Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Experimental testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Center for Momentum Transport and Flow Organization (CMTFO) (Final Technical Report)

The Center for Momentum Transport and Flow Organization (CMTFO) is a DOE Plasma Science Center formed in late 2009 to focus on the general principles underlying momentum transport in magnetic fusion and astrophysical systems. It is composed of funded researchers from UCSD, UW Madison, U. Colorado, PPPL. As of 2011, UCSD supported postdocs are collaborating at MIT/Columbia and UC Santa Cruz and beginning in 2012, will also be based at PPPL. In the initial startup period, the Center supported the construction of two basic experiments at PPPL and UW Madison to focus on accretion disk hydrodynamic instabilities and solar physics issues. We now have computational efforts underway focused on understanding recent experimental tests of dynamos, solar tacholine physics, intrinsic rotation in tokamak plasmas and L-H transition physics in tokamak devices. In addition, we have the basic experiments discussed above complemented by work on a basic linear plasma device at UCSD and a collaboration at the LAPD located at UCLA. We are also performing experiments on intrinsic rotation and L-H transition physics in the DIII-D, NSTX, C-Mod, HBT EP, HL-2A, and EAST tokamaks in the US and China, and expect to begin collaborations on K-STAR in the coming year. Center funds provide support to over 10 postdocs and graduate students each year, who work with 8 senior faculty and researchers at their respective institutions. The Center has sponsored a mini-conference at the APS DPP 2010 meeting, and co-sponsored the recent Festival de Theorie (2011) with the CEA in Cadarache, and will co-sponsor a Winter School in January 2012 in collaboration with the CMSO-UW Madison. Center researchers have published over 50 papers in the peer reviewed literature, and given over 10 talks at major international meetings. In addition, the Center co-PI, Professor Patrick Diamond, shared the 2011 Alfven Prize at the EPS meeting. Key scientific results from this startup period include initial simulations of the effects of boundary conditions on turbulent dynamo experiments; simulations of intrinsic rotation showing the strong link between toroidal rotation and temperature gradients and elucidation of the turbulence symmetry breaking mechanisms that lead to this macroscopic behavior; first experiments in a large tokamak testing the roll of turbulent momentum transport in driving intrinsic rotation; experiments in tokamaks showing strong evidence that zonal flows, together with the more widely recognized mean sheared ExB flow, act to trigger the L-H transition in tokamak devices and the first experimental measurement of collisional viscosity in an unmagnetized plasma. In the coming three year period, we will continue these efforts by a combination of basic hydrodynamic, liquid metal and plasma experiments combined with experiments on numerous tokamak devices around the world. In addition, we will use MHD, gyrofluid and gyrokinetic codes combined with theory to address the problems of interest to the Center.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A data driven control strategy for optimal and flexible operation of absorption systems; Stratégie de régulation fondée sur les données pour un fonctionnement optimal et flexible des systèmes à absorption

A novel control strategy for vapor absorption systems with experimental validation is presented. Statistical methods are used to integrate a detailed thermodynamic model and system-specific characteristics into a model based control algorithm. This allows for continuously optimized operation as well as fast response to variations in operating conditions. Autonomous controller performance was tested experimentally for response to changes in heat sink and evaporator temperatures. Continuous turndown with fast response to capacity demand changes, in contrast to suboptimal on/off control, was demonstrated. The thermal compressor concept was employed to develop the variable speed thermal compressor module, with aspects specific to absorption heat pumps, also facilitating cross-applicability of vapor compression system control strategies. Our results of this study enable further development and optimization of absorption systems for a wide range of applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tunable polyvinyl chloride (PVC) and thermoplastic polyurethane (TPU)-based soft polymer gel sensors

