Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Decarbonizing Industrial Heat and Electricity Applications Using Advanced Nuclear Energy

Idaho National Laboratory (INL) is investigating the technical pathways to assist industrial heat and electricity users to meet their decarbonization goals through integration with advanced nuclear power plants (NPPs). This project will deliver a library of process models and accompanying documents that guide specific industries in choosing potential nuclear technologies based on their needs. Considerations in providing this guidance include specific hazards from the industrial facility, heat transport requirements and associated technologies, and feasibility with site-specific demand profiles. The library of facility process models will be based on real data from industrial facilities in the United States. The industrial processes will be identified in this project based on the following: (1) operational heat characteristics that nuclear systems can provide, (2) sufficient energy requirements to merit the capital investment for nuclear plant construction, and (3) environmental benefits of replacing existing energy production with carbon-free nuclear power. Other decarbonization opportunities considered are the addition of nuclear-powered electrolysis processes or high-temperature electric heating where the thermal requirements exceed nuclear generation conditions. In addition to assessing the technical feasibility, INL is evaluating the impact of hazards introduced by the industrial facilities on the siting requirements of advanced NPPs. Site characterization of an industrial plant is essential to determine the feasibility and suitable integration methods for each industry. The assessment of siting and technical data will reveal opportunities for a single-use nuclear integration as well as integration of multiple industrial facilities with a single NPP.

02 PETROLEUM↗

Advancing Geothermal Research: Fiscal Year 2025 Accomplishments Report

This is a summary of geothermal work done at the National Renewable Energy Laboratory (NREL) in Fiscal Year 2025. This year brought increased attention to the geothermal industry and NREL's geothermal research portfolio. With more than 70 active projects, NREL research spanned the areas of resource exploration and characterization; conventional and next-generation geothermal technologies; subsurface thermal energy storage; heating and cooling; co-production of geothermal with critical minerals and oil and gas; modeling and analysis leveraging expertise in data science and machine learning; and more.

15 GEOTHERMAL ENERGY↗

Advancing Geothermal Research: Fiscal Year 2025 Accomplishments Report

This is a summary of geothermal work done at the National Laboratory of the Rockies in Fiscal Year 2025. This year brought increased attention to the geothermal industry and NLR's geothermal research portfolio. With more than 70 active projects, NLR research spanned the areas of resource exploration and characterization; conventional and next-generation geothermal technologies; subsurface thermal energy storage; heating and cooling; co-production of geothermal with critical minerals and oil and gas; modeling and analysis leveraging expertise in data science and machine learning; and more.

15 GEOTHERMAL ENERGY↗

Optimizing design and dispatch of a renewable energy system with combined heat and power

We embellish a mixed-integer program that prescribes a set of renewable energy, conventional generation, and storage technologies to procure, along with a corresponding dispatch strategy. Specifically, we add combined heat and power to this set. The model minimizes fixed and operational costs less incentives for the use of various technologies, subject to a series of component interoperability and system-wide constraints. The resulting mixed-integer linear program contains hundreds of thousands of variables and constraints. We demonstrate how to efficiently formulate and solve the corresponding instances such that we produce near-optimal solutions in minutes. A previous rendition of the model required hours of solution time for the same instances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Evaluation of a Prototype Moving Packed-Bed Particle/sCO 2 Heat Exchanger

Particle heat exchangers are a critical enabling technology for next generation concentrating solar power (CSP) plants that use supercritical carbon dioxide (sCO 2 ) as a working fluid. This report covers the design, manufacturing and testing of a prototype particle-to-sCO 2 heat exchanger targeting thermal performance levels required to meet commercial scale cost targets. In addition, the the design and assembly of integrated particle and sCO 2 flow loops for heat exchanger performance testing are detailed. The prototype heat exchanger was tested to particle inlet temperatures of 500 °C at 17 MPa which resulted in overall heat transfer coefficients of approximately 300 W/m 2 -K at the design point and cases using high approach temperature with peak values as high as 400 W/m 2 -K

14 SOLAR ENERGY↗

Completion of Level 2 FY25 milestone #9193

Future laser facilities, such as the National Ignition Facility (NIF) Enhanced Yield Capability (EYC) upgrade, or entirely new facilities (often referred to as a “Next Generation” laser facilities), will drive inertial confinement fusion (ICF) targets with higher laser energies and total laser drive powers than those currently accessible at the NIF. One of the primary concerns is the loss of driver energy or symmetry control due to unwanted laser-plasma interactions (LPIs) that can backscatter, divert, or otherwise redistribute laser drive in a deleterious manner, or pre-heat the capsule ablator or fuel through the generation of hot electrons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low Cost Glass-Ceramic Matrix Composite Heat Exchanger

