Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Iraq/Afghanistan war lung injury reflects burn pits exposure

This descriptive case series retrospectively reviewed medical records from thirty-one previously healthy, war-fighting veterans who self-reported exposure to airborne hazards while serving in Iraq and Afghanistan between 2003 and the present. They all noted new-onset dyspnea, which began during deployment or as a military contractor. Twenty-one subjects underwent non-invasive pulmonary diagnostic testing, including maximum expiratory pressure (MEP) and impulse oscillometry (IOS). In addition, five soldiers received a lung biopsy; tissue results were compared to a previously published sample from a soldier in our Iraq Afghanistan War Lung Injury database and others in our database with similar exposures, including burn pits. We also reviewed civilian control samples (5) from the Stony Brook University database. Military personnel were referred to our International Center of Excellence in Deployment Health and Medical Geosciences, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell under the auspices of Northwell IRB: 17-0140-FIMR Feinstein Institution for Medical Research “Clinicopathologic characteristics of Iraq Afghanistan War Lung Injury.” We retrospectively examined medical records, including exposure data, radiologic imaging, and non-invasive pulmonary function testing (MGC Diagnostic Platinum Elite Plethysmograph) using the American Thoracic Society (ATS) standard interpretation based on Morgan et al., and for a limited cohort, biopsy data. Lung tissue, when available, was examined for carbonaceous particles, polycyclic aromatic hydrocarbons (Raman spectroscopy), metals, titanium connected to iron (Brookhaven National Laboratory, National Synchrotron Light Source II, Beamline 5-ID), oxidized metals, combustion temperature, inflammatory cell accumulation and fibrosis, neutrophil extracellular traps, Sirius red, Prussian Blue, as well as polarizable crystals/particulate matter/dust. Among twenty-one previously healthy, deployable soldiers with non-invasive pulmonary diagnostic tests, post-deployment, all had severely decreased MEP values, averaging 42% predicted. These same patients concurrently demonstrated abnormal airways reactance (X5Hz) and peripheral/distal airways resistance (D5–D20%) via IOS, averaging – 1369% and 23% predicted, respectively. These tests support the concept of airways hyperresponsiveness and distal airways narrowing, respectively. Among the five soldiers biopsied, all had constrictive bronchiolitis. We detected the presence of polycyclic aromatic hydrocarbons (PAH)—which are products of incomplete combustion—in the lung tissue of all five warfighters. All also had detectable titanium and iron in the lungs. Metals were all oxidized, supporting the concept of inhaling burned metals. Combustion temperature was consistent with that of burned petrol rather than higher temperatures noted with cigarettes. All were nonsmokers. Neutrophil extracellular traps were reported in two biopsies. Compared to our prior biopsies in our Middle East deployment database, these histopathologic results are similar, since all database biopsies have constrictive bronchiolitis, one has lung fibrosis with titanium bound to iron in fixed mathematical ratios of 1:7 and demonstrated polarizable crystals. These results, particularly constrictive bronchiolitis and polarizable crystals, support the prior data of King et al. (N. Engl. J. Med. 365:222–230, 2011) Soldiers in this cohort deployed to Iraq and Afghanistan since 2003, with exposure to airborne hazards, including sandstorms, burn pits, and improvised explosive devices, are at high risk for developing chronic clinical respiratory problems, including: (1) reduction in respiratory muscle strength; (2) airways hyperresponsiveness; and (3) distal airway narrowing, which may be associated with histopathologic evidence of lung damage, reflecting inhalation of burned particles from burn pits along with particulate matter/dust. Non-invasive pulmonary diagnostic tests are a predictor of burn pit-induced lung injury

36 MATERIALS SCIENCE↗

Rapid and efficient ambient temperature X-ray crystal structure determination at Turkish Light Source

