Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FREEZING OUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Seasonal Variations of Arctic Low-Level Clouds and its Linkage to Sea Ice Seasonal Variations

Using CALIPSO-CloudSat-Clouds and the Earth's Radiant Energy System (CERES)-Moderate Resolution Imaging Spectrometer (MODIS) (C3M) dataset, this study documents the seasonal variation of sea ice, cloud, and related atmospheric properties in the Arctic region (70°N–82°N) during the period 2007-2010. The surface type stratification used reveals the surface type influence on the Arctic cloud liquid water path (LWP)seasonality. Four surface types are defined: i) Permanent Ocean, ii) Land, iii) Permanent Ice, and iv) Transient Sea Ice. The Transient Ice regions are further divided into sub-regions according to the onset dates of melt/freeze season. Results show that the sea ice cover has no significant direct influence on the seasonal variation of the water vapor in the lower troposphere and the low-level cloud LWP. Rather, the role played by sea ice appear indirect by modifying the surface temperature response to increased solar insolation and influencing lower tropospheric stability (LTS). The results suggest that the combined increase in atmospheric water vapor due to warming air temperatures and the weakening of the inversion strength that governs the seasonal structure of cloud LWP. Over Transient Ice regions, the results suggest that the May peak in LWP coincides with a decrease in LTS and that is insensitive to melt and freeze onset. Variations in melt and freeze onset set are found to influence probably distribution of cloud LWP where regions of earlier melt and later freeze onset how a higher likelihood of larger values.

Yueyue Yu↗

New Estimates of Ice and Oxygen Fluxes Across the Entire Lid of Lake Vostok From Observations of Englacial Radio Wave Attenuation

Over deep Antarctic subglacial lakes, spatially varying ice thickness and the pressure‐dependent melting point of ice result in distinct areas of melting and freeze‐on at the ice‐water interface, that is, at the lake lid. These ice mass fluxes drive lake circulation and, because basal Antarctic ice contains air clathrate, affect the input of oxygen to the lake, with implications for subglacial life. Inferences of rates of melting and freeze‐on, that is, accretion rates, from radar layer tracking and geodesy are limited in spatial coverage and resolution. Here we develop a new method to estimate accretion rate, and the resulting oxygen input at a lake lid, using airborne radar data over Lake Vostok together with ice‐temperature and chemistry data from the Vostok ice core. Because the lake lid is a coherent reflector of known reflectivity (at our radar frequency), we can infer depth‐averaged radio wave attenuation in the ice, with a spatial resolution of ~1 km along flight lines. Spatial variation in attenuation depends mostly on variation in ice temperature near the lid, which in turn varies strongly with ice mass flux at the lid. We model ice temperature versus depth with ice mass flux as a parameter, thus linking that flux to observed depth‐averaged attenuation. The resulting map of melt and accretion rates independently reproduces features known from earlier studies but now covers the entire lid. We find that freeze‐on is dominant when integrated over the lid, with an ice imbalance of 0.05 to 0.07 cu.km/year, which is robust against uncertainties.

Dale P. Winebrenner↗

Large-Drop Ice Accretion Test Results for a Large Scale Swept Wing Model

In-flight icing is an important consideration that affects aircraft design, performance and safety. Newer regulations combined with increasing demand to reduce fuel burn, emissions and noise are driving a need for improvements in icing simulation capability. To that end, this paper presents the results of ice accretion testing conducted in the NASA Icing Research Tunnel on a large swept wing section typical of a modern commercial transport. The model was based upon a section of the Common Research Model wing at the 64% semispan station with a streamwise chord length of 136 in. The test conditions were developed with an icing scaling analysis to generate similar conditions for a small MVD = 25 μm and a large MVD = 110 μm. A series of tests were conducted over a range of total temperature from -23.8 ˚C to -1.4 ˚C with all other conditions held constant. The results for the small MVD cloud conditions were consistent with previous work and showed the changing ice morphology from rime ice at colder temperatures to highly 3D scallop ice in the range of -8.7 ˚C to -3.8 ˚C. The results for the large MVD cloud conditions exhibited some differences in the ice accretion morphology from the small MVD conditions. Scallop-like ice features were observed at total temperature of -3.8˚C. The large MVD ice accretion at lower temperatures tended to be smoother than the corresponding ice accretion for small MVD. The thickness of the main ice shape tended to be larger for the small MVD conditions compared to the corresponding large MVD ice shape while the latter had more ice farther downstream. The measured ice mass was approximately equal between the corresponding small and large MVD ice shapes up to a freezing fraction of 0.6. For higher freezing fraction, the large MVD ice shapes weighed more. Cloud MVD variation from 50 μm to 230 μm while holding the scaling parameters constant resulted in very minor differences in the ice shapes, mostly in the upper and lower surface chordwise extents. Ice volume was computed from 3D scan data and used to calculate a ratio of ice mass to volume. The resulting values were in the range of 240 to 455 Kg/m3. While this is consistent with analogous values previously reported in the literature, more data are needed to determine a specific trend in this ratio as a function of freezing fraction and the corresponding governing physical phenomena. This work has resulted in a significant experimental database of ice accretion for small and large MVD conditions applicable to large-scale swept wings.

