Rare earth elements and critical metal content of extracted landfilled material and potential recovery opportunities

Highlights: • Samples from multiple core drills were obtained from 4× landfill sites in the UK. • Each sample analysed for rare earth elements, critical metals and valuable metals. • Two stage microwave digestion method ensuring high yield. • High quantities of copper and aluminium were observed in the soil layers of landfill. • Across 4× landfills aluminium and copper present has a value of around $400 million. - Abstract: Rare earth elements (REEs), Platinum group metals (PGMs) and other critical metals currently attract significant interest due to the high risks of supply shortage and substantial impact on the economy. Their uses in many applications have made them present in municipal solid waste (MSW) and in commercial and industrial waste (C&I), since several industrial processes produce by-products with high content of these metals. With over 4000 landfills in the UK alone, the aim of this study was to assess the existence of these critical metals within landfills. Samples collected from four closed landfills in UK were subjected to a two-step acid digestion to extract 27 metals of interest. Concentrations across the four landfill sites were 58 ± 6 mg kg{sup −1} for REEs comprising 44 ± 8 mg kg{sup −1} for light REEs, 11 ± 2 mg kg{sup −1} for heavy REEs and 3 ± 1 mg kg{sup −1} for Scandium (Sc) and 3 ± 1.0 mg kg{sup −1} of PGMs. Compared to the typical concentration in ores, these concentrations are too low to achieve a commercially viable extraction. However, content of other highly valuable metals (Al and Cu) was found in concentrations equating to a combined value across the four landfills of around $400 million, which increases the economic viability of landfill mining. Presence of critical metals will mainly depend on the type of waste that was buried but the recovery of these metals through landfill mining is possible and is economically feasible only if additional materials (plastics, paper, metallic items and other) are also recovered for reprocessing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Rapid Determination of Uranium Isotopic Abundance from Cotton Swipes: Direct Extraction via a Planar Surface Reader and Coupling to a Microplasma Ionization Source

The collection of solid particulates and liquids from surfaces by the use of cloth swipes is fairly ubiquitous. In such methods, there is a continuous concern regarding the ability to locate and quantitatively sample the analyte species from the material. In this effort, we demonstrate the initial coupling of an Advion Plate Express plate reader to a liquid sampling–atmospheric pressure glow discharge (LS-APGD) microplasma ionization source with an Orbitrap mass spectrometer to perform uranium isotopic analyses of solution residues on cotton swipes. The Plate Express employs a sampling probe head to engage and seal against the swipe surface. Subsequentially, the analyte residues are desorbed and transported within a 2% HNO 3 electrolyte flow to the ionization source. Quantitative recoveries were observed following a single 30 s extraction step, with the absolute mass sampled per extraction being ~100 ng. While the intrasample variability in the analytical responses for triplicate sampling of the same swipe yield ~30% RSD, this lack of precision is offset by the ability to determine isotope ratios for enriched uranium specimens with a precision of better than 10% RSD. Pooled, intersample precision ( n = 9) was found to be <5%RSD across the various sample compositions. Finally, 235 U/ 238 U determinations (ranging from 0.053 to 1.806) were accurate with errors of <10%, absolute. The 234 U- and 236 U-inclusive ratios were determined with similar accuracy in enriched samples. While the driving force for the effort is in the realm of nuclear nonproliferation efforts, the ubiquitous use of cloth swipes across many application areas could benefit from this convenient approach, including the use of versatile, reduced-format mass spectrometer systems.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Separation of Protactinium Employing Sulfur-Based Extraction Chromatographic Resins

Protactinium-230 (t 1/2 = 17.4 d) is the parent isotope of 230 U (t 1/2 = 20.8 d), a radionuclide of interest for targeted alpha therapy (TAT). Column chromatographic methods have been developed to separate no-carrier-added 230 Pa from proton irradiated thorium targets and accompanying fission products. Results reported within this paper demonstrate the use of novel sulfur bearing chromatographic extraction resins for the selective separation of protactinium. The recovery yield of 230 Pa was 93 ± 4% employing a R 3 P=S type commercially available resin and 88 ± 4% employing a DGTA (diglycothioamide) containing custom synthesized extraction chromatographic resin. The radiochemical purity of the recovered 230 Pa was measured via high purity germanium γ-ray spectroscopy to be >99.5% with the remaining radioactive contaminant being 95 Nb due to its similar chemistry to protactinium. Finally, measured equilibrium distribution coefficients for protactinium, thorium, uranium, niobium, radium, and actinium on both the R 3 P=S type and the DGTA resin in hydrochloric acid media are reported, to the best of our knowledge, for the first time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Techno-Economic Analysis and Life Cycle Assessment for the Separation of 2,3-Butanediol from Fermentation Broth Using Liquid–Liquid Extraction

