Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fluorescence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

An Event Reconstruction Method for the Telescope Array Fluorescence Detectors

We measure arrival directions, energies and mass composition of ultra-high energy cosmic rays with air fluorescence detector telescopes. The longitudinal profile of the cosmic ray induced extensive air shower cascade is imaged on focal plane of the telescope camera. Here, we show an event reconstruction method to obtain the primary information from data collected by the Telescope Array Fluorescence Detectors. In particular, we report on an ''Inverse Monte Carlo (IMC)'' method in which the reconstruction process searches for an optimum solution via repeated Monte Carlo simulations including characteristics of all detectors, atmospheric conditions, photon emission and scattering processes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-resolved laser-induced fluorescence measurement of ion and neutral dynamics in a Hall thruster during ionization oscillations

The paper presents spatially and temporally resolved laser-induced fluorescence (LIF) measurements of the xenon ion and neutral velocity distribution functions in a 400 W Hall thruster during natural ionization oscillations at 23 kHz, the so-called “breathing mode.” Strong fluctuations in measured axial ion velocity throughout the discharge current cycle are observed at five spatial locations and the velocity maxima appear in the low current interval. The spatio-temporal evolution of the ion velocity distribution function suggests a propagating acceleration front undergoing periodic motion between the thruster exit plane and ~1 cm downstream into the plume. In conclusion, the ion LIF signal intensity oscillates almost in phase with the discharge current, while the neutral fluorescence signal appears out of phase, indicating alternating intervals of strong and weak ionization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dual reactor for in situ/operando fluorescent mode XAS studies of sample containing low-concentration 3d or 5d metal elements

Transition metal elements are the most important elements of heterogeneous catalysts used for chemical and energy transformations. Many of these catalysts are active at a temperature higher than 400 °C. For a catalyst containing a 3d or 5d metal element with a low concentration, typically their released fluorescence upon the K-edge or L-edge adsorption of X-rays is collected for the analysis of chemical and coordination environments of these elements. However, it is challenging to perform in situ/operando X-ray absorption spectroscopy (XAS) studies of elements of low-energy absorption edges at a low concentration in a catalyst during catalysis at a temperature higher than about 450 °C. Here a unique reaction system consisting two reactors, called a dual reactor system, was designed for performing in situ or operando XAS studies of these elements of low-energy absorption edges in a catalyst at a low concentration during catalysis at a temperature higher than 450 °C in a fluorescent mode. This dual-reactor system contains a quartz reactor for preforming high-temperature catalysis up to 950 °C and a Kapton reactor remaining at a temperature up to 450 °C for collecting data in the same gas of catalysis. With this dual reactor, chemical and coordination environments of low-concentration metal elements with low-energy absorption edges such as the K-edge of 3d metals including Ti, V, Cr, Mn, Fe, Co, Ni, and Cu and L edge of 5d metals including W, Re, Os, Ir, Pt, and Au can be examined through first performing catalysis at a temperature higher than 450 °C in the quartz reactor and then immediately flipping the catalyst in the same gas flow to the Kapton reactor remained up to 450 °C to collect data. The capability of this dual reactor was demonstrated by tracking the Mn K-edge of the MnO x /Na 2 WO 4 catalyst during activation in the temperature range of 300-900 °C and catalysis at 850 °C.

47 OTHER INSTRUMENTATION↗

Analysis and comparison of ion-acoustic wave reflection using laser-induced fluorescence and Langmuir probes

The first laser-induced fluorescence measurements of ion acoustic wave reflection are presented. The experiment is performed in a multi-pole cylindrical chamber using a singly ionized argon (ArII) plasma produced by means of a hot cathode. Ion-acoustic waves are launched from a mesh antenna and reflected/absorbed by a biased, solid boundary (electrode). A comparison between the Langmuir probe and laser-induced fluorescence diagnostics is presented, with complementary Electric-field probe measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonlinear fluorescence spectroscopy of layered perovskite quantum wells