As part of ARPA-E’s High Intensity Thermal Exchange through Materials and Manufacturing Processes (HITEMMP) program, this project sought to develop novel heat exchanger (HX) capabilities to enable efficient and power dense power generation cycles. This class of HX comes under the category of ceramic/composite materials with the higher temperature goal in the program of ≥1100 °C inlet temperature operation. The enabling capability of this effort is the use of glass-ceramic matrix composite (GCMC) material which provides the high temperature durability of a ceramic, the flaw tolerance of a composite, a significantly faster and lower cost manufacturing process than conventional matrix CMCs and very low porosity levels < 0.5%. For thin-walled HX structures and the need to minimize leakage, the low porosity differentiator is particularly important. RTRC has prior experience with this material system and in the current project advanced the component design and manufacturing methods into new territory to produce features required for effective heat exchange under high pressures. In this approach, silicon carbide fiber is fabricated into a fiber preform using various textile processes. Graphite tooling is used both during the build-up of the fiber preform (interior tooling) and after the fiber preform has been completed (exterior tooling). This tooling assembly is heated to high temperature in an environment that has been evacuated and backfilled with inert gas. A reservoir of specialty glass is present and once the desired temperature has been reached to achieve the desired glass viscosity, an actuator distributes the glass throughout the fiber preform using passageways which are part of the tooling design in a process known as glass transfer molding. After the tooling has been removed, the composite is heat treated to convert the amorphous glass to a crystalline ceramic, providing improved properties. The project was divided into three phases focusing on the following: 1) 10 kW HX design and coupon-level tube sheet fabrication, 2) 10 kW HX fabrication, 3) 50 kW HX fabrication. During Budget Period 1 (BP1), additional risks were encountered and the need for additional funds was agreed upon by ARPA-E program leadership. Due to a variety of factors, the contract modification required nominally 18 months to execute at which time the HITEMMP program was effectively concluding. Because of this and the time that would be required to perform BP2 tasks, it was decided to conclude the project at the end of BP1. During the design of the 10 kW HX, manufacturing constraints were learned and incorporated, leading to a revised configuration for the fiber preform and HX. Heat exchange and pressure drop predictions also played a role in modifying the original design concept to be a higher aspect ratio shell-and-tube HX, simplifying the manufacturing process and improving the heat exchanger performance. Good gravimetric and volumetric thermal power densities of 11.2 kW/kg and 10,200 kW/m3 for the entire HX were projected that involved thermo-structural Finite Element Analysis to determine the structural mass needed for the high operation pressures of 250 bar cold inlet and 80 bar hot inlet. Fiber preforms using textile processes were produced for multiple headered tube sheets. Additional challenges were encountered during the glass transfer molding step for which solutions were identified, but programmatics did not allow them to be implemented in BP1. While complete HX test articles were not fabricated, the benefits of this GCMC material for a variety of high temperature applications remain.

30 DIRECT ENERGY CONVERSION↗

The microstructure of a selective laser melting (SLM)-fabricated NiTi shape memory alloy with superior tensile property and shape memory recoverability

A selective laser melting (SLM)-fabricated NiTi with superior tensile property and shape memory recoverability was obtained by using a unique stripe rotation scanning strategy. Here, the alloy characteristics, formation mechanisms and evolution in terms of twins, dislocations and precipitations of the alloy were systematically studied. Compared to the conventional smelting-followed-by-machining, the SLM fabrication process involves rapid solidification and repeated heating, which confer distinctive characteristics to the microstructures of SLM-fabricated NiTi alloys. Rapid solidification promotes the formation of a supersaturation solid solution matrix containing a high concentration vacancies, which in turn aggregate to generate a high density of dislocations. During subsequent repeated heating stages, these dislocations occur thermal motion along three directions of <001 > , <111> and <110 >, leading to the formation of thermal kinks, helical dislocations and wave morphology. Simultaneously, precipitated particles Ti 3 Ni 4 repeatedly nucleate and heterogeneous grow with the movement of dislocation. Such precipitation behavior, termed repeated precipitation, has not been previously reported in the conventional NiTi alloys, suggesting that it could be a unique characteristic of such alloy. After martensitic transformation, only two twins, {1 1¯ 1} type I twin and compound twin, are detected. The twinning lamellae of these two twins, where precipitation and dislocation pile-ups exist, often have uneven thickness and chaotic arrangement. Besides, the unique self-accommodated microstructures, such as secondary {1 1¯ 1} type I twin and compound twin with “herring-bone’’ lamellae, which often appear in the deformed or nanocrystalline NiTi, can also be observed. These unique microstructures may confer the distinctive properties to the SLM-fabricated NiTi.

