Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLUID MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Liquid Hydrogen Tank Chill and No-Vent Fill Prediction Using Computational Fluid Dynamics

Cryogenic tank chill and fill is an important cryogenic fluid management (CFM) technology that supports and enables many of NASA’s long-duration space missions. For no-vent fill, the receiver tank pressure remains below the supply tank pressure during the entire duration of the fill so that the tank does not require venting. This is especially advantageous for tank fill operations in low gravity where the position of the liquid is not always known and venting the tank may cause loss of propellant by venting liquid. In lieu of expensive tests conducted on-orbit, accurate computational models capable of predicting receiver tank pressure during cryogenic propellant tank fill may be used to reduce system and propellant mass as well as mission risk. However, these numerical models must be validated or anchored to test data. This study presents a computational fluid dynamics (CFD) model with conjugate heat transfer that is used to predict a liquid hydrogen tank chill and no-vent fill ground test conducted at Lewis Research Center (now Glenn Research Center) in 1991. The specific test case chosen for model validation implemented an upward-facing jet near the bottom of a cylindrical 34 liter tank. CFD predictions are compared to experimental measurements of tank pressure, fill level, fluid temperatures, and wall temperatures. The CFD results show reasonable agreement to the test data but overpredict the pressure collapse near the end of the fill despite the liquid jet penetrating the liquid-vapor interface. Several sensitivity studies are considered due to notable uncertainties in the experiment.

Computational Fluid Dynamics↗

Systems, methods and tools for subterranean electrochemical characterization and enthalpy measurement in geothermal reservoirs

The present disclosure is directed to systems, methods and tools that measure ionic concentrations and downhole enthalpy of a flowing geothermal fluid in real-time at high-temperature and pressure. The systems, methods and tools include measuring the concentration of selected naturally occurring ions found in the liquid phase of the geothermal fluid throughout the wellbore using novel electrochemical sensor technologies. The change in liquid-phase ion concentration will be used to calculate the proportion of liquid to steam and allow for accurate enthalpy measurements. The techniques and technologies described here can be applied to any application of electrochemical sensing in extreme environments.

Cieslewski, Grzegorz↗

Effect of bolus fluid intake on energy expenditure values as determined by the doubly labeled water method

The doubly labeled water (DLW, 2H(2)18O) method is a highly accurate method for measuring energy expenditure (EE). A possible source of error is bolus fluid intake before body water sampling. If there is bolus fluid intake immediately before body water sampling, the saliva may reflect the ingested water disproportionately, because the ingested water may not have had time to mix fully with the body water pool. To ascertain the magnitude of this problem, EE was measured over a 5-day period by the DLW method. Six subjects were dosed with 2H2(18)O. After the reference salivas for the two-point determination were obtained, subjects drank water (700-1,000 ml), and serial saliva samples were collected for the next 3 h. Expressing the postbolus saliva enrichments as a percentage of the prebolus value, we found 1) a minimum in the saliva isotopic enrichments were reached at approximately 30 min with the minimum for 2H (95.48 +/- 0.43%) being significantly lower than the minimum for 18O (97.55 +/- 0.44, P less than 0.05) and 2) EE values calculated using the postbolus isotopic enrichments are appreciably higher (19.9 +/- 7.5%) than the prebolus reference values. In conclusion, it is not advisable to collect saliva samples for DLW measurements within approximately 1 h of bolus fluid intake.

NASA Discipline Musculoskeletal↗

CD4(+)/CD8(+) T-lymphocyte Ratio: Effects of Rehydration before Exercise in Dehydrated Men

Effects of fluid ingestion on CD4+/CD8+ T-lymphocyte cell ratios were measured in four dehydrated men (ages 30-46 yr) before and after 70 min of supine submaximal (71 % VO(sub 2max) lower extremity cycle exercise. Just before exercise, Evans blue dye was injected for measurement of plasma volume. The subjects then drank one of six fluid formulations (12 ml/kg) in 3-4 min. All six mean post-hydration (pre-exercise) CD4+/CD8+ ratios (Becton-Dickinson Fluorescence Activated Cell Sorter and FACScan Consort-30 software program were below the normal range of 1.2-1.5; mean (+/- SE) and range were 0.77 +/- 0.12 and 0.39-1.15, respectively. The post-exercise ratios increased: mean = 1.36 =/- 0.15 (P less than 0.05) and range = 0.98-1.98. Regression of mean CD4+/CD8+ ratios on mean plasma osmolality resulted in pre- and post-exercise correlation coefficients of -0.76 (P less than 0.10) and -0.92 (P less than 0.01), respectively. The decreased pre-exercise ratios (after drinking) were probably not caused by the Evans blue dye but appeared to be associated more with the stress (osmotic) of dehydration. The increased post-exercise ratios to normal levels accompanied the rehydration and were not due to the varied electrolyte and osmotic concentrations of the ingested fluids or to the varied vascular volume shifts during exercise. Thus, the level of subject hydration and plasma osmotality may be factors involved in the mechanism of immune system modulation induced by exercise.