It is energy-intensive to separate dilute 2,3-butanediol (2,3-BDO) (<10 wt %) from the aqueous phase of fermentation broth for sustainable aviation fuel (SAF) using conventional distillation. Liquid–liquid extraction (LLE) using oleyl alcohol as a solvent in a membrane extractor to extract BDO from water can significantly reduce the energy cost and minimize the potential emulsion. In an Aspen Plus model simulation, 95.2% BDO recovery and 97.1% BDO purity have been achieved using this LLE method with solvent recovery and heat integration. Here, the thermal energy cost was estimated to be 4.57 MJ/kg BDO, which is only about 16.8% of the lower heating value (LHV) of the BDO. This method consumes 81% less energy than the cascade distillation and reduces about $0.46/GGE (gasoline gallon equivalent) to the minimal fuel selling price. Meanwhile, the greenhouse gas (GHG) emission is 62% lower than petroleum-based jet fuel production and 34% less than using the cascade distillation.

09 BIOMASS FUELS↗

Machine Learning-Driven Solvent Screening for Biobased 2,3-Butanediol Extraction

Biobased 2,3-butanediol (2,3-BDO) is a valuable biomass-derived chemical due to its versatility in being transformed into a wide variety of products. However, the separation and purification of 2,3-BDO from fermentation broth remain a significant challenge owing to its high boiling point and hydrophilic nature. Herein, we developed a machine learning (ML)-based screening workflow that uses molecular calculations as training data and requires only a small number of experimental measurements for validation to identify alternative solvent candidates for the liquid–liquid extraction (LLE) of 2,3-BDO from aqueous solution. In particular, 130 density functional theory (DFT) calculations with the implicit solvation method not only built a correlation between the computational partition coefficient and the experimental distribution coefficient of 2,3-BDO but also parameterized an Extra-Trees ML model to screen the distribution coefficient for a wider range of 6717 organic solvents. The experimental measurements of only 24 solvents were needed to validate the computational results. A list of 50 prioritized solvents was proposed for 2,3-BDO LLE, and seven additional experimental measurements were conducted to further verify our selected solvents. The impact of the extraction temperature and solvent-to-feed ratio was also investigated for selected solvents in experiments. Furthermore, this work suggested alternative solvents for 2,3-BDO LLE and proposed a versatile workflow that requires fewer experiments and can be applied to a broader range of LLE studies.

Extraction↗

Computer-Aided Molecular Design of Bis-phosphine Oxide Lanthanide Extractants

Computer-aided molecular design and high-throughput screening of viable host architectures can significantly reduce the efforts in the design of novel ligands for efficient extraction of rare earth elements. This paper presents a computational approach to the deliberate design of bis-phosphine oxide host architectures that are structurally organized for complexation of trivalent lanthanides. Molecule building software, HostDesigner, was interfaced with molecular mechanics software, PCModel, providing a tool for generating and screening millions of potential R 2 (O)P-link-P(O)R 2 ligand geometries. The molecular mechanics ranking of ligand structures is consistent with both the solution-phase free energies of complexation obtained with density functional theory and the performance of known bis-phosphine oxide extractants. For the case where link is -CH 2 -, evaluation of the ligand geometry provides the first characterization of a steric origin for the ‘anomalous aryl strengthening’ effect. The design approach has identified a number of novel bis-phosphine oxide ligands that are better organized for lanthanide complexation than previously studied examples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

How Beneficial Is Pretraining on a Narrow Domain-Specific Corpus for Information Extraction about Photocatalytic Water Splitting?