36 MATERIALS SCIENCE↗

The accuracy of multi-group models for nonlocal electron transport in magnetized plasmas

In the extreme conditions of inertial confinement fusion experiments, heat flow plays a vital role, but local diffusive models frequently break down and overestimate the heat flow. The situation becomes more complicated again in the significant magnetic fields generated during laser–plasma interactions or in magnetized fusion schemes. Accurate non-local and magnetized heat flow computations can be carried out using Vlasov–Fokker–Planck (VFP) simulations, but these are computationally expensive. There is, therefore, significant interest in using faster multi-group models to accurately calculate the non-local heat flow in magnetized plasmas. We benchmark two such multi-group models for calculating the heat flow, M1 and hybrid-AWBS-BGK, against diffusive models and full VFP simulations, before applying the models to realistic example test cases, both magnetized and unmagnetized. We find that the multi-group models generally perform very well for moderate non-localities up to kλmfp∼0.01, but the computational cost increases dramatically. hybrid-AWBS-BGK performs more effectively than M1 at high non-localities, up to kλmfp∼1, due to its adaptive solver and robust P1 closure, but tends to fail in very strong magnetic fields. Both codes are much faster than VFP simulations but are still slow in steep temperature gradients.

Arran, C. (ORCID:0000000286448118)↗

Molten Chloride Thermophysical Properties, Chemical Optimization, and Purification

Next-generation concentrating solar power (CSP) technology requires high-temperature heat-transfer fluids and thermal energy storage that can operate in the temperature range of 500°–720°C. This high temperature demands a new chemistry for the heat-transfer fluids that must have high-temperature thermal and chemical stabilities, high energy density, and low corrosion rate on metallic materials used in the heat exchangers, piping, and thermal energy storage tanks. A ternary MgCl 2 -KCl-NaCl chloride-salt system has been proposed to achieve such goals, given its high-temperature thermal stability. The chloride-salt-based systems have been used by the metallurgy industry as the electrolyte to electrolytically extract metallic magnesium. They have also attracted attentions from the nuclear industry for developing the molten salt fast reactors that can operate at close to atmospheric pressure and at higher temperature than traditional light-water reactors. However, the corrosion properties of the ternary salt are not well known. The corrosion mechanism is believed to be correlated to the presence of MgOHCl impurity at the operation temperature. MgOHCl is fundamentally caused by the hygroscopic nature of the MgCl 2 component. Therefore, the first key objective of this project is to understand the nature of the corrosiveness of the ternary chloride-salt system and its prevention by designing new lab-scale purification processes. Because of its importance, a working group called the Chloride Salt Collective across multiple U.S. Department of Energy national laboratories is established to gain experimental agreement on the corrosion behaviors. In addition, water generation during salt dehydration could lead to highly corrosive HCl/water mixture via a hydrolysis process between water and anhydrous MgCl 2 or MgCl 2 hydrates. MgOHCl will eventually be converted to MgO particulates regardless of the chemical path chosen (i.e., by thermal decomposition, chemical purification with an active metal, or electrochemical purification utilizing the reduction power of electron flows). Large MgO particles with high hardness can wear out bearing and bushing and even clog the delicate channels in the primary heat exchanger. Because of this, a second objective is to understand the chemistry behind salt purification and transfer the scientific understanding to a set of engineering know-how for large-scale salt melter design. Because there is limited information on the thermophysical properties and the sensitivity of these properties around the targeted salt composition, a third objective is to measure thermophysical properties relevant to system and component design and support Topic 1 Liquid Pathway development. For example, composition shift due to salt reaction with water can be a potential issue because it can lead to changes of thermophysical properties, such as (1) melting point (or freeze point), which can jeopardize safe operation of the supercritical CO 2 power cycle proposed for next-generation CSP, and (2) heat capacity and density, which can decrease the overall power-generation capability of the plants. The value of the thermal conductivity of the selected salt composition is also a critical criterion for the solar receiver design.

