Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FERMILAB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Measurement and manipulation of beta functions in the Fermilab Booster

In order to meet the needs of Fermilabs planned post-collider experimental program, the total proton throughput of the 8 GeV Booster accelerator must be nearly doubled within the next two years. A system of 48 ramped corrector magnets has recently been installed in the Booster to help improve efficiency and allow for higher beam intensity without exceeding safe radiation levels. We present the preliminary results of beta function measurements made using these corrector magnets. Our goal is to use the correctors to reduce irregularities in the beta function, and ultimately to introduce localized beta bumps to reduce beam loss or direct losses towards collimators.

43 PARTICLE ACCELERATORS↗

Diagnostic Systems in the Muon $g-2$ experiment at Fermilab

The muon anomalous magnetic moment, $a_\mu=\frac{g-2}{2}$, is a low-energy observable which can be both measured and computed to high precision, making it a sensitive test of the Standard Model and a probe for new physics. This anomaly was measured with a precision of $0.20$~parts per million (ppm) by the Fermilab's Muon g-2 (E989) experiment. The final goal of the E989 experiment is to reach a precision of $0.14$~ppm. The experiment is based on the measurement of the muon spin anomalous precession frequency, $\omega_a$, based on the arrival time distribution of high-energy decay positrons observed by 24 electromagnetic calorimeters, placed around the inner circumference of a $14$~m diameter storage ring, and on the precise knowledge of the storage ring magnetic field and of the beam time and space distribution. Achieving this level of precision requires strict control over systematics, which is ensured through several diagnostic devices. At the accelerator level, these devices monitor the quality of the injected beam (e.g., verifying that it has the correct momentum), while at the detector level, they track both the magnetic field and the gain of the calorimeters. In this work the devices and techniques used by the E989 experiment will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the anomalous precession frequency in the Muon $g-2$ experiment at Fermilab

The muon anomalous magnetic moment, $a_\mu=\frac{g-2}{2}$, is a low energy observable that can be both measured and computed with high precision, therefore it can provide an important test of the Standard Model and it is a sensitive probe for new physics. In particular, any discrepancy between the experimental value and the theoretical prediction can be due to Beyond Standard Model physics contribution. The E989 Muon $g-2$ Experiment at Fermilab aims to measure $a_\mu$ with a precision of 140 parts per billion, four time more precisely than the previous experiment at Brookhaven National Laboratory (BNL). E989 seeks to either resolve or confirm the observed discrepancy of $3.7\sigma$ between the Standard Model value and the experimental one. The $a_\mu$ measurement requires a precise determination of both the muon spin anomalous precession frequency and the average magnetic field seen by the muons as they circulate in a storage ring. The anomalous precession frequency measurement is b ased on the time distribution of high-energy decay positrons observed by 24 electromagnetic calorimeters placed around the inner circumference of the ring, while the magnetic field is constantly monitored by NMR probes. Last spring, E989 has published a new measurement of $a_\mu$ from the 2018 data-taking campaign, confirming the previous BNL value with comparable precision, bringing the discrepancy with the theoretical value to $4.2\sigma$. The candidate worked on the measurement of the anomalous precession frequency and on the estimate of the related systematic uncertainties of the 2018 data, giving an important contribution to the data analysis. The result presented in chapters 4 and 5 of this dissertation was included, among three other analyses, to determine the estimate of the anomalous magnetic moment by the Muon g-2 experiment. This work will present the anomalous precession frequency analysis technique and its result, the related systematics and finally the latest $a_\mu$ result.

Sorbara, Matteo↗

Searches for New Physics With Muon Conversion at Fermilab and Triboson Production at the LHC

