Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Geothermal Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Elko County School District (ECSD) Geothermal Evaluation: Basin College Direct Use Geothermal Demonstration Project

The system has been in continuous operation since October 1986 and serves various customers with approximately 180°F geothermal heating water for use at each facility as shown in Exhibit B. The system which is maintained by the school district consists of two main water loops. The system was designed for a large temperature difference instead of the normal 20°ΔT heating system. Using the design 80°ΔT, we yield 4+ times more energy with the same water flow. Loop 1 is the main geothermal water loop which flows from the production well through two main system heat exchangers and, after heat is extracted, to the disposal area. Loop 2, the customer heating loop, is heated in the main heat exchangers and then runs through approximately 5500 feet of buried supply piping and approximately 5500 feet of buried return piping to each customer facility where a facility heat exchanger is provided for each customers use. All piping on the customers’ side of each facility heat exchanger is the responsibility of the individual customer. Although originally designed to work with an 80ºΔT, this has deteriorated over the years and cannot achieve this at the present time. The system has operated over the last 29 years with minimal maintenance but is now starting to show its age with various corrosion issues, control problems, and several leaks. Some parts of the system are also located in areas where proposed building expansions will require piping relocations.This is the final technical report for the Great Basin College Direct Use Geothermal Demonstrationn Project, outlining the technical aspects of the User Group System.

15 GEOTHERMAL ENERGY↗

INGENIOUS - Great Basin Regional Dataset Compilation

This is the regional dataset compilation for the INnovative Geothermal Exploration through Novel Investigations Of Undiscovered Systems (INGENIOUS) project. The primary goal of this project is to accelerate discoveries of new, commercially viable hidden geothermal systems while reducing the exploration and development risks for all geothermal resources. These datasets will be used in INGENIOUS as input features for predicting geothermal favorability throughout the Great Basin study area. Datasets consist of shapefiles, geotiffs, tabular spreadsheets, and metadata that describe: 2-meter temperature probe surveys, quaternary faults and volcanic features, geodetic shear and dilation models, heat flow, magnetotellurics (conductance), magnetics, gravity, paleogeothermal features (such as sinter and tufa deposits), seismicity, spring and well temperatures, spring and well aqueous geochemistry analyses, thermal conductivity, and fault slip and dilation tendency. For additional project information, see the INGENIOUS project site linked in the submission. Terms of use: These datasets are provided "as is", and the contributors assume no responsibility for any errors or omissions. The user assumes the entire risk associated with their use of these data and bears all responsibility in determining whether these data are fit for their intended use. These datasets may be redistributed with attribution (see citation information below). Please refer to the license information on this page for full licensing terms and conditions.

