Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTEGRAL DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

SU-E-I-21: Dosimetric Characterization and Image Quality Evaluation of the AIRO Mobile CT Scanner

Purpose: The AIRO Mobile CT system was recently introduced which overcomes the limitations from existing CT, CT fluoroscopy, and intraoperative O-arm. With an integrated table and a large diameter bore, the system is suitable for cranial, spine and trauma procedures, making it a highly versatile intraoperative imaging system. This study is to investigate radiation dose and image quality of the AIRO and compared with those from a routine CT scanner. Methods: Radiation dose was measured using a conventional 100mm pencil ionization chamber and CT polymethylmetacrylate (PMMA) body and head phantoms. Image quality was evaluated with a CATPHAN 500 phantom. Spatial resolution, low contrast resolution (CNR), Modulation Transfer Function (MTF), and Normalized Noise Power Spectrum (NNPS) were analyzed. Results: Under identical technique conditions, radiation dose (mGy/mAs) from the AIRO mobile CT system (AIRO) is higher than that from a 64 slice CT scanner. MTFs show that both Soft and Standard filters of the AIRO system lost resolution quickly compared to the Sensation 64 slice CT. With the Standard kernel, the spatial resolutions of the AIRO system are 3lp/cm and 4lp/cm for the body and head FOVs, respectively. NNPSs show low frequency noise due to ring-like artifacts. Due to a higher dose in terms of mGy/mAs at both head and body FOV, CNR of the AIRO system is higher than that of the Siemens scanner. However detectability of the low contrast objects is poorer in the AIRO due to the presence of ring artifacts in the location of the targets. Conclusion: For image guided surgery applications, the AIRO has some advantages over a routine CT scanner due to its versatility, large bore size, and acceptable image quality. Our evaluation of the physical performance helps its future improvements.

60 APPLIED LIFE SCIENCES↗

WE-AB-204-03: A Novel 3D Printed Phantom for 4D PET/CT Imaging and SIB Radiotherapy Verification

Purpose: To construct and test a 3D printed phantom designed to mimic variable PET tracer uptake seen in lung tumor volumes. To assess segmentation accuracy of sub-volumes of the phantom following 4D PET/CT scanning with ideal and patient-specific respiratory motion. To plan, deliver and verify delivery of PET-driven, gated, simultaneous integrated boost (SIB) radiotherapy plans. Methods: A set of phantoms and inserts were designed and manufactured for a realistic representation of lung cancer gated radiotherapy steps from 4D PET/CT scanning to dose delivery. A cylindrical phantom (40x 120 mm) holds inserts for PET/CT scanning. The novel 3D printed insert dedicated to 4D PET/CT mimics high PET tracer uptake in the core and lower uptake in the periphery. This insert is a variable density porous cylinder (22.12×70 mm), ABS-P430 thermoplastic, 3D printed by uPrint SE Plus with inner void volume (5.5×42 mm). The square pores (1.8×1.8 mm2 each) fill 50% of outer volume, resulting in a 2:1 SUV ratio of PET-tracer in the void volume with respect to porous volume. A matching in size cylindrical phantom is dedicated to validate gated radiotherapy. It contains eight peripheral holes matching the location of the porous part of the 3D printed insert, and one central hole. These holes accommodate adaptors for Farmer-type ion chamber and cells vials. Results: End-to-end test were performed from 4D PET/CT scanning to transferring data to the planning system and target volume delineation. 4D PET/CT scans were acquired of the phantom with different respiratory motion patterns and gating windows. A measured 2:1 18F-FDG SUV ratio between inner void and outer volume matched the 3D printed design. Conclusion: The novel 3D printed phantom mimics variable PET tracer uptake typical of tumors. Obtained 4D PET/CT scans are suitable for segmentation, treatment planning and delivery in SIB gated treatments of NSCLC.