Language models trained on domain-specific corpora have been employed to increase the performance in specialized tasks. However, little previous work has been reported on how specific a “domain-specific” corpus should be. Here, we test a number of language models trained on varyingly specific corpora by employing them in the task of extracting information from photocatalytic water splitting. We find that more specific corpora can benefit performance on downstream tasks. Furthermore, PhotocatalysisBERT, a pretrained model from scratch on scientific papers on photocatalytic water splitting, demonstrates improved performance over previous work in associating the correct photocatalyst with the correct photocatalytic activity during information extraction, achieving a precision of 60.8(+11.5)% and a recall of 37.2(+4.5)%.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MechBERT: Language Models for Extracting Chemical and Property Relationships about Mechanical Stress and Strain

Language models are transforming materials-aware naturallanguage processing by enabling the extraction of dynamic, context-rich information from unstructured text, thus, moving beyond the limitations of traditional information-extraction methods. Moreover, small language models are on the rise because some of them can perform better than large language models (LLMs) when given domain-specific questionanswer tasks, especially about an application area that relies on a highly specialized vernacular, such as materials science. We therefore present a new class of MechBERT language models for understanding mechanical stress and strain in materials. These employ Bidirectional Encoder Representations for transformer (BERT) architectures. We showcase four MechBERT models, all of which were pretrained on a corpus of documents that are textually rich in chemicals and their stress–strain properties and were fine-tuned on question-answering tasks. We evaluated the level of performance of our models on domain-specific as well as general English-language question-answer tasks and also explored the influence of the size and type of BERT architectures on model performance. We find that our MechBERT models outperform BERT-based models of the same size and maintain relevancy better than much larger BERT-based models when tasked with domain-specific question-answering tasks within the stress–strain engineering sector. These small language models also enable much faster processing and require a much smaller fraction of data to pretrain them, affording them greater operational efficiency and energy sustainability than LLMs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tracking Molecular Transport Across Oil/Aqueous Interfaces: Insight into “Antagonistic” Binding in Solvent Extraction

Liquid/liquid (L/L) interfaces play a key, yet poorly understood, role in a range of complex chemical phenomena where time-evolving interfacial structures and transient supramolecular assemblies act as gatekeepers to function. Here, for this study, we employ surface-specific vibrational sum frequency generation combined with neutron and X-ray scattering methods to track the transport of dioctyl phosphoric acid (DOP) and di-(2-ethylhexyl) phosphoric acid (DEHPA) ligands used in solvent extraction at buried oil/aqueous interfaces away from equilibrium. Our results show evidence for a dynamic interfacial restructuring at low ligand concentrations in contrast to expectation. These time-varying interfaces arise from the transport of sparingly soluble interfacial ligands into the neighboring aqueous phase. These results support a proposed “antagonistic” role of ligand complexation in the aqueous phase that could serve as a holdback mechanism in kinetic liquid extractions. These findings provide new insights into interfacially controlled chemical transport at L/L interfaces and how these interfaces vary chemically, structurally, and temporally in a concentration-dependent manner and present potential avenues to design selective kinetic separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of Sequentially Extracted Soil Organic Matter by Electrospray Ionization and Atmospheric Pressure Photoionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry

Soil organic matter (SOM) is a complex mixture of small molecules and biopolymers that are active in various biogeochemical processes. However, the chemical diversity of biopolymer-derived SOM remains poorly explored. Identifying this diversity is important because global environmental changes may well alter SOM chemistry, as field experiments are beginning to show. Here, organic solvent-extractable (DcMe-SOM), base-hydrolyzable (KOH Hy -SOM), and CuO-oxidizable (CuO Ox -SOM) SOM fractions from a forest with a long-term nitrogen addition experiment were sequentially extracted and characterized by Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) coupled with negative-ion electrospray ionization (ESI) or atmospheric pressure photoionization (APPI). From DcMe-SOM to CuO Ox -SOM, the total number of assigned formulas, average O/C ratio, aromaticity, and unsaturation degree of SOM continuously increased, while the average m/z and H/C ratio decreased. Moreover, the dominant chemical category shifted from lipid-like components to phytochemical- and protein-like components. Complementary to ESI, APPI effectively facilitated detection of additional compounds with low polarity. With long-term nitrogen addition, the average m/z, unsaturation degree, aromaticity, and oxidation state of SOM increased, and more aromatic nitrogen-containing formulas were detected in CuOOx-SOM. Our study demonstrates that chronic nitrogen deposition in forests alters both the small molecules and biopolymers of SOM fundamentally.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Conformationally Adaptable Extractant Flexes Strong Lanthanide Reverse-Size Selectivity

