Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Guidelines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Report on initial development of a database of nuclear graphite characteristics based on microstructural characterization

This report outlines the current and future efforts to produce a comprehensive library of microstructures of nuclear graphite and carbon-based materials that are candidate materials for nuclear applications in the United States. This library must contain extensive characterizations of unirradiated graphite materials, a guide to some of the techniques used to characterize graphite, a compendium of characterization data of neutron-irradiated or oxidized material, and a compendium of microstructural information of carbon-based materials. These characterization efforts are being conducted at various length scales to understand these complex materials’ local structure and property relationships. Achieving this goal requires further developing or adapting advanced characterization techniques that capture graphite’s most relevant characteristics. Some of the general objectives of this project are to aid with the material selection, licensing, management, and core assessments of a graphite core by documenting the unirradiated microstructure of relevant grades or by characterizing the evolution of the microstructure under the reactor environment. Moreover, this project aims to provide additional information, guidelines for characterizing graphite, and a protocol to assess a nuclear graphite grade. This report also summarizes some of the initial results and some of the techniques commonly used to characterize nuclear graphite.

36 MATERIALS SCIENCE↗

Considerations regarding the Use of Computer Vision Machine Learning in Safety-Related or Risk-Significant Applications in Nuclear Power Plants

With the advancements made to date in the field of artificial intelligence (AI), significant potential exists to utilize AI capabilities for nuclear power plant (NPP) applications. AI can replicate human decision making and it is usually faster and more accurate than humans. For implementations that impact critical NPP applications (e.g., safety-related or non-safety systems that potentially affect overall plant risk), a deeper safety analysis of the AI methods is necessary. AI applied to NPP operations could resemble the use of digital I&C (DI&C) because such applications involve digital computer hardware and custom-designed software that input plant data, execute complex software algorithms, and output the results to a system or licensed human operator to potentially provoke an action. For AI methods to be compliant with current safety requirements for DI&C, AI compatibility must be evaluated, and AI-related gaps may exist that prevent the prompt deployment of AI in NPPs. This effort aims to evaluate how example AI technologies align with the DI&C safety framework, and discusses how they could be analyzed, modeled, tested, and validated in a manner similar to typical DI&C technologies. Because AI is a broad field that encompasses areas such as machine learning (ML), natural language processing, and computer vision, this research focused on a subset of methods categorized as the computer vision ML (CVML) methods. This report explores two CVML use cases, gauge reading and fire watch, considered relevant to the DI&C standards, as they could play a safety-critical role. For the gauge reading use case, a CVML-enabled technology that can read gauges at oblique angles is utilized. For the fire watch use case, a CVML-enabled technology is utilized that migrates fire watch from a manual (human) approach to automated fire detection. These use cases are mainly intended to give context to the CVML system discussion. This effort assumes the worst-case scenario, with the CVML system being used to replace a safety-related or risk-significant system, thus requiring evaluation. Evaluating CVML against most of the relevant safety requirements for DI&C yielded several CVML-specific considerations due to the uniqueness of its characteristics in comparison with typical DI&C systems. For example, CVML models often employ commonly used (open-source) datasets, and it is not always possible to determine the level of overlap among open-source datasets. Therefore, the independence of the developed CVML models when demonstrating diversity is questionable, therefore creating vulnerability to common cause failure (CCF). The design verification process is also impacted since the data overlap could result in overestimation of the software validation and verification (V&V) performance results. Section 2 of this report evaluates a list of the identified CVML-specific characteristics and discusses the resulting considerations and potential solutions in the context of each referenced requirement. A summation is provided in Section 3. This report is not to be used as a guideline. It was developed to identify and consider issues in the implementation of ML technologies used to augment activities that may have a bearing on plant operation. The report draws parallels to the use of DI&C technologies, for which many standards are available to guide their use in nuclear plant operation. It considers the technologies and some of the potential implications of their use in safety-related applications but is not intended to address regulatory or licensing related issues.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report (DOE 2023) provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

42 ENGINEERING↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

TSQP Writing Qualification Standards [Slides]