60 APPLIED LIFE SCIENCES↗

Therapeutic Targeting of the Mitochondria Initiates Excessive Superoxide Production and Mitochondrial Depolarization Causing Decreased mtDNA Integrity

Mitochondrial dysregulation is closely associated with excessive reactive oxygen species (ROS) production. Altered redox homeostasis has been implicated in the onset of several diseases including cancer. Mitochondrial DNA (mtDNA) and proteins are particularly sensitive to ROS as they are in close proximity to the respiratory chain (RC). Mitoquinone (MitoQ), a mitochondria-targeted redox agent, selectively damages breast cancer cells possibly through damage induced via enhanced ROS production. However, the effects of MitoQ and other triphenylphosphonium (TPP+ ) conjugated agents on cancer mitochondrial homeostasis remain unknown. The primary objective of this study was to determine the impact of mitochondria-targeted agent [(MTAs) conjugated to TPP+ : mitoTEMPOL, mitoquinone and mitochromanol-acetate] on mitochondrial physiology and mtDNA integrity in breast (MDA-MB-231) and lung (H23) cancer cells. The integrity of the mtDNA was assessed by quantifying the degree of mtDNA fragmentation and copy number, as well as by measuring mitochondrial proteins essential to mtDNA stability and maintenance (TFAM, SSBP1, TWINKLE, POLG and POLRMT). Mitochondrial status was evaluated by measuring superoxide production, mitochondrial membrane depolarization, oxygen consumption, extracellular acidification and mRNA or protein levels of the RC complexes along with TCA cycle activity. In this study, we demonstrated that all investigated MTAs impair mitochondrial health and decrease mtDNA integrity in MDA-MB-231 and H23 cells. However, differences in the degree of mitochondrial damage and mtDNA degradation suggest unique properties among each MTA that may be cell line, dose and time dependent. Collectively, our study indicates the potential for TPP+ conjugated molecules to impair breast and lung cancer cells by targeting mitochondrial homeostasis.

59 BASIC BIOLOGICAL SCIENCES↗

Demonstration of the On-the-Fly Shielding Analysis Method: Spent Fuel and Waste Disposition

This report documents work performed supporting the US Department of Energy (DOE) Office of Nuclear Energy (NE) Spent Fuel and Waste Disposition (SFWD) Integrated Waste Management activities under work breakdown structure element 1.08.02.04.01, “Data and Tools Development, Validation, and Maintenance.” In particular, this report fulfills milestone M3SF-21OR020401016, “Implement on-the-fly dose analysis methodology in UNF-ST&DARDS” within work package SF-21OR02040101, “Commercial SNF Characterization - ORNL.” The Used Nuclear Fuel - Storage, Transportation & Disposal Analysis Resource and Data System (UNFST& DARDS) enables automated dose rate calculations for spent nuclear fuel (SNF) transportation packages and storage casks using a Monte Carlo radiation transport code. The explicit method uses a detailed model of the SNF system and its contents. Therefore, a dose rate calculation is required for each as-loaded transportation package or storage cask because the SNF assemblies within a canister typically have unique irradiation characteristics. An alternate method, referred to as the “on-the-fly” shielding analysis method, has been proposed that requires only a set of Monte Carlo dose rate calculations for each transportation packaging/storage cask design. The results of the Monte Carlo dose rate calculations are independent of the SNF assembly irradiation and decay characteristics. The dose rate values may then be combined with the radiation source strength of the SNF assemblies associated with a particular transportation packaging/storage cask design to determine actual dose rates. This report presents on-the-fly dose rate calculations for a representative SNF storage cask and verification of the on-the-fly dose rate calculation results by comparison with reference dose rate calculations using the explicit Monte Carlo dose rate calculation. The on-the-fly shielding analysis method was implemented in UNF-ST&DARDS. A Python program was developed to process the MAVRIC dose rate results obtained by source particle type, energy group, and fuel geometry region. A Python processor created binary files, which were saved as a special UNF-ST&DARDS library for on-the- fly shielding analyses. UNF-ST&DARDS uses the precalculated on-the-fly binary libraries generated by the Python data processor and directly executes the Python code for on-the-fly dose analysis. This Python code unzips the pre-generated binary files mentioned above, reads the data, and combines them with user-specified sources for dose and uncertainty calculations. The Python programs were verified using Excel calculations and by comparison with the values obtained with the MAVRIC post-processing utilities applied to the 3dmap files. This method can currently be used to determine dose rates for as-loaded HI-STORM FW storage casks. The UNF-ST&DARDS analysis wizard for on-the-fly shielding analysis is described in this report.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Materials-of-Construction Radiation Sensitivity for a Fission Surface Power Convertor

