Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLAT PLATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Evaluation of numerical schemes for the analysis of sound generation by blade-gust interaction

In this investigation three different numerical algorithms have been utilized to compute the flow about a flat plate in the presence of a transverse gust described by a sinusoidal disturbance. The three schemes include the MacCormack explicit finite difference scheme which is second order accurate in both time and space, the Gottlieb and Turkel modification of MacCormack's scheme which is fourth order accurate in space and second order accurate in time, (referred to as the 2-4 scheme), and a two step scheme developed by Bayliss et al. which has second order temporal accuracy and sixth order spatial accuracy (a 2-6 scheme). The flow field results are obtained with these schemes by using the same code with the only difference being the implementation of the respective solution algorithms. The problem is set up so that the sinusoidal disturbance is imposed at the surface of the flat plate as a surface boundary condition. Thus the problem is treated as scattering problem. The computed results include the time average of the acoustic pressure squared along grid lines five points away from the boundaries; distribution throughout the computational domain is monitored at various times. The numerical results are compared with an exact solution obtained by Atassi, Dusey, and Davis.

Scott, J. N.↗

Bending with large deflection of a clamped rectangular plate with length-width ratio of 1.5 under normal pressure

The Von Karman equations for a thin flat plate with large deflections are solved for the special case of a plate with clamped edges having a ratio of length to width of 1.5 and loaded by uniform normal pressure. Center deflections, membrane stresses, and extreme-fiber bending stresses are given as a function of pressure for center deflections up to twice the thickness of the plate. For small deflections the results coincide with those obtained by Hencky from the linear theory. The maximum stresses and center deflection at high pressures differ less than 3 percent from those derived by Bostnov for an infinitely long plate with clamped edges. This agreement suggests that clamped plates with a length-to-width ratio greater than 1.5 may be reared as infinitely long plates for purposes of design.

PLATES-BENDING CIRCULAR↗

Unified aerodynamic-acoustic theory for a thin rectangular wing encountering a gust

A linear aerodynamic-acoustic theory is developed for the prediction of the surface pressure distribution and three-dimensional acoustic far-field for a flat plate rectangular wing encountering a stationary short-wavelength oblique gust. It is suggested that for an infinite-span wing, leading- and trailing-edge responses to a short-wavelength gust are essentially independent. This idea is used to solve for the two-dimensional pressure field due to the passage of an infinite-span wing through an oblique gust. By allowing the field point to come down to the wing's surface, one finds an expression for the surface pressure distribution which agrees with that given in the two-dimensional aerodynamic theories of Amiet and Adamczyk. Spanwise Fourier superposition of two-dimensional solutions to the infinite-span wing problem is used to approximate the three-dimensional acoustic field due to the interaction of a stationary oblique gust with a flat-plate rectangular wing traveling at a subsonic speed.

Martinez, R.↗

Exploratory investigation of sound pressure level in the wake of an oscillating airfoil in the vicinity of stall

Wind tunnel tests were performed on two oscillating two-dimensional lifting surfaces. The first of these models had an NACA 0012 airfoil section while the second simulated the classical flat plate. Both of these models had a mean angle of attack of 12 degrees while being oscillated in pitch about their midchord with a double amplitude of 6 degrees. Wake surveys of sound pressure level were made over a frequency range from 16 to 32 Hz and at various free stream velocities up to 100 ft/sec. The sound pressure level spectrum indicated significant peaks in sound intensity at the oscillation frequency and its first harmonic near the wake of both models. From a comparison of these data with that of a sound level meter, it is concluded that most of the sound intensity is contained within these peaks and no appreciable peaks occur at higher harmonics. It is concluded that within the wake the sound intensity is largely pseudosound while at one chord length outside the wake, it is largely true vortex sound. For both the airfoil and flat plate the peaks appear to be more strongly dependent upon the airspeed than on the oscillation frequency. Therefore reduced frequency does not appear to be a significant parameter in the generation of wake sound intensity.