The purpose of this course is to help you develop the skills necessary to create qualification standards, using the approved LANL template following guidelines and requirements established in appropriate drivers.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

VERAIn Programmer's Manual

This document provides information needed by developers who will be working in the VERAIn source code. It provides a high-level overview of input design, as well as guidelines for adding new inputs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Quality Control Methods for Measurement of UCO Kernel Composition and SiC Microstructure

Quality control (QC) is critically important to tristructural-isotropic (TRISO) particle fuels owing to the complexity of and reliance on the fuel form to contain fission products during irradiation. Characterization methods for particle fuel QC have decades of history and have continued to develop as new insights into fuel performance inform revised fuel specifications and as advances in underlying technologies expand the possibilities of what may be characterized. Two relatively new methods for characterization of TRISO fuels have been published in open literature: optical microscopy image analysis for mixed uranium carbide/uranium oxide (UCO) kernel composition analysis and automated grain boundary detection in backscattered electron (BSE) images of the silicon carbide (SiC) layer in TRISO particles for grain size characterization. Suggestions and guidelines for the application of these methods to TRISO fuel qualification are provided in this report.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Conditions Assessment and Preservation Work Plan for Portable Guard Shacks (TA-8-172 and TA-18-111)

The purpose of this report is to document the current state of deterioration and propose repairs for TA-8-172 and TA18-111, two portable guard shacks from the Los Alamos National Laboratory (LANL) which have been designated as historic resources. This preservation treatment plan has been prepared by the Historic Preservation Training Center (HPTC), a historic preservation program within the National Park Service, to ensure that the treatments comply with guidelines established in The Secretary of the Interior’s Standards for the Treatment of Historic Properties.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Performance Audit Report: Automated Meteorological Monitoring Stations, Lawrence Livermore National Laboratory

The Waste and Air Quality Offices Group at the Lawrence Livermore National Laboratory operates two main meteorological monitoring sites near Livermore, California. The primary met tower (Site 200) is located in the northwest corner of the lab and consists of a fifty-two (52) meter tower with vertical wind speed sensors, horizontal wind speed and direction sensors and air temperature sensors at fifty-two (52) meters, twenty-three (23) meters and ten (10) meters. In addition, there is a temperature and humidity probe at ten (10) meters. At two (2) meters there are upward and downward facing solar and infrared radiation sensors, an air temperature sensor, barometric pressure sensor and a temperature and relative humidity probe. At ground level there is a tipping bucket rain gauge located to the southwest of the tower. The datalogger, communication peripherals and the barometric pressure sensor are housed in a small building near the tower. The Site 300 met site is located approximately 10 miles east of Livermore within the boundary of the LLNL blast test site. This site also consists of a 52-meter tower which is configured the same as the 52-meter tower at Site 200. There is also a building at this site that houses the datalogger, communication peripherals and the barometric pressure sensor. At both Site 200 and Site 300, data are collected by Ethernet with telephone modem collection as a backup. The data collection interval for both sites is fifteen (15) minutes via workstations running Loggernet software located at the main lab facility. The audits of the Lawrence Livermore National Laboratory’s two automated meteorological stations located near Livermore, California were performed on October 24 & 25, 2023. These audits were performed under the guidelines of the Quality Assurance Handbook for Air Pollution Measurement Systems, Volume IV, Version 2 and the On-Site Meteorological Program Guidance for Regulatory Modeling Applications, U.S. EPA.

54 ENVIRONMENTAL SCIENCES↗

Universal Input-Output Model of GFM Functions and Data-Driven Verification Methods

An overarching goal of the UNiversal Interoperability for grid-Forming Inverters (UNIFI) Consortium is to develop vendor agnostic specifications and guidelines that ensure interoperability of gridforming (GFM) inverter-based resources (IBRs) without requiring vendors or system operators to reveal proprietary information. These UNIFI principles and specifications are envisioned to apply to a wide range of technologies and systems. The initial work on the UNIFI principles and specifications has focused on performance requirements and high-level aspirational principles outlined in [1]. Going forward, a key question is how to translate such high-level requirements and principles into rigorous specifications that can be enforced and validated for a wide range of IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Assessment of Machine Learning Applied to Ultrasonic Nondestructive Evaluation