15 GEOTHERMAL ENERGY↗

Geothermally Coupled Well-Based Compressed Air Energy Storage

Previous work by McGrail et al. (2013, 2015) has evaluated the possibility of pairing compressed air energy storage with geothermal resources in lieu of a fossil-fired power generation component, and suggests that such applications may be cost competitive where geology is favorable to siting both the geothermal and CAES components of such a system. Those studies also note that the collocation of subsurface resources that meet both sets of requirements are difficult to find in areas that also offer infrastructure and near- to mid-term market demand for energy storage. This study examines a novel application for the compressed air storage portion of the project by evaluating the potential to store compressed air in disused wells by amending well casings to serve as subsurface pressure vessels. Because the wells themselves would function in lieu of a geologic storage reservoir for the CAES element of the project, siting could focus on locations with suitable geothermal resources, as long as there was also existing wellfield infrastructure that could be repurposed for air storage. Existing wellfields abound in the United States, and with current low energy prices, many recently productive fields are now shut in. Should energy prices remain stagnant, these idle fields will be prime candidates for decommissioning unless they can be transitioned to other uses, such as redevelopment for energy storage. In addition to the nation’s ubiquitous oil and gas fields, geothermal fields, because of their phased production lifetimes, also may offer many abandoned wellbores that could be used for other purposes, often near currently productive geothermal resources. These existing fields offer an opportunity to decrease exploration and development uncertainty by leveraging data developed during prior field characterization, drilling, and production. They may also offer lower-cost deployment options for hybrid geothermal systems via redevelopment of existing well-field infrastructure. This project assessed the technical and economic feasibility of implementing geothermally coupled well-based CAES for grid-scale energy storage. Based on an evaluation of design specifications for a range of casing grades common in U.S. oil and gas fields, a 5-MW CAES project could be supported by twenty to twenty-five 5,000-foot, 7-inch wells using lower-grade casing, and as few as eight such wells for higher-end casing grades. Using this information, along with data on geothermal resources, well density, and potential future markets for energy storage systems, The Geysers geothermal field was selected to parameterize a case study to evaluate the potential match between the proven geothermal resource present at The Geysers and the field’s existing well infrastructure. Based on calculated wellbore compressed air mass, the study shows that a single average geothermal production well could provide enough geothermal energy to support a 15.4-MW (gross) power generation facility using 34 to 35 geothermal wells repurposed for compressed air storage, resulting in a simplified levelized cost of electricity (sLCOE) estimated at 11.2 ¢/kWh (Table S.1). Accounting for the power loss to the geothermal power project associated with diverting geothermal resources for air heating results in a net 2-MW decrease in generation capacity, increasing the CAES project’s sLCOE by 1.8 ¢/kWh.

15 GEOTHERMAL ENERGY↗

Geothermally Coupled Well-Based Compressed Air Energy Storage

Previous work by McGrail et al. (2013, 2015) has evaluated the possibility of pairing compressed air energy storage with geothermal resources in lieu of a fossil-fired power generation component, and suggests that such applications may be cost competitive where geology is favorable to siting both the geothermal and CAES components of such a system. Those studies also note that the collocation of subsurface resources that meet both sets of requirements are difficult to find in areas that also offer infrastructure and near- to mid-term market demand for energy storage. This study examines a novel application for the compressed air storage portion of the project by evaluating the potential to store compressed air in disused wells by amending well casings to serve as subsurface pressure vessels. Because the wells themselves would function in lieu of a geologic storage reservoir for the CAES element of the project, siting could focus on locations with suitable geothermal resources, as long as there was also existing wellfield infrastructure that could be repurposed for air storage. Existing wellfields abound in the United States, and with current low energy prices, many recently productive fields are now shut in. Should energy prices remain stagnant, these idle fields will be prime candidates for decommissioning unless they can be transitioned to other uses, such as redevelopment for energy storage. In addition to the nation’s ubiquitous oil and gas fields, geothermal fields, because of their phased production lifetimes, also may offer many abandoned wellbores that could be used for other purposes, often near currently productive geothermal resources. These existing fields offer an opportunity to decrease exploration and development uncertainty by leveraging data developed during prior field characterization, drilling, and production. They may also offer lower-cost deployment options for hybrid geothermal systems via redevelopment of existing well-field infrastructure. This project assessed the technical and economic feasibility of implementing geothermally coupled well-based CAES for grid-scale energy storage. Based on an evaluation of design specifications for a range of casing grades common in U.S. oil and gas fields, a 5-MW CAES project could be supported by twenty to twenty-five 5,000-foot, 7-inch wells using lower-grade casing, and as few as eight such wells for higher-end casing grades. Using this information, along with data on geothermal resources, well density, and potential future markets for energy storage systems, The Geysers geothermal field was selected to parameterize a case study to evaluate the potential match between the proven geothermal resource present at The Geysers and the field’s existing well infrastructure. Based on calculated wellbore compressed air mass, the study shows that a single average geothermal production well could provide enough geothermal energy to support a 15.4-MW (gross) power generation facility using 34 to 35 geothermal wells repurposed for compressed air storage, resulting in a simplified levelized cost of electricity (sLCOE) estimated at 11.2 ¢/kWh (Table S.1). Accounting for the power loss to the geothermal power project associated with diverting geothermal resources for air heating results in a net 2-MW decrease in generation capacity, increasing the CAES project’s sLCOE by 1.8 ¢/kWh.