Interest in layered organohalide perovskites is motivated by their potential for use in optoelectronic devices. In these systems, the smallest and largest quantum wells are primarily concentrated near the glass and air interfaces of a film, thereby establishing a gradient in the average values of the bandgaps. It has been suggested that this layered architecture promotes the funneling of electronic excitations through space in a manner similar to light-harvesting processes in photosynthetic antennae. Whereas energy and charge transfer are difficult to distinguish by conventional transient absorption techniques, it has recently been shown that these competing relaxation mechanisms may be separately targeted with nonlinear fluorescence (NLFL) and photocurrent “action spectroscopies.” Here, we present perturbative rate functions to describe NLFL experiments conducted on layered perovskite systems. The formulas reproduce the patterns of resonances observed in experimental measurements and show how signatures of energy transfer manifest in two-dimensional spectra. Overall, this work suggests that NLFL spectroscopy may be used to fully reveal the trajectories of electronic excitations by correlating ultrafast energy transfer pathways to fluorescence emission from the thickest quantum wells.

Ouyang, Zhenyu↗

Continuous-wave planar laser induced fluorescence with a fast camera

We present planar, laser induced fluorescence (PLIF) measurements of the velocity-resolved distribution function of ions in a plasma using a modulated, narrow linewidth, continuous-wave laser. Plasma emission is acquired with a high frame rate camera, and the laser light is spread into a thin sheet so that an entire plane of the plasma is imaged at each interrogation wavelength. Fourier analysis is conducted on each pixel of the images to separate the modulated fluorescent emission from the background light. Argon ion temperatures and bulk flow maps are reported in a helicon plasma source, and standard single-point LIF measurements provide validation of the PLIF measurement.

47 OTHER INSTRUMENTATION↗

A new μ -high energy resolution fluorescence detection microprobe imaging spectrometer at the Stanford Synchrotron Radiation Lightsource beamline 6-2

In this report we describe a new synchrotron X-ray Fluorescence (XRF) imaging instrument with an integrated High Energy Fluorescence Detection X-ray Absorption Spectroscopy (HERFD-XAS) spectrometer at the Stanford Synchrotron Radiation Lightsource at beamline 6-2. The X-ray beam size on the sample can be defined via a range of pinhole apertures or focusing optics. XRF imaging is performed using a continuous rapid scan system with sample stages covering a travel range of 250 × 200 mm 2 , allowing for multiple samples and/or large samples to be mounted. The HERFD spectrometer is a Johann-type with seven spherically bent 100 mm diameter crystals arranged on intersecting Rowland circles of 1 m diameter with a total solid angle of about 0.44% of 4π sr. A wide range of emission lines can be studied with the available Bragg angle range of ~64.5°–82.6°. With this instrument, elements in a sample can be rapidly mapped via XRF and then selected features targeted for HERFD-XAS analysis. Furthermore, utilizing the higher spectral resolution of HERFD for XRF imaging provides better separation of interfering emission lines, and it can be used to select a much narrower emission bandwidth, resulting in increased image contrast for imaging specific element species, i.e., sparse excitation energy XAS imaging. This combination of features and characteristics provides a highly adaptable and valuable tool in the study of a wide range of materials.

47 OTHER INSTRUMENTATION↗

Planar laser induced fluorescence mapping of a carbon laser produced plasma

We present measurements of ion velocity distribution profiles obtained by laser induced fluorescence (LIF) on an explosive laser produced plasma. The spatiotemporal evolution of the resulting carbon ion velocity distribution was mapped by scanning through the Doppler-shifted absorption wavelengths using a tunable, diode-pumped laser. The acquisition of these data was facilitated by the high repetition rate capability of the ablation laser (1 Hz), which allowed for the accumulation of thousands of laser shots in short experimental times. By varying the intensity of the LIF beam, we were able to explore the effects of fluorescence power against the laser irradiance in the context of evaluating the saturation vs the non-saturation regime. The small size of the LIF beam led to high spatial resolution of the measurement compared to other ion velocity distribution measurement techniques, while the fast-gate operation mode of the camera detector enabled the measurement of the relevant electron transitions.