A fission reactor combined with a free-piston Stirling convertor is one of many credible approaches for producing electrical power in space applications. This study assumes dual-opposed free-piston Stirling engines/linear alternators that will operate nominally at 825 K hot-end and 425 K cold-end temperatures. The baseline design options, temperature profiles, and materials of construction discussed here are based on historical designs as well as modern convertors operating at lower power levels. This notional design indicates convertors primarily made of metallic components that experience minimal change in mechanical properties for fast neutron fluences less than 10(sup 20) neutrons per square centimeter. However, these radiation effects can impact the magnetic and electrical properties of metals at much lower fluences than are crucial for mechanical property integrity. Moreover, a variety of polymeric materials are also used in common free-piston Stirling designs for bonding, seals, lubrication, insulation and others. Polymers can be affected adversely by radiation doses as low as 10(sup 5) - 10(sup 10) rad. Additionally, the absorbing dose rate, radiation hardness, and the resulting effect (either hardening or softening) varies depending on the nature of the particular polymer. The classes of polymers currently used in convertor fabrication are discussed along possible substitution options. Thus, the materials of construction of prototypic Stirling convertor engines have been considered and the component materials susceptible to damage at the lowest neutron fluences have been identified.

Bowman, Cheryl L.↗

Medical Data Architecture Capabilities and Design

Mission constraints will challenge the delivery of medical care on a long-term, deep space explorationmission. This type of mission will be restricted in the availability of medical knowledge, skills, procedures and resourcesto prevent, diagnose, and treat in-flight medical events. Challenges to providing medical care are anticipated, includingresource and resupply constraints, delayed communications and no ability for medical evacuation. The Medical DataArchitecture (MDA) project will enable medical care capability in this constrained environment.The first version of thesystem, called Test Bed 1, includes capabilities for automated data collection, data storage and data retrieval to provideinformation to the Crew Medical Officer (CMO). Test Bed 1 seeks to establish a data architecture foundation and developa scalable data management system through modular design and standardized interfaces. In addition, it will demonstrateto stakeholders the potential for an improved, automated, flow of data to and from the medical system over the currentmethods employed on the International Space Station (ISS). It integrates a set of external devices, software andprocesses, and a Subjective, Objective, Assessment, and Plan (SOAP) note commonly used by clinicians. Medical datalike electrocardiogram plots, heart rate, skin temperature, respiration rate, medications taken, and more are collectedfrom devices and stored in the Electronic Medical Records (EMR) system, and reported to crew and clinician. Devicesintegrated include the Astroskin biosensor vest and IMED CARDIAX electrocardiogram (ECG) device with INEED MDECG Glove, and the NASA-developed Medical Dose Tracker application.The system is designed to be operated as astandalone system, and can be deployed in a variety of environments, from a laptop to a data center. The system isprimarily composed of open-source software tools, and is designed to be modular, so new capabilities can be added. Thesoftware components and integration methods will be discussed.

Exploration medical system↗

A Longitudinal Evaluation of Partial Lung Irradiation in Mice by Using a Dedicated Image-Guided Small Animal Irradiator

Purpose: In lung cancer radiation therapy, the dose constraints are determined mostly by healthy lung toxicity. Preclinical microirradiators are a new tool to evaluate treatment strategies closer to clinical irradiation devices. In this study, we quantified local changes in lung density symptomatic of radiation-induced lung fibrosis (RILF) after partial lung irradiation in mice by using a precision image-guided small animal irradiator integrated with micro-computed tomography (CT) imaging. Methods and Materials: C57BL/6 adult male mice (n=76) were divided into 6 groups: a control group (0 Gy) and groups irradiated with a single fraction of 4, 8, 12, 16, or 20 Gy using 5-mm circular parallel-opposed fields targeting the upper right lung. A Monte Carlo model of the small animal irradiator was used for dose calculations. Following irradiation, all mice were imaged at regular intervals over 39 weeks (10 time points total). Nonrigid deformation was used to register the initial micro-CT scan to all subsequent scans. Results: Significant differences could be observed between the 3 highest (>10 Gy) and 3 lowest irradiation (<10 Gy) dose levels. A mean difference of 120 ± 10 HU between the 0- and 20-Gy groups was observed at week 39. RILF was found to be spatially limited to the irradiated portion of the lung. Conclusions: The data suggest that the severity of RILF in partial lung irradiation compared to large field irradiation in mice for the same dose is reduced, and therefore higher doses can be tolerated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-451: Hybrid-VMAT: A Novel Technique Combining VMAT and 3D in Planning Whole Breast Radiotherapy with a Simultaneously-Integrated Boost (WBRT+SIB)