We report on several efforts to search for physics beyond the standard model of particle physics at broad energy scales. The Mu2e experiment at Fermilab will search for charged lepton flavor violation via the muon to electron conversion process, which is suppressed in the Standard Model. Mu2e will be operated at a low energy, yet can probe New Physics at very high mass scales (O(1e3 - 1e4 ) TeV). At high energies, the CMS experiment at the CERN LHC continues to deliver an impressive suite of Standard Model measurements and limits on a variety of New Physics signatures. Mu2e is under construction and slated to collect its first physics data in the coming years. This thesis describes work done during the construction phase of Mu2e and focuses on two critical areas: magnetic field modeling and statistical analysis. We describe a novel method for field modeling which we validate using a simulated dataset representing the expected magnetic field in the Detector Solenoid. This method blends a standard least-squares fitting technique that utilizes physically motivated analytical model functions with a novel physics informed network that is constructed to obey Maxwell’s equations. We show the technique can model the field with an accuracy of 10−7 despite the presence of injected noise in the pseudo-measurements at the 10−5 level. We then present preliminary results of the calibration of 3D Hall probes at the sub-10−4 level. These probes will be used to directly measure the Mu2e Detector Solenoid magnetic field on a sparse grid; these measurements serve as the input to the field model fitting. Finally, we describe the first implementation of both an unbinned shape analysis and a Bayesian interpretation applied to Mu2e pseudo-data. Up to 20% tighter limits can be set by the shape analysis compared to a standard cut & count analysis. The AlCap experiment collected data at PSI in 2015 to measure several important quantities related to nuclear muon capture on an aluminum target, which is a significant background process for Mu2e. The neutron emission from muon capture can introduce background hits in the Mu2e detectors and can increase radiation damage in various elements of the apparatus. We present measurements of the neutron group fluence and mean neutron multiplicity for muon capture on aluminum nuclei. Finally, we discuss an analysis of triboson production at CMS using an Effective Field Theory framework. Standard Model triboson production, which was first observed at CMS in 2020, has a relatively small cross section and provides direct access to both anomalous triple gauge couplings and quartic gauge couplings. These couplings, interpreted in the Standard Model Effective Field Theory, are studied in the present work. We target the boosted regime where the background rate is low and yields are enhanced when dimension-6 and dimension-8 Wilson coefficients are non-zero. We do not observe an excess in the data and therefore set bounds on the Wilson coefficients. For dimension-6 coefficients the tightest observed (expected) bounds are set on cW /Λ2 where Λ is the mass scale of new physics; the bounds are [−0.13, 0.12] TeV−2 ([−0.12, 0.12] TeV−2 ) at 95% CL. The tightest bounds in dimension-8 are set on fT,0 / Λ4 ; the observed (expected) bounds at 95% CL are [−0.63, 0.69] TeV−4 ([−0.54, 0.62] TeV−4 ). Additional results are presented which include scenarios where multiple Wilson coefficients are non-zero, the application of signal model clipping to address unitarity violation in Effective Field Theories, and a novel template fit developed for easier reinterpretation of our results.

Kampa, Cole Erik [Northwestern U. (main)] (ORCID:0↗

Development of 325 MHZ Single Spoke Resonators for HINS at Fermilab: Recent Results

The Fermilab High Intensity Neutrino Source (HINS) Linac R&D program is building a 60 MeV superconducting H^{−} linac. The Linac incorporates SC solenoids, high power RF vector modulators and SC spoke-type accelerating cavities starting at 10 MeV. This will be the first application and demonstration of any of these technologies in a low-energy, high-intensity proton/H^{−} linac. The HINS effort is relevant to a high intensity, SC H^{−} linac that might serve the next generation of neutrino physics and muon storage ring/collider experiments. Three types of superconducting resonators are used in the linac front end. Single Spoke Resonators type-1 (SSR1) at β=0.2, Single Spoke Resonators type-2 (SSR2) at β=0.4 and Triple Spoke Resonators (TSR) at β=0.6. In this paper we describe the Buffer Chemical Polishing (BCP) performed on SSR1-#2 and the results of the cold tests for this bare cavity. We also describe the inelastic tune performed on cavity SSR1-#1, during this operation we measured also the spring constant and the frequency sensitivity of the end walls. We have also completed the design for the helium vessel that will be used to jacket SSR1 resonators and we present its design here.