Greenleaf, John E.↗

The development of laser speckle velocimetry for the study of vortical flows

A new experimental technique commonly known as PIDV (particle image displacement velocity) was developed to measure an instantaneous two dimensional velocity fluid in a selected plane of the flow field. This technique was successfully applied to the study of several problems: (1) unsteady flows with large scale vortical structures; (2) the instantaneous two dimensional flow in the transition region of a rectangular air jet; and (3) the instantaneous flow over a circular bump in a transonic flow. In several other experiments PIDV is routinely used as a non-intrusive measurement technique to obtain instantaneous two dimensional velocity fields.

Krothapalli, A.↗

Development of buried wire gages for measurement of wall shear stress in Blastane experiments

Buried Wire Gages operated from a Constant Temperature Anemometer System are among the special types of instrumentation to be used in the Boundary Layer Apparatus for Subsonic and Transonic flow Affected by Noise Environment (BLASTANE). These Gages are of a new type and need to be adapted for specific applications. Methods were developed to fabricate Gage inserts and mount those in the BLASTANE Instrumentation Plugs. A large number of Gages were prepared and operated from a Constant Temperature Anemometer System to derive some of the calibration constants for application to fluid-flow wall shear-stress measurements. The final stage of the calibration was defined, but could not be accomplished because of non-availability of a suitable flow simulating apparatus. This report provides a description of the Buried Wire Gage technique, an explanation of the method evolved for making proper Gages and the calibration constants, namely Temperature Coefficient of Resistance and Conduction Loss Factor.

Murthy, S. V.↗

Tip-Clearance Vortex Characterized With Three-Dimensional Digital Particle Image Velocimetry

An optical measurement technique known as Three-Dimensional Digital Particle Image Velocimetry (3-D DPIV) was used to characterize the tip clearance flow in NASA Glenn Research Center's low-speed axial compressor. 3-D DPIV is a technique in which a stereoscopic imaging system consisting of two cross-correlation cameras is used to record particles entrained in a flow as a laser light sheet is pulsed at two instances in time. Although 3-D DPIV has been used elsewhere, this is the first time it has been used to measure compressor tip clearance flows. In-house modifications of the DPIV system include the use of effective seeding technology and a novel system to perform a priori calibrations at all five measurement planes, greatly reducing facility run time. Computational fluid dynamics predictions, which are used to guide design changes toward improving the efficiency and operating range of turbomachinery, can be verified and improved by comparison with 3-D DPIV measurements of the actual tip clearance flow. This measurement campaign dealt with the characterization of the tip clearance vortex in the first stage of a four-stage axial compressor. The tip clearance vortex is formed in compressors operating with a clearance gap between the moving rotor blade tips and the stationary casing when a leakage flow, forced from the pressure side of the blade over the blade tip, forms a vortical structure on the suction side of the blade. 3-D DPIV is ideally suited to measure the clearance vortex for two reasons: (1) this technique captures the entire blade passage flow at one instant in time, so that wandering of the vortex during the measurement does not smear out velocity gradients in the flow field, and (2) the spanwise component of velocity changes sign across the vortex core, providing a more accurate measurement of the vortex location than was available with previous two-dimensional measurement approaches. These two attributes of the data will enable computational fluid dynamics researchers to validate their predictions to a level of accuracy not previously attainable. In an effort to understand the effects of this flow phenomenon on the operation of the low speed axial compressor, data were acquired at two mass flow coefficients: 0.395 (design operating point) and 0.35 (operating point just above stall). In order to identify the spatial extent, location, and magnitude of the tip clearance vortex for each mass flow condition, data were acquired at five equally spaced spanwise locations, from 90- to 100-percent span. The data presented shows a cross section of the tip clearance vortex at 94-percent span and a mass flow coefficient of 0.395, where the color contours represent the radial velocity component. The blue (flow towards the hub) and red (flow towards the casing) regions illustrate the extent of the tip clearance vortex. The interface between the blue and red regions delineates the location of the vortex core.