High-resolution biomacromolecular structure determination is essential to better understand protein function and dynamics. Serial crystallography is an emerging structural biology technique which has fundamental limitations due to either sample volume requirements or immediate access to the competitive X-ray beamtime. Obtaining a high volume of well-diffracting, sufficient-size crystals while mitigating radiation damage remains a critical bottleneck of serial crystallography. As an alternative, we introduce the plate-reader module adapted for using a 72-well Terasaki plate for biomacromolecule structure determination at a convenience of a home X-ray source. We also present the first ambient temperature lysozyme structure determined at the Turkish light source (Turkish DeLight). The complete dataset was collected in 18.5 min with resolution extending to 2.39 Å and 100% completeness. Combined with our previous cryogenic structure (PDB ID: 7Y6A), the ambient temperature structure provides invaluable information about the structural dynamics of the lysozyme. Turkish DeLight provides robust and rapid ambient temperature biomacromolecular structure determination with limited radiation damage.

59 BASIC BIOLOGICAL SCIENCES↗

Targeting Enterococcus faecalis HMG-CoA reductase with a non-statin inhibitor

HMG-CoA reductase (HMGR), a rate-limiting enzyme of the mevalonate pathway in Gram-positive pathogenic bacteria, is an attractive target for development of novel antibiotics. In this study, we report the crystal structures of HMGR from Enterococcus faecalis (efHMGR) in the apo and liganded forms, highlighting several unique features of this enzyme. Statins, which inhibit the human enzyme with nanomolar affinity, perform poorly against the bacterial HMGR homologs. We also report a potent competitive inhibitor (Chembridge2 ID 7828315 or compound 315) of the efHMGR enzyme identified by a high-throughput, in-vitro screening. The X-ray crystal structure of efHMGR in complex with 315 was determined to 1.27 Å resolution revealing that the inhibitor occupies the mevalonate-binding site and interacts with several key active site residues conserved among bacterial homologs. Importantly, 315 does not inhibit the human HMGR. Our identification of a selective, non-statin inhibitor of bacterial HMG-CoA reductases will be instrumental in lead optimization and development of novel antibacterial drug candidates.

59 BASIC BIOLOGICAL SCIENCES↗

Mass action model of solution activity via speciation by solvation and ion pairing equilibria

Abstract Solutes and their concentrations influence many natural and anthropogenic solution processes. Electrolyte and solution models are used to quantify and predict such behavior. Here we present a mechanistic solution model based on mass action equilibria. Solvation and ion pairing are used to model speciated solute and solvent concentrations such that they correlate to a solution’s vapor pressure (solvent activity) according to Raoult’s law from dilute conditions to saturation. This model introduces a hydration equilibrium constant ( K ha ) that is used with either an ion dissociation constant ( K id ) or a hydration modifier ( m ) with an experimentally determined ion dissociation constant, as adjustable parameters to fit vapor–liquid equilibrium data. The modeled solvation equilibria are accompanied by molecular dynamics (MD) studies that support a decline in the observed degree of solvation with increased concentration. MD calculations indicate this finding is a combination of a solvent that solvates multiple solutes, and changes in a solute’s solvation sphere, with the dominant factor changing with concentration. This speciation-based solution model is lateral to established electrostatics-based electrolyte theories. With its basis in mass action, the model can directly relate experimental data to the modeled solute and solvent speciated concentrations and structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Long-read, whole-genome shotgun sequence data for five model organisms

Single molecule, real-time (SMRT) sequencing from Pacific Biosciences is increasingly used in many areas of biological research including de novo genome assembly, structural-variant identification, haplotype phasing, mRNA isoform discovery, and base-modification analyses. High-quality, public datasets of SMRT sequences can spur development of analytic tools that can accommodate unique characteristics of SMRT data (long read lengths, lack of GC or amplification bias, and a random error profile leading to high consensus accuracy). In this paper, we describe eight high-coverage SMRT sequence datasets from five organisms (Escherichia coli, Saccharomyces cerevisiae, Neurospora crassa, Arabidopsis thaliana, and Drosophila melanogaster) that have been publicly released to the general scientific community (NCBI Sequence Read Archive ID SRP040522). Data were generated using two sequencing chemistries (P4C2 and P5C3) on the PacBio RS II instrument. The datasets reported here can be used without restriction by the research community to generate whole-genome assemblies, test new algorithms, investigate genome structure and evolution, and identify base modifications in some of the most widely-studied model systems in biological research.