Gray, R. B.↗

Advanced photovoltaic power systems using tandem GaAs/GaSb concentrator modules

In 1989, Boeing announced the fabrication of a tandem gallium concentrator solar cell with an energy conversion efficiency of 30 percent. This research breakthrough has now led to panels which are significantly smaller, lighter, more radiation resistant, and potentially less expensive than the traditional silicon flat plate electric power supply. The new Boeing tandem concentrator (BTC) module uses an array of lightweight silicone Fresnel lenses mounted on the front side of a light weight aluminum honeycomb structure to focus sunlight onto small area solar cells mounted on a thin back plane. This module design is shown schematically. The tandem solar cell in this new module consists of a gallium arsenide light sensitive cell with a 24 percent energy conversion efficiency stacked on top of a gallium antimonide infrared sensitive cell with a conversion efficiency of 6 percent. This gives a total efficiency 30 percent for the cell-stack. The lens optical efficiency is typically 85 percent. Discounting for efficiency losses associated with lens packing, cell wiring, and cell operating temperature still allows for a module efficiency of 22 percent which leads to a module power density of 300 Watts/sq. m. This performance provides more than twice the power density available from a single crystal silicon flat plate module and at least four times the power density available from amorphous silicon modules. The fact that the lenses are only 0.010 ft. thick and the aluminum foil back plane is only 0.003 ft. thick leads to a very lightweight module. Although the cells are an easy to handle thickness of 0.020 ft., the fact that they are small, occupying one-twenty-fifth of the module area, means that they add little to the module weight. After summing all the module weights and given the high module power, we find that we are able to fabricate BTC modules with specific power of 100 watts/kg.

Fraas, L. M.↗

Experimental studies of transpiration cooling with shock interaction in hypersonic flow, part B

This report describes the result of experimental studies conducted to examine the effects of the impingement of an oblique shock on the flowfield and surface characteristics of a transpiration-cooled wall in turbulent hypersonic flow. The principal objective of this work was to determine whether the interaction between the oblique shock and the low-momentum region of the transpiration-cooled boundary layer created a highly distorted flowfield and resulted in a significant reduction in the cooling effectiveness of the transpiration-cooled surface. As a part of this program, we also sought to determine the effectiveness of transpiration cooling with nitrogen and helium injectants for a wide range of blowing rates under constant-pressure conditions in the absence of shock interaction. This experimental program was conducted in the Calspan 48-Inch Shock Tunnel at nominal Mach numbers of 6 and 8, for a Reynolds number of 7.5 x 10(exp 6). For these test conditions, we obtained fully turbulent boundary layers upstream of the interaction regions over the transpiration-cooled segment of the flat plate. The experimental program was conducted in two phases. In the first phase, we examined the effects of mass-addition level and coolant properties on the cooling effectiveness of transpiration-cooled surfaces in the absence of shock interaction. In the second phase of the program, we examined the effects of oblique shock impingement on the flowfield and surface characteristics of a transpiration-cooled surface. The studies were conducted for a range of shock strengths with nitrogen and helium coolants to examine how the distribution of heat transfer and pressure and the characteristics of the flowfield in the interaction region varied with shock strength and the level of mass addition from the transpiration-cooled section of the model. The effects of the distribution of the blowing rate along the interaction regions were also examined for a range of blowing rates through the transpiration-cooled panels. The regions of shockwave/boundary layer interaction examined in these studies were induced by oblique shocks generated with a sharp, flat plate, inclined to the freestream at angles of 5 degrees, 7.5 degrees, and 10 degrees. It was found that, in the absence of an incident shock, transpiration cooling was a very effective method for reducing both the heat transfer and the skin friction loads on the surface. The helium coolant was found to be significantly more effective than nitrogen, because of its low molecular weight and high specific heat. The studies of shock-wave/transpiration-cooled surface interaction demonstrated that the interaction region between the incident shock and the low-momentum transpiration-cooled boundary layer did not result in a significant increase in the size of attached or separated interaction regions, and did not result in significant flowfield distortions above the interaction region. The increase in heating downstream of the shock-impingement point could easily be reduced to the values without shock impingement by a relatively small increase in the transpiration cooling in this region. Surprisingly, this increase in cooling rate did not result in a significant increase in size of the region ahead of the incident shock or create a significantly enlarged interaction region with a resultant increase in the distortion level in the inviscid flow. Thus, transpiration cooling appears to be a very effective technique to cool the internal surfaces of scramjet engines, where shocks in the engine would induce large local increases in wall heating and create viscous/inviscid interactions that could significantly disturb the smooth flow through the combustor. However, if hydrogen is used as the coolant, burning upstream of shock impingement might result in localized hot spots. Clearly, further research is needed in this area.

