Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Expression systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Bending Magnet Synchrotron Radiation Imaging with Large Orbital Collection Angles

Synchrotron radiation (SR) from bending magnets, wigglers, and undulators is now extensively produced for users at storage ring based light sources, with unique properties in terms of average brightness and stability. Here, we present a profound study of bending magnet SR intensity distribution in the image plane of a focusing optical system. Measurements of this intensity distribution at the MAX-IV low emittance storage ring are compared to theoretical predictions, and found to be in excellent agreement. This work shows upon the possibility of performing high resolution emittance diagnostics with visible or near-visible SR on upcoming low-emittance storage ring based light sources. As a byproduct of our study, we derive a closed analytical expression for the intensity distribution from a zero-emittance beam, in the limiting case of wide orbital collection angles. This expression finally allows us to demonstrate the meeting between classical electrodynamics applied to SR emission and focusing, and the Landau and Lifshitz prediction of radiation intensity distribution nearby a caustic.

36 MATERIALS SCIENCE↗

Modeling of RMS Current in CSI Filter Capacitor and Minimum Conduction Loss Operation of CSI-Fed PMSM Drives for Traction Applications

This paper presents a new minimum conduction loss (MCL) torque control algorithm for current source inverter- (CSI-) fed permanent-magnet synchronous machine drives that improves the overall machine drive efficiency by minimizing the combined conduction losses in the inverter and machine at each operating point. First, analytical models of conduction losses in CSI-fed motor drives are presented, and a closed-form expression for optimal d-axis stator current to achieve MCL operation is derived. An expression for the rms current in both wye- and delta-connected CSI output capacitors is derived. A detailed simulation model that emulates the operation of a 100 kW SiC CSI-fed integrated machine drive (IMD) has been developed based on experimental results and finite element analysis. This simulation model is used to evaluate the proposed MCL control algorithm applied to a CSI-fed IMD system for a battery-electric vehicle traction drive, and the predicted total drive system loss with MCL control is compared to predicted losses with maximum-torque-per-ampere (MTPA) and minimum dc-link current (MDCC) control. Results show that MCL control can achieve loss reductions compared to the other two control algorithms over a wide range of operating conditions, with significant loss reductions >20% in the medium-speed regime.

42 ENGINEERING↗

Tamper indicating seal

A system and method for detecting tampering with a seal is provided. A loop seal tamper indicating device includes a seal wire that may be passed through a secured item or container to form a loop with the free ends of the seal wire passing through a seal housing. A plunger body including an adhesive-filled cavity is inserted into the seal housing, such that a piston expresses the adhesive into the space between the seal housing and the plunger body. The adhesive may contain reflective particles and is cured to fix the particles and the adhesive in place. A reference image may be taken to record the unique identifier and reflective signature of the adhesive. Future validation images may be compared to the reference image to determine whether the reflective signature has changed, thus indicating that the seal has been tampered with.

42 ENGINEERING↗

RRNPP-type quorum-sensing systems regulate solvent formation, sporulation and cell motility in Clostridium saccharoperbutylacetonicum

Abstract Background Clostridium saccharoperbutylacetonicum N1-4 (HMT) is a strictly anaerobic, spore-forming Gram-positive bacterium capable of hyper-butanol production through the well-known acetone–butanol–ethanol fermentation process. Recently, five putative RRNPP-type QSSs (here designated as QSS1 to QSS5) were predicted in this bacterial strain, each of which comprises a putative RRNPP-type regulator (QssR1 to QssR5) and a cognate signaling peptide precursor (QssP1 to QssP5). In addition, both proteins are encoded by the same operon. The functions of these multiple RRNPP-type QSSs are unknown. Results To elucidate the function of multiple RRNPP-type QSSs as related to cell metabolism and solvent production in N1-4 (HMT), we constructed qssR -deficient mutants ΔR1, ΔR2, ΔR3 and ΔR5 through gene deletion using CRISPR–Cas9 and N1-4-dcas9-R4 (with the QssR4 expression suppressed using CRISPR–dCas9). We also constructed complementation strains by overexpressing the corresponding regulator gene. Based on systematic characterization, results indicate that QSS1, QSS2, QSS3, and QSS5 positively regulate the sol operon expression and thus solvent production, but they likely negatively regulate cell motility. Consequently, QSS4 might not directly regulate solvent production, but positively affect cell migration. In addition, QSS3 and QSS5 appear to positively regulate sporulation efficiency. Conclusions Our study provides the first insights into the roles of multiple RRNPP-type QSSs of C. saccharoperbutylacetonicum for the regulation of solvent production, cell motility, and sporulation. Results of this study expand our knowledge of how multiple paralogous QSSs are involved in the regulation of essential bacterial metabolism pathways.