59 BASIC BIOLOGICAL SCIENCES↗

Picosecond x-ray absorption measurements of the ligand substitution dynamics of Fe(CO){sub 5} in ethanol.

Ultrafast X-ray absorption near edge spectroscopy has been carried out for photo excited iron pentacarbonyl in ethanol with 2 picosecond resolution. A temporal resolution limited dissociation process was observed, followed by the formation of the mono-substituted complex Fe(CO){sub 4}EtOH within a few tens of picoseconds. The measurements have been carried out with a newly developed X-ray absorption instrument at station 7 ID-C of the Advanced Photon Source. The results show that single picosecond temporal resolution can be achieved at a synchrotron beam line.

43 PARTICLE ACCELERATORS↗

Consequences of the failure of equipartition for the p – V behavior of liquid water and the hydration free energy components of a small protein

Earlier we showed that in the molecular dynamics simulation of a rigid model of water it is necessary to use an integration time-step δ t ≤ 0.5 fs to ensure equipartition between translational and rotational modes. Here we extend that study in the NVT ensemble to NpT conditions and to an aqueous protein. We study neat liquid water with the rigid, SPC/E model and the protein BBA (PDB ID: 1FME) solvated in the rigid, TIP3P model. We examine integration time-steps ranging from 0.5 fs to 4.0 fs for various thermostat plus barostat combinations. We find that a small δ t is necessary to ensure consistent prediction of the simulation volume. Hydrogen mass repartitioning alleviates the problem somewhat, but is ineffective for the typical time-step used with this approach. The compressibility, a measure of volume fluctuations, and the dielectric constant, a measure of dipole moment fluctuations, are also seen to be sensitive to δ t . Using the mean volume estimated from the NpT simulation, we examine the electrostatic and van der Waals contribution to the hydration free energy of the protein in the NVT ensemble. These contributions are also sensitive to δ t . In going from δ t = 2 fs to δ t = 0.5 fs, the change in the net electrostatic plus van der Waals contribution to the hydration of BBA is already in excess of the folding free energy reported for this protein.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Secure Command Line Solution for Token-based Authentication

The WLCG is modernizing its security infrastructure, replacing X.509 client authentication with the newer industry standard of JSON Web Tokens (JWTs) obtained through the Open ID Connect (OIDC) protocol. There is a wide variety of software available using the standards, but most of it is for Web browser-based applications and doesn’t adapt well to the command line-based software used heavily in High Throughput Computing (HTC). OIDC command line client software did exist, but it did not meet our requirements for security and convenience. This paper discusses a command line solution we have made based on the popular existing secrets management software from Hashicorp called vault. We made a package called htvault-config to easily configure a vault service and another called htgettoken to be the vault client. In addition, we have integrated use of the tools into the HTCondor workload management system, although they also work well independent of HTCondor. All of the software is open source, under active development, and ready for use.

Dykstra, Dave↗

Label-based Virtual Directories In dCache

Traditional filesystems organize data in directories. These directories are typically a collection of files whose grouping is based on a single criterion, e.g., the starting date of an experiment, experiment name, beamline ID, measurement device, or instrument. However, each file in a directory can belong to several logical groups, such as a special event type, experiment condition, or a part of a selected dataset. dCache is a storage system developed to store large amounts of scientific data, used by many HEP and Photon Science experiments. With recent developments in dCache, we have introduced a concept of file tagging, which dynamically groups files with the same label into virtual directories. The file labels can be added, removed, renamed, and deleted through the admin interface or via REST API. The files in virtual directories are exposed through all protocols supported by dCache. This contribution will describe the details of the implementation for file tagging in dCache and present our future development plans on automatic metadata extractions, a feature that will significantly simplify data management. Additionally, we are exploring the future use of virtual directories as a way to translate scientific data catalogs into filesystem views for direct data analysis.