John, W. Trevor↗

Local heat transfer measurement in a volumetrically heated TPMS lattice using distributed optical fiber thermal sensing

As additive manufacturing continues to reduce design constraints on heat exchange geometries, methods for high-fidelity local heat transfer measurements in nonconventional channel geometries are critical to their continued development. This study presents a novel method for measuring local heat transfer performance in volumetrically heated lattices using a distributed optical fiber temperature sensor. A diamond-type triply periodic minimal surface (TPMS) lattice, 3D-printed from a conductive polymer, was Joule heated while it was convectively cooled with air. Temperature measurements were taken at the solid–fluid interface across 14 internal locations using a single optical fiber over the Reynolds number range 800–2750. The TPMS lattice achieved up to 312% higher heat transfer coefficients compared to developing flow in a straight tube. A Nusselt number correlation was developed for the diamond TPMS, which showed good agreement with data collected for comparable geometries available in literature. In conclusion, this study presents a robust and new method for experimental measurement of the heat transfer coefficient in complex geometries and helps to understand and quantify the exceptional performance of TPMS heat transfer geometries.

TPMS↗

Effect of chronic intracerebroventricular angiotensin II infusion on vasopressin release in rats

The effects of the chronic infusion of angiotensin II into the lateral cerebral ventricle on the release of arginine vasopressin in rats are investigated. Rats were subjected to a continuous infusion of angiotensin at a rate of 1 microgram/h for five days, during which they were offered water, isotonic saline or hypertonic saline ad libitum or 40 ml water/day, and fluid intake, changes in body weight, plasma sodium ion concentrations and plasma and pituitary arginine vasopressin levels were measured. Angiotensin II is found to increase the fluid intake of rats given isotonic saline and decrease plasma sodium ion levels with no changes in plasma or pituitary arginine vasopressin in those given water or isotonic saline. However, in rats given hypertonic saline, plasma sodium concentrations remained at control levels while plasma vasopressin increased, and in water-restricted rats the effects of angiotensin II were intermediate. Results thus demonstrate that angiotensin II-stimulated arginine vasopressin release is reduced under conditions in which plasma sodium ion concentration becomes dilute, compatible with a central role of angiotensin in the regulation of salt and water balance.

Sterling, G. H.↗

Maximizing REE Recovery in Geothermal Systems

Rare Earth element (REE) concentrations were measure in several on-land geothermal systems, many of which boil due to pressure drop during fluid upflow in geothermal production wells. REE were also measured in several seafloor hydrothermal systems sampled at pressures above the boiling point for comparison to boiled systems. Boiling during production lowers REE concentration in fluids sampled at the well head due to changes in fluid pH and Temperature that occur during boiling that affect the solubility of REE mineral phases. Geochemical calculations using the best available thermodynamic data were preformed to extend the understanding of REE behavior beyond the systems sampled for this study. Our data and modeling show that REE concentration in geothermal fluids is controlled by solubility limits, not by concentration in the source rocks. With the exception of La and Ce, the concentration of most of the REE in geothermal fluids are less than one part per trillion. There are no reasonable scenarios under which co-production of REE from geothermal fluids used to produce energy will contribute to the economic viability of the resource.

15 GEOTHERMAL ENERGY↗

Predicting uniaxial compressive strength from empirical relationships between ultrasonic p-wave velocities, porosity, and core measurements in a potential geothermal reservoir, Snake River Plain, Idaho

Empirical, core-based, predictive correlations for the calculation of uniaxial compressive strength (UCS) were developed from compressive sonic velocity measurements (55 whole core samples) and porosity, density, and unconfined compressive tests (110 whole core samples). The samples were collected at 55 different depths in a 550 m (1800 ft) interval of core from the MH-2 borehole located in southern Idaho, USA. The western Snake River Plain is a known region of high heat flow and the borehole was drilled into a potential geothermal reservoir characterized by artesian flow of high-temperature (~140°C) fluids from fractured basalt. UCS was measured in unconfined compressive tests, density and porosity were measured using a He-pycnometer, and p-wave velocities were measured in a pressure vessel under variable confining pressures. We use correlations between density and p-wave velocity (R 2 = 0.91), UCS and porosity (R 2 = 0.78), and UCS and p-wave velocity (R 2 = 0.79) in a method to calculate calibrated UCS from wireline logs. Here, the impact of this predictive correlation is that UCS can be calculated from as little as a bulk density log when sonic logs and core are not available, greatly increasing the number of wells in which we can obtain a local UCS estimate.