Chemical selectivity is traditionally understood in the context of rigid molecular scaffolds with precisely defined local coordination and chemical environments that ultimately facilitate a given transformation of interest. By contrast, nature leverages dynamic structures and strong coupling to enable specific interactions with target species in otherwise complex media. Taking inspiration from nature, we demonstrate unconventional selectivity in the solvent extraction of light over heavy lanthanides using a conformationally flexible ligand called octadecyl acyclopa (ODA). This novel ligand forms pseudocyclic molecular complexes with lanthanide ions at organic/aqueous interfaces, revealed by vibrational sum frequency generation spectroscopy. These complexes are extracted into the organic phase, where femtosecond structural dynamics are probed by two-dimensional infrared spectroscopy and ab initio molecular dynamics simulations to mechanistically frame the macroscopic selectivity trends. We find larger-than-expected structural fluctuations and bond lengths for heavy Ln–ODA complexes that arise from an inability of ODA to contort around the smaller ions to satisfy all would-be bonding interactions, despite forming some individually strong bonds. This finding contrasts with the binding of ODA with lighter lanthanides where, despite individually weaker bonds, collective interactions manifest that minimize structural fluctuations and give rise to enhanced thermodynamic stability. Furthermore, these results point to a new paradigm where conformational dynamics and cumulative bonding interactions can be used to facilitate unconventional chemical transformations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and Evaluation of a Tethered, Open Port Sampling Interface for Liquid Extraction-Mass Spectrometry Chemical Analysis

Presented in this work is a tethered, liquid-extraction-sampling interface designed for the mass spectrometric surface sampling/analysis of 3D objects. The tethered, open port sampling interface (TOPSI) incorporates a vacuum line between the sampling probe and ionization source, which enables the ability for an extended, tethered sample transfer line. Herein, several designs of the hand-held TOPSI are presented and evaluated on the basis of the analytical metrics of analyte transport time, peak width, and analyte sensitivity. The best analytical metrics were obtained with capillary flow resistances arranged in a particular order and the vacuum region set at 6.2 kPa. This TOPSI design incorporated a transfer capillary 1 m in length, while retaining a fast analyte transport time (12 s), short signal peak width (5 s baseline-to-baseline), and high analyte signal at 90% of that obtained with a regular open port sampling interface (OPSI). The hand-held TOPSI was demonstrated for the characterization of extracted small molecules and metabolites from the surface of mint and rosemary leaves.

47 OTHER INSTRUMENTATION↗

Synergism by co-assembly at the origin of ion selectivity in liquid-liquid extraction

In liquid-liquid extraction, synergism emerges when for a defined formulation of the solvent phase, there is an increase of distribution coefficients for some cations in a mixture. To characterize the synergistic mechanisms, we determine the free energy of mixed co-assembly in aggregates. Aggregation in any point of a phase diagram can be followed not only structurally by SANS, SAXS, and SLS, but also thermodynamically by determining the concentration of monomers coexisting with reverse aggregates. Using the industrially used couple HDEHP/TOPO forming mixed reverse aggregates, and the representative couple U/Fe, we show that there is no peculiarity in the aggregates microstructure at the maximum of synergism. Nevertheless, the free energy of aggregation necessary to form mixed aggregates containing extracted ions in their polar core is comparable to the transfer free energy difference between target and nontarget ions, as deduced from the synergistic selectivity peak. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of an autonomous solvent extraction system to isolate astatine-211 from dissolved cyclotron bombarded bismuth targets

Abstract Cyclotron-produced astatine-211 ( 211 At) shows tremendous promise in targeted alpha therapy (TAT) applications due to its attractive half-life and its 100% α-emission from nearly simultaneous branched alpha decay. Astatine-211 is produced by alpha beam bombardment of naturally monoisotopic bismuth metal ( 209 Bi) via the ( α, 2n ) reaction. In order to isolate the small mass of 211 At (specific activity = 76 GBq·µg −1 ) from several grams of acid-dissolved Bi metal, a manual milliliter-scale solvent extraction process using diisopropyl ether (DIPE) is routinely performed at the University of Washington. As this process is complex and time consuming, we have developed a fluidic workstation that can perform the method autonomously. The workstation employs two pumps to concurrently deliver the aqueous and organic phases to a mixing tee and in-line phase mixer. The mixed phases are routed to a phase settling reservoir, where they gravity settle. Finally, each respective phase is withdrawn into its respective pump. However, development of a phase boundary sensor, placed in tandem with the phase settling reservoir, was necessary to communicate to the system when withdrawal of the denser aqueous phase was complete (i.e., the intersection of the two phases was located). The development and optimization of the autonomous solvent extraction system is described, and the 211 At yields from several ~1.1 GBq-level 211 At processing runs are reported.