14 SOLAR ENERGY↗

Sensitivity study of coupled chemical-CFD simulations for analyzing aluminum-clad spent nuclear fuel storage in sealed canisters

We report the United States Department of Energy (DOE) manages over 50 Metric Tons Heavy Metal (MTHM) of aluminum-clad spent nuclear fuel. One main source for DOE’s Aluminum-clad spent nuclear fuel (ASNF) inventory is the advanced test reactor (ATR) at the INL site, which makes this fuel of particular interest for storage scenarios. Road-ready and final disposition packaging configurations for the ATR fuel dictates storage within helium-backfilled, sealed DOE standard canisters. The conditions within these sealed canisters for extended (greater than50 year dry) storage is of interest. To further this goal, a three-dimensional (3D) multi-physics computational fluid dynamics (CFD) model is developed of the sealed DOE standard canisters. This 3D CFD model is one-way coupled with bulk gas radiolysis reactions considering sealed canisters with inert gas and possible trace amounts of air and water vapor. This study looks at the evolution of the thermal history of the canisters over a 50 year time period with a coupling to the chemical reactions occurring from radiolytic breakdown of residual water. A sensitivity study is then carried out over the parameters of the model including the fuel decay heat, residual water content, sealed pressure, canister external temperature, and canister emissivity. In pure helium, hydrogen generation rates are low, under 10 ppm, but hydrogen generation rates are affected greatly by the presence of even 1% residual air, increasing by 50-plus-fold, and nitric acid generation with residual air also occurs ranging from 500 to 4000 ppm after 50 years. The fuel decay heat and the residual water content show the most importance in the generation of hydrogen gas in pure air, and for nitric acid with a residual air condition. External temperature, canister emissivity and sealed pressure all show minor sensitivity effects to the generation of potentially harmful species.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Changes in electric field noise due to thermal transformation of a surface ion trap

Here, we aim to illuminate how the microscopic properties of a metal surface map to its electric field noise characteristics. In our system, prolonged heat treatments of a metal film can induce a rise in the magnitude of the electric field noise generated by the surface of that film. We refer to this heat-induced rise in noise magnitude as a thermal transformation. The underlying physics of this thermal transformation process is explored through a series of heating, milling, and electron treatments performed on a single surface ion trap. Between these treatments, 40 Ca + ions trapped 70 μm above the surface of the metal are used as detectors to monitor the electric field noise at frequencies close to 1 MHz. An Auger spectrometer is used to track changes in the composition of the contaminated metal surface. With these tools we investigate contaminant deposition, chemical reactions, and atomic restructuring as possible drivers of thermal transformations.

36 MATERIALS SCIENCE↗

Impact Analysis of Transitioning to Heat Pump Rooftop Units for the U.S. Commercial Building Stock: Preprint

20% of the U.S. commercial building sector's energy usage is from on-site combustion of fossil fuels for heating. Decarbonization will require electrification of these systems to meet climate goals, often by transitioning to heat pumps. Rooftop units (RTU) are the most prominent commercial building HVAC system type and should therefore be prioritized for decarbonization solutions. However, there is limited understanding of the impact on emissions that considers regional electricity generation methods, as well as the impact of other heat pump intricacies such as the effects of temperature on capacity/efficiency, defrost operation, realistic sizing methodologies, and supplementary heating. This study explores the effects of transitioning all conventional RTUs to high-performance heat pump RTUs for the U.S. commercial building stock. The analysis is performed using ComStock, DOE's calibrated model of the U.S. commercial building stock developed by NREL. Results show 9% and 17% reductions in stock aggregate energy consumption and GHG emissions, respectively. Furthermore, average heat pump operational details are presented by state. This analysis will help inform the transition to heat pump RTUs for the U.S. commercial building stock.

commercial building electrification↗

Pangenomes suggest ecological-evolutionary responses to experimental soil warming