15 GEOTHERMAL ENERGY↗

Design of a Subscale Propellant Slag Evaluation Motor Using Two-Phase Fluid Dynamic Analysis

Small pressure perturbations in the Space Shuttle Reusable Solid Rocket Motor (RSRM) are caused by the periodic expulsion of molten aluminum oxide slag from a pool that collects in the aft end of the motor around the submerged nozzle nose during the last half of motor operation. It is suspected that some motors produce more slag than others due to differences in aluminum oxide agglomerate particle sizes that may relate to subtle differences in propellant ingredient characteristics such as particle size distributions or processing variations. A subscale motor experiment was designed to determine the effect of propellant ingredient characteristics on the propensity for slag production. An existing 5 inch ballistic test motor was selected as the basic test vehicle. The standard converging/diverging nozzle was replaced with a submerged nose nozzle design to provide a positive trap for the slag that would increase the measured slag weights. Two-phase fluid dynamic analyses were performed to develop a nozzle nose design that maintained similitude in major flow field features with the full scale RSRM. The 5 inch motor was spun about its longitudinal axis to further enhance slag collection and retention. Two-phase flow analysis was used to select an appropriate spin rate along with other considerations, such as avoiding bum rate increases due to radial acceleration effects. Aluminum oxide particle distributions used in the flow analyses were measured in a quench bomb for RSRM type propellants with minor variations in ingredient characteristics. Detailed predictions for slag accumulation weights during motor bum compared favorably with slag weight data taken from defined zones in the subscale motor and nozzle. The use of two-phase flow analysis proved successful in gauging the viability of the experimental program during the planning phase and in guiding the design of the critical submerged nose nozzle.

Whitesides, R. Harold↗

Characterization of unsaturated hydraulic conductivity in fractured media using the multistep outflow method - 15461

The multistep outflow method is routinely used to characterize the unsaturated hydraulic conductivity of soils. The technique involves placing a soil sample in a pressure plate apparatus, subjecting the sample to multiple gas pressures in discrete steps through time, and measuring the transient volume of pore fluid extracted. Unsaturated hydraulic property values are estimated through inverse modeling of the experimental conditions. In this study the multistep outflow concept was applied to micro-cracked cementitious materials to assess the efficacy of the technique for these materials. The cementitious materials tested were salt-waste simulant grout samples artificially damaged through oven-drying. Compared to typical soils, fractured media exhibit higher saturated conductivity and lower air-entry pressure, and the volume of fluid extractable from fractures is much lower than soil porosity. To accommodate these material differences the standard test apparatus was modified to incorporate a higher conductivity ceramic pressure plate, a high-precision digital balance for logging outflow mass, a low volume (diameter) effluent line, multiple in-line high-precision gas regulators, and a high-precision low-range pressure gauge. Testing to date indicates that the modified apparatus can provide a viable means to measure the unsaturated hydraulic properties of micro-fractured cementitious materials. However the accuracy/uniqueness of inverse modeling is limited by the inherent characteristics of fractured media: high saturated conductivity, low air-entry pressure, and strong non-linearities. Hydraulic property results in the form of van Genuchten / Mualem curves are presented for three fractured grout specimens. DOE Performance Assessments often involve cementitious barriers and/or waste forms that are predicted or assumed to degrade over time due to various mechanisms such as carbonation-influenced reinforcing steel corrosion, external sulfate attack, differential settlement, and seismic activity. Physical degradation typically takes the form of small-scale cracking / fracturing, and the affected materials reside in unsaturated hydrogeologic zones. In these cases, unsaturated hydraulic properties are needed for fractured cementitious materials to simulate moisture movement and contaminant transport within and around the facility. The outflow extraction method, as implemented in the present study, provides a suitable method for estimating these material properties. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The kinetic origin of the fluid helicity—A symmetry in the kinetic phase space

