Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ITERATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Measurements of He-like Argon on TEXTOR, a benchmark Experiment for the ITER X-ray Spectrometer

On TEXTOR, measurements of He-like argon lines with an imaging Bragg spectrometer have been performed. The instrument had a layout similar to the x-ray spectrometers planned for ITER and was comparable in size and Bragg angle. The experiments showed that the required accuracy in the measurement of the ion temperature is obtained, for the plasma rotation, additional measurements of absolute line position and relative measurements with secondary standards such as x-ray fluorescence lines are required.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An EUV narrow band imaging technique for diagnosing 10-30 keV ITER plasmas

In this paper we investigate the use of lines from tungsten (W) ions to measure the properties of W impurities in ITER plasmas. We calculate the intensities of the brightest spectral lines expected to be radiated by W ions with wavelengths longer than 45 A, abundance of 10{sup -4} and at densities of 10{sup 20} m{sup 3}. Using the calculated wavelengths and intensities we propose a concept for segmented multilayer-coated imaging telescopes that could be used to investigate the properties of W impurities as a function of time and space using spectral lines from highly ionized W.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Concept And Development Of Instruments For ITER Thermography

We give here a short overview of the status of the development for ITER thermography as performed by the CEA-Cadarache and some of its collaboration partners. The topics that have been included in this synthesis are the status of the optical design, the role of multi-wavelength mesurements, multicolour pyroreflectometry, photothermal methods, and reflection simulations and measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fusion Power Measurement Using a Combined Neutron Spectrometer-Camera System at ITER

A central task for fusion plasma diagnostics is to measure the 2.5 and 14 MeV neutron emission rate in order to determine the fusion power. A new method for determining the neutron yield has been developed at JET. It makes use of the magnetic proton recoil neutron spectrometer and a neutron camera and provides the neutron yield with small systematic errors. At ITER a similar system could operate if a high-resolution, high-performance neutron spectrometer similar to the MPR was installed. In this paper, we present how such system could be implemented and how well it would perform under different assumption of plasma scenarios and diagnostic capabilities. It is found that the systematic uncertainty for using such a system as an absolute calibration reference is as low as 3% and hence it would be an excellent candidate for the calibration of neutron monitors such as fission chambers. It is also shown that the system could provide a 1 ms time resolved estimation of the neutron rate with a total uncertainty of 5%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of Escaping Alpha Particle Orbits for Detector Design on ITER

The placement of lost alpha particle detectors in ITER has been studied using a full gyro-motion orbit calculation code, in which the orbit is located in the plasma side of the first wall boundary. Detection rates are likely to be low with the detector is placed inside the blanket. Tilting the modules so that they interfere less gives a significantly higher probability of detection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On The Problem Of In-vessel Mirrors For Diagnostic Systems Of ITER

The present status of the investigations with ITER-candidate mirror materials and directed on solution of the in-vessel mirror problem, are presented in the paper. The current tasks in the R and D of diagnostic mirrors and outstanding questions are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gamma-irradiation tests of IR optical fibres for ITER thermography--a case study

In the course of the development of a concept for a spectrally resolving infrared thermography diagnostic for the ITER divertor we have tested 3 types of infrared (IR) fibres in Co{sup 60} irradiation facilities under {gamma} irradiation. The fibres were ZrF{sub 4} (and HfF{sub 4}) fibres from different manufacturers, hollow fibres (silica capillaries with internal Ag/AgJ coating) and a sapphire fibre. For the IR range, only the latter fibre type encourages to go further for neutron tests in a reactor. If one restricted the interest onto the near infrared range, high purity core silica fibres could be used. This study might be seen as a typical example of the relation between diagnostic development for a nuclear environment and irradiation experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance analysis of ITER tomographic systems

A method based on the Bayesian statistical analysis is proposed to measure the performance of ITER tomographic systems. This method can quantify the performance of the systems and helps in the diagnostic design.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Physics of ECE Temperature Measurements and Prospects for ITER