09 BIOMASS FUELS↗

Revisiting Theoretical Limits for One-Degree-of-Freedom Wave Energy Converters

This work revisits the theoretical limits of one-degree-of-freedom wave energy converters. This paper considers the floating sphere used in the Ocean Energy Systems Task 10 Wave Energy Converter modeling and verification effort for analysis. Analytical equations are derived to determine bounds on the motion amplitude, time-averaged power, and power-take-off (PTO) force. A unique result was found that shows the time-averaged power absorbed by a wave energy converter can be defined solely by the inertial properties and radiation hydrodynamic coefficients. In addition, a unique expression for the PTO force amplitude was derived that has provided upper and lower bounds when resistive control is used to maximize power generation. For complex conjugate control, this same expression can only provide a lower bound, as there is theoretically no upper bound. These bounds are used to compare the performance of a floating sphere if it were to extract energy using surge or heave motion. The analysis shows that because of the differences in hydrodynamic coefficients of each oscillating mode, there will be different frequency ranges that provide better power capture efficiency. The influence of a motion constraint on power absorption while also utilizing a nonideal power take-off is examined and found to reduce the losses associated with bidirectional energy flow. The expression to calculate the time-averaged power with a nonideal PTO is modified by the mechanical-to-electrical efficiency and the ratio of the PTO spring and damping coefficients. The PTO spring and damping coefficients were separated in the expression, which allows for limits to be set on the possible values of PTO coefficients to ensure a net flow of power to the grid.

50 EE - Wind and Water Power Program - Water (EE-4↗

Eddy Current Shielding of the Magnetic Field Ripple in the EIC Electron Storage Ring Vacuum Chambers

The EIC electron storage ring (ESR) has very tight tolerances for the beam position and size stability at the interaction point. The oscillations at the proton betatron frequency and its harmonics are the most dangerous because, for instance, they could lead to unacceptable proton emittance growth from the oscillating beam-beam kick from the electrons at the amplitude of the positional oscillations as low as 10 -4 of the beam size. Even at much lower frequencies, down to the single Hz range, the position oscillations at a few percent level of the nominal beam size were found to be dangerous. These oscillations could have different causes including magnet power supply ripple, mag net vibration, noise in the main and crab RF systems, and some collective instabilities. To specify the acceptable level of the current ripple and noise of the magnet power supplies we need to accurately account for the eddy current shielding by the vacuum chamber, as well as, potentially, by the laminated magnet yokes (considered elsewhere). With some ap proximations, the chamber shielding can be described analytically. The main objective of this note is to derive these analytical expressions and to document the resulting shielding performance of the ESR chamber.

43 PARTICLE ACCELERATORS↗

An EvoDevo Study of Salmonid Visual Opsin Dynamics and Photopigment Spectral Sensitivity

Salmonids are ideal models as many species follow a distinct developmental program from demersal eggs and a large yolk sac to hatching at an advanced developmental stage. Further, these economically important teleosts inhabit both marine- and freshwaters and experience diverse light environments during their life histories. At a genome level, salmonids have undergone a salmonid-specific fourth whole genome duplication event (Ss4R) compared to other teleosts that are already more genetically diverse compared to many non-teleost vertebrates. Thus, salmonids display phenotypically plastic visual systems that appear to be closely related to their anadromous migration patterns. This is most likely due to a complex interplay between their larger, more gene-rich genomes and broad spectrally enriched habitats; however, the molecular basis and functional consequences for such diversity is not fully understood. This study used advances in genome sequencing to identify the repertoire and genome organization of visual opsin genes (those primarily expressed in retinal photoreceptors) from six different salmonids [Atlantic salmon ( Salmo salar ), brown trout ( Salmo trutta ), Chinook salmon ( Oncorhynchus tshawytcha ), coho salmon ( Oncorhynchus kisutch ), rainbow trout ( Oncorhynchus mykiss ), and sockeye salmon ( Oncorhynchus nerka )] compared to the northern pike ( Esox lucius ), a closely related non-salmonid species. Results identified multiple orthologues for all five visual opsin classes, except for presence of a single short-wavelength-sensitive-2 opsin gene. Several visual opsin genes were not retained after the Ss4R duplication event, which is consistent with the concept of salmonid rediploidization. Developmentally, transcriptomic analyzes of Atlantic salmon revealed differential expression within each opsin class, with two of the long-wavelength-sensitive opsins not being expressed before first feeding. Also, early opsin expression in the retina was located centrally, expanding dorsally and ventrally as eye development progressed, with rod opsin being the dominant visual opsin post-hatching. Modeling by spectral tuning analysis and atomistic molecular simulation, predicted the greatest variation in the spectral peak of absorbance to be within the Rh2 class, with a ∼40 nm difference in λ max values between the four medium-wavelength-sensitive photopigments. Overall, it appears that opsin duplication and expression, and their respective spectral tuning profiles, evolved to maximize specialist color vision throughout an anadromous lifecycle, with some visual opsin genes being lost to tailor marine-based vision.