In the United States, the nuclear industry performs inservice inspection (ISI) through nondestructive examination (NDE) methods in accordance with guidelines specified in the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (BPVC), Section XI, Rules for Inservice Inspection of Nuclear Power Plant Components. Ultrasonic nondestructive testing and evaluation (NDT&E) is one of the more commonly used techniques for inspecting Class 1 structural components in nuclear power systems. As the number of qualified NDE inspectors declines, the nuclear industry is looking to take advantage of advances in automation to enhance inspection capabilities. Advances in computational power, cloud-based computing, and machine learning algorithms make automated data analysis possible. Machine learning (ML) has shown huge potential in automated data analyses for ultrasonic NDE in the context of weld inspections.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

COBRA-SFS Version 6.2.1 User Guide: A Thermal Hydraulic Analysis Code for Spent Fuel Storage and Transportation Casks

This document is an updated and reduced version of the complete documentation of the COBRA-SFS thermal analysis code (COolant Boiling in Rod Arrays – Spent Fuel Storage) (Michener et al. 1995). This manual provides the analyst with input instructions and fundamental guidelines for contrasting models using COBRA-SFS. COBRA-SFS is designed to analyze the dry storage and transportation casks that house spent or used nuclear fuel. The primary focus and application is on square light water reactor fuel assemblies, however the code also has the capability to model hexagonal assemblies and is will suited to any geometry that can be defined as an extruded 2-D map.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Complete Evaluation on Advanced Reactor Machine Learning Subversion Attacks (Final)

Navigating through the world of Artificial Intelligence (AI) in nuclear reactors and their Instrumentation and Control (I&C) systems demands a careful, deliberate journey. AI’s capability to manage massive datasets and streamline control systems has indeed carved out a significant role in various sectors, including nuclear energy. However, while AI, and particularly Large Language Models (LLMs), bring a lot to the table in terms of operational efficiency and anomaly detection, they also expose the sector to a new breed of cybersecurity threats, like Inference Attacks, Adversarial Attacks, and Trojan Attacks. This guide is designed to be a straightforward manual, diving deep into the intertwining worlds of AI and cybersecurity within nuclear reactors, and tailoring insights for three crucial audiences: I&C Vendors/Developers, Nuclear Regulators, and Nuclear Reactor Operators and Cyber Defense Teams. (1) Section 2, directed at I&C Vendors/Developers, will provide a clear and focused look at several cybersecurity attacks, offering practical recommendations and detailed scenarios related to AI cybersecurity. This section isn’t just about identifying problems but also about giving solid, usable solutions. (2) Section 3, meant for Nuclear Regulators, gets straight to the point about regulations, policy suggestions, and guidelines that are needed to lay down a robust, secure, and ethical foundation for the application of AI in nuclear operations. The focus is on making sure that everything adheres to international standards and laws while being practicable and clear-cut. (3) Section 4, aimed at Nuclear Reactor Operators and Cyber Defense Teams, offers an exhaustive exploration and technical reports, with clear recommendations and scenario analyses vital to protect operational environments and guarantee the secure application of AI in nuclear reactor operations. The goal is simple: as we step into an era where AI becomes a fundamental element of our technological and energy infrastructures, this guide is here to act as a clear, direct handbook, ensuring that AI is implemented within the nuclear sector in a manner that is secure, responsible, and practical. It’s about striking a balance – optimizing the undeniable benefits offered by AI while securing and shielding against potential cyber threats as we move through this new and complex landscape.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modeling and Policy Pathways to Decarbonize South Asia’s Industrial Sector