The physics of the electron cyclotron emission (ECE) temperature measurements is reviewed. The current understanding of the expected ECE spectra in ITER is summarized, for perpendicular as well as oblique propagation. The relevance of the use of oblique ECE for investigating the shape of the electron distribution function at low energies is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DESIGN, ANALYSIS AND TEST CONCEPT FOR PROTOTYPE CRYOLINE OF ITER

The ITER cryo-distribution and cryoline is a part of the in-kind supply for India. The design of the systems is in progress. The topology of torus and neutral beam cryoline is defined as six process pipes along with thermal shield at 80 K and outer vacuum jacket. In order to develop confidence in the concept and to establish the high level of engineering and manufacturing technology, a prototype testing has been proposed. The prototype test will be carried out on 1:1 model in terms of dimension. However, the mass flow rate of the supercritical helium at 4.5 K and gaseous helium at 80 K will be on a 1:10 scale. The prototype cryoline has been designed and analyzed for thermal, structural and hydraulic parameters. The objective of this prototype test is to verify mechanical behavior due to thermal stress and pressure force, thermal and hydraulic performances. The concept of test facility has been realized along with the Piping and Instrumentation (P and I) diagram, instrumentation, controls, data acquisition, 80 K helium generation system along with supply and return valve boxes and interfacing hardware. The design concept, methodology for analysis and results, as well as the test facility have been discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High resolution fast wave reflectometry: JET design and implications for ITER

The measurement of the fuel mixture remains a very difficult task in thermonuclear plasmas, where the hydrogen isotopes are fully stripped and do not emit line radiation. On the other hand, direct determination of the ion species mix will be essential in the reactor to keep the mixture close to 50/50 and maximize the fusion output. In this paper, the design of fast wave reflectometry for JET is reviewed to show the potential of such a method in the perspective of ITER. The main design elements of the antenna and the detection system, based on vectorial measurements, are reported. The main challenges to such a diagnostic, mainly the intrinsic ion cyclotron emission from the plasma and the extensive use of ion cyclotron radiofrequencies as additional heating, are addressed in detail. The overall design indicates that the proposed system would be able to provide a measurement of the fuel ratio with spatial resolution in the range of few centimeters and temporal resolution in the range of 1 ms in the vast majority of JET scenarios.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron spectrometer for ITER using silicon detectors

High resolution neutron spectrometers provide information about plasma parameters at existing fusion experiments. Such a system may also be employed at ITER. Proton recoil telescopes have classically been used to detect neutrons with good energy resolution but poor efficiency. Using annular silicon detectors, it is possible to greatly increase the solid angle coverage and hence improve efficiency. Based on a simulation (MCNPX) study, the scaling of energy resolution, efficiency, and time to determine an ion temperature to 10% accuracy on foil thickness and detector location is shown. The latter quantity is used to determine the optimum foil thickness and detector geometry for specific plasma temperatures. For a 20 keV deuterium-tritium (DT) plasma, 5.3% resolution with efficiency of 2.9x10{sup -4} n cm{sup 2} is attainable using the available detectors. This gives a temperature measurement with 10% accuracy in 1.1 ms for a neutron flux of 2x10{sup 9} n cm{sup -2}. Multiple detectors can be used to further increase the efficiency if needed. A system of this kind could be tested in a future DT campaign at, for example, JET.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress of the ITER equatorial vis/IR wide angle viewing system optical design

The equatorial vis/IR wide angle viewing system is present in four ITER diagnostic equatorial ports. This instrument will cover a large field of view with high spatial and temporal resolutions, to provide real time temperature measurements of plasma facing components, spectral data in the visible range, information on runaway electrons, and pellet tracking. This diagnostic needs to be reliable, precise, and long lasting. Its design is driven by both the tokamak severe environment and the high performances required for machine protection. The preliminary design phase is ongoing. Paramount issues are being tackled, relative to wide spectral band optical design, material choice, and optomechanical difficulties due to the limited space available for this instrument in the ports, since many other diagnostics and services are also present. Recent progress of the diagnostic optical design and status of associated R and D are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The diagnostic system of the neutral beam injectors for ITER heating and current drive