211At↗

Solvent selection for biphasic extraction of 5-hydroxymethylfurfural via multiscale modeling and experiments

We introduce a comprehensive conceptual framework for selecting solvents for reactive extraction in biphasic organic-water systems and demonstrate it for the separation of HMF (5-hydroxylmethylfurfural), a platform chemical produced in the acid-catalyzed dehydration of hexoses. We first perform in silico screening of ~2500 solvents, from the ADFCRS-2018 database using the ADF COSMO-RS implementation, and classification, based on the solvent partition coefficient. We then determine experimentally the partition coefficients for HMF, fructose, and products of HMF rehydration (levulinic acid (LA), and formic acid (FA)), the mutual water-organic solvent solubilities, and the separation factors in >50 select solvents spanning multiple homologous series at room temperature and a typical reaction temperature with in situ sampling. We find that COSMO-RS is excellent for screening purposes (typical error in most cases within a factor of ~2). Increased temperatures lead to significant reduction in partitioning, and room temperature measurements are clearly inadequate for solvent selection. Upon down selecting classes of solvents based on separation performance, we perform experimental thermal stability and reaction compatibility studies of a small set of solvents at relevant reactive-extraction temperatures. We discover that many substituted phenols exhibit an order-of-magnitude increase in partitioning compared to conventional solvents due chiefly to hydrogen bond interactions and show the necessary stability but retain a significant fraction of water and LA, factors that need to be considered in technoeconomic analysis. In contrast, anilines, aldehydes, and acids are good to excellent regarding separation but incompatible with this specific reaction medium. Furthermore, this multifaceted framework can be extended to other biomass-derived products and processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Extraction and Acceleration of Ions from an Ion-Ion Plasma

Extraction and acceleration of positive and negative ions from a strong electronegative plasma and from an ion-ion plasma is investigated in the PEGASES thruster, working with SF{sub 6}. The plasma is generated in a cylindrical quartz tube terminated by metallic endplates. The electrons are confined by a static magnetic field along the axis of the cylinder. The electron mobility along the field is high and the electrons are determining the sheaths in front of the endplates. The core plasma potential can therefore be controlled by the bias applied to the endplates. An ion-ion plasma forms at the periphery as a result of electron confinement and ions can freely diffuse along the perpendicular direction or extraction axis. Langmuir probe and RFEA measurements are carried out along this axis. The measured ion energy distributions shows a single peak centered around a potential consistent with the plasma potential and the peak position could be controlled with a positive voltage applied to the endplates. When the endplates are biased negatively, the plasma potential saturates and remained close to 15 V. A beam of negatively charged particles can be observed under certain conditions when the endplates were biased negatively.

43 PARTICLE ACCELERATORS↗

Test bench to commission a third ion source beam line and a newly designed extraction system

The HIT (Heidelberg Ion Beam Therapy Center) is the first hospital-based treatment facility in Europe where patients can be irradiated with protons and carbon ions. Since the commissioning starting in 2006 two 14.5 GHz electron cyclotron resonance ion sources are routinely used to produce a variety of ion beams from protons up to oxygen. In the future a helium beam for regular patient treatment is requested, therefore a third ion source (Supernanogan source from PANTECHNIK S.A.) will be integrated. This third ECR source with a newly designed extraction system and a spectrometer line is installed at a test bench at HIT to commission and validate this section. Measurements with different extraction system setups will be presented to show the improvement of beam quality for helium, proton, and carbon beams. An outlook to the possible integration scheme of the new ion source into the production facility will be discussed.

43 PARTICLE ACCELERATORS↗

Progress towards the development of a realistic electron cyclotron resonance ion source extraction model

In this paper, an ongoing effort to provide a simulation and design tool for electron cyclotron resonance ion source extraction and low energy beam transport is described and benchmarked against experimental results. Utilizing the particle-in-cell code WARP, a set of scripts has been developed: A semiempirical method of generating initial conditions, a 2D-3D hybrid method of plasma extraction and a simple beam transport deck. Measured emittances and beam profiles of uranium and helium beams are shown and the influence of the sextupole part of the plasma confinement field is investigated. The results are compared to simulations carried out using the methods described above. The results show that the simulation model (with some additional refinements) represents highly charged, well-confined ions well, but that the model is less applicable for less confined, singly charged ions.