Icing↗

Large-Drop Ice Accretion Test Results for a Large Scale Swept Wing Section

In-flight icing is an important consideration that affects aircraft design, performance and safety. Newer regulations combined with increasing demand to reduce fuel burn, emissions and noise are driving a need for improvements in icing simulation capability. To that end, this paper presents the results of ice accretion testing conducted in the NASA Icing Research Tunnel on a large swept wing typical of a modern commercial transport. The model was based upon a section of the Common Research Model wing at the 64% semispan station with a streamwise chord length of 136 in. The test conditions were developed with an icing scaling analysis to generate similar conditions for a small MVD = 25 μm and a large MVD = 110 μm. A series of tests were conducted over a range of total temperature from -23.8 ˚C to -1.4 ˚C with all other conditions held constant. The results for the small MVD cloud conditions were consistent with previous work and showed the changing ice morphology from rime ice at colder temperatures to highly 3D scallop ice in the range of -8.7 ˚C to -3.8 ˚C. The results for the large MVD cloud conditions exhibited some differences in the ice accretion morphology. Scallop-like ice features were observed at total temperature of -3.8˚C. The large MVD ice accretion at lower temperatures tended to be smoother than the corresponding ice accretion for small MVD. The thickness of the main ice shape tended to be larger for the small MVD conditions compared to the corresponding large MVD ice shape while the latter had more ice farther downstream. The measured ice mass was approximately equal between the corresponding small and large MVD ice shapes up to a freezing fraction of 0.6. For higher freezing fraction, the large MVD ice shapes weighed more. Cloud MVD variation from 50 μm to 230 μm while holding the scaling parameters constant resulted in very minor differences in the ice shapes, mostly in the upper and lower surface chordwise extents. Ice volume was computed from 3D scan data and used to calculate a ratio of ice mass to volume. The resulting values were in the range of 240 to 455 Kg/m3. While this is consistent with analogous values previously reported in the literature, more data are needed to determine a specific trend in this ratio as a function of freezing fraction and the corresponding governing physical phenomena. This work has resulted in a significant experimental database of ice accretion for small and large MVD conditions applicable to large-scale swept wings.