The neutral beam injectors for ITER are designed to deliver hydrogen or deuterium atoms accelerated at 1 MV for a total power of 34 MW. Design of the neutral beam and of the ion source test facilities is presently ongoing. Among the various activities, also the definition and assessment of necessary diagnostics are being carried out. Within this framework, requirements and constraints of the diagnostic system will be discussed in the present paper with the aim of providing data relevant for protection, operation, characterization, and improvement of the performances of the test facilities. The definition of the most suitable locations for the diagnostics and of their preliminary integration into the mechanical design will be proposed. Proposals for the extraction of signals from the high voltage components will also be presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ITER LIDAR performance analysis

The core LIDAR Thomson scattering for ITER is specified for core profile measurements with a spatial resolution of 7 cm (a/30) for the range of 500 eV<T{sub e}<40 keV and n{sub e}>3x10{sup 19} m{sup -3} at an accuracy of <10% for T{sub e}. These specifications are verified using a full profile Monte Carlo simulation code. In the simulations it is assumed that the input transmission is 50% and the collection transmission is 10% for {lambda}=300-1200 nm and F/=6-17. A crucial design decision lies on the choice of laser and detector combination. It is evaluated that the system can meet its spatial and accuracy specifications for higher temperatures of T{sub e}>5 keV with a combination of a neodymium-doped yttrium aluminum garnet (Nd:YAG) laser ({lambda}{sub 0}=1064 nm, {delta}{lambda}<1 nm, 5 J, and {delta}t{sub FWHM}=250 ps, 5-10 Hz) and S20, GaAs, and GaAsP microchannel plate photomultipliers ({delta}t{sub FWHM}<300 ps, effective quantum efficiency, EQE=3%-4%, and D=18 mm). In order to reach the required T{sub e} of 500 eV with Nd:YAG first harmonic, this choice requires a development of fast near infrared detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of the ITER CXRS design by tests on TEXTOR

The charge exchange recombination spectroscopy system (CXRS) for ITER is designed to measure the core helium concentration, and in addition, profiles of ion temperature and rotation. This highly demanding task, due to the huge background radiation (bremsstrahlung) and the high attenuation of the dedicated diagnostic neutral beam, requires high throughput spectrometers with high resolution. On TEXTOR, a CXRS system has been developed with the aim to test the physics implications of these specifications. (i) A relevant spectrometer has been tested. (ii) A method to determine the helium concentrations from the CXRS intensity, using the beam emission has been evaluated. A 20% discrepancy in beam emission was revealed. (iii) The determination of the magnetic pitch angle by the ratio of Balmer lines showed qualitatively the right behavior, although the accuracy was limited by the polarization sensitivity of the first mirror. (iv) The simulation code developed for the prediction of the CXRS spectra was quantitatively confronted with experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In-vessel design of ITER diagnostic neutron activation system

A neutron activation system utilizing an encapsulated metal sample technique will be implemented to evaluate total fusion power from ITER plasma. The positions of seven irradiation ends for each poloidal section are determined to optimize the measurements from asymmetric, elongated plasma with minimum uncertainty. To determine the exact location of the irradiation end, some physical and technical aspects for each location are investigated. Monte Carlo neutronic calculations are performed to assess the physical characteristics and optimize the design of each irradiation end.

36 MATERIALS SCIENCE↗

ProVac3D and Application to the Neutral Beam Injection System of ITER

In order to heat the confined plasma up to 100 million degrees Celsius and initiate a sustained fusion reaction, ITER will use several heating mechanisms at the same time, of which Neutral Beam Injection (NBI) systems play an important role. The NBI includes several internal gas sources and has to be operated under vacuum conditions. We have developed ProVac3D, a Monte Carlo simulation code, to calculate gas dynamics and the density profiles in volumes of interest inside NBI. This enables us to elaborate our in-situ and state-of-the-art cryogenic pump design and estimate the corresponding pumping speed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