Abstract Polyvinyl chloride (PVC) gels have recently been found to exhibit mechanoelectrical transduction under mechanical deformation. These mechanoelectrical properties of PVC gels are largely uncharacterized and the underlying transduction mechanisms are currently unknown. These soft electroactive polymers have tunable properties such as modulus and response voltage based on physical dimensions and the amount of plasticizer content within the material making them ideal candidates for complaint sensors. This study aims to investigate PVC gels comprised of various plasticizers to further investigate underlying mechanisms of mechanoelectrical transduction and broaden possible sensing applications. Plasticizers used in this study include dibutyl adipate, dibutyl phthalate, dioctyl phthalate, otherwise known as bis(2-ethylhexyl) phthalate, diisodecyl adipate, and the environmentally friendly biodegradable plasticizer acetyl tributyl citrate (ATBC). ATBC is often used in cosmetics and food packaging applications and is even used as a food additive which may lead to future biocompatibility for these gel sensors. These plasticizers are used to produce PVC gel sensors that are experimentally tested for mechanoelectrical transduction properties and sensing performance. In this study, a Langmuir adsorptive model is fit to the collected mechanoelectrical transduction data. These results are also nondimensionalized and compared to the characteristic dimensionless Langmuir adsorptive model. This simple model agrees very well with the experimental data. Additionally, a study on the mechanoelectrical transduction of an alternative polymer lattice structure, thermoplastic polyurethane (TPU), is discussed. This is a novel electroactive polymer investigated for mechanoelectrical transduction properties. This portion of the study aims to further knowledge of underlying mechanisms of mechanoelectrical transduction as well as show feasibility of additional lattices for soft polymer gel sensors. These TPU gel sensors show strikingly similar mechanoelectrical transduction properties to analogous PVC gels, insinuating that the polymer structure has a limited role in the underlying sensing mechanism and PVC itself is not unique to polymer gel sensing. The TPU-based soft polymer gel sensors however do display some level of mechanoelectrical hysteresis which may be attributed to viscoelastic properties and display a small amount of fatigue possibly due to exudation of liquid plasticizer. This study provides further characterization of mechanoelectrical response for varying plasticizers, provides a theoretical framework for underlying mechanisms, and displays the potential for further polymeric gel sensors.

Instruments & Instrumentation↗

Study of exothermic processes in shock ignited gases by the use of laser shear interferometry.

The paper reports on the measurements of maximum exothermic power pulses attainable from a given chemical system. Experimental tests involved the use of a shock tube technique whereby the exothermic process of combustion was controlled by reflected shock so that it occurred under virtually inviscid flow conditions, the data having been obtained at a resolution commensurate with the actual rate of chemical reaction. Experimental observations were made by means of a novel method of laser shear interferometry. Chemical systems treated in this manner comprised of mixtures of stoichiometric hydrogen-oxygen with 80 and 90% argon, while the measurements covered the full permissible range of initial thermodynamic conditions.

Meyer, J. W.↗

Study of exothermic processes in shock ignited gases by the use of laser shear interferometry

Report on measurements of maximum exothermic power pulses attainable from a given chemical system. Experimental tests involved the use of a shock tube technique whereby the exothermic process of combustion was controlled by reflected shock, so that it occurred under virtually inviscid flow conditions, while the measurements were performed at a resolution commensurate with the actual rate of chemical reaction. Experimental observations were made by means of a novel method of laser shear interferometry - a cross-breed between holography and the conventional means for measuring refractive index fields, in that, on one hand, it was based on the exploitation of the phase coherence of the laser light beam, recording first a diffraction image of the wave fronts which, for the desired final result, had to be optically reconstructed, and, on the other, it yielded eventually either two-dimensional interferograms or schlieren photographs of the observed phenomena.

Meyer, J. W.↗

NASA Lewis Stirling SPRE testing and analysis with reduced number of cooler tubes

Free-piston Stirling power converters are candidates for high capacity space power applications. The Space Power Research Engine (SPRE), a free-piston Stirling engine coupled with a linear alternator, is being tested at the NASA Lewis Research Center in support of the Civil Space Technology Initiative. The SPRE is used as a test bed for evaluating converter modifications which have the potential to improve the converter performance and for validating computer code predictions. Reducing the number of cooler tubes on the SPRE has been identified as a modification with the potential to significantly improve power and efficiency. Experimental tests designed to investigate the effects of reducing the number of cooler tubes on converter power, efficiency and dynamics are described. Presented are test results from the converter operating with a reduced number of cooler tubes and comparisons between this data and both baseline test data and computer code predictions.