Icing↗

Power Hibernation for Low-Cost Solar Powered Lunar Missions

Because the surface of the Moon drops to cryogenic temperatures, no solar-powered lunar spacecraft have reliably operated beyond a single lunar day. Passive thermal control cannot keep a spacecraft sufficiently warm for the 354-hour lunar night, and active thermal control requires a dramatic increase in battery mass at the expense of payload mass. Extreme conditions seen on the lunar surface suggest a radioisotope solution is ideal, but mass, cost, and schedule are inconsistent with low-cost frequent flight intent of the commercial lunar payload services (CLPS) program. To solve the issue of lunar night survivability without radioisotope sources of power and heat, a lunar power hibernation approach is being developed at the Glenn Research Center, which exploits the ability of common 18650 Lithium-ion cells to passively survive cryogenic freeze-thaw cycles and recover without apparent performance degradation. A key aspect of this hibernation approach is the use of cryogenically operable electronics that safely manage the restoration of the battery thermal environment at lunar dawn. A spacecraft utilizing this strategy will operate into the lunar night on batteries until the state of charge or spacecraft temperature reaches a predetermined threshold. At this point, systems are shut down and the battery is isolated from the main bus to prevent charge or discharge during the freezing and thawing transitions. The system remains passive until lunar dawn, where temperatures can reach as low as 50 K. All electronics must be tolerant to these conditions. When the solar arrays are finally illuminated at lunar dawn, the main bus power electronics will initiate a “cold start” and begin regulating array power. The main bus electronics must be designed to operate at cryogenic temperatures. Array power is used to warm the battery and passive electronics back to operational temperatures. Once batteries are returned to normal temperatures, diagnostics and precharging is performed, as needed, and the battery is reconnected. The overall spacecraft system reboots and returns to nominal operations until lunar night returns. To assure that we can develop batteries suited for many hibernation freeze/thaw cycles, STMD Space Technology Research Grant Program (STRG) has selected two principal investigators that will thoroughly characterize of the Li-ion cell through the freeze-thaw process, investigate degradation mechanisms, and identify potential diagnostic techniques. STMD STRG is also funding an investigation of Gallium-Nitride semiconductors for cryogenic power applications. This work includes physics-informed modeling that considers cryogenic conductivity, carrier mobility, and quantum effects that govern semiconductor performance at cryogenic temperatures. These models can enable engineers to develop accurate cryogenic simulation models that assist in the design of power controls stable over the entire lunar surface temperature range. Meanwhile, Glenn is performing cryogenic testing of batteries and electronics, establishing design guidelines for power applications in extreme cold lunar environment, and potentially developing a hibernation technology demonstrator. The hibernation approach will enable low-cost lunar robotic missions to extend their operating lifetime to many months while minimizing development costs and impact on payload capacity. The need for cryogenically operable electronics is restricted to only main bus power and battery controls, as the majority of systems simply need to passively tolerate cryogenic temperatures. This allows developers to continue to exploit the cost savings of legacy and COTS hardware with minimum modification. For these reasons, lunar power hibernation is a viable near-term solution for lunar night survivability for solar powered commercial landers.

Space power↗

High resolution neutron imaging of water in the polymer electrolyte membrane

To achieve a deeper understanding of water transport and performance issues associated with water management, we have conducted in situ water examinations to help understand the effects of components and operation. High Frequency Resistance (HFR), AC Impedance and neutron radiography were used to measure water content in operating fuel cells under various operating conditions. Variables examined include: sub-freezing conditions, inlet relative humidities, cell temperature, current density and response transients, different flow field orientations and different component materials (membranes, GDLs and MEAs). Quantification of the water within the membrane was made by neutron radiography after equilibration to different humidified gases, during fuel cell operation and in hydrogen pump mode. The water content was evaluated in bare Nafion{reg_sign} membranes as well as in MEAs operated in both fuel cell and H{sub 2} pump mode. These in situ imaging results allow measurement of the water content and gradients in the PEFC membrane and relate the membrane water transport characteristics to the fuel cell operation and performance under disparate materials and operational combinations. Flow geometry makes a large impact on MEA water content. Higher membrane water with counter flow was measured compared with co-flow for sub-saturated inlet RH's. This correlates to lower HFR and higher performance compared with co-flow. Higher anode stoichiometry helps remove water which accumulates in the anode channels and GDL material. Cell orientation was measured to affect both the water content and cell performance. While membrane water content was measured to be similar regardless of orientation, cells with the cathode on top show flooding and loss of performance compared with similarly operated cells with the anode on top. Transient fuel cell current measurements show a large degree of hysteresis in terms of membrane hydration as measured by HFR. Current step transients from 0.01 A cm{sup -2} to 0.68 A cm{sup -2} consistently show PEM wetting occurring within 5 to 20 sec. Whereas the PEM drying response to the reverse step transient of 0.68 A cm{sup -2} to 0.01 A cm{sup -2}, takes several minutes. The observed faster wetting response is due to reaction water being produced in the cathode and back diffusing into the membrane. The slower PEM drying is due to the water slowly being removed out of the wetted GDLs. This rate of removal of water and hence the PEM hydration level was found to be influenced strongly by the PTFE loadings in the GDL substrate and Microporous layer (MPL). The drying of the membrane is influenced by both the anode and cathode GDL PTFE loadings. Lower PTFE loading in the anode GDL leads to better membrane hydration probably due to the easier incorporation of water from the anode GDL into the membrane. Similarly a lower PTFE loading in the cathode GDL also results in better membrane hydration probably due to the better water retention properties (less hydrophobic) of this GDL. Fuel cells operated isothermal at sub-freezing temperatures show gradual cell performance decay over time and eventually drops to zero. AC impedance analysis indicates that losses are initially due to increasing charge transfer resistance. After time, the rate of decay accelerates rapidly due to mass transport limitations. High frequency resistance also increases over time and is a function of the initial membrane water content. These results indicate that catalyst layer ice formation is influenced strongly by the MEA and is responsible for the long-term degradation of fuel cells operated at sub-freezing temperatures. Water distribution measurements indicate that ice may be fonning mainly in the GDLs at -10 C but are concentrated in the catalyst layer at -20 C.