Ristori, L.↗

Measurement of the muon anomalous precession frequency in runs 4, 5, and 6 of the muon ${g}-2$ Experiment at Fermilab

The Fermilab E989 Muon $g-2$ experiment measures the muon's anomalous magnetic moment to a precision of 127 parts per billion, as reported in June 2025. The value is proportional to the difference between the muon's cyclotron frequency and the spin precession frequency in the presence of a uniform magnetic field, for muons contained within the $g-2$ storage ring. Spin precession frequency is extracted from the time distribution of the muon's decay positrons recorded by 24 electromagnetic calorimeters positioned around the inner circumference of the storage ring. The anomalous precession frequency is one of the primary experimental inputs necessary to estimate the anomalous magnetic moment, the other being the measurement of the magnetic field. This dissertation details the anomalous precession frequency extraction, including reconstruction, time-distribution fitting, and treatment of systematic uncertainties for the final three data-collection runs: Run-4, Run-5, and Run-6. This data represents a fourfold increase in statistics over the previous analysis release, halving the statistical uncertainty. The residual slow term from previous analyses is now well understood and documented in a systematic treatment. As of the writing of this dissertation, the theoretical prediction for the SM estimate of the muon's anomalous magnetic moment is under debate, with two competing prediction methods, so a definitive comparison with theory is not available. The results submitted for experimental release use the kernel-ratio asymmetry method, contributing 115 parts per billion to the statistical uncertainty and 34 parts per billion to the systematic uncertainty. When combined with the previous analyses in earlier data runs, this thereby improves the measurement beyond the experimental goal and sets the world's most precise measurement of the muon's anomalous magnetic moment.

Israel, Scott Nathan [Boston U.]↗

Measurement of the muon anomalous precession frequency in runs 4, 5, and 6 of the muon ${g}-2$ Experiment at Fermilab

The Fermilab E989 Muon $g-2$ experiment measures the muon's anomalous magnetic moment to a precision of 127 parts per billion, as reported in June 2025. The value is proportional to the difference between the muon's cyclotron frequency and the spin precession frequency in the presence of a uniform magnetic field, for muons contained within the $g-2$ storage ring. Spin precession frequency is extracted from the time distribution of the muon's decay positrons recorded by 24 electromagnetic calorimeters positioned around the inner circumference of the storage ring. The anomalous precession frequency is one of the primary experimental inputs necessary to estimate the anomalous magnetic moment, the other being the measurement of the magnetic field. This dissertation details the anomalous precession frequency extraction, including reconstruction, time-distribution fitting, and treatment of systematic uncertainties for the final three data-collection runs: Run-4, Run-5, and Run-6. This data represents a fourfold increase in statistics over the previous analysis release, halving the statistical uncertainty. The residual slow term from previous analyses is now well understood and documented in a systematic treatment. As of the writing of this dissertation, the theoretical prediction for the SM estimate of the muon's anomalous magnetic moment is under debate, with two competing prediction methods, so a definitive comparison with theory is not available. The results submitted for experimental release use the kernel-ratio asymmetry method, contributing 115 parts per billion to the statistical uncertainty and 34 parts per billion to the systematic uncertainty. When combined with the previous analyses in earlier data runs, this thereby improves the measurement beyond the experimental goal and sets the world's most precise measurement of the muon's anomalous magnetic moment.

Israel, Scott Nathan [Boston U.]↗

Measurement of the muon anomalous precession frequency in Runs 4, 5, and 6 of the Muon g-2 experiment at Fermilab

The Fermilab E989 Muon g − 2 experiment measures the muon’s anomalous magnetic moment to a precision of 127 parts per billion, as reported in June 2025. The value is proportional to the difference between the muon’s cyclotron frequency and the spin precession frequency in the presence of a uniform magnetic field, for muons contained within the g − 2 storage ring. Spin precession frequency is extracted from the time distribution of the muon’s decay positrons recorded by 24 electromagnetic calorimeters positioned around the inner circumference of the storage ring. The anomalous precession frequency is one of the primary experimental inputs necessary to estimate the anomalous magnetic moment, the other being the measurement of the magnetic field. This dissertation details the anomalous precession frequency extraction, including reconstruction, time-distribution fitting, and treatment of systematic uncertainties for the final three data-collection runs: Run-4, Run-5, and Run-6. This data represents a fourfold increase in statistics over the previous analysis release, halving the statistical uncertainty. The residual slow term from previous analyses is now well understood and documented in a systematic treatment. As of the writing of this dissertation, the theoretical prediction for the SM estimate of the muon’s anomalous magnetic moment is under debate, with two competing prediction methods, so a definitive comparison with theory is not available. The results submitted for experimental release use the kernel-ratio asymmetry method, contributing 115 parts per billion to the statistical uncertainty and 34 parts per billion to the systematic uncertainty. When combined with the previous analyses in earlier data runs, this thereby improves the measurement beyond the experimental goal and sets the world’s most precise measurement of the muon’s anomalous magnetic moment.