Wong, Wayne A.↗

Design and development of a 6 MW peak, 24 kW average power S-band klystron

A 6 MW peak, 24 kW average power S-band Klystron is under development at CEERI, Pilani under an MoU between BARC and CEERI. The design of the klystron has been completed. The electron gun has been designed using TRAK and MAGIC codes. RF cavities have been designed using HFSS and CST Microwave Studio while the complete beam wave interaction simulation has been done using MAGIC code. The thermal design of collector and RF window has been done using ANSYS code. A Gun Collector Test Module (GCTM) was developed before making actual klystron to validate gun perveance and thermal design of collector. A high voltage solid state pulsed modulator has been installed for performance valuation of the tube. The paper will cover the design aspects of the tube and experimental test results of GCTM and klystron. (author)

43 PARTICLE ACCELERATORS↗

FAST Model Calibration and Validation of the OC5-DeepCwind Floating Offshore Wind System Against Wave Tank Test Data

During the Offshore Code Comparison Collaboration, Continued, with Correlation (OC5) project, which focused on the validation of numerical methods through comparison against tank test data, the authors created a numerical FAST model of the 1:50-scale DeepCwind semisubmersible system that was tested at the Maritime Research Institute Netherlands ocean basin in 2013. The OC5 project revealed a general underprediction of loads and motions by the participating numerical models. This paper discusses several model calibration studies that were conducted to identify potential model parameter adjustments that help to improve the agreement between the numerical simulations and the experimental test data. These calibration studies cover wind-field-specific parameters (coherence, turbulence), and hydrodynamic and aerodynamic modeling approaches, as well as rotor model (blade-pitch and blade-mass imbalances) and tower model (structural tower damping coefficient) adjustments. These calibration studies were conducted based on relatively simple calibration load cases (wave only/wind only). The agreement between the final FAST model and experimental measurements is then assessed based on more complex combined wind and wave validation cases. The analysis presented in this paper does not claim to be an exhaustive parameter identification study but is aimed at describing the qualitative impact of different model parameters on the system response. This work should help to provide guidance for future systematic parameter identification and uncertainty quantification efforts.

17 WIND ENERGY↗

Scattering Solar Thermal Concentrators

This program set out to explore a scattering-based approach to concentrate sunlight with the aim of improving collector field reliability and of eliminating wind loading and gross mechanical movement through the use of a stationary collection optic. The approach is based on scattering sunlight from the focal point of a fixed collection optic into the confined modes of a sliding planar waveguide, where it is transported to stationary tubular heat transfer elements located at the edges. Optical design for the first stage of solar concentration, which entails focusing sunlight within a plane over a wide range of incidence angles (>120 degree full field of view) at fixed tilt, led to the development of a new, folded-path collection optic that dramatically out-performs the current state-of-the-art in scattering concentration. Rigorous optical simulation and experimental testing of this collection optic have validated its performance. In the course of this work, we also identified an opportunity for concentrating photovoltaics involving the use of high efficiency microcells made in collaboration with partners at the University of Illinois. This opportunity exploited the same collection optic design as used for the scattering solar thermal concentrator and was therefore pursued in parallel. This system was experimentally demonstrated to achieve >200x optical concentration with >70% optical efficiency over a full day by tracking with <1 cm of lateral movement at fixed latitude tilt. The entire scattering concentrator waveguide optical system has been simulated, tested, and assembled at small scale to verify ray tracing models. These models were subsequently used to predict the full system optical performance at larger, deployment scale ranging up to >1 meter aperture width. Simulations at an aperture widths less than approximately 0.5 m with geometric gains ~100x predict an overall optical efficiency in the range 60-70% for angles up to 50 degrees from normal. However, the concentrator optical efficiency was found to decrease significantly with increasing aperture width beyond 0.5 m due to parasitic waveguide out-coupling loss and low-level absorption that become dominant at larger scale. A heat transfer model was subsequently implemented to predict collector fluid heat gain and outlet temperature as a function of flow rate using the optical model as a flux input. It was found that the aperture width size limitation imposed by the optical efficiency characteristics of the waveguide limits the absolute optical power delivered to the heat transfer element per unit length. As compared to state-of-the-art parabolic trough CPV system aperture widths approaching 5 m, this limitation leads to an approximate factor of order of magnitude increase in heat transfer tube length to achieve the same heat transfer fluid outlet temperature. The conclusion of this work is that scattering solar thermal concentration cannot be implemented at the scale and efficiency required to compete with the performance of current parabolic trough CSP systems. Applied within the alternate context of CPV, however, the results of this work have likely opened up a transformative new path that enables quasi-static, high efficiency CPV to be implemented on rooftops in the form factor of traditional fixed-panel photovoltaics.