Instruments & Instrumentation↗

Chemically sensitive fluorescence imaging of colliding microdroplets

Here, we present a simple optical capability for generating spatially resolved chemical concentration maps of mixing fluids using a chemically sensitive dye, 1-hydroxy-3,6,8-pyrenetrisulfonic acid, detected by planar laser induced fluorescence. To demonstrate an application of this capability, we investigate the collision and mixing of a pair of microdroplets in air. The two microdroplets are composed of different fluids, methanol and water, with the dye initially in the methanol droplet. When the droplets collide and mixing process develops, the fluorescence of the dye shifts from blue to green as the solvent environment changes. A series of spectral-temporal images of the collision and subsequent mixing are recorded, from which we extract the distribution of the two intermixing droplet species reflected in the spatially resolved dye spectra. Images reveal material transfer between droplets in both coalescing and non-coalescing droplet collisions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Charge transfer as a mechanism for chlorophyll fluorescence concentration quenching

Highly concentrated solutions of chlorophyll display rapid fluorescence quenching. The same devastating energy loss is not seen in photosynthetic light-harvesting antenna complexes, despite the need for chromophores to be in close proximity to facilitate energy transfer. A promising, though unconfirmed mechanism for the observed quenching is energy transfer from an excited chlorophyll monomer to a closely associated chlorophyll pair that subsequently undergoes rapid nonradiative decay to the ground state via a short-lived intermediate charge-transfer state. In this work, we make use of newly emerging fast methods in quantum chemistry to assess the feasibility of this proposed mechanism. We calculate rate constants for the initial charge separation, based on Marcus free-energy surfaces extracted from molecular dynamics simulations of solvated chlorophyll pairs, demonstrating that this pathway will compete with fluorescence (i.e., drive quenching) at experimentally measured quenching concentrations. We show that the rate of charge separation is highly sensitive to interchlorophyll distance and the relative orientations of chromophores within a quenching pair. We discuss possible solvent effects on the rate of charge separation (and consequently the degree of quenching), using the light-harvesting complex II (LH2) protein from rps. acidophila as a specific example of how this process might be controlled in a protein environment. Crucially, we reveal that the LH2 antenna protein prevents quenching, even at the high chlorophyll concentrations required for efficient energy transfer, by restricting the range of orientations that neighboring chlorophyll pairs can adopt.

59 BASIC BIOLOGICAL SCIENCES↗

Spatially resolved charge-transfer kinetics at the quantum dot–microbe interface using fluorescence lifetime imaging microscopy

Integrating the optoelectronic properties of quantum dots (QDs) with biological enzymatic systems to form microbe-semiconductor biohybrids offers promising prospects for both solar-to-chemical conversion and light-modulated biochemical processes. Developing these nano–bio hybrid systems necessitates a deep understanding of charge-transfer dynamics at the nano–bio interface. Photoexcited carrier transfer from QDs to microbes is driven by complex interactions, with emerging insights into the relevant thermodynamic and kinetic factors. The heterogeneities of both microbes and QD ensembles pose significant challenges in mechanistic understanding, which is critical for designing advanced nano–bio hybrids. We used fluorescence lifetime imaging microscopy to analyze charge transfer between a CdSe QD film andShewanella oneidensismicrobes. We correlated the spatiotemporal fluorescence data with an analytical model. Our analysis revealed two distinct distributions of QD de-excitation pathways. The characteristics of these distributions: 1) a faster transfer rate ( k ¯ E T 1 = 1.5 10 9 s - 1 ), with a lower acceptor number ( N ¯ a 1 = 0.03 ) and 2) a slower transfer rate ( k ¯ E T 2 = 4.1 10 8 s - 1 ) with a higher acceptor number ( N ¯ a 2 = 0.18 ). We assign these distributions to the indirect and direct electron transfer mechanisms, respectively. Our findings demonstrate how spectroscopic imaging can uncover fundamental electron transfer mechanisms at complex interfaces, offering valuable design principles for future nano–bio hybrids.

Science & Technology - Other Topics↗

LCLS in—photon out: fluorescence measurement of neon using soft x-rays

Here, we measured the fluorescence photon yield of neon upon soft x-ray ionization (~1200 eV) from the x-ray free-electron laser at Linac Coherent Light Source, and demonstrated the usage of a grazing incidence spectrometer with a variable line spacing grating to perform x-ray fluorescence spectroscopy on a gas phase system. Our measurements also allowed us to estimate the focal size of the beam from the theoretical description developed, in terms of the rate equation approximation accounting for photoionization shake off of neutral neon and double auger decay of single core holes.