Purpose: The RTOG 1005 trial offered a hypofractionated arm in delivering WBRT+SIB. Traditionally, treatments were planned at our institution using field-in-field (FiF) tangents with a concurrent 3D conformal boost. With the availability of VMAT, it is possible that a hybrid VMAT-3D planning technique could provide another avenue in treating WBRT+SIB. Methods: A retrospective study of nine patients previously treated using RTOG 1005 guidelines was performed to compare FiF+3D plans with the hybrid technique. A combination of static tangents and partial VMAT arcs were used in base-dose optimization. The hybrid plans were optimized to deliver 4005cGy to the breast PTVeval and 4800cGy to the lumpectomy PTVeval over 15 fractions. Plans were optimized to meet the planning goals dictated by RTOG 1005. Results: Hybrid plans yielded similar coverage of breast and lumpectomy PTVs (average D95 of 4013cGy compared to 3990cGy for conventional), while reducing the volume of high dose within the breast; the average D30 and D50 for the hybrid technique were 4517cGy and 4288cGy, compared to 4704cGy and 4377cGy for conventional planning. Hybrid plans increased conformity as well, yielding CI95% values of 1.22 and 1.54 for breast and lumpectomy PTVeval volumes; in contrast, conventional plans averaged 1.49 and 2.27, respectively. The nearby organs at risk (OARs) received more low dose with the hybrid plans due to low dose spray from the partial arcs, but all hybrid plans did meet the acceptable constraints, at a minimum, from the protocol. Treatment planning time was also reduced, as plans were inversely optimized (VMAT) rather than forward optimized. Conclusion: Hybrid-VMAT could be a solution in delivering WB+SIB, as plans yield very conformal treatment plans and maintain clinical standards in OAR sparing. For treating breast cancer patients with a simultaneously-integrated boost, Hybrid-VMAT offers superiority in dosimetric conformity and planning time as compared to FIF techniques.

60 APPLIED LIFE SCIENCES↗

SU-F-18C-06: Prospective Patient Evaluation of Iterative Reconstruction in Radiation Oncology

Purpose: This work incorporates iterative reconstruction (IR) into a dose reduction study to characterize image quality metrics, delineation, and dosimetric assessment, with the goal of reducing imaging dose in Radiation Oncology. Methods: Three-dimensional noise power spectrum (NPS) analysis characterized noise magnitude/texture (120 kVp, 50–200 mAs, IR levels 1–6 yielding noise reduction of 0.89–0.55 compared to filtered backprojection (FBP)). Task-specific Modulation Transfer Functions (MTFtask) were characterized across varied subject contrasts. A prospective dose reduction study (500 to 150 mAs) was conducted for 12 patients (43 inter-fraction CTs) for high-dose rate brachytherapy. Three physicians performed qualitative image assessment between full-dose FBP (FD-FBP, 500 mAs), low-dose FBP (LD-FBP, 150–250 mAs), and low-dose IRL5-6 (LD-IR) scans for image noise, cuff/bladder interface detectability, spatial resolution, texture, and segmentation confidence. Comparisons between LD-FBP and LD-IR were conducted for the following metrics: delineation (bladder and rectum evaluated via overlap indices (OI) and Dice similarity coefficients (DSC)), noise, boundary changes, dose calculation, and digitally reconstructed radiographs (DRRs). Results: NPS showed ∼50% reduction in noise magnitude and ∼0.1 1/mm spatial frequency shift with IRL6. The largest MTFtask decrease between FBP and IR was 0.08 A.U. Qualitative patient image evaluation revealed LD-IR was equivalent or slightly worse than FD-FBP, and superior to LD-FBP for all metrics except low contrast interface and texture. The largest CT number discrepancy from FBP occurred at a bone/tissue interface using IRL6 (−1.2 ± 4.9 HU (range: −17.6 – 12.5 HU)). No significant contour differences (OIs and DSCs = 0.85 – 0.95) and dose calculation discrepancy (<0.02%) were observed. DRRs preserved anatomical detail and demonstrated <2% difference in intensity between LD-FBP and LD-IRL6. Conclusion: While phantom analysis showed slight noise texture differences with IR, patient results revealed that image quality, contouring ability, and dosimetric parameters were not adversely affected, thus support integrating IR into treatment planning. Research supported in part by a grant from Philips HealthCare.