59 BASIC BIOLOGICAL SCIENCES↗

Ultra-high Information-content Chemical Imaging with Broadband Coherent Anti-Stokes Raman and Two-photon Fluorescence Lifetime Microscopy

Raman fingerprint spectroscopy and fluorescence lifetime imaging are emerging tools for studying metabolic profiles of biological specimens. While Raman fingerprint spectroscopy detects intrinsic molecular vibrations that reflect the molecular composition and chemical environment of a sample, fluorescence lifetime imaging measures changes in the excited-state lifetime of fluorophores that are sensitive to their microenvironments. Here, we present a multimodal imaging platform combining broadband coherent anti-Stokes Raman scattering (BCARS) and two-photon fluorescence lifetime imaging (2p-FLIM) microscopy that can acquire biologically relevant Raman fingerprint spectra and fluorescence lifetime signals in vivo and simultaneously. The tremendous chemical information obtained from spatially co-registered BCARS and 2p-FLIM images allows us to characterize the subtle differences between sub-cellular compartments and verify the potential false-positive results generated by fluorescence imaging alone. This is demonstrated by directly comparing the BCARS, 2p-FLIM, and two-photon excitation fluorescence(TPEF) signals simultaneously obtained from the same dye-stained organelle in the live, intact C. elegans expressing a green fluorescent protein (GFP) marker. In this work, we introduce the BCARS/2p-FLIM/TPEF setup scheme, the image acquisition steps, data processing, and representative results showing that the cross-modality imaging method enables rigorous characterization and in vivo detection at sub-cellular resolution. Furthermore, this protocol provides a framework for simultaneous chemical and fluorescence lifetime imaging to improve the accuracy of biological interpretation in complex living systems.

Xu, Haoyu [Georgia Institute of Technology, Atlant↗

Mind the crosscap: $τ$-scaling in non-orientable gravity and time-reversal-invariant systems

Spectral statistics of quantum chaotic systems are governed by random matrix universality. In many cases of interest, time-reversal symmetry selects the Gaussian Orthogonal Ensemble (GOE) as the relevant universality class. In holographic CFTs, this is mirrored by the presence of non-orientable geometries in the dual gravitational path integral. In this work, we analyze general properties of these matrix models and their gravitational counterparts. First, we develop a formalism to express the universal level statistics in the canonical ensemble for arbitrary spectral curves, leading to a topological expansion with finite radius of convergence in the late-time $τ$-scaling limit. Then, we focus on topological gravity and study topological recursion on the moduli space of non-orientable surfaces. We find that the Weil-Petersson volumes display non-analytic behaviour multiplying polynomials in the boundary lengths. The volumes give rise to wormholes with late-time divergences, in contrast with the orientable case, which is finite. We identify systematic cancellations among WP volumes implied by the consistency and finiteness of the $τ$-scaling limit. In particular, the cancellation of late-time divergences requires a nontrivial genus resummation. Working in the gravitational microcanonical ensemble, we derive and resum all orders of the topological expansion matching the GOE matrix model in the high-energy regime.