74 ATOMIC AND MOLECULAR PHYSICS↗

2D imaging of absolute methyl concentrations in nanosecond pulsed plasma by photo-fragmentation laser-induced fluorescence

The methyl radical plays a central role in plasma-assisted hydrocarbon chemistry but is challenging to detect due to its high reactivity and strongly pre-dissociative electronically excited states. In this work, we report the development of a photo-fragmentation laser-induced fluorescence (PF-LIF) diagnostic for quantitative 2D imaging of methyl profiles in a plasma. This technique provides temporally and spatially resolved measurements of local methyl distributions, including in near-surface regions that are important for plasma-surface interactions such as plasma-assisted catalysis. The technique relies on photo-dissociation of methyl by the fifth harmonic of a Nd:YAG laser at 212.8 nm to produce CH fragments. These photofragments are then detected with LIF imaging by exciting a transition in the B-X(0, 0) band of CH with a second laser at 390 nm. Fluorescence from the overlapping A-X(0, 0), A-X(1, 1), and B-X(0, 1) bands of CH is detected near 430 nm with the A-state populated by collisional B-A electronic energy transfer. This non-resonant detection scheme enables interrogation close to a surface. The PF-LIF diagnostic is calibrated by producing a known amount of methyl through photo-dissociation of acetone vapor in a calibration gas mixture. We demonstrate PF-LIF imaging of methyl production in methane-containing nanosecond pulsed plasmas impinging on dielectric surfaces. Absolute calibration of the diagnostic is demonstrated in a diffuse, plane-to-plane discharge. Measured profiles show a relatively uniform distribution of up to 30 ppm of methyl. Relative methyl measurements in a filamentary plane-to-plane discharge and a plasma jet reveal highly localized intense production of methyl. The utility of the PF-LIF technique is further demonstrated by combining methyl measurements with formaldehyde LIF imaging to capture spatiotemporal correlations between methyl and formaldehyde, which is an important intermediate species in plasma-assisted oxidative coupling of methane.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fluorescence time profile measurement of LAB based liquid scintillator in response to medium relativistic ion particles

Liquid scintillator is widely used in particle physics experiments due to its high light yield, good timing resolution, scalability and low cost. Certain liquid scintillators exhibit pulse shape discrimination capabilities because of difference in fluorescence timing properties induced by different particles. Its fluoresence timing properties have been measured mostly for radioactive decay sources at MeV energies. Here, we present a novel measurement of fluorescence time properties of Linear Alkyl Benzene (LAB) based liquid scintillator in response to high-energy ions of hydrogen (Z = 1), helium (Z = 2) and krypton at around 200–300 MeV/u for the first time. We compared the results to those from radioactive sources and observed a distinct dE / dX dependence, regardless of the particle type. These findings are essential for physics searches such as the diffuse supernova neutrino background in large liquid scintillator detectors like JUNO, and are also critical towards understanding the underlying scintillation timing mechanism.

Ion identification systems↗

Fluorescent and Bioluminescent Reporter Mouse-Adapted Ebola Viruses Maintain Pathogenicity and Can Be Visualized in Vivo

Abstract Ebola virus (EBOV) causes lethal disease in humans but not in mice. Here, we generated recombinant mouse-adapted (MA) EBOVs, including 1 based on the previously reported serially adapted strain (rMA-EBOV), along with single-reporter rMA-EBOVs expressing either fluorescent (ZsGreen1 [ZsG]) or bioluminescent (nano-luciferase [nLuc]) reporters, and dual-reporter rMA-EBOVs expressing both ZsG and nLuc. No detriment to viral growth in vitro was seen with inclusion of MA-associated mutations or reporter proteins. In CD-1 mice, infection with MA-EBOV, rMA-EBOV, and single-reporter rMA-EBOVs conferred 100% lethality; infection with dual-reporter rMA-EBOV resulted in 73% lethality. Bioluminescent signal from rMA-EBOV expressing nLuc was detected in vivo and ex vivo using the IVIS Spectrum CT. Fluorescent signal from rMA-EBOV expressing ZsG was detected in situ using handheld blue-light transillumination and ex vivo through epi-illumination with the IVIS Spectrum CT. These data support the use of reporter MA-EBOV for studies of Ebola virus in animal disease models.