60 APPLIED LIFE SCIENCES↗

Multi-parametric approach towards the assessment of radon and thoron progeny exposures

Conventionally, the dosimetry is carried out using radon and thoron gas concentration measurements and doses have been assigned using assumed equilibrium factors for the progeny species, which is inadequate pertaining to the variations in equilibrium factors and possibly due to significant thoron. In fact, since the true exposures depend upon the intricate mechanisms of progeny deposition in the lung, therefore an integrated approach for the assessment of progeny is essential. In this context, the recently developed deposition based progeny concentration measurement techniques (DTPS: Direct Thoron progeny sensors and DRPS: Direct Radon progeny sensors) appear to be best suited for radiological risk assessments both among occupational workers and general study populations. DTPS and DRPS consist of aluminized mylar mounted LR115 type passive detectors, which essentially detects the alpha particles emitted from the deposited progeny atoms on the detector surface. It gives direct measure of progeny activity concentrations in air. DTPS has a lower limit of detection limit of 0.1 Bq/m{sup 3} whereas that for DRPS is 1 Bq/m{sup 3}, hence are perfectly suitable for indoor environments. These DTPS and DRPS can be capped with 200-mesh type wire-screen to measure the coarse fraction of the progeny concentration and the corresponding coarse fraction deposition velocities as well as the time integrated fine fraction. DTPS and DRPS can also be lodged in an integrated sampler wherein the wire-mesh and filter-paper are arranged in an array in flow-mode, to measure the fine and coarse fraction concentration separately and simultaneously. The details are further discussed in the paper.

61 RADIATION PROTECTION AND DOSIMETRY↗

TU-AB-BRA-01: Abdominal Synthetic CT Generation in Support of Liver SBRT Dose Calculation

Purpose: To demonstrate and validate a technique for generating MRI-derived synthetic CT volumes (MRCTs) in support of adaptive liver SBRT. Methods: Under IRB approval, ten hepatocellular carcinoma patients were scanned using a single MR sequence (T1 Dixon-VIBE), yielding inherently-registered water, fat, and T1-weighted images. Air-containing voxels were identified by intensity thresholding. The envelope of the anterior vertebral bodies was segmented from the fat image by fitting a shape model to vertebral body candidate voxels, then using level sets to expand the contour outward. Fuzzy-C-Means (FCM) was then used to classify each non-air voxel in the image as fat, water, bone, or marrow. Bone and marrow only were classified within the vertebral body envelope. The MRCT was created by integrating the product of the FCM class probability with the assigned class density for each voxel. The resulting MRCTs were deformably aligned with planning CTs and 2-ARC SBRT VMAT plans were optimized on the MRCT density maps. Fluence was copied onto the CT density grids and dose recalculated. Results: The MRCTs faithfully reproduced most of the features visible in the corresponding CT image volumes, with exceptions of ribs and posterior spinous processes. The liver, vertebral bodies, kidneys, spleen and cord all had median HU differences of less than 75 between MRCT and CT images. PTV D99% values had an average 0.2% difference (standard deviation: 0.46%) between calculations on MRCT and CT density grids. The maximum difference in dose to 0.1cc of the PTV was 0.25% (std:0.49%). OAR dose differences were similarly small (mean:0.03Gy, std:0.26Gy). The largest normal tissue complication percentage (NTCP) difference was 1.48% (mean:0.06%, std:0.54%). Conclusions: MRCTs from a single abdominal imaging sequence are promising for use in SBRT dose calculation. Future work will focus on extending models to better define bones in the upper abdomen. Supported by NIHR01EB016079 and NIH1L30CA199594-01.