25 ENERGY STORAGE↗

Assessing the Economic Value of Underground Thermal Storage for Hybrid Geothermal Power

Solutions are needed to address resource adequacy in the electric power system for highly decarbonized systems. The storage duration, the length of time a storage device can provide continuous output at its rated capacity, must be sufficient to receive full credit toward resource adequacy. Longer peaks and high fractions of variable renewable generation have increased the required duration to potentially seasonal durations. Underground Thermal Energy Storage (UTES) can be adapted to a hybrid storage power plant or heating and cooling applications to satisfy the need for long-duration storage. In this study, we use the Renewable Energy Deployment System (ReEDS) capacity expansion model to evaluate the increase in value for an enhanced geothermal system (EGS) resources by adding UTES. In modeled scenarios, using geothermal without storage as a baseline we compare the increase in economic value for plants with a range of storage characteristics. The added value of a hybrid storage plant changes depending on assumptions including the length of storage duration, efficiency, and ability to charge storage from the grid during periods of low energy prices. Relating proposed characteristics for geothermal UTES hybrids to the modeled economic value provides insight into economically viable costs for developing UTES as well as what combination of technology characteristics and future energy and policy assumptions drive significant value increases.

capacity expansion model↗

Development and Preliminary Analysis of a U.S. Geothermal Heat Pump Installation Database

This paper seeks to addresses the significant gap in the literature regarding the installation and adoption of geothermal heat pump (GHP) systems in the United States. While the "2021 U.S. Geothermal Power Production and District Heating Market Report" published by the National Renewable Energy Laboratory (NREL) focused on direct-use geothermal district heating systems, it did not include an analysis of GHP installations (Robins et al. 2021). To bridge this gap, NREL has compiled a novel database currently containing 70,470 records of GHP installations, primarily sourced from state well permits and small-scale studies. Our methodology emphasizes the collection, cleaning, and standardization of data, addressing challenges such as inconsistent reporting formats and privacy concerns. Despite limitations in data on capacity, costs, and performance, our preliminary geospatial analysis reveals insights into the distribution of GHP systems across urban and rural areas and climate zones. The paper highlights the importance of publicly accessible data for advancing GHP technology adoption with a discussion of existing data sources and their limitations, advocating for improved collaboration between NREL and industry stakeholders.

data collection↗

Low-Temperature Projects of the Department of Energy's Geothermal Technologies Program: Evaluation and Lessons Learned

This paper discusses opportunities and challenges related to the technical and economic feasibility of developing power generation from geothermal resources at temperatures of 150 degrees C and lower. Insights from projects funded by the U.S. Department of Energy (DOE), Geothermal Technologies Office inform these discussions and provide the basis for some lessons learned to help guide decisions by DOE and the industry in further developing this resource. The technical basis for low-temperature geothermal energy is well established and the systems can be economic today in certain situations. However, these applications are far from a 'plug and play' product; successful development today requires a good knowledge of geothermal system design and operation.

15 GEOTHERMAL ENERGY↗

Low-Temperature Projects of the Department of Energy's Geothermal Technologies Program: Evaluation and Lessons Learned: Preprint

This paper discusses opportunities and challenges related to the technical and economic feasibility of developing power generation from geothermal resources at temperatures of 150 degrees C and lower. Insights from projects funded by the U.S. Department of Energy (DOE), Geothermal Technologies Office inform these discussions and provide the basis for some lessons learned to help guide decisions by DOE and the industry in further developing this resource. The technical basis for low-temperature geothermal energy is well established and the systems can be economic today in certain situations. However, these applications are far from a 'plug and play' product; successful development today requires a good knowledge of geothermal system design and operation.