Israel, Scott Nathan [Boston U.]↗

Using Boosted Decision Trees to Select High Quality Measurements in the Mu2e Experiment at Fermilab

This thesis presents the implementation and evaluation of a Boosted Decision Tree (BDT) model to improve the selection of high-quality track measurements in the Mu2e experiment at Fermilab. The Mu2e experiment is a high-energy physics experiments seeking to observe a rare theoretical physics process known as Charged Lepton Flavor Violation. A significant challenge faced by the Mu2e experiment are so-called background events, which are events whose data mimics that of the rare physics process the experiment seeks to observe. Without a mechanism to reduce background, it would be impossible to know whether Charged Lepton Flavor Violation occurred or not. To this end, high-quality track measurements must be distinguished from low-quality track measurements. A track can be conceived of as the reconstructed path of a particle that traveled through the Mu2e detector. In addition to other data, data about such tracks is stored using a C++-based framework, specific to the domain of high-energy physics, known as ROOT. A boosted decision tree model was trained using ROOT’s Toolkit For Multivariate Analysis by leveraging variables ancillary to track quality. In evaluation, the BDT achieves a ROC-AUC of 0.927 in discriminating good-quality tracks from poor-quality tracks. Such a score is indicative of both strong discrimination and strong generalization. Subsequently, it is shown that applying a BDT-based quality cut to the distribution of particle momenta significantly enhances the signal-to-background distinction for signal electrons, paving the way for improved sensitivity to Charged Lepton Flavor Violation.

Mullany, Brendan T. [Drew U.] (ORCID:0009000818888↗

Testing General Relativity in Fermilab

Modern theories of the fundamental particles and the interactions among them have achieved a simple and coherent description of an unprecedented range of natural phenomena, but our new understanding raises intriguing new questions. Though there is a growing confidence in our ability to unify electroweak and strong interactions in a single gauge theory, gravity remains widely separated from the particle physics. In fact, road to a correct description of quantum gravity depends crucially on if experimental search methods end up with a negative or positive answer for the presence of higher-curvature space-time dimensions. Our theoretical study of general-relativistic gravitational force generated by a 1 Tev bunch of protons at Fermilab Tevatron accelerator demonstrates that the force has many similarities with the synchrotron radiation, and is in the range of sensitivity of modern low-frequency (torsion balance-type) detectors. Its measurement may open new fascinating opportunities for experimental study of the unification of gravity with other fundamental interactions presumably including the string theory.

43 PARTICLE ACCELERATORS↗

DZero Search for the Higgs at Fermilab

Fermilab DZero experiment representative Michael Kirby explains the Dzero experiment and their search for the Higgs Boson.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Challenges of Vapor Diffusion $Nb_3Sn$ Coating at Fermilab: Minimizing Impurities Using TOF-SIMS

Nb$_3$Sn demonstrates steady advancements nowadays offering reduced power cost in superconducting radio-frequency cavities due to its high critical temperature, quality factor, and achieved accelerating gradient. However, theoretical estimates of its radio-frequency parameters have not been achieved due to several potentially limiting mechanisms: tin spots, patchy regions, defects, thermal impedance, and impurities. While some of these limitations have been intensively studied, impurity analysis in Nb$_3$Sn coatings have received less attention. We report an investigation of impurities in several vapor-diffused Nb$_3$Snn coated samples using time-of-flight secondary ion mass spectroscopy (TOF-SIMS) and show allowable impurity levels in view of superconducting cavity performance. Challenges and lessons learned in maintaining clean Nb$_3$Sn coatings are also discussed.