Sahakyan, Marina [DESY]↗

Fabrication, characterization, and the rectifying properties of the interfacial structural controlled LaSrMnO-Si heterojunctions

The La{sub 0.9}Sr{sub 0.1}MnO{sub 3}/Si p-n junctions with optimized rectifying properties were synthesized using radio frequency magnetron sputtering followed by an in situ annealing process at a series of temperatures. The thickness of the SiO{sub x} barrier layer d determines the rectifying properties of the heterojunctions by Id{sup 3}=constant (I is the rectifying current). The dead layer was determined to act as a semiconductor layer in the conduction process. The annealed samples show Mn{sup 4+} rich interface which correlated closely to the electrical transportation properties of the heterostructures. Lowering the annealing temperature, the electric sensitivity of the heterojunction can be significantly enhanced by simply tuning the thickness of the barrier layer.

36 MATERIALS SCIENCE↗

Lunar Nuclear Power Plant With Solid Core Reactor, Heatpipes and Thermoelectric Conversion

This is a lunar nuclear power plant with the advantages of minimum mass, with no moving parts, no pumped liquid coolant, a solid metal rugged core, with no single point of failure. The electrical output is 100 kilowatts with a 500 kilowatt thermal reactor. The thermoelectric converters surround the potassium heatpipes from the core and water heatpipes surround the converter and connect to the radiator. The solid core reactor is made from HT9 alloy. The fuel is uranium oxide with 90% enrichment. The thermoelectric converter is bonded to the outside of the 1.10 inch ID heat pipe and is 30 inches long. The thermoelectric couple is Si/SiGe-Si/SiC Quantum Well with over 20% efficiency with an 890 K hot side and a 490 K cold side and produces 625 Watts. 176 converters produce 110 kWe. With less than 10% loss in controls this yields 100 kWe for use. The cylindrical thermoelectric converter is designed and fabricated by HIPing to keep brittle materials in compression and to ensure conductivity. The solid core is fabricated by machining the heatpipe tubes with 6 grooves that are diffusion bonded together by HIPing to form the fuel tubes. The maximum temperature of the heat pipes is 940 K and the return flow temperature is 890 K. The reactor core is hexagonal shaped, 61 cm. wide and 76.2 cm high with 12 rotating control drums surrounding it. There is shielding to protect components and human habitation. The radiator is daisy shaped at 45 degrees with each petal 5.5 meters long. The design life is ten years.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Physics and Performance Evaluation Group

We summarize the objectives and results of the ''international scoping study of a future neutrino factory and superbeam facility'' (ISS) physics working group. Furthermore, we discuss how the ISS study should develop into a neutrino factory design study (IDS-NF) from the point of view of physics and performance evaluation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ISS/IDS Detector Study

This article summarises the results obtained by the detector working group of the 'International Scooping Study' (ISS) of a future neutrino oscillations facility. Special emphasis is put on far detectors, for which some of the main issues are identified. A detector R and D strategy in the context of the 'International Design Study' (IDS) for a neutrino factory is also presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigation of numerical thermalization in particle-in-cell simulations

Particle-in-cell (PIC) is a widely used method for plasma modelling. Like any other method it represents only an approximation to real plasma. This fact implies the possibility for development of some parasitic effects in the simulation. It is very important to know the nature of these effects and how they affect the simulation. In this article we investigate one of them known as numerical thermalization (maxwellization) which means the artificial increased rate in which the velocity distribution function of particles relaxes toward Maxwellian. We used a Id model of homogenous plasma to measure how the thermalization time is affected by number of particles per Debye length N{sub D}. Recently some works show that explicit introduction of collisions to PIC method may have negative side-effects to the simulation, so we have also studied this phenomena.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Assessment of a 1-D, Multi-colour X-ray Imaging System for the MAST ST