14 SOLAR ENERGY↗

Experimental demonstration of real-time electron temperature profile control in DIII-D

Future tokamak reactor operation will require the ability to maintain a given plasma scenario for extended periods of time. This will necessitate the capability to react to changes in the plasma state and return the plasma to the target scenario; the principal method to achieve this is through feedback control. Thus, it is necessary to develop and test feedback controllers for the plasma profiles that define a target scenario. In this work, a feedback controller for the electron temperature (Te) profile is tested experimentally in DIII-D. This experiment relied on the ability to ascertain the electron temperature profile in real time, which was achieved using an observer algorithm. The observer relies on both diagnostic data and a predictive model of the electron temperature profile evolution; this predictive model includes contributions from neural network surrogate models. Because of these dependencies, a number of capabilities needed to be added to the real-time PCS for DIII-D in order to support the Te profile control experiment. The neural network surrogates needed to be integrated into the PCS to be called in real time. An observer algorithm for the Te profile needed to be added and connected to the Thomson scattering system to allow access to the current state of the profile in real time. When tested, the observer was shown to produce Te profiles that are consistent with the shape of the Thomson scattering data while rejecting much of the noise in the diagnostic data. Finally, the controller itself was tested in real time. This experiment showed that the controller is capable of tracking the electron temperature target at locations across the spatial profile.

Morosohk, Shira [Oak Ridge Associated Universities↗

Testing relativistic theories of gravity with spacecraft-Doppler gravity-wave detection

The response of a spacecraft Doppler-tracking system to the passage of a weak plane gravity wave of the most general polarization is calculated. Results show that the simultaneous tracking of several spacecraft could provide an unambiguous determination of the gravity-wave polarization, a much needed result in the continuing experimental testing of relativistic theories of gravity.

Hellings, R. W.↗

Deep Space Test Bed

The DSTB Facility provides a new capability for the National Aeronautics and Space Administration s (NASA s) Space Radiation Shielding Project (SRSP). The objective of the DSTB is to provide a platform to conduct radiation shielding investigations in an environment more similar to deep space than most Low Earth orbits or is achievable at a particle accelerator. The DSTB provides a means to experimentally test radiation shielding effectiveness of various materials and to test the accuracy of radiation transport code predictions in the deep space cosmic ray environment more frequently and at a lower cost compared to space flight missions. New spectrometers, dosimeters and other techniques may be exercised and verified using the DSTB before space flight. The DSTB will be implemented through NASA s National Scientific Balloon Facility (NSBF) which provides polar balloon flights that lift science payloads to high altitude (120,000 A. (36.58km)) to escape much of the shielding effects of the Earth s atmosphere and magnetosphere. Polar flights are conducted through NSBF in coordination with the United States Polar Program. The DSTB will be launched on a Long Duration Balloon (LDB) from McMurdo, Antarctica (77.86 degrees south latitude) for circumpolar flights, nominally 20 days, traveling to the west and typically bounded between 73 to 82 degrees south latitude. Float altitudes for these balloons with payload are 115,000 to 130,000 feet (35.05 to 39.62km). The DSTB will be able to accommodate up to 20 investigations per flight. Annual flight opportunities are planned starting in December 2005. Balloon campaigns in Antarctica occur in December and January during the Austral summer. Since a key goal of the DSTB facility is to efficiently serve the varied needs of the radiation shielding community; it must be designed with a flexible architecture. By implementing the DSTB facility with NASA s balloon program, which operates under reduced formalities compared to space flight, the DSTB facility can adjust for different investigation priorities on successive flights. This flexibility in the DSTB will be applied at several levels; in the distribution of the shared resources for each flight; addressing the payload configuration on a system level for each flight; and utilizing a selection process for investigations that considers yearly flight opportunities as well as the possibility for repeated flights. This approach for operating the DSTB facility will allow it to handle a wide range of investigations.