Tagdulang, N. [Fermilab]↗

LLRF System Analysis for the Fermilab PIP-II LINAC

Developing long-lived quantum processing units (QPUs) capable of supporting high-fidelity quantum operations is a crucial challenge on the path toward fault-tolerant quantum computing. TESLA-shaped superconducting RF (SRF) cavities, known for photon relaxation times on the order of seconds, provide an excellent foundation for 3D QPUs and quantum memory. This talk presents a novel design that leverages TESLA cavity modes coupled to ancillary transmon qubits, optimized to preserve coherence and control. By carefully engineering the package geometry, optimizing Hamiltonian parameters, and minimizing lossy participation ratios, we achieve photon relaxation times of over 16 ms and 20 ms for the two cavity modes, representing a significant improvement over previous multimode quantum memories. Despite the reduced coupling between the qubit and cavity modes, which is necessary to preserve long lifetimes, the platform supports robust and universal control schemes that are not limited by low coupling strength. We will also discuss how this architecture can lead to scalable, modular quantum computing systems.

Varghese, P. [Fermilab]↗

LLRF System for the Fermilab Mu2e Project – AC Dipole Extinction

The Mu2e experiment measures the conversion rate of muons into electrons. The experiments requires 53 MHz batches of 8 GeV protons to be re-bunched into 150 ns, 2.5 MHz pulses for extraction to a single RF cavity running at 2.36 MHz. To meet stringent limits on the amount of beam between pulses, an Extinction System is used comprising of 2 AC dipole magnets (4.4MHz, 296Khz) and a collimator.

Guran, M. [Fermilab] (ORCID:0009000235538559)↗

Development of BPM Electronics for PIP-II at Fermilab

This paper presents the uTCA4.0-based BPM electronics for PIP-II, featuring four 250 MSPS ADCs and a Xilinx UltraScale+ MPSoC FPGA with 10 GbE uplink. Design elements include signal conditioning, clock, and thermal management. The FPGA performs signal processing, time tagging, digital down-conversion, and phase drift compensation. Position and phase resolution, and thermal stability is validated through dedicated testing.

Liu, Shengli [Fermilab] (ORCID:0009000128436936)↗

Development of BPM electronics for PIP-II at Fermilab

This paper presents the uTCA4.0-based BPM electronics for PIP-II, featuring four 250 MSPS ADCs and a Xilinx UltraScale+ MPSoC FPGA with 10 GbE uplink. Design elements include signal conditioning, clock, and thermal management. The FPGA performs signal processing, time tagging, digital down-conversion, and phase drift compensation. Position and phase resolution, and thermal stability - is validated through dedicated testing.

Liu, Shengli [Fermilab] (ORCID:0009000128436936)↗

Optimizing collimator positions using bayesian optimization in the Fermilab MI-8 transfer line

Collimators are used to minimize losses and to remove particles that would otherwise get lost downstream and irradiate the machine. Finding the optimal jaw positions is time consuming and with the upstream beam properties changing, the collimation settings would need to be readjusted each time. Therefore, a method to optimize collimator positions and to operate them at full capacity in a short time is required for loss control downstream. A study of collimator positions was conducted and a machine learning (ML) model was developed to predict optimal collimator positions. Bayesian Optimization (BO) was used to calculate new jaw positions from the ML model. The results of BO and usage of ML for better performance of the collimation system are presented in this paper.

Babacan, Betiay [Fermilab]↗

Design and testing of the New Muon Lab cryogenic system at Fermilab

Fermi National Accelerator Laboratory is constructing a superconducting 1.3 GHz cryomodule test facility located at the New Muon Lab building. The facility will be used for testing and validating cryomodule designs as well as support systems. For the initial phase of the project, a single Type III plus 1.3 GHz cryomodule will be cooled and tested using a single Tevatron style standalone refrigerator. Subsequent phases involve testing as many as two full RF units consisting of up to six 1.3 GHz cryomodules with the addition of a new cryogenic plant. The cryogenic infrastructure consists of the refrigerator system, cryogenic distribution system as well as an ambient temperature pumping system to achieve 2 K operations with supporting purification systems. A discussion of the available capacity for the various phases versus the proposed heat loads is included as well as commissioning results and testing schedule. This paper describes the plans, status and challenges of this initial phase of the New Muon Lab cryogenic system.

43 PARTICLE ACCELERATORS↗