15 GEOTHERMAL ENERGY↗

DOE-GTO Low Temperture Projects Evaluation and Lessons Learned

This paper discusses opportunities and challenges related to the technical and economic feasibility of developing power generation from geothermal resources at temperatures of 150 degrees C and lower. Insights from projects funded by the U.S. Department of Energy (DOE), Geothermal Technologies Office inform these discussions and provide the basis for some lessons learned to help guide decisions by DOE and the industry in further developing this resource. The technical basis for low-temperature geothermal energy is well established and the systems can be economic today in certain situations. However, these applications are far from a 'plug and play' product; successful development today requires a good knowledge of geothermal system design and operation.

15 GEOTHERMAL ENERGY↗

EXERGETIC: De-Risking Next-Generation Resilient Geothermal Hybrids via At-Scale Evaluation Using Virtual Emulation Digital Twin Environment for Efficient Operation

The DOE-GTO-funded project, award number 5.1.2.12, entitled "EXERGETIC - De-risking Next Generation Resilient Geothermal Hybrids via at-Scale Evaluation Using a Virtual Emulation Digital Twin Environment for Efficient Operation," advances the solution to these challenges by developing and validating a geothermal co-emulation environment implemented at the National Laboratory of the Rockies (NLR)'s Advanced Research on Integrated Energy Systems (ARIES) platform. This framework enables the de-risking of next-generation geothermal and geothermal hybrid systems through high-fidelity modeling, real-time digital emulation, advanced control strategies, and techno-economic assessment. The project focused on geothermal hybrid configurations that integrate geothermal power plants with concentrated solar power and underground thermal energy storage, enabling enhanced efficiency, flexibility, and grid support capabilities. The main goal of this project was the development of a geothermal digital co-emulation environment to demonstrate the technical and economic value of geothermal hybrid systems and their contribution to grid stability and flexibility. The EXERGETIC framework combined physics-based models, controls, and real assets at ARIES, including digital real-time simulators (DRTS), a 20-MW-scale controllable grid interface (CGI), and a 2-MW conventional generator. Detailed transient models were developed for the key subsystems of a hybrid geothermal plant, including parabolic trough solar collectors, reservoir thermal energy storage (RTES), and a binary Organic Rankine Cycle (ORC) power plant. The ORC model explicitly captured thermal inertia and off-design operation and integrated control strategies to dynamically respond to electric load profiles. The models were validated against published experimental and numerical studies, demonstrating strong agreement and confirming the accuracy and robustness of the modeling approach. The resulting digital twin represents geothermal-solar-storage systems at multiple scales (1 MW to 100 MW) and enables realistic emulation of grid-connected operation. The control architecture allows the geothermal resource to provide stable baseload generation, while solar and stored thermal energy supply flexible, dispatchable support during periods of high demand or variable grid conditions. A key contribution of the EXERGETIC project is the demonstration that geothermal hybrid systems can be designed to be active grid assets rather than passive baseload generators. Using the ARIES platform, the digital twin was evaluated under multiple grid scenarios, including load following, voltage support at the distribution level, and frequency response at the transmission level. Results show that hybrid geothermal systems can respond effectively to dynamic grid conditions, providing inertia-like behavior, primary frequency support, and voltage regulation through coordinated control. In addition to the performance and grid services capability analysis of geothermal and hybrid geothermal systems, the EXERGETIC project also focused on scalability and techno-economic analysis of geothermal hybrid plants. In particular, for the scalability analysis, machine-learning (ML)-based surrogate models were trained using data generated from the geothermal digital twin under different grid-connected scenarios and plant capacities. These ML models demonstrated strong interpolation and extrapolation capabilities across plant sizes, accurately reproducing both steady-state and transient responses with very low errors. Regarding the techno-economic analysis, plant performance results were integrated with cost models for hybrid geothermal systems, and the levelized cost of electricity (LCOE) was used as the main economic metric to evaluate system performance across a range of system capacities, solar shares, solar multiples, and storage durations. Results indicate that economies of scale significantly reduce geothermal LCOE as plant capacity increases, with large-scale systems (25-100 MW) achieving substantially lower costs than small plants. Hybridization with solar thermal energy and storage further improves economic performance by increasing capacity utilization and enabling flexible dispatch. In addition, thermal storage plays a critical role in reducing LCOE by maximizing geothermal, solar, and stored energy resources. In summary, the results from this project demonstrate that geothermal hybrid systems represent a promising alternative for increasing the energy conversion efficiency of geothermal technologies, contributing to the preservation of geothermal resources, and supporting the transition of geothermal plants from traditional baseload resources into flexible, resilient, and cost-competitive energy conversion technologies.