ABSTRACT Below-ground carbon transformations that contribute to healthy soils represent a natural climate change mitigation, but newly acquired traits adaptive to climate stress may alter microbial feedback mechanisms. To better define microbial evolutionary responses to long-term climate warming, we study microorganisms from an ongoing in situ soil warming experiment where, for over three decades, temperate forest soils are continuously heated at 5°C above ambient. We hypothesize that across generations of chronic warming, genomic signatures within diverse bacterial lineages reflect adaptations related to growth and carbon utilization. From our bacterial culture collection isolated from experimental heated and control plots, we sequenced genomes representing dominant taxa sensitive to warming, including lineages of Actinobacteria, Alphaproteobacteria, and Betaproteobacteria. We investigated genomic attributes and functional gene content to identify signatures of adaptation. Comparative pangenomics revealed accessory gene clusters related to central metabolism, competition, and carbon substrate degradation, with few functional annotations explicitly associated with long-term warming. Trends in functional gene patterns suggest genomes from heated plots were relatively enriched in central carbohydrate and nitrogen metabolism pathways, while genomes from control plots were relatively enriched in amino acid and fatty acid metabolism pathways. We observed that genomes from heated plots had less codon bias, suggesting potential adaptive traits related to growth or growth efficiency. Codon usage bias varied for organisms with similar 16S rrn operon copy number, suggesting that these organisms experience different selective pressures on growth efficiency. Our work suggests the emergence of lineage-specific trends as well as common ecological-evolutionary microbial responses to climate change. IMPORTANCE Anthropogenic climate change threatens soil ecosystem health in part by altering below-ground carbon cycling carried out by microbes. Microbial evolutionary responses are often overshadowed by community-level ecological responses, but adaptive responses represent potential changes in traits and functional potential that may alter ecosystem function. We predict that microbes are adapting to climate change stressors like soil warming. To test this, we analyzed the genomes of bacteria from a soil warming experiment where soil plots have been experimentally heated 5°C above ambient for over 30 years. While genomic attributes were unchanged by long-term warming, we observed trends in functional gene content related to carbon and nitrogen usage and genomic indicators of growth efficiency. These responses may represent new parameters in how soil ecosystems feedback to the climate system.

Choudoir, Mallory J. (ORCID:0000000291175150)↗

Modeling a Sodium Heat Pipe Experiment at SPHERE Using Sockeye

The Single Primary Heat Extraction and Rejection Emulator (SPHERE) facility at Idaho National Laboratory was recently utilized to generate data for the startup and steady operation of a high-performance, sodium heat pipe over the course of 1,000 hours to test the detrimental, long-term effects of heat pipe operation. The setup consisted of a single, sodium heat pipe enclosed in a stainless-steel vacuum chamber, heated radiatively via a cylindrical ceramic-fiber heater configuration and cooled via a water-cooled calorimeter. Measurements included temperatures at several axial locations along the outer surface of the heat pipe, the power provided to the heaters, and the heat removal rate of the calorimeter. In this work, we use this data to validate heat pipe models in Sockeye, a heat pipe application based on the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework. Sockeye provides various heat pipe models at an engineering scale appropriate for the multiphysics simulation of microreactors, which may feature several hundred heat pipes. This work details models of this experiment at SPHERE using various heat pipe models with Sockeye, including heat-conduction-based and compressible flow models of the heat pipe interior.

97 - MATHEMATICS AND COMPUTING↗

Integration of Pumped Heat Energy Storage with Fossil-Fired Power Plant (Final Report)