60 APPLIED LIFE SCIENCES↗

Atomistic‐Level Effects of Noncovalent Interactions and Crystalline Packing for Organic Material Structural Integrity upon Exposure to Gamma Radiation

Developing an atomistic understanding of ionizing radiation induced changes to organic materials is necessary for intentional design of greener and more sustainable materials for radiation shielding and detection. Cocrystals are promising for these purposes, but a detailed understanding of how the specific intermolecular interactions within the lattice upon exposure to radiation affect the structural stability of the organic crystalline material is unknown. This study evaluates atomistic-level effects of γ radiation on both single- and multicomponent organic crystalline materials and how specific noncovalent interactions and packing within the crystalline lattice enhance structural stability. Dose studies were performed on all crystalline systems and evaluated via experimental and computational methods. Changes in crystallinity were evaluated by p-XRD and free radical formation was analyzed via EPR spectroscopy. Type of intermolecular interactions and packing within the crystal lattice was delineated and related to the specific free radical species formed and the structural integrity of each material. Periodic DFT and HOMO-LUMO surface mapping calculations provided atomistic-level identifications of the most probable sites for the radicals formed upon exposure to γ radiation and relate intermolecular interactions and molecular packing within the crystalline lattice to experimental results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Initial Feasibility Assessment and Broader Strategy Development for Fiber Integration via Advanced Manufacturing

Structural health monitoring is critical for ensuring the operational safety and cost-competitiveness of the developing advanced reactor designs. The extreme operational envelopes of these advanced architectures, having operating temperatures ranging 400°C–1,000°C and heightened displacement damage doses, render conventional commercially available piezoelectric transducers and resistive strain gauges unviable. Optical fiber sensors present an attractive solution for advanced radiation-hardened instrumentation due to their high thermal stability and distributed sensing capabilities. However, their deployment in embedded applications can be hindered by the severe thermomechanical strain driven by the coefficient of thermal expansion mismatch between fused silica glass and structural metal alloys like stainless steel (e.g., SS316L).

36 MATERIALS SCIENCE↗

Self-Recovery Experiments in Extreme Environments Using a Field Programmable Transistor Array

Temperature and radiation tolerant electronics, as well as long life survivability are key capabilities required for future NASA missions. Current approaches to electronics for extreme environments focus on component level robustness and hardening. However, current technology can only ensure very limited lifetime in extreme environments. This paper describes novel experiments that allow adaptive in-situ circuit redesign/reconfiguration during operation in extreme temperature and radiation environments. This technology would complement material/device advancements and increase the mission capability to survive harsh environments. The approach is demonstrated on a mixed-signal programmable chip (FPTA-2), which recovers functionality for temperatures until 28 C and with total radiation dose up to 250kRad.

space vehicle electronics↗

Dose Rate Analysis of As-Loaded Spent Nuclear Fuel Casks - Paper 97

Used Nuclear Fuel Storage, Transportation and Disposal Analysis Resource and Data System (UNF-ST[and]DARDS) is a comprehensive data and calculation capability for UNF safety assessments currently being developed at Oak Ridge National Laboratory through a collaborative effort of multiple national laboratories and industry participants. The purpose of UNF-ST[and]DARDS is to provide a unified domestic UNF system of data and analysis capabilities in support of U.S. Department of Energy waste management and fuel cycle-related objectives. UNF-ST[and]DARDS is designed to provide safety assessments for UNF storage, transportation, and disposal systems based on actual characteristics of the as-loaded UNF (e.g., fuel assembly burnup, enrichment, decay time, cladding integrity, etc.). The cask-specific safety evaluations allow quantification of realistic safety margins and conditions and provide the technical basis for addressing concerns related to potential fuel failure (e.g., for high-burnup fuel). This paper describes the UNF-ST[and]DARDS methodology for calculating radiation dose rates for U.S. Nuclear Regulatory Commission (NRC) licensed casks based on actual UNF canister contents. Realistic dose rate values based on actual canister contents may be used in place of bounding dose rate values to support development of repackaging operations procedures, evaluation of radiation-related transportation risks, and communication with stakeholders. UNF-ST[and]DARDS capabilities have been recently expanded to include automated radiation source term calculations and dose rate analyses of as-loaded transportation casks. This unique capability determines realistic dose rate values based on actual canister UNF contents that may be used in radiation dose assessments to demonstrate safe transportation of commercial UNF. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Toward Submillimeter Accuracy in the Management of Intrafraction Motion: The Integration of Real-Time Internal Position Monitoring and Multileaf Collimator Target Tracking