08 HYDROGEN↗

Assessment on the Practicality of Off-the-Shelf Valves for Use in Molten Salt

From the mid to late 1960s, the Molten Salt Reactor Experiment (MSRE) was operated at Oak Ridge National Laboratory (ORNL). The MSRE design is unique: instead of standard valves, freeze valves were used to isolate the fluid salt as needed. While standard valves were considered for use in the MSRE, key design challenges (leaking, corrosion, valve alignment, and cold-welding, etc.) were all avoided by choosing a freeze type valve. While the freeze valves were integral to the MSRE’s success, they do not respond quickly, and they are not capable of throttling flow: two key features important to commercial operation and test facilities. More than half a century after the MSRE’s inception, design and manufacturing capabilities have changed. There is a renewed interest in molten salts for energy storage in nuclear and concentrated solar power. Therefore, there is a strong desire to have a functioning valve that can be obtained off the shelf or with minimal modification to a custom valve. This research addresses the known challenges associated with valve selection in fluoride salts, provides guidelines as to potential options for selection of a valve, and uses these guidelines to select a valve for testing in ORNL’s Liquid Salt Test Loop (LSTL).

Howard, Trevor↗

Water desalination system and method for fast cooling saline water using turbines

A desalinating system and method is disclosed. The desalination system comprises using a turbo freeze or fast-cooling process to freeze saline water droplets and separate salt crystals from pure water crystals, wherein said system provides for simultaneous injection of saline water droplets and a chilled refrigerant into a freezing chamber at a slip velocity sufficient to reduce the size of the saline water droplets to an optimal diameter.

Lissianski, Vitali Victor↗

Incredibility of a Postulated Criticality Event for Enriched Uranyl Nitrate Storage

At the H-Canyon outside facilities, highly enriched uranyl nitrate solutions collected from leaks or during deliberate maintenance activities is collected into 5-gallon polyethylene bottles. The current criticality safety evaluation for the facility postulates that a criticality event is possible if the solutions are allowed to concentrate through evaporation, freezing, storing multiple bottles in a geometrically unfavorable array, or any combination of these conditions. Using chemical data on uranyl nitrate freezing from Savannah River National Laboratory, protected limits on concentration and enrichment, and normal operational restrictions, criticality was shown to be incredible under all normal and credible abnormal conditions. A bounding normal solution is analyzed under normal conditions and shown to be substantially subcritical. A bounding credible abnormal solution is defined as 9.2 g U{sup 235}/L and 73 wt. % enriched and 0 M excess nitric acid. The concentration and enrichment are limitations already protected by the facility for other processes. Because acidity is not specifically restricted, the most reactive lower bound is selected. The credible abnormal worst placement is in a concrete basin reflected on three sides. There the bottle(s) would be subject in the worst cases to flooding (full water reflection) and postulated concentration through evaporation or freezing. Computational modeling was performed using KENOVI in the SCALE 6.1 code package. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of Heaters on Molten Salt Reactors Dynamics