15 GEOTHERMAL ENERGY↗

Advanced Testing Method for Ground Thermal Conductivity

A new method is developed that can quickly and more accurately determine the effective ground thermal conductivity (GTC) based on thermal response test (TRT) results. Ground thermal conductivity is an important parameter for sizing ground heat exchangers (GHEXs) used by geothermal heat pump systems. The conventional GTC test method usually requires a TRT for 48 hours with a very stable electric power supply throughout the entire test. In contrast, the new method reduces the required test time by 40%–60% or more, and it can determine GTC even with an unstable or intermittent power supply. Consequently, it can significantly reduce the cost of GTC testing and increase its use, which will enable optimal design of geothermal heat pump systems. Further, this new method provides more information about the thermal properties of the GHEX and the ground than previous techniques. It can verify the installation quality of GHEXs and has the potential, if developed, to characterize the heterogeneous thermal properties of the ground formation surrounding the GHEXs.

47 OTHER INSTRUMENTATION↗

Characterization of Li in the Salton Sea Geothermal Field

Abstract The behavior of lithium during geothermal brine and host-rock interactions in the Salton Sea geothermal field is underconstrained. The lithium brine reservoir inventory is between 4 and 18 million metric tons of lithium carbonate equivalent, with an even larger amount present within the reservoir rock mineral phases. Here, we present bulk-rock and brine Li concentration and δ7Li, and in situ Li concentrations of minerals from the California State 2-14 scientific drill core and commercial wells in the Salton Sea geothermal field to identify the mineral hosts of Li and constrain Li behavior during brine-rock interactions. Lithium contents are highest in chlorite (270–580 ppm, ~2,358 m), which encases pyrite, indicating that Li is fixed from the brine into the host rocks during hydrothermal alteration. Lithium abundances in chlorite decrease with depth (70–100 ppm, ~2,882 m), as does whole-rock Li content, whereas whole-rock δ7Li increases (δ7Li = 2.0–4.3‰, ~2,485-m depth; δ7Li = 4.3–7.9‰ from ~2,819 to ~2,882 m). This change in behavior of Li at ~2,500 m suggests temperature dependent partitioning of Li in chlorite; Li becomes more incompatible in chlorite at depths >~2,500 m, corresponding to ~325°C in the reservoir. The brines have δ7Li = 3.7 to 4.7‰ and calculated isotopic fractionation factors between the brine and the host rock agree with a change in Li behavior at ~325°C. Simple closed-system batch modeling does not describe the geothermal system, suggesting open-system behavior of Li within the Salton Sea geothermal field.

Humphreys, J↗

Systems, methods and tools for subterranean electrochemical characterization and enthalpy measurement in geothermal reservoirs

The present disclosure is directed to systems, methods and tools that measure ionic concentrations and downhole enthalpy of a flowing geothermal fluid in real-time at high-temperature and pressure. The systems, methods and tools include measuring the concentration of selected naturally occurring ions found in the liquid phase of the geothermal fluid throughout the wellbore using novel electrochemical sensor technologies. The change in liquid-phase ion concentration will be used to calculate the proportion of liquid to steam and allow for accurate enthalpy measurements. The techniques and technologies described here can be applied to any application of electrochemical sensing in extreme environments.