Milton, Martha E.↗

Active Damping of the E-P Instability at the LANL PSR

A prototype of an analog, transverse (vertical) feedback system for active damping of the two-stream (e-p) instability has been developed and successfully tested at the Los Alamos National Laboratory Proton Storage Ring (PSR). This system was able to improve the instability threshold by approximately 30% (as measured by the change in RF buncher voltage at instability threshold). Evidence obtained from these tests suggests that further improvement in performance is limited by beam leakage into the gap at lower RF buncher voltage and the onset of instability in the horizontal plane, which had no feedback. Here we describe the present system configuration, system optimization, results of several recent experimental tests, and results from studies of factors limiting its performance.

43 PARTICLE ACCELERATORS↗

Final Report – Cooperative Research and Development Agreement between National Energy Technology Laboratory and Oxergy, Inc.

The NETL Raman Gas Analyzer (RGA) has been demonstrated to have an extremely fast response (<1 second) multi-gas analysis capability. All but the noble gases are Raman active, although the Raman interaction is weak. The RGA uses a reflectively lined capillary as the optical cell, providing both a small sample volume for fast gas exchange, and a much greater Raman signal collection than traditional instrument configurations. This allows very fast measurement of fuel gases (hydrogen, methane, ethane, propane) as well as other common industrial gases (carbon monoxide, carbon dioxide, nitrogen, oxygen, and water). This provides a new enabling technology for faster, smarter process control based on the chemical composition of the gases in the process – including improved fuel flexibility and efficiency for power generation systems. Research and development up to 2016 resulted in the construction of two field prototypes of the NETL RGA, which has been in applied to various laboratory applications for testing. The results of the testing have been used to improve the RGA design, with the intent to support technology transfer. The quality of the optical capillary used in the RGA is critical to its performance, and prior work at NETL produced a few optical capillaries superior to those commercially available. The production of high optical quality capillaries, however, was inconsistent in its results. With the support of the DOE Office of Technology Transitions, through the Technology Commercialization Fund program, this project was undertaken to address this commercialization barrier and to also evaluate the possible application of Raman gas analysis to a supercritical water gasification process being developed by Oxergy Inc. Oxergy, a small business located in Fairbanks, Alaska, is developing ultra-compact thermochemical reaction devices built with advanced manufacturing processes. Chief Technology Officer Jonathan Kamler holds the (pending) patent to Oxergy’s core reactor technology. Oxergy maintains wet-lab and combustion-lab space at the University of Alaska Fairbanks Center for Sustainable Living in Palmer, Alaska, where Mr. Kamler operates a pilot-scale, supercritical water gasification system designed and built by Oxergy. Mr. Kamler also operates an All Powers Labs Power Pallet gasifier coupled to a 10KW electrical generator as a dry biomass test platform at the Palmer facility. Both systems are suitable for real-world, collaborative testing of Raman gas analysis applications. The objectives of the CRADA include making the production of high-quality optical capillaries consistent and high yield, investigating other options for optical waveguides, and testing the capillaries for measurements in supercritical water gasification. Success on these objectives will support commercialization of both the RGA and supercritical water gasification technologies. Through the work performed on this project, a new apparatus was constructed and optimized to provide consistent production of high-quality optical capillaries. Several thick-walled capillaries were coated using this apparatus and shipped to Oxergy in September 2018 for testing in both dry gasification and supercritical water gasification process monitoring applications at University of Alaska Fairbanks facilities in Palmer. The strong earthquake near Anchorage and Palmer in November 2018 caused extensive damage and closure of the facilities used by Oxergy, preventing Oxergy from proceeding with experimental testing before the end of the project; the facility has been closed indefinitely. Earthquake damage prohibited the completion of all the project objectives prior to the end of the project. However, significant progress was made toward addressing a core technology commercialization barrier. The largest and most mature potential market for Raman gas analysis is its use in analytical instruments, which require sensitivity and low detection limits, and Oxergy’s market research found that market inertia is a barrier to commercial success in this market. Although NETL’s innovations in capillary coating have substantially improved Raman gas analysis capability, the likely market is expected to be niche applications that value the fast detection of real-time changes in gas composition.