Holden, Michael S.↗

A New Model to Determine Installed System Cost and LCOE for ARPA-E's MOSAIC Micro-Concentrator PV Program: Preprint

The US Department of Energy's Advanced Research Projects Agency-Energy (ARPA-E) started a three-year program in December 2015 called Microscale Optimized Solar-cell Arrays with Integrated Concentration (MOSAIC). It consists of 11 teams from across the United States. Its goal is to have project teams leverage expertise from conventional flat-plate photovoltaic (PV) system configuration and concentrated photovoltaic (CPV) module technology to produce a new class of modules for residential, commercial, and utility-scale markets. The intent is to increase performance and facilitate cost-effective deployment of solar power systems across a wide range of geographical locations in part by concentrating both direct and diffuse components of the sun's irradiance. This paper describes a collaboration of ARPA-E and the National Renewable Energy Laboratory (NREL) to develop a bottom-up system cost model for MOSAIC research teams. The model includes an estimate of regional, all-in, CPV installed cost, and levelized cost of energy (LCOE) by using customized inputs parameters, such as module efficiency, cost, and physical dimensions. This techno-economic cost model can help researchers analyze tradeoffs among different design parameters and then prioritize their distinct research opportunities. Moreover, it establishes a standardized cost benchmarking for MOSAIC micro-CPV systems and a normalized comparison against traditional CPV and today's highly competitive flat-plate PV systems. The model is a valuable design tool within the program, helping validate the various technical approaches and compare future deployed system competitiveness versus incumbent technologies in the PV industry.

14 SOLAR ENERGY↗

The use of transition region characteristics to improve the numerical simulation of heat transfer in bypass transitional flows

A method is presented for improving the numerical prediction of bypass transition heat transfer on a flat plate in a high-disturbance environment with zero or favorable pressure gradient. The method utilizes low Reynolds number k-epsilon turbulence models in combination with the characteristic parameters of the transition region. The parameters representing the characteristics of the transition region used are the intermittency, transition length and turbulent spot properties. An analysis is made of the transition length in terms of turbulent spot variables. The nondimensional spot formation rate, required for the prediction of the transition length, is shown by the analysis to be a function of the spot spreading angle, the dimensionless spot velocity ratio and the dimensionless spot area ratio. The intermittency form of the k-epsilon equations were derived from conditionally averaged equations which have been shown to be an improvement over global-time-averaged equations for the numerical calculation of the transition region. The numerical predictions are in general good agreement with the experimental data and indicate the potential use of the method in accelerating flows. Turbulence models of the k-epsilon type are known to underpredict the transition length. The present work demonstrates how incorporating transition region characteristics improves the ability of two-equation turbulence models to simulate bypass transition for flat plates with potential application to turbine vanes and blades.

Simon, Frederick F.↗

Hybrid Solar Thermal Energy System for District Heating Application

Solar district heating (SDH) systems can be good alternatives to conventional systems when they are optimized with hybrid configurations and thermal energy storage (TES). In this scope, a hybrid renewable thermal energy system (RTES) model has been built combining flat plate collector (FPC) solar system with parabolic trough collector (PTC) system via a heat exchanger and coupled with TES. To undertake the hybridization of the system, System Advisor Model (SAM) software was modified, which allowed control over configurations and more accurate modelling of heat transfer between the collectors. The model is first compared to an existing hybrid solar district heating systems (DHS) system in Taars, Denmark. The results showed a good correlation with an overestimation of only 6.4% compared to most recent heat output. Then the same system configuration was modeled in different geographic locations to investigate the impact of changes in direct normal irradiance (DNI) to the heat sink thermal output of the hybrid system. The results showed that the annual net thermal power output in California, USA can be three times more than the annual net thermal power output in Taars, Denmark. Finally, multiple hybrid configurations with varying solar field sizes were simulated based on the heat demand of two different university campuses DHS. The results showed that, retrofit applications of this hybrid DHS system coupled with TES could reduce the natural gas consumption of the existing systems between 25% and 41%. The use of hybrid RTES highlighted in this paper can be extended to many more opportunities.

