Artery Occlusive Disease: Comparison with Magnetic Resonance Angiography

PurposeTo compare in patients with known peripheral artery occlusive disease (PAOD), image quality of a combined CTA to a combined MRA protocol, including both static and dynamic acquisitions.Materials and MethodsTwenty-two patients with PAOD were examined with a combined CTA and MRA protocol consisting of static acquisitions (s-CTA, s-MRA) of the entire runoff and dynamic acquisitions (d-CTA, d-MRA) of the calves. Two radiologists compared image quality of the s-MRA versus s-CTA as well as d-MRA versus d-CTA. Image quality was assessed on a segmental basis using a 4-point Likert scale.ResultsFor s-CTA, 76% of segments were rated as excellent or good. For s-MRA, 50% of segments were rated as excellent or good (p < 0.0001). For d-CTA, median image quality score for all segments was rated as excellent for both readers. For d-MRA, median image quality for the different segments ranged from moderate to good. For both d-CTA and d-MRA, the median image quality scores were significantly higher for all segments of the lower limb compared with the static examinations of the lower limb segments (all p values < 0.0001). In patients with PAOD category 4–6, 80% of segments were rated as excellent or good for d-CTA, while 45% of segments were rated as poor or non-diagnostic for d-MRA.ConclusionIn patients with known PAOD, a combined static and dynamic CTA examination improves image quality relative to static and dynamic MRA and should be considered as an alternative to MRA, particularly in patients with advanced stage PAOD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advanced strategies for the development of porous carbon as a Li host/current collector for lithium metal batteries

Lithium metal is considered a promising anode material for high-energy-density rechargeable batteries because of its high specific theoretical capacity (3860 mAh g -1 , low mass density (0.534 g cm -3 ), and low electrochemical redox potential (-3.04 V vs. the standard hydrogen electrode). However, the high reactivity of Li with the electrolyte leads to the formation of an unstable solid electrolyte interphase (SEI) and continuous side reactions. Also, the non-uniform lithium-ion flux and infinite volume expansion of Li metal cause the growth of Li dendrites. These pose significant safety challenges and cause rapid capacity fading of the lithium metal batteries (LiMBs). To resolve these issues, a low-cost, easily processed, lightweight, high-performance carbon-based porous matrix is considered promising to host Li metal deposition. The three-dimensional (3D) porous nano/microstructured carbon provides sufficient space for Li accommodation during Li plating, buffers the volume changes during Li plating/stripping, and lowers the effective current density contributing to dendrite-free Li deposition. Besides, the outstanding electrochemical and mechanical stability, flexibility and the high electronic conductivity enable the nano/microstructured carbon to serve as both Li host and current collector. The development of 3D carbon/Li composite by mechanical roll-press techniques not only eliminates the complex and risky procedure of making carbon/Li composite based on Li plating or molten Li infusion but also stabilizes the capacity at higher Li plating/stripping rates. Recently, there is an advancement in the lithiophilic decorations of 3D structure to introduce sufficient nucleation sites and the development of artificial SEI on top of the 3D matrix to suppress Li dendrite formation. Such 3D structural modifications create a uniform electric field, lower the Li nucleation overpotential, provide strong mechanical and chemical stability, and stabilize the interface thereby inhibiting the degradation of lithium and the electrolyte. Here we summarize the research progress on porous carbon/Li composites in terms of materials type, structure, fabrication technique, their electrochemical battery performance, and identify the critical challenges that need to be addressed for high-energy-density practical LiMBs.

25 ENERGY STORAGE↗

Primary Tumor Necrosis Predicts Distant Control in Locally Advanced Soft-Tissue Sarcomas After Preoperative Concurrent Chemoradiotherapy

Purpose: Various neoadjuvant approaches have been evaluated for the treatment of locally advanced soft-tissue sarcomas. This retrospective study describes a uniquely modified version of the Eilber regimen developed at the University of Chicago. Methods and Materials: We treated 34 patients (28 Stage III and 6 Stage IV) with locally advanced soft-tissue sarcomas of an extremity between 1995 and 2008. All patients received preoperative therapy including ifosfamide (2.5 g/m2 per day for 5 days) with concurrent radiation (28 Gy in 3.5-Gy daily fractions), sandwiched between various chemotherapy regimens. Postoperatively, 47% received further adjuvant chemotherapy. Results: Most tumors (94%) were Grade 3, and all were T2b, with a median size of 10.3 cm. Wide excision was performed in 29 patients (85%), and 5 required amputation. Of the resected tumor specimens, 50% exhibited high (>=90%) treatment-induced necrosis and 11.8% had a complete pathologic response. Surgical margins were negative in all patients. The 5-year survival rate was 42.3% for all patients and 45.2% for Stage III patients. For limb-preservation patients, the 5-year local control rate was 89.0% and reoperation was required for wound complications in 17.2%. The 5-year freedom-from-distant metastasis rate was 53.4% (Stage IV patients excluded), and freedom from distant metastasis was superior if treatment-induced tumor necrosis was 90% or greater (84.6% vs. 19.9%, p = 0.02). Conclusions: This well-tolerated concurrent chemoradiotherapy approach yields excellent rates of limb preservation and local control. The resulting treatment-induced necrosis rates are predictive of subsequent metastatic risk, and this information may provide an opportunity to guide postoperative systemic therapies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