Chaotic Dynamics (nlin.CD)↗

Revisiting Theoretical Limits for One-Degree-of-Freedom Wave Energy Converters: Preprint

This work revisits the theoretical limits of one-degree of freedom wave energy converters (WECs). This paper considers the floating sphere used in the Ocean Energy Systems (OES) Task 10 Wave Energy Converter modeling and verification effort for analysis. Analytical equations are derived to determine bounds on the motion amplitude, time-averaged power, and power take-off (PTO) force. A unique result was found that shows the time-averaged power absorbed by a WEC can be defined solely by the inertial properties and the radiation hydrodynamic coefficients. In addition, a unique expression for the PTO force amplitude was derived which has provided upper and lower bounds when resistive control is used to maximize power generation. For complex conjugate control, this same expression can only provide a lower bound as there is theoretically no upper bound. These bounds are used to compare the performance of a floating sphere if it were to extract energy using surge or heave motion. The analysis shows that because of the differences in hydrodynamic coefficients of each oscillating mode there will be different frequency ranges that provide better power capture efficiency. The influence of a motion constraint on power absorption while also utilizing a nonideal power take-off is examined and found to reduce the losses associated with bidirectional energy flow. The expression to calculate the time-averaged power with a nonideal PTO is modified by the mechanical-to-electrical efficiency and the ratio of the PTO spring and damping coefficients. These were separated in the expression which allows for limits to be set on the possible values of PTO coefficients to ensure a net flow of power to the grid.

50 EE - Wind and Water Power Program - Water (EE-4↗

Development of a prediction model for radiotherapy response among patients with head and neck squamous cell carcinoma based on the tumor immune microenvironment and hypoxia signature

Abstract Introduction The immune system and hypoxia are major factors influencing radiosensitivity in patients with different cancer types. This study aimed at developing a model to predict radiotherapy response in patients with head and neck squamous cell carcinoma (HNSCC) based on the tumor immune microenvironment and hypoxia signature. Materials and Methods We first evaluated the hypoxia status and tumor immune microenvironment in the Cancer Genome Atlas (TCGA) cohort by using transcriptomic data. Differentially expressed genes (DEGs) were identified between the “high immunity and low hypoxia” and “low immunity and high hypoxia” groups and those DEGs significantly associated with disease‐specific survival in the univariate Cox regression analysis were selected as the prognostic DEGs. We selected the immune hypoxia–related genes (IHRGs) by intersecting prognostic DEGs with immune and hypoxia gene sets. We used the IHRGs to train a multivariate Cox regression model in the TCGA cohort, based on which we calculated the IHRG prognostic index (IHRGPI) for each patient and validated its efficacy in predicting radiotherapy response in the Gene Expression Omnibus cohorts. Furthermore, we explored potential mechanisms and effective combinational treatment strategies for different IHRGPI groups. Results Five IHRGs were used to construct the IHRGPI, which was used to dichotomize the cohorts. The patients with lower IHRGPI showed a better radiotherapy response across different cohorts and endpoints, including overall survival, progression‐free survival, and recurrence‐free survival ( p < 0.05). Patients with higher IHRGPI showed greater hypoxia and lesser immune cell infiltration. A lower IHRGPI indicated a better immunotherapy response, while a higher IHRGPI indicated a better chemotherapy response. Conclusions IHRGPI is promising for predicting radiotherapy response and guiding combinational treatment strategies in patients with HNSCC.

Zhu, Guang‐Li↗

A small number of point mutations confer formate tolerance in Shewanella oneidensis

ABSTRACT Microbial electrosynthesis (MES) is a sustainable approach to chemical production from CO 2 and clean electricity. However, limitations in electron transfer efficiency and gaps in understanding of electron transfer pathways in MES systems prevent full realization of this technology. Shewanella oneidensis could serve as an MES biocatalyst because it has a well-studied, efficient transmembrane electron transfer pathway. A key first step in MES in this organism could be CO 2 reduction to formate. However, we report that wild-type S. oneidensis does not tolerate high levels of formate. In this work, we created and characterized formate-tolerant strains of S. oneidensis for further engineering and future use in MES systems through adaptive laboratory evolution. Two different point mutations in a gene encoding a predicted sodium-dependent bicarbonate transporter and a DUF2721-containing protein separately confer formate tolerance to S. oneidensis . The mutations were further evaluated to understand their role in improving formate tolerance. We also show that the wild-type and mutant versions of the putative sodium-dependent bicarbonate transporter improve formate tolerance of Zymomonas mobilis , indicating the potential of transferring this formate tolerance phenotype to other organisms. IMPORTANCE Shewanella oneidensis is a bacterium with a well-studied, efficient extracellular electron transfer pathway. This capability could make this organism a suitable host for microbial electrosynthesis using CO 2 or formate as feedstocks. However, we report here that formate is toxic to S. oneidensis , limiting the potential for its use in these systems. In this work, we evolve several strains of S. oneidensis that have improved formate tolerance, and we investigate some mutations that confer this phenotype. The phenotype is confirmed to be attributed to several single point mutations by transferring the wild-type and mutant versions of each gene to the wild-type strain. Finally, the formate tolerance mechanism of one variant is studied using structural modeling and expression in another host. This study, therefore, presents a simple method for conferring formate tolerance to bacterial hosts.