Helicity, a topological degree that measures the winding and linking of vortex lines, is preserved by ideal (barotropic) fluid dynamics. In the context of the Hamiltonian description, the helicity is a Casimir invariant characterizing a foliation of the associated Poisson manifold. Casimir invariants are special invariants that depend on the Poisson bracket, not on the particular choice of the Hamiltonian. The total mass (or particle number) is another Casimir invariant, whose invariance guarantees the mass (particle) conservation (independent of any specific choice of the Hamiltonian). In a kinetic description (e.g., that of the Vlasov equation), the helicity is no longer an invariant (although the total mass remains a Casimir of the Vlasov’s Poisson algebra). The implication is that some “kinetic effect” can violate the constancy of the helicity. To elucidate how the helicity constraint emerges or submerges, we examine the fluid reduction of the Vlasov system; the fluid (macroscopic) system is a “sub-algebra” of the kinetic (microscopic) Vlasov system. In the Vlasov system, the helicity can be conserved if a special helicity symmetry condition holds. To put it another way, breaking helicity symmetry induces a change in the helicity. We delineate the geometrical meaning of helicity symmetry and show that for a special class of flows (the so-called epi-two-dimensional flows), the helicity symmetry is written as ∂γ = 0 for a coordinate γ of the configuration space.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Kinetic electrocaloric effect and giant net cooling of lead-free ferroelectric refrigerants

The electrocaloric effect of BaTiO{sub 3} multilayer thick film structure was investigated by direct measurement using differential scanning calorimeter. The samples show a giant electrocaloric effect of 0.89 J/g under E=176 kV/cm, which also depends on the varying rate of applied field, following a general power-law relation. Based on the large net-cooling (0.37 J/g) resulting from the difference in the varying rates of rising and falling fields, the kinetic electrocaloric effect provides a solution for the design of refrigeration cycle in ferroelectric microrefrigerator.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

CVB: the Constrained Vapor Bubble Capillary Experiment on the International Space Station MARANGONI FLOW REGION

The Constrained Vapor Bubble (CVB) is a wickless, grooved heat pipe and we report on a full- scale fluids experiment flown on the International Space Station (ISS). The CVB system consists of a relatively simple setup a quartz cuvette with sharp corners partially filled with either pentane or an ideal mixture of pentane and isohexane as the working fluids. Along with temperature and pressure measurements, the two-dimensional thickness profile of the menisci formed at the corners of the quartz cuvette was determined using the Light Microscopy Module (LMM). Even with the large, millimeter dimensions of the CVB, interfacial forces dominate in these exceedingly small Bond Number systems. The experiments were carried out at various power inputs. Although conceptually simple, the transport processes were found to be very complex with many different regions. At the heated end of the CVB, due to a high temperature gradient, we observed Marangoni flow at some power inputs. This region from the heated end to the central drop region is defined as a Marangoni dominated region. We present a simple analysis based on interfacial phenomena using only measurements from the ISS experiments that lead to a predictive equation for the thickness of the film near the heated end of the CVB. The average pressure gradient for flow in the film is assumed due to the measured capillary pressure at the two ends of the liquid film and that the pressure stress gradient due to cohesion self adjusts to a constant value over a distance L. The boundary conditions are the no slip condition at the wall interface and an interfacial shear stress at the liquid- vapor interface due to the Marangoni stress, which is due to the high temperature gradient. Although the heated end is extremely complex, since it includes three- dimensional variations in radiation, conduction, evaporation, condensation, fluid flow and interfacial forces, we find that using the above simplifying assumptions, a simple successful model can be developed.

heat pipes↗

Nanoscale rheology at solid-complex fluid interfaces

Here we present an approach to measure dynamic membrane properties of phospholipid membranes close to an interface. As an example we show results of the membrane dynamics of a phospholipid membrane multilayer-stack on a solid substrate (silicon). On this sample we were able to measure local interaction and friction parameters using Grazing Incidence Neutron Spin Echo Spectroscopy (GINSES), where an evanescent neutron wave probes the fluctuations close to a rigid interface. With this method it is possible to access length scales in the nano to micrometer region as well as energies in the μeV range. Using a new neutron resonator structure we achieved the required intensity gain for this experiment. During our investigations we found an excitation mode of the phospholipid membrane that has not been reported previously and only became visible using the new methodology. We speculate that the energy transported by that undulation can also serve to distribute energy over a larger area of the membrane, stabilizing it. This new methodology has the capability to probe the viscoelastic effects of biological membranes, becoming a new tool for tribology on the nanoscale and has allowed the observation of the hitherto invisible property of phospholipid membranes using neutrons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