Recently, there has been renewed interest in the Molten Salt Reactor (MSR) concept. This interest is mainly due to its advantages over Light Water Reactors (LWRs). Among these advantages are the flexibility in the fuel choice and the possibility to burn actinides [1]. Currently, two molten research reactors are under development. A 2 MW molten salt experimental reactor has been constructed and is planned for operation in China. A 1 MW Molten Salt Research Reactor is under construction in the United States [2]. Thus, Research and Development (R&D) programs are needed for the MSR technology. Reactor dynamics studies are crucial safety evaluation studies. The development of reactor dynamics tools for MSRs started during the Molten Salt Reactor Program (MSRP) at ORNL, focusing on the Molten Salt Reactor Experiment (MSRE) [3]. Although various dynamic simulation tools are available, R&D efforts to develop specialized tools for MSRs are still ongoing [4]. The primary motivation for this interest is the goal of commercializing MSRs. Developing a dynamics tool for MSRs is crucial for analyzing their safety and supporting their demonstration efforts. A crucial safety issue in MSRs is ensuring that the fuel salt in the primary loop remains molten. This concern becomes particularly important when the reactor operates at lower power levels. Most chloride and fluoride salts used as fuel have a melting point of approximately 450 °C [5]. Therefore, maintaining fuel salt temperatures above this melting point is essential to prevent it from freezing. Freezing of the fuel salt can lead to volume expansion, potentially causing damage to reactor components [6]. Moreover, it can create local blockages within fuel salt channels, reducing cooling efficiency and resulting in hot spots [7]. Various methods can prevent fuel salt from freezing at low power levels. These include reducing the fuel mass flow rate in the primary loop, decreasing heat exchange between the primary and secondary loops in the reactor, and using electric fuel salt heaters. Reducing the mass flow rate of fuel salt in the primary loop can increase the fuel salt transit time in the core, enhancing heat production and increasing temperature. However, it can potentially lead to challenges. These include increasing the potential for fuel salt deposition on the reactor channel walls [8], affecting the overall heat transfer processes. Thus, alternative methods should be used [9]. This research investigates the effects of fuel salt heaters on the dynamics and stability during MSR operation. The investigation includes studying the reactor stability with the fuel salt heaters on and off. In addition, the reactor response to transients is compared with and without the operation of fuel salt heaters. These transients include reactivity insertion, primary and secondary pump failure, and heat sink temperature increase. The results of the reactivity insertion transient are presented in the summary.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ice Nucleation and Droplet Formation by Bare and Coated Black Carbon Particles

We have studied the ice formation at heterogeneous and homogeneous temperatures, as well as droplet activation and hygroscopicity of soot particles of variable size and composition. Coatings of adipic, malic, and oleic acid were applied to span a relevant range of solubility, and both uncoated and oleic acid coated soot particles were exposed to ozone to simulate atmospheric oxidation. The results are interpreted in terms of onset ice nucleation with a comparison to a well characterized mineral dust particle that acts as an efficient ice nucleus, as well as particle hygroscopicity. At 253K and 243K, we found no evidence of heterogeneous ice nucleation occurring above the level of detection for our experimental conditions. Above water saturation, droplet formation was observed. At 233K, we observe the occurrence of homogeneous ice nucleation for all particles studied. Coatings also did not significantly alter the ice nucleation behavior of soot particles, but aided in the uptake of water. Hygroscopicity studies confirmed that pure soot particles were hydrophobic, and coated soot particles activated as droplets at high water supersaturations. A small amount of heterogeneous ice nucleation either below the detection limit of our instrument or concurrent with droplet formation and/or homogeneous freezing cannot be precluded, but we are able to set limits for its frequency. We conclude from our studies that both uncoated and coated soot particles are unlikely to contribute to the global budget of heterogeneous ice nuclei at temperatures between 233K and 253K.

58 GEOSCIENCES↗

Competing magnetic ground states in the A-site layer-ordered manganite La[subscript 1−x]Ba[subscript 1+x]Mn[subscript 2]O[subscript 6]

Using neutron and x-ray diffraction, we report the discovery of competing ground states near a multicritical point in A-site layer-ordered La{sub 1-x}Ba{sub 1+x}Mn{sub 2}O{sub 6} materials. We demonstrate the dual effects of deliberate disorder on the system's stability, the freezing of the competing states, and the drastic reduction in magnetic fields required for the suppression of charge- and orbital-ordered phases. Our work suggests that quenched disorder is not the primary reason for phase separation and magnetoresistance and that increased doping leads to electronic phase separation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ice-nucleating particles in precipitation samples from the Texas Panhandle