Chorpening, Benjamin↗

FY19 Report for Instrumentation Development for the Transient Testing Program

This report details the technical activities and accomplishment carried out under funding from the Department of Energy (DOE) Nuclear Technology Research and Development (NTRD) program for in-pile instrumentation supporting the transient testing program in FY19. These activities were performed in support of cross-cutting transient testing experiment objectives. The purpose of this report is to provide a summary of key technical work, of particular interest to nuclear irradiation test experimenters and in-pile instrumentation engineers. During FY19, development activities are focused on deployment of devices to perform online measurement of neutron flux, temperature, and mechanical behaviors in nuclear fuels experiments. Specifically, these R&D activities include in-pile investigations at the Transient Reactor Test (TREAT) facility throughout the year. Other in-pile instrumentation R&D activities are being carried out under other DOE programs, which may be recognized but not the focus of this document. A brief summary of activities and accomplishments is first provided for each major activity. More detailed summaries are presented in appendices.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Low Energy Photon Filter Box Optimization Study for the Gamma Irradiation Facility (GIF)

As a follow-up to results presented at the 16th International Symposium on Reactor Dosimetry, a new set of low energy photon filter box designs were evaluated for potential testing at the Gamma Irradiation Facility in Sandia National Laboratories' Technical Area V. The goal of this filter box design study is to produce the highest fidelity gamma ray test environment for electronic parts. Using Monte Carlo coupled photon/electron transport, approximately a dozen different designs were evaluated for the effectiveness in reducing the dose enhancement in a silicon sensor. The completion of this study provides the Radiation Metrology Laboratory staff with a starting point for experimental test plans that could lead to improvement in the gamma ray test environment at the Gamma Irradiation Facility.

61 RADIATION PROTECTION AND DOSIMETRY↗

Compressive Testing of Stitched Frame and Stringer Alternate Configurations

A series of single-frame and single-stringer compression tests were conducted at NASA Langley Research Center on specimens harvested from a large panel built using the Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) concept. Different frame and stringer designs were used in fabrication of the PRSEUS panel. In this report, the details of the experimental testing of single-frame and single-stringer compression specimens are presented, as well as discussions on the performance of the various structural configurations included in the panel.

Leone, Frank A., Jr.↗

Thermal-Hydraulic Performance of a Zeotropic Refrigerant in a Brazed Plate Evaporator

In this work we report the results of a preliminary investigation focused on evaluating the thermal-hydraulic performance of R455A (CO2, R32, R1234yf – 3/21.5/75.5) in a commercial brazed plate heat exchanger. Three key parameters were measured which were refrigerant flow maldistribution, overall refrigerant side heat transfer coefficient, and total refrigerant side pressure drop. These same parameters were also measured for R134a which served as a base-line refrigerant for comparison. The experimental test matrix was set up to investigate the influence of refrigerant mass flux (3 ≤ Gref ≤ 5 kg m-2 s-1), refrigerant inlet vapor quality (0.1 ≤ xin ≤ 0.4), and refrigerant exit superheat (5 ≤ Tsh ≤ 10 K) on the above mentioned thermal-hydraulic parameters. For these experimental conditions, on average, the overall refrigerant side heat transfer coefficients for R455A were 45.2% lower than those of R134a. Refrigerant flow maldistribution for R455A, on average, was observed to be 62.6 % higher than that measured for R134a, and the total pressure drop across the heat exchanger (minor and frictional losses) for R455A was on average 26.5% higher than that measured for R134a. These initial results set the stage for a comprehensive investigation focused on further investigating the thermal-hydraulic performance of zeotropic refrigerants in brazed plate heat exchangers.

Jajja, Saad [ORNL]↗