A design of the ID soft x-ray imaging system for future experiments at the Mega-Amper Spherical Tokamak (MAST) and results of the numerical simulations based on initial assumptions about the state of the tokamak plasma as well as the parameters and geometry of the detection system are presented. The imaging system consists of a set of arrays of detectors, pinholes and filters attached to each set, together with suitable readout electronics. In simulations, an array of semiconductor detectors is compared with an array of scintillator-photomultiplier combination. The measuring system is assumed to operate in the range 1-10 keV. In addition to the 1-D imaging of x-ray emission, the system gives the possibility to measure the energy slope of x-ray spectrum and thus the electron temperature of plasma.An extended numerical code simulates the imaging system for various parameters of plasma (spatial profiles of the plasma density and temperature) generated at the tokamak and for different configurations of the detection system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Ion Doppler Spectrometer Instrument for Ion Temperature and Flow Measurements on SSPX

A high-resolution ion Doppler spectrometer has been installed on the Sustained Spheromak Plasma Experiment to measure ion temperatures and plasma flow. The system is composed of a 1 meter focal length Czerny-Turner spectrometer with diffraction grating line density of 2400 lines/mm, which allows for first order spectra between 300 and 600 nm. A 16-channel photomultiplier tube detection assembly combined with output coupling optics provides a spectral resolution of 0.0126 nm per channel. We calculate in some detail the mapping of curved slit images onto the linear detector array elements. This is important in determining wavelength resolution and setting the optimum vertical extent of the slit. Also, because of the small wavelength window of the IDS, a miniature fiber optic survey spectrometer sensitive to a wavelength range 200 to 1100 nm and having resolution 0.2 nm, is used to obtain a time-integrated spectrum for each shot to verify specific impurity line radiation. Several measurements validate the systems operation. Doppler broadening of C III 464.72 nm line in the plasma shows time-resolved ion temperatures up to 250 eV for hydrogen discharges, which is consistent with neutral particle energy analyzer measurements. Flow measurements show a sub-Alfvenic plasma flow ranging from 5 to 45 km/s for helium discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In-situ X-ray structure measurements on aerodynamically levitated high temperature liquids

High energy, high flux X-ray sources enable new measurements of liquid and amorphous materials in extreme conditions. Aerodynamic levitation in combination with laser beam heating can be used to access high purity and non-equilibrium liquids at temperatures up to 3000 K. In this work, a small aerodynamic levitator was integrated with high energy beamline 11 ID-C at the Advanced Photon Source. Scattered X-rays were detected with a Mar345 image plate. The experiments investigated a series of binary in the CaO-Al{sub 2}O{sub 3}, MgO-SiO{sub 2}, SiO{sub 2}-Al{sub 2}O{sub 3} metal oxide compositions and pure SiO{sub 2}. The results show that the liquids exhibit large changes in structure when the predominant network former is diluted. Measurements on glasses with the same compositions as the liquids suggest that significant structural rearrangement consistent with a fragile-strong transition occurs in these reluctant glass forming liquids as they vitrify.

36 MATERIALS SCIENCE↗

Spectroscopic measurements of temperature and plasma impurity concentration during magnetic reconnection at the Swarthmore Spheromak Experiment

Electron temperature measurements during counterhelicity spheromak merging studies at the Swarthmore Spheromak Experiment (SSX) [M. R. Brown, Phys. Plasmas 6, 1717 (1999)] are presented. VUV monochromator measurements of impurity emission lines are compared with model spectra produced by the non-LTE excitation kinematics code PRISMSPECT[J. J. MacFarlane et al., in Proceedings of the Third Conference on Inertial Fusion Science and Applications (2004)] to yield the electron temperature in the plasma with 1 {mu}s time resolution. Average T{sub e} is seen to increase from 12 to 19 eV during spheromak merging. Average C III ion temperature, measured with a new ion Doppler spectrometer (IDS) [C. D. Cothran et al., Rev. Sci. Instrum. 77, 063504 (2006)], likewise rises during spheromak merging, peaking at {approx}22 eV, but a similar increase in T{sub i} is seen during single spheromak discharges with no merging. The VUV emission line measurements are also used to constrain the concentrations of various impurities in the SSX plasma, which are dominated by carbon, but include some oxygen and nitrogen. A burst of soft x-ray emission is seen during reconnection with a new four-channel detector (SXR). There is evidence for spectral changes in the soft x-ray emission as reconnection progresses, although our single-temperature equilibrium spectral models are not able to provide adequate fits to all the SXR data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