Immunology↗

X-ray fluorescence mapping of brain tissue reveals the profound extent of trace element dysregulation in stroke pathophysiology

Abstract The brain is a privileged organ with regard to its trace element composition and maintains a robust barrier system to sequester this specialized environment from the rest of the body and the vascular system. Stroke is caused by loss of adequate blood flow to a region of the brain. Without adequate blood flow ischaemic changes begin almost immediately, triggering an ischaemic cascade, characterized by ion dysregulation, loss of function, oxidative damage, cellular degradation, and breakdown of the barrier that helps maintain this environment. Ion dysregulation is a hallmark of stroke pathophysiology and we observe that most elements in the brain are dysregulated after stroke. X-ray fluorescence-based detection of physiological changes in the neurometallome after stroke reveals profound ion dysregulation within the lesion and surrounding tissue. Not only are most elements significantly dysregulated after stroke, but the level of dysregulation cannot be predicted from a cell-level description of dysregulation. X-ray fluorescence imaging reveals that the stroke lesion retains <25% of essential K+ after stroke, but this element is not concomitantly elevated elsewhere in the organ. Moreover, elements like Na+, Ca2+, and Cl− are vastly elevated above levels available in normal brain tissue (>400%, >200%, and >150%, respectively). We hypothesize that weakening of the blood–brain barrier after stroke allows elements to freely diffuse down their concentration gradient so that the stroke lesion is in equilibrium with blood (and the compartments containing brain interstitial fluid and cerebrospinal fluid). The change observed for the neurometallome likely has consequences for the potential to rescue infarcted tissue, but also presents specific targets for treatment.

Biochemistry & Molecular Biology↗

Energy shift of Fe-K fluorescence lines due to low ionization demonstrated with XRISM in Centaurus X-3

The Fe K$\alpha$ fluorescence line at 6.4 keV is a powerful probe of cold matter surrounding X-ray sources and has been widely used in various astrophysical contexts. The X-ray microcalorimeter spectrometer onboard XRISM can measure line shifts with unprecedented precision of ${\sim }$0.2 eV, equivalent to a line-of-sight velocity of ${\sim }$10 km s$^{-1}$. At this level of accuracy, however, several factors that influence the line energy must be carefully considered prior to astrophysical interpretation. One such important factor is the ionization degree, Fe$^{q+}$. The K$\alpha$ line shifts redward by ${\sim }$4 eV as q increases from 0 (neutral) to 8 (Ar-like). Additionally, the accompanying Fe K$\beta$ line at 7.06 keV shifts blueward by ${\sim }$30 eV from $q=0$ to 8. We demonstrate that this effect is actually observable in the XRISM data of the high-mass X-ray binary Centaurus X-3 (Cen X-3). We advocate that the differential energy shift between the K$\alpha$ and K$\beta$ line provides a robust estimate of q by decoupling from other effects that shift the two lines in the same direction. We derived $q \sim 5$ (Sc-like) for the fluorescing matter by comparing the observation with atomic structure calculations of our own and in the literature. By accounting for the derived charge state and the corresponding shift in the rest-frame line energy, we made corrections for this effect and reached a consistent residual shift among the K$\alpha$, K$\beta$, and the optical measurement attributable to the systemic velocity of the system. Consequently, we obtained a new constraint on the location of the cold matter. This ionization effect needs to be assessed in all use cases of the Fe K$\alpha$ line shift beyond Cen X-3, and the proposed metric is generally applicable to all of them.

Astronomy and AstroPhysics↗

Fluorescence intensity monitors as intensity and beam-position diagnostics for X-ray free-electron lasers

For LCLS-II, a fluorescence intensity monitor for the non-invasive, pulse-by-pulse normalization of experiments has been developed. A prototype diagnostic was constructed with a microchannel plate assembly and two photodiodes. The diagnostic was then installed in the LCLS SXR instrument Kirkpatrick–Baez mirror chamber with the detectors located above the vertically reflecting mirror. The linearity, noise and position sensitivity of the detectors have been characterized. The photodiode responsivity is suitable for high pulse energies. The microchannel plate detector shows sufficient responsivity over a wide range of pulse energies. The relative signal from the two photodiodes provides a sensitive measure of the X-ray beam position. The fluorescence intensity monitor provides intensity normalization while being compatible with high incident power, a 0.93 MHz repetition rate and ultra-high vacuum.

47 OTHER INSTRUMENTATION↗