Purpose: We report on an integrated system for real-time adaptive radiation delivery to moving tumors. The system combines two promising technologies-three-dimensional internal position monitoring using implanted electromagnetically excitable transponders and corresponding real-time beam adaptation using a dynamic multileaf collimator (DMLC). Methods and Materials: In a multi-institutional academic and industrial collaboration, a research version of the Calypso position monitoring system was integrated with a DMLC-based four-dimensional intensity-modulated radiotherapy delivery system using a Varian 120-leaf multileaf collimator (MLC). Two important determinants of system performance-latency (i.e., elapsed time between target motion and MLC response) and geometric accuracy-were investigated. Latency was quantified by acquiring continuous megavoltage X-ray images of a moving phantom (with embedded transponders) that was tracked in real time by a circular MLC field. The latency value was input into a motion prediction algorithm within the DMLC tracking system. Geometric accuracy was calculated as the root-mean-square positional error between the target and the centroid of the MLC aperture for patient-derived three-dimensional motion trajectories comprising two lung tumor traces and one prostate trace. Results: System latency was determined to be approximately 220 milliseconds. Tracking accuracy was observed to be sub-2 mm for the respiratory motion traces and sub-1 mm for prostate motion. Conclusion: We have developed and characterized a research version of a novel four-dimensional delivery system that integrates nonionizing radiation-based internal position monitoring and accurate real-time DMLC-based beam adaptation. This system represents a significant step toward achieving the eventual goal of geometrically ideal dose delivery to moving tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Role of Radiation Therapy in Patients With Relapsed or Refractory Hodgkin Lymphoma: Guidelines From the International Lymphoma Radiation Oncology Group

Relapsed and refractory Hodgkin lymphoma (HL) challenges clinicians to devise treatment strategies that are effective and safe. This problem is particularly prominent in an era when de-escalation trials are designed to minimize therapeutic toxicities in both early- and advanced-stage disease. Radiation therapy is the single most effective treatment modality for HL, and its integration into salvage regimens, or its independent use in select patients, must be understood to maximize our success in treating these patients. The complexity of treating relapsed or refractory HL derives from the spectrum of primary treatment approaches currently in use that creates heterogeneity in both treatment exposure and the potential toxicities of salvage therapy. Patients can have relapsed or refractory disease after limited or aggressive primary therapy (with or without radiation therapy), at early or delayed time points, with limited or extensive disease volumes, and with varying degrees of residual morbidity from primary therapy. Their response to salvage systemic therapy can be partial or complete, and the use of consolidative stem cell transplantation is variably applied. New biologics and immunotherapeutic approaches have broadened but also complicated salvage treatment approaches. Through all of this, radiation therapy remains an integral component of treatment for many patients, but it must be used effectively and judiciously. The purpose of this review is to describe the different treatment scenarios and provide guidance for radiation dose, volume, and timing in patients with relapsed or refractory HL.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correlation between infrared spectra features and coverage of different adsorption sites for the NO/Pd(111) system

This study investigates the adsorption of nitric oxide (NO) on Pd(111) surfaces at 200 K using infrared reflection absorption spectroscopy (IRRAS). Peak positions and areas are used as proxies for tracking coverage of different species, serving as groundwork for in-situ experiments that need real-time tracking of surface species. Here, we derived a mathematical model correlating NO coverage with dose, consistent with the Molecular Langmuir Model. Distinct correlations are observed between coverage and spectral features (peak position and peak area for the NO vibration): at lower coverages (θ<0.6), the total integrated peak areas are linearly corelated to coverage; at higher coverages (θ>0.6), the peak center for a compressed-hollow site becomes the primary coverage indicator, showing a linear relationship between wavenumber and coverage. Note that this study addresses coverages below saturation. These findings refine our understanding of NO adsorption and establish a foundation for real-time in situ transient kinetics studies of chemical reactions involving NO on Pd(111).

25 ENERGY STORAGE↗