The project team of Southwest Research Institute ® (SwRI ® ), Malta Inc. (Malta), and Luminant Generation Company LLC (Luminant) completed a feasibility study for the integration of a 100-MW, 10-hour (1000-MWh) Malta Pumped Heat Energy Storage (MPHES) system with multiple full-sized fossil-fired electricity generation units (EGU) in Luminant portfolio. MPHES is a long-duration, molten-salt-energy storage technology that uses turbomachinery and heat exchangers to transfer energy to a thermal storage media when charging, and removes the heat in a similar fashion when discharging. With high round trip efficiency (60-65%) and long lifespan (30+ years), MPHES provides economic benefits to the fossil-asset owners that can be scaled to integrate with assets across their portfolio. This technology uses hardware components, workforce personnel, and skillsets similar to those used by fossil EGUs, allowing for synergy when co-locating the two technologies. Luminant has approximately 39,000 megawatts of generation across 12 states, operating in six of the seven competitive markets in the U.S. and powered by a diverse portfolio of natural gas, nuclear, coal, and solar facilities. The DeCordova plant in Granbury, Texas, a simple cycle natural gas peaker power plant, was used as the fossil-fired asset in this project. The local market in Granbury, Texas has many influences, including several nearby power plants, a Luminant-owned nuclear plant (Comanche Peak), and substantial wind energy, which causes both negative pricing at night and high market volatility. Reducing false starts of the DeCordova plant and better responding to market volatility would be an economic advantage. Luminant is currently integrating battery storage plant on site to begin addressing these challenges. Integrating long-duration storage, like MPHES, would expand this capability beyond one hour of storage and have the potential to greatly reduce the total number of gas turbine starts. The MPHES charging requirement could help offset the overnight operating costs of Comanche Peak, which cannot load follow, and the nearby Luminant-owned Wise County combined cycle plant that cycles too often. Following the assessment of Luminant’s ERCOT-based portfolio for integration compatibility with Malta’s PHES system and the project tasks of conceptual study, technoeconomic analysis, technology gap assessment, and commercialization plan, the project team effort has resulted in several key outcomes: (1) Identification of market trends in a high-wind penetration market outside a major metropolitan area; (2) Creation of a dispatching model for the MPHES system and the pairing of Li-ion battery with a gas turbine in a real time market; (3) Revenue and cost estimations for operating MPHES alongside a gas peaker plant with real dispatching considerations and comparison with variations in the Malta implementation, including doubling the storage capacity and using two discharge drivetrains; (4) Potential carbon emission reductions possible by replacing gas turbine operation with Malta PHES operation; and (5) Summary of literature-based future market predictions for Texas.

20 FOSSIL-FUELED POWER PLANTS↗

Melting rate correlation with batch properties and melter operating conditions during conversion of nuclear waste melter feeds to glasses

The rate of conversion of nuclear waste melter feed to glass is affected by the selection of melter feed materials and by melter design and operation. The melting rate correlation (MRC) is an equation that relates the glass production rate with two types of variables: (1) feed and melt properties: conversion heat, cold-cap bottom temperature, and glass melt viscosity; and (2) melter design and operation parameters: melter geometry, melter operating temperature, and gas bubbling rate. The MRC shows good agreement for an extended melting-rate data set of high-level waste (HLW) melter feeds and a data set generated for low-activity waste (LAW) melter feeds. Laboratory observation of heated melter feed samples is often used to assess the cold-cap bottom temperature of HLW melter feeds (moderately foaming feeds), but this technique appears inadequate for LAW melter feeds (vigorously foaming feeds). For LAW feeds, an adequate assessment of the cold-cap bottom temperature was achieved using evolved gas analysis, which allows identification of the collapse of primary foam for oxidized feeds. This assessment shows that the cold-cap bottom temperature for vigorously foaming LAW feeds is higher than that for moderately foaming HLW feeds. When the results of MRC are compared, LAW feeds are generally less sensitive to the bubbling rate and melt viscosity, and more sensitive to the cold-cap bottom temperature than HLW feeds. The MRC qualifies as a promising tool to support the selection of melter feed materials and melter operating conditions, which is determined from expensive independent scaled melter experiments, and sophisticated mathematical models.

Lee, Seung Min↗

Role of On-Site Generation in Carbon Emissions and Utility Bill Savings under Different Electric Grid Scenarios

Energy-efficient and sustainable technologies are necessary to lower energy and carbon footprints. Many technologies are being pursued to meet the increasing energy demand in buildings. An attractive option is efficient utilization of available energy resources, including renewables, to support current and future building energy needs while targeting grid resiliency, energy, and environmental security at an affordable cost via on-site cogeneration-based approaches. This must include energy-efficient technologies with lower greenhouse gas emissions and optimized cost, performance, and reliability. This paper presents the economic and environmental benefits associated with power technologies such as thermionics and solid oxide fuel cells. Hybrid configurations consisting of heat pumps, power systems, and renewable photovoltaics in cogeneration and trigeneration modes of operation are presented. The role of such technologies in lowering CO2 emissions while improving energy resiliency and serving the needs of underprivileged communities is discussed. The key barriers of affordability and potential solutions for large-scale implementation of these promising technologies are reviewed. Case studies demonstrating the influence of power rating, electrical efficiency, design configuration, carbon dioxide intensity of the grid, and fuel on annual greenhouse gas emissions are presented for residential and commercial buildings.

24 POWER TRANSMISSION AND DISTRIBUTION↗