The industrial sector is responsible for one-third of global greenhouse gas emissions, and industrial decarbonization will be an essential component of limiting emissions and mitigating climate change (Rissman et al., 2020). This holds true for South Asian countries as they work toward their stated commitments to reducing emissions in the coming years. India has pledged to reduce the emissions intensity of its gross domestic product (GDP) by 33–35% by 2030 (Government of India, 2016) and announced at COP26 a target of reaching net-zero CO 2 emissions by 2070, a goal that will require rapid decarbonization of energy-intensive industries (WEF, 2021). Bangladesh’s Nationally Determined Contributions include a commitment to reducing greenhouse gas emissions by 6.73% to 15.12% by 2030 (Ministry of Environment, Forest and Climate Change, 2021). While these Nationally Determined Contributions do not explicitly target emissions reductions in industry, Bangladesh’s Energy Efficiency and Conservation (EE&C) Master Plan highlights industry as an important sector for EE&C (Sustainable and Renewable Energy Development Authority, 2015). Sri Lanka has pledged carbon neutrality by 2050, including a reduction in industrial greenhouse gas emissions (Ministry of Environment, 2021). Nepal’s commitment to net-zero greenhouse gas emissions by 2050 includes plans to establish guidelines and technology transitions facilitating industrial decarbonization (Government of Nepal, 2020).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Industrial Assessment Center

Established in 1990, San Diego State University’s (SDSU) Industrial Assessment Center (IAC) is proud of its years of service. During this period, it has served over 620 small and medium-sized manufacturing plants in Southern California. SDSU/IAC’s efforts to transfer state-of-the-art technologies to industry have increased revenues, cultivated creativity, improved energy efficiencies, and benefited the environment. The Center has contributed to the region's economic growth and stability by assisting small and medium size companies to better compete in the global market. It has helped mitigate climate change by reducing greenhouse gas emissions. IAC activities have fostered productive relationships between the University and local industry, assisted industrial sectors to improve their energy efficiency and enhance their manufacturing productivity, in turn impacting the material and working conditions of their employees. In addition to financial savings and environmental benefits, we have trained tens of students who became energy specialists in various companies. Thus, a substantial benefit of the IAC has been the ongoing training of engineering faculty and students. All IAC graduates were offered jobs before or within weeks of their graduation. The activities of the SDSU/IAC have expanded the institutional expertise of the College and improved the knowledge base of the faculties involved leading to several related publications, master’s theses, and senior student projects. Significant number of peer-reviewed publications of the IAC director at SDSU have greatly benefitted from the experience of the Center. As a result of this extensive exposure to manufacturing processes, the SDSU/IAC has grown to be an integral component of SDSU’s engineering research and training. We have successfully built upon these established achievements and academic excellence. IAC service to industry is particularly vital in Southern California, a region with one of the highest manufacturing concentrations in the country. SDSU/IAC has understood and implemented the overall objectives of DOE’s IAC program and guidelines except for the pandemic years when the country’s manufacturing sector was put in dire stress. In addition to student training and service to industry, IAC’s contribution to state and local governments as well as utility companies to assess energy policies and design rebate and incentive strategies cannot be undermined.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Driving the Shift to Energy-Efficient and Climate-Responsible Commercial Refrigeration Equipment in Chile

This report provides an overview of global and Chile-specific market trends, technological advancements, and policy developments related to commercial refrigeration equipment, with an emphasis on refrigerated display cabinets. Section 2 examines CRE market trends at the global and Chilean levels. Section 3 presents CRE energy consumption and the latest technological options for improving energy performance. It also discusses low global warming potential (GWP)1 refrigerant options for CRE. Section 4 provides a cost-effectiveness analysis. Section 5 reviews other regional energy efficiency standards and labeling programs and offers potential standard requirements for Chile. Section 6 concludes the report by summarizing key findings and conclusions. Finally, Appendix A provides detailed guidelines intended as a starting point to inform policies and programmes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ORNL Contributions to the ENDF/B-VIII.1 Library [Slides]

For uranium and plutonium isotopes, evaluation work is converging to a stable configuration with an overall satisfactory benchmark performance (more information on the validation tests after CSEWG). Strontium evaluation was included in the repository library and successfully tested by processing codes relative to an alternative quantification of the external function. Cerium covariance matrices were updated to address review comments on the magnitude of the uncertainty. For future uncertainty quantification, theoretical observables should be properly decoupled from current measured guidelines. Tests to correctly include LP (from resonance parameters) fitted to measured energy-averaged data are in progress. Current ENDF files contains experimental LP data.

07 ISOTOPE AND RADIATION SOURCES↗