Cieslewski, Grzegorz↗

Sedimentary Geothermal Resources in Nevada, Utah, Colorado, and Texas

The objectives of this project were to (1) perform a literature review of sedimentary geothermal resources, (2) identify data sources and develop data-collection methodologies that characterize selected resources, (3) screen sedimentary basins and formations for sedimentary geothermal potential, and (4) evaluate the technical feasibility of one or more selected locations. Numerous publications have characterized geothermal resources within sedimentary basins. A literature search reviewed publications describing resources located in Colorado, Louisiana, Nevada, Texas, Utah, and Wyoming. The most attractive resources have high temperature gradients, low drilling costs, and reservoir permeabilities greater than 10 millidarcies (mD). Prospects in Colorado, Nevada, Texas, and Utah exhibit attractive characteristics and were chosen for further analysis. Sedimentary resources in Nevada and Utah are most attractive, followed by tested resources in Texas and untested resources in Colorado. The identified resources in Wyoming and Louisiana had lower geothermal gradients and were not evaluated. Reservoir modeling and techno-economic analysis were performed at Marys River Basin–North in Nevada. Geothermal energy production at this location is expected to have a levelized cost of energy (LCOE) ranging between 10 and 20 cents/kWh. Additional work may result in lower LCOE estimates at this location and at other attractive prospects in these three regions. The Great Basin carbonate and alluvial aquifer system of eastern Nevada and western Utah includes a lower carbonate aquifer unit, which has the potential for hosting both conduction- and convection-dominated geothermal systems. Mapping has identified lateral thickness variability expressed as a roughly 120–150-km-wide central corridor, which hosts the thickest and most continuous formations and extends from near Las Vegas north to the Idaho border. Purchase and analysis of privately held legacy seismic data could potentially compensate for the lack of sufficient data documenting measured depth to the lower carbonate aquifer unit. Multiple orogenies, extension episodes, and intrusive events have deformed and displaced the target formations of the lower carbonate aquifer unit. This structural complexity and potential for dipping reservoirs emphasizes the need for detailed geological, geophysical, and reservoir modeling. Heat flow within three Colorado sedimentary basins reviewed as part of this study was calculated in targeted studies by the Colorado Geologic Survey and Colorado School of Mines. These calculations are based on bottom-hole temperature data sets with significant limitations and some variability but produce values consistently higher than the global continental average of 65 mW/m2 for all three basins. Heat flow in the Raton Basin is the highest; however, permeability measurements from specific sedimentary formations with high heat flow have not been obtained. Promising formations for sedimentary geothermal systems were found in all three regions studied—Nevada-Utah, Colorado, and Texas. The next steps for developing sedimentary geothermal resources vary due to differences in available data and resource uncertainties. Additional scopes of work are recommended for identified basins in these three regions.

15 GEOTHERMAL ENERGY↗

Grid Resilience Analysis on Geothermal District Heating and Cooling Implementation Alongside Four Existing Oil and Gas Wells in Tuttle, Oklahoma: Preprint

This study builds on the existing techno-economic and environmental life cycle assessments performed for a geothermal district heating and cooling system implementation in Tuttle Oklahoma with four existing oil and gas wells. Its resilience in meeting the peak annual heating and cooling loads of the district assuming a temporary disconnection from the electrical grid is assessed both qualitatively and quantitatively. Attributes of resilience and qualitative criteria established by Kolker et al. (2022) for geothermal district heating systems are applied to the proposed case to highlight its vulnerabilities. Results indicate that increasing the redundancy and diversity in the physical configuration of the distributional piping can considerably increase the system’s resilience. A quantitative assessment executed via the REopt tool predicts that the ancillary electricity required to power the geothermal system’s heating and cooling can be met by an onsite emergency diesel generator during times of grid outages for over 28 days.

district heating and cooling↗

Grid Resilience Analysis on Geothermal District Heating and Cooling Implementation Alongside Four Existing Oil and Gas Wells in Tuttle, Oklahoma