district heating↗

Prediction of Transitional Flows in the Low Pressure Turbine

Current turbulence models tend to give too early and too short a length of flow transition to turbulence, and hence fail to predict flow separation induced by the adverse pressure gradients and streamline flow curvatures. Our discussion will focus on the development and validation of transition models. The baseline data for model comparisons are the T3 series, which include a range of free-stream turbulence intensity and cover zero-pressure gradient to aft-loaded turbine pressure gradient flows. The method will be based on the conditioned N-S equations and a transport equation for the intermittency factor. First, several of the most popular 2-equation models in predicting flow transition are examined: k-e [Launder-Sharina], k-w [Wilcox], Lien-Leschiziner and SST [Menter] models. All models fail to predict the onset and the length of transition, even for the simplest flat plate with zero-pressure gradient(T3A). Although the predicted onset position of transition can be varied by providing different inlet turbulent energy dissipation rates, the appropriate inlet conditions for turbulence quantities should be adjusted to match the decay of the free-stream turbulence. Arguably, one may adjust the low-Reynolds-number part of the model to predict transition. This approach has so far not been very successful. However, we have found that the low-Reynolds-number model of Launder and Sharma [1974], which is an improved version of Jones and Launder [1972] gave the best overall performance. The Launder and Sharma model was designed to capture flow re-laminarization (a reverse of flow transition), but tends to give rise to a too early and too fast transition in comparison with the physical transition. The three test cases were for flows with zero pressure gradient but with different free-stream turbulent intensities. The same can be said about the model when considering flows subject to pressure gradient(T3C1). To capture the effects of transition using existing turbulence models, one approach is to make use of the concept of the intermittency to predict the flow transition. It was originally based on the intermittency distribution of Narasimha [1957], and then gradually evolved into a transport equation for the intermittency factor. Gostelow and associates [1994,1995] have made some improvements to Narasimha's method in an attempt to account for both favorable and adverse pressure gradients. Their approach is based on a linear, explicit combination of laminar and turbulent solutions. This approach fails to predict the overshoot of the skin friction on a flat plate near the end of transition zone, even though the length of transition is well predicted. The major flaw of Gostelow's approach is that it assumes the non-turbulent part being the laminar solution and the turbulent part being the turbulent solution and they do not interact across the transitional region. The technique in condition averaging the flow equations in intermittent flows was first introduced by Libby [1975] and Dopazo [1977] and further refined by Dick and associates [1988, 1996]. This approach employs two sets of transport equations for the non-turbulent part and the other for the turbulent part. The advantage of this approach is that it allows the interaction of non-turbulent and turbulent velocities through the introduction of additional source terms in the continuity and momentum equations for the non-turbulent and turbulent velocities. However, the strong coupling of the two sets of equations has caused some numerical difficulties, which requires special attention. The prediction of the skin friction can be improved by this approach via the implicit coupling of non-turbulent and turbulent velocity flelds. Another improvement of the interrmittency model can be further made by allowing the intermittency to vary in the cross-stream direction. This is one step prior to testing any proposal for the transport equation for the intermittency factor. Instead of solving the transport equation for the intermittency factor, the distribution for the intermittency factor is prescribed by Klebanoff's empirical formula [1955]. The skin friction is very well predicted by this new modification, including the overshoot of the profile near the end of the transition zone. The outcome of this study is very encouraging since it indicates that the proper description of the intermittency distribution is the key to the success of the model prediction. This study will be used to guide us on the modelling of the intermittency transport equation.

Huang, George↗

Restraint Provided a Flat Rectangular Plate by a Sturdy Stiffener Along an Edge of the Plate

A sturdy stiffener is defined as a stiffener of such proportions that it does not suffer cross-sectional distortion when moments are applied to some part of the cross section. When such a stiffener is attached to one edge of a plate, it will resist rotation of that edge of the plate by means of its torsional properties. A formula is given for the restraint coefficient provided the plate by such a stiffener. This coefficient is required for the calculation of the critical compressive stress of the plate.

Lundquist, Eugene E↗

Restraint Provided a Flat Rectangular Plate by a Sturdy Stiffener Along an Edge of the Plate, Special Report

A sturdy stiffener is defined as a stiffener of such proportions that it does not suffer cross-sectional distortion when moments are applied to some part of the cross section. When such a stiffener is attached to one edge of a plate, it will resist rotation of that edge of the plate by means of its torsional properties. A formula is given for the restraint coefficient provided the plate by such a stiffener. This coefficient is required for the calculation of the critical compressive stress of the plate.

Lundquist, Eugene E.↗

Effects of Heave Plate Topology on Reaction Forces

Multi-body wave energy converters often rely on "heave plates" to generate the reaction forces required for energy harvesting. However, the influence of threedimensional heave plate topology on these reaction forces is relatively unexplored in the literature. Using laboratory experiments, we investigate the reaction forces generated by three distinct heave plate topologies: A flat hexagonal plate, an open hexagonal-conic, and an enclosed hexagonalconic (i.e., interior cavity flooded with water). Though the flat plate is the least massive of the topologies, it generates the greatest total reaction force for nearly all experimental cases due to higher fluid force. Our results also demonstrate that the flat plate generally experiences the greatest force variability between the three topologies, especially during relatively large oscillations (KC greater than 2). Globally, force variability increases with the Keulegan Carpenter (KC) number. These results highlight the importance of heave plate topology on multi-body point wave energy converter performance.

heave plate↗