Ice-nucleating particles (INPs) influence the formation of ice crystals in clouds and many types of precipitation. This study reports unique properties of INPs collected from 42 precipitation samples in the Texas Panhandle region from June 2018 to July 2019. We used a cold stage instrument called the West Texas Cryogenic Refrigerator Applied to Freezing Test system to estimate INP concentrations per unit volume of air (nINP) through immersion freezing in our precipitation samples with our detection capability of >0.006 INP L -1 . A disdrometer was used for two purposes: (1) to characterize the ground-level precipitation type and (2) to measure the precipitation intensity as well as size of precipitating particles at the ground level during each precipitation event. While no clear seasonal variations of n INP values were apparent, the analysis of yearlong ground-level precipitation observation as well as INPs in the precipitation samples showed some INP variations, e.g., the highest and lowest n INP values at -25°C both in the summer for hail-involved severe thunderstorm samples (3.0 to 1130 INP L -1 ), followed by the second lowest at the same temperature from one of our snow samples collected during the winter (3.2 INP L -1 ). Furthermore, we conducted bacteria community analyses using a subset of our precipitation samples to examine the presence of known biological INPs. In parallel, we also performed metagenomics characterization of the bacterial microbiome in suspended ambient dust samples collected at commercial open-lot livestock facilities (cattle feedyards hereafter) in the Texas Panhandle (i.e., the northernmost counties of Texas, also known as “West Texas”) to ascertain whether local cattle feedyards can act as a source of bioaerosol particles and/or INPs found in the precipitation samples. Some key bacterial phyla present in cattle feedyard samples appeared in precipitation samples. However, no known ice nucleation active species were detected in our samples. Overall, our results showed that cumulative n INP in our precipitation samples below -20°C could be high in the samples collected while observing > 10 mm h -1 precipitation with notably large hydrometeor sizes and an implication of cattle feedyard bacteria inclusion.

54 ENVIRONMENTAL SCIENCES↗

The Portable Ice Nucleation Experiment (PINE): a new online instrument for laboratory studies and automated long-term field observations of ice-nucleating particles

Atmospheric ice-nucleating particles (INPs) play an important role in determining the phase of clouds, which affects their albedo and lifetime. A lack of data on the spatial and temporal variation of INPs around the globe limits our predictive capacity and understanding of clouds containing ice. Automated instrumentation that can robustly measure INP concentrations across the full range of tropospheric temperatures is needed in order to address this knowledge gap. In this study, we demonstrate the functionality and capacity of the new Portable Ice Nucleation Experiment (PINE) to study ice nucleation processes and to measure INP concentrations under conditions pertinent for mixed-phase clouds, with temperatures from about -10 to about -40°C. PINE is a cloud expansion chamber which avoids frost formation on the cold walls and thereby omits frost fragmentation and related background ice signals during the operation. The development, working principle and treatment of data for the PINE instrument is discussed in detail. We present laboratory-based tests where PINE measurements were compared with those from the established AIDA (Aerosol Interaction and Dynamics in the Atmosphere) cloud chamber. Within experimental uncertainties, PINE agreed with AIDA for homogeneous freezing of pure water droplets and the immersion freezing activity of mineral aerosols. Results from a first field campaign conducted at the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) observatory in Oklahoma, USA, from 1 October to 14 November 2019 with the latest PINE design (a commercially available PINE chamber) are also shown, demonstrating PINE's ability to make automated field measurements of INP concentrations at a time resolution of about 8 min with continuous temperature scans for INP measurements between -10 and -30°C. During this field campaign, PINE was continuously operated for 45 d in a fully automated and semi-autonomous way, demonstrating the capability of this new instrument to also be used for longer-term field measurements and INP monitoring activities in observatories.

54 ENVIRONMENTAL SCIENCES↗

Image-Guided Cryoablation of the Spine in a Swine Model: Clinical, Radiological, and Pathological Findings with Light and Electron Microscopy

PurposeThis study was designed to present the feasibility of an in vivo image-guided percutaneous cryoablation of the porcine vertebral body.MethodsThe institutional animal care committee approved this study. Cone-beam computed tomography (CBCT)-guided vertebral cryoablations (n = 22) were performed in eight pigs with short, 2-min, single or double-freezing protocols. Protective measures to nerves included dioxide carbon (CO{sub 2}) epidural injections and spinal canal temperature monitoring. Clinical, radiological, and pathological data with light (n = 20) or transmission electron (n = 2) microscopic analyses were evaluated after 6 days of clinical follow-up and euthanasia.ResultsCBCT/fluoroscopic-guided transpedicular vertebral body cryoprobe positioning and CO{sub 2} epidural injection were successful in all procedures. No major complications were observed in seven animals (87.5 %, n = 8). A minor complication was observed in one pig (12.5 %, n = 1). Logistic regression model analysis showed the cryoprobe-spinal canal (Cp-Sc) distance as the most efficient parameter to categorize spinal canal temperatures lower than 19 °C (p < 0.004), with a significant Pearson’s correlation test (p < 0.041) between the Cp-Sc distance and the lowest spinal canal temperatures. Ablation zones encompassed pedicles and the posterior wall of the vertebral bodies with an inflammatory rim, although no inflammatory infiltrate was depicted in the surrounding neural structures at light microscopy. Ultrastructural analyses evidenced myelin sheath disruption in some large nerve fibers, although neurological deficits were not observed.ConclusionsCBCT-guided vertebral cryoablation of the porcine spine is feasible under a combination of a short freezing protocol and protective measures to the surrounding nerves. Ultrastructural analyses may be helpful assess the early modifications of the nerve fibers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single-Centre Experience with Percutaneous Cryoablation of Breast Cancer in 23 Consecutive Non-surgical Patients