This study builds on the existing techno economic and environmental life cycle assessments performed for a geothermal district heating and cooling system implementation in Tuttle Oklahoma with four existing oil and gas wells. Its resilience in meeting the peak annual heating and cooling loads of the district assuming a temporary disconnection from the electrical grid is assessed both qualitatively and quantitatively. Attributes of resilience and qualitative criteria established by Kolker et al. (2022) for geothermal district heating systems are applied to the proposed case to highlight its vulnerabilities. Results indicate that increasing the redundancy and diversity in the physical configuration of the distributional piping can considerably increase the system's resilience. A quantitative assessment executed via the REopt tool predicts that the ancillary electricity required to power the geothermal system's heating and cooling can be met by an onsite emergency diesel generator during times of grid outages for over 28 days.

district heating and cooling↗

Real-Time Drilling Optimization System for Improved Overall Rate of Penetration and Reduced Cost Per Foot in Geothermal Drilling

The key to success in geothermal drilling is economic feasibility, and a major cost in the development of geothermal resources is the actual drilling of the wells. In this project, a real-time drilling optimization system for geothermal drilling was developed. The system couples three individual components while drilling. The first component is a drill stem vibration analysis model, the second is Mechanical Specific Energy (MSE) analyses, and the third is a detailed PDC Rate of Penetration (ROP) drill bit model for optimum RPM and WOB combinations. The benefit of the coupled system is that the range of WOB and RPM could be selected to avoid drill stem vibrations. Secondly, MSE is used as an efficiency measure and the detailed PDC drill bit model ensures the drill bit does not endure temperatures that exceed the temperature at which the PDC cutters experience accelerated wear. The new detailed PDC bit model is based on rock/bit interaction that physically tracks the PDC cutter wear flats as the bit drills ahead giving the capability to calculate the temperature being generated underneath the worn cutters to better advise on operational parameters to avoid accelerated cutter wear and failure and to ensure that operational parameters are applied so that overall ROP is maximized. By combining the drill stem vibrations and the detailed PDC bit cutter wear and “safe” non-accelerated cutter wear temperature and optimum ranges of operating parameters, it results in higher ROP and lower cost drilling. Single cutter PDC testing performed in different lithologies at Sandia was utilized to verify the PDC cutter forces and depth of cut for new and worn cutters. Based on single cutter PDC temperature modeling, verification using single cutter data from the testing done by National Oilwell Varco (NOV) was performed. Sandia’s Hard-Rock Drilling Facility (HRDF) was utilized to test different drill bit configurations with different cutter designs and wear status with different induced modes of vibration to obtain the critical bit RPM/WOB ranges resulting in ineffective drilling and low ROP. The collected test data were further used to verify and calibrate the full hole PDC ROP model that was developed based on single cutter interaction data. A full coupled drill stem vibration model was formulated and verified with geothermal field data from the Chocolate Mountain Aerial Gunnery Range (CMAGR). A graphical user interface (GUI) was developed using Tkinter library in the computer programming language Python, which integrates all the developed models in one system. The developed system consists mainly of the PDC ROP model, PDC bit wear model, PDC cutter temperature model, Mechanical Specific Energy (MSE) model, and drillstring vibration model integrated into one system. The developed system can be used for both, post well analysis and real-time optimization using different criteria such as ROP maximization or MSE minimization. The software uses Differential Evolution Algorithm (DEA) to find optimum values for operational parameters based on last foot drilled while avoiding the drillstring vibration and cutter temperature critical operating parameters.

15 GEOTHERMAL ENERGY↗

Nevada Play Fairway - Crescent Valley Geodatabase and Modeling Data

This package contains data and metadata for 2-meter temperature probe survey, gravity, slip dilation, XRD analyses, play fairway modeling, and ArcGIS geodatabase resources. This project focused on defining geothermal play fairways and development of a detailed geothermal potential map of a large transect across the Great Basin region (96,000 km2), with the primary objective of facilitating discovery of commercial-grade, blind geothermal fields (i.e. systems with no surface hot springs or fumaroles) and thereby accelerating geothermal development in this promising region.

15 GEOTHERMAL ENERGY↗