Cross, Megan C. Gruenberg (ORCID:0000000291589900)↗

Multifamily Building Stock Modeling: Cooperative Research and Development Final Report, CRADA Number CRD-17-00701

U.S. multifamily buildings house 35 million households, consuming 4 quads of source energy and spending $48 billion on utility bills every year. Almost all of these households live in urban areas, where cities are taking the lead on setting aggressive energy goals. Cities currently do not have the data and tools necessary to identify and target opportunities to save energy in their building stock. Building on the open-source, OpenStudio-based ResStock platform, this project will extend the publicly-available ResStock modeling capabilities to the multifamily sector, enabling Radiant Labs, and others, to partner with cities to market and strategically deploy cost-effective, energy efficiency (EE) upgrades directly to high-priority households. Radiant Labs has been successful in using ResStock's single-family capabilities to provide value to the City of Boulder, Colorado. However, lack of multifamily capabilities in ResStock is a roadblock for Radiant Labs working with New York City, San Francisco, Washington, D.C., and other cities that have expressed significant interest in working with them. In addition, other cities, companies, and utilities can use these open-source capabilities to grow their EE portfolios, thereby multiplying the impact of this project. This work also enables national-scale analysis of EE potential in multifamily buildings, which is of strong interest to a variety of stakeholders, including the U.S. Department of Energy (DOE) Office of Energy Policy and Systems Analysis (EPSA), DOE Weatherization Assistance Program (WAP), U.S. Department of Housing and Urban Development (HUD), and the Bonneville Power Administration (BPA).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory Protected Areas Database of the United States (PAD-US) areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)↗

Energy Infrastructure Futures: A Multiscale Evaluation of Projected Power Plant Siting Across the Western Interconnection

Energy Infrastructure Futures: A Multiscale Evaluation of Projected Power Plant Siting Across the Western Interconnection Description This dataset contains input and output data for the manuscript Mongird, K. et al. (under review) titled "Energy Infrastructure Futures: A Multiscale Evaluation of Projected Power Plant Siting Across the Western Interconnection". Input data corresponds to gridded spatial siting attributes that are necessary to conduct a random forest machine learning analysis of siting feature importance. Output data includes SHAP feature analysis outputs, and classification report values. For data on power plant siting results referred to in the manuscript, please refer to the CERF: IM3 Projected Western US Power Plant Locations data download page. The downloadable data includes values for eight different future scenarios for the Western US. The scenarios include combinations of two Shared Socioeconomic Pathways (SSP3 and SSP5) with four high-resolution climate projections specific to the United States (see, https://tgw-data.msdlive.org/). These climate projections include "hotter" and "cooler" variants for two Representative Concentration Pathways (RCP4.5 and RCP8.5). The resulting eight simulations are: rcp45cooler_ssp3 rcp45cooler_ssp5 rcp45hotter_ssp3 rcp45hotter_ssp5 rcp85cooler_ssp3 rcp85cooler_ssp5 rcp85hotter_ssp3 rcp85hotter_ssp5 Technical Information The dataset includes two sets of data files: (1) CERF gridded siting parameters and (2) Feature analysis outputs and classification reports. All downloadable data is in csv file format. Files with x/y coordinate information use the Albers Equal Area Conic projection (ESRI:102003). 1. CERF Gridded Siting Parameters This directory provides a balanced sample of gridded CERF siting parameters data for eight different scenarios for the Western US through 2055, seven different technologies, and eight timesteps. This data serves as input to the feature analysis. It contains the following parameters. region_name - name of region (i.e., state) sited - binary value representing whether the grid cell received a siting of that technology type (1=True) rcp - binary value representing scenario resource concentration pathway (0 = RCP4.5, 1 = RCP8.5) ssp - binary value representing scenario shared socioeconomic pathway (0 = SSP3, 1 = SSP5) climate - binary value representing cooler (0) or hotter (1) GCM forcing tech_name - generation technology name sited_year - year that values correspond to transmission_cost - cost of transmission interconnection pipeline_cost - cost of natural gas pipeline interconnection interconnection_cost - total interconnection cost (sum of transmission cost and gas pipeline cost) lmp - associated locational marginal value ($/MWh) associated with the grid cell, timestep, scenario, and technology xcoord - x-coordinate of location ycoord - y-coordinate of location 2a. Feature Analysis Output The dataset includes the feature analysis shap output for locational marginal price and interconnection cost. It contains the following parameters. technology - generator technology name scenario - name of scenario feature - name of feature, either locational_marginal_price or interconnection_cost value - the mean of absolute value of SHAP values for given feature 2b. Feature Analysis Classification Report This download includes the classification report associated with each random forest model. The dataset contains the following parameters. technology - generation technology name scenario - name of scenario test - one of precision (the proportion of predicted positives that are actually correct), recall (the proportion of actual positives that were correctly identified), f1-score (the harmonic mean of precision and recall) 0.0 - value of test for classification of 0 (grid cell not chosen for siting) 1.0 - value of test for classification of 1 (grid cell chosen for siting) accuracy - accuracy of model (i.e., fraction of all predictions that were right) macro avg - Simple average of test values for all classes weighted avg - Weighted average of test values for all classes, weighted based on Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall [Pacific Northwest National Labor↗