AimTo present our single-centre prospective experience on the use of cryoablation (CA) applied to treat primary breast cancer (BC) in a cohort of patients unsuitable for surgical treatment.Materials and MethodsTwenty-three consecutive post-menopausal female patients (median age 85 years; range 56–96) underwent percutaneous CA of unifocal, biopsy-proven BC, under ultrasound/computed tomography (US/CT) guidance. Clinical and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) follow-ups were systematically scheduled at 3, 12, 18 and 24 months. Local tumour control was assessed by comparing baseline and follow-up DCE-MRI.ResultsTwenty-three BC (median size 14 mm) were treated under local anaesthesia (78.3 %) or local anaesthesia and conscious sedation (21.7 %). Median number of cryo-probes applied per session was 2.0. A “dual-freezing” protocol was applied for the first ten patients and a more aggressive “triple-freezing” protocol for the remaining 13. Median follow-up was 14.6 months. Five patients recurred during follow-up and two were successfully re-treated with CA. Five patients presented immediate CA-related complications: four hematomas evolved uneventfully at 3-month follow-up and one skin burn resulted in skin inflammation and skin retraction at 3 and 12 months, respectively.ConclusionsPercutaneous CA is safe and well tolerated for non-resected elderly BC patients. Procedures can be proposed under local anaesthesia only. Given the insulation properties of the breast gland, aggressive CA protocols are required. Prospective studies are needed to better understand the potential role of CA in the local treatment of early BC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ablation Volume Measurement After Percutaneous Cryoablation Using a Two-cryo-probe Technique for Small Hepatocellular Carcinomas

Purpose: To calculate the ablation volume of percutaneous cryoablation (PCA) with a two-cryo-probe technique for small hepatocellular carcinomas (HCCs) and to assess risk factors for local tumor recurrence (LTR). Materials and Methods: Between January 2013 and June 2017, 96 patients (mean age, 60.7 years; range, 37–83 years) with 106 small HCCs were retrospectively analyzed. The ablation volume, technical success, LTR rates, and complications were evaluated. Ablation volume was measured after the first freezing and immediately after completing PCA twice via computed tomography imaging. Prognostic factors associated with LTR were analyzed. Results: Technical success was achieved in all patients. The mean final ablation volume was 19.1 ± 4.8 cm{sup 3}, which was significantly higher than the first freezing ablation volume (14.7 ± 4.3 cm{sup 3}, p < 0.001). During the median follow-up period of 16.7 months (range, 5–52 months), LTR-free survival rates based on Kaplan–Meier analyses at 6 months, 1 year, and 2 years were 87.7%, 84.0%, and 80.2%, respectively. Only one major complication of post-procedural arterial bleeding occurred. A final ablation volume/tumor volume < 10 was a significant risk factor for LTR (p = 0.044). Conclusions: A ratio of final ablation volume to tumor volume < 10 was a significant prognostic factor for LTR. Therefore, the measurement and prediction of the final ablation volume are important to reduce LTR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Storage Conditions on the Integrity of Human Umbilical Cord Mesenchymal Stromal Cell-Derived Microvesicles

We studied the effect of storage conditions on the safety of microvesicles produced by human multipotent umbilical cord mesenchymal stromal cells into the conditioned medium. It was found that microvesicles can be stored without serious degradation for up to 1 week at 4°С, but were almost completely destroyed during freezing and thawing cycles irrespective of the storage temperatures (-20°С, -70°С, or -196°С). Similar results were obtained for lyophilized medium conditioned by human multipotent umbilical cord mesenchymal stromal cells. Addition of a cryoprotectant (5-10% DMSO) followed by freezing and/or lyophilization preserved microvesicles at a nearly initial level. These findings indicate that during storage, microvesicles, being membrane structures, behave similar to living cells and require appropriate conditions for prolonged storage.

60 APPLIED LIFE SCIENCES↗