Package Data for CERF-Data Centers

This dataset contains sample input 100m resolution raster files for running the CERF-DC python package (see https://github.com/IMMM-SFA/cerf_data_centers) at the state level across the CONUS. Due to data availability constraints, some of the items included in this dataset are proxies or assumptions for siting factors used in the model. These are individually noted in the item descriptions and can be exchanged with more detailed information upon availability. Data Descriptions The following raster files are included in the data download: state_siting_region.tif — State areas identified by state FIPS code composite_siting_suitability.tif — Value of 1 indicates suitable siting location, 0 otherwise. The following areas are excluded from siting: Areas within 300m of a federal airport runway Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory Protected Areas Database of the United States (PAD-US) areas Railroads, major roadways, and minor roadways Military areas and training grounds Developed lands Areas >0.8 km (0.5 miles) from developed lands land_value_dollar_per_sqft.tif — USD per square foot (sqft) derived from USDA $/acre land cost personal_property_tax_rate.tif — Personal property tax rate by state. Uses an assumed 0.0125 personal property tax rate for states with personal property tax, 0 for states without personal property tax. real_property_tax_rate.tif — Real property tax rate. Based on county level residential real estate property tax rates. sales_tax_rate.tif — Sales tax rate by state. mechanical_cooling_fraction.tif — Fraction of year (values between 0 and 1, inclusive) that the data center would be cooled through mechanical processes based on local water stress and humidity levels. water_cooling_fraction.tif — Fraction of year (values between 0 and 1, inclusive) that the data center would be cooled through evaporative (water cooled) processes based on local water stress and humidity levels. distance_to_substation.tif — Distance to nearest substation in hundreds of meters (i.e., value of 1 equals a distance of 100m). Offshore areas have a value of 0. industrial_electricity_rates_dollar_per_kwh.tif — USD/kWh industrial electricity rates. Represents the average industrial rate across all utilities that operate within a given county. Values are derived from the US Utility Rate Database. commercial_electricity_rates_dollar_per_kwh.tif — USD/kWh commercial electricity rates. Represents the average commercial rate across all utilities that operate within a given county. Values are derived from the US Utility Rate Database. data_center_market_locations.tif — Grid cells with positive values represent the centroid of existing data center market clusters. The value of non-zero grid cells represents the number of data centers in the market cluster. All other grid cells have a value of 0. Geospatial Metadata CRS: Albers Equal Area Conic (ESRI:102003) Extent: -2415585.0000000023283064,-1441981.2605773280374706 : 2384414.9999999976716936,1708018.7394226719625294 Dimensions: X: 48000 Y: 31500 Bands: 1 Origin: -2415585.0000000023283064,1708018.7394226719625294 Pixel Size: 100,-100 Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall↗

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway or within an airport area boundary Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory USGS Protected Areas Database of the United States (PAD-US) GAP status 1, 2, or 3 areas US National Parks Wetlands USFWS critical habitats BIA land areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)↗