Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Event planning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Stellar Occultation Observations to Constrain the Stratosphere of Uranus for Aerocapture

Background on Uranus: Voyager 2 (V2) UV stellar and solar occultations at Uranus detected a warm stratosphere and extremely hot thermosphere [1, 2], far in excess of solar irradiance [3, 4] and internal heating [5, 6]. New theories to explain similar heating at Jupiter [7] and Saturn [8] cannot be tested at Uranus due to a dearth of reliable measurements. In [9, 10], we reprocessed 26 archival Earth-based stellar occultations by Uranus (1977-1996), finding stratospheric temperatures (~200 K) warmer than the original (~100 K), but in stark tension with V2 (~300-500 K). In [10], we built a physics-based, 1-D atmospheric model (see Fig 1) that finds a nearly isothermal stratosphere and a dynamic heat sink in the lower thermosphere. Aerocapture: Aerocapture is spacecraft maneuver that uses a single deep dip to enter orbit. It could decrease cruise time and launch mass for a Uranus mission, but the greatest impediment is uncertain stratospheric densities of Uranus [11]. Aims: 1) Observe and process many high S/N Uranus stellar occultations in the next decade; 2) constrain stratospheric densities for aerocapture; 3) better understand the energy balance; 4) determine stratospheric changes since 1996. Upcoming Occultations: We will present our observing plan for the 2025 April Uranus occultation (K mag 8) and discuss the best-in-a-century 2031 event (K mag 4). We will discuss other events in the early 2030s [12] [13], predicted constraints on density, and simulations of aerocapture for UOP. We will discuss the Shadow Chaser, a small satellite concept for observing occultations from Earth orbit [12]. Conclusions: New stellar occultations can vastly improve profiles of the stratosphere of Uranus; this is critical for understanding energy circulation and constraining densities for using aerocapture on UOP. References: [1] Herbert, F. et al. (1987). JGR. [2] Stevens, M. et al. (1993). Icarus. [3] Marley, M. & McKay, C. (1999). Icarus, [4] Li, C. et al. (2018). JQRST. [5] Pearl, J. et al. (1990). Icarus. [6] Melin, H (2020). Nat Astron. [7] O’Donoghue, J. et al. (2021) Nature. [8] Mueller-Wodarg, I. et al. (2019) GRL. [9] Saunders, W. et al. (2023). PSJ. [10] Saunders, W. et al. (2024). PSJ. [11] Report of the Aerocapture Demonstration Relevance Assessment Team (2023). [12] Saunders, W. et al. (2022). P&SS. [13] French, R. & Souami, D. (2023) PSJ.

William Saunders↗

Defect Length and Profile Influence on Frequency Domain Reflectometry

Degradation of the cable jacket, electrical insulation, and other cable components of installed cables within nuclear power plants (NPPs) is known to occur as a function of age, temperature, radiation, and other environmental factors. Although system tests verify cable function under normal loads, demonstration of some cable’s ability to perform under exceptional loads associated with design-basis events is essential to assuring plant integrity. The cable’s ability to perform safely over the initial 40 year planned and licensed life has generally been demonstrated and there have been very few age-related cable failures. With greater than 1000 km of power, control, instrumentation, and other cables typically found in an NPP, replacing all the cables would be a severe cost burden. Justification for life extension to 60 and 80 years requires a cable aging management program that includes condition monitoring to justify cable performance under normal operation as well as accident conditions. A variety of tests are available to assess various aspects of electrical and mechanical cable performance, but none are suitable for all cable configurations nor does any single test confirm all features of interest. One particularly promising test that is beginning to be used more and more by utilities is frequency domain reflectometry (FDR). FDR is a nondestructive electrical inspection technique used to detect and localize faults in power and communication system conductors along the length of a cable from a single connection point. FDR detects discontinuities in the electrical impedance that arise due to cable splices or similar changes along the path of the conductor pair. In addition, FDR has the potential to provide sensitivity to insulation degradation by detecting small changes in impedance between the cable conductors being examined. The technique is also sensitive to cable bends, the particular lay of the cable in tray, proximity to other cable, and other factors that bear consideration when interpreting the test results. This paper examines various influences on the FDR approach particularly using FEM modeling methods and focusing on defect length and defect profile.

Cable Inspection, Frequency Domain Reflectometry, ↗

Designing the PR100 Study: Puerto Rico Grid Resilience and Transition to 100% Renewable Energy

Puerto Rico has committed to meeting its electricity needs with 100% renewable energy by 2050, along with realizing interim goals of 40% by 2025, 60% by 2040, the phaseout of coal-fired generation by 2028, and a 30% improvement in energy efficiency by 2040 as established in Act 17. [1] To meet these goals and support widespread end-use electrification, the territory must explore how renewable energy and other generation technologies can be developed with energy storage, distributed generation, distribution control, electric vehicles, and energy efficient and responsive loads in each of Puerto Rico's cities and communities. To support Puerto Rico in reaching its renewable energy goals; help ensure energy system resilience against future extreme weather events; improve energy justice; and provide inputs to LUMA Energy's walk, jog, and run approach in its coordinated planning roadmap, the U.S. Department of Energy, National Renewable Energy Laboratory, Argonne National Laboratory, Lawrence Berkeley National Laboratory, Oak Ridge National Laboratory, Pacific Northwest National Laboratory and Sandia National Laboratories propose to evaluate 100% renewable energy pathways through an integrated analysis process. This talk will present steps in designing a two-year study entitled Puerto Rico Grid Resilience and Transitions to 100% Renewable Energy (PR100). [1] U.S. Energy Information Administration (EIA). 2020. Puerto Rico Territory Energy Profile.

100% renewable energy↗

Electric actuator modification on a turbine driven feed pump at Calvert Cliffs nuclear power plant - 296

Feedwater systems are a leading contributor to unit SCRAMs as indicated by the 2015 INPO data, where 9 of the 51 SCRAMs recorded were a result of feedwater issues. Digital feedwater control systems and enhanced feed pump control modifications can greatly improve performance and control of the plant feedwater systems and help drive down the potential for reactivity management events and unit SCRAMs. Westinghouse has a strong background in the implementation of digital feedwater control systems, and in planning for a recently completed feedwater control system upgrade at Calvert Cliffs, the Westinghouse team worked with Calvert Cliffs to design a solution to a number of common operational issues. Primarily, improving feedwater control over the entire operating range, eliminating single points of vulnerability (SPV) in the feedwater/feed pump systems and eliminating operational issues with the feed pump steam admission valve hydraulic control oil system. A robust first-of-a-kind design and implementation program was undertaken to split the existing hydraulic valve gear actuator with separate electric actuators. Westinghouse worked with Calvert Cliffs and Emerson Process Management (EPM) to install and commission General Electric (GE) feed pump turbines with separate electric actuators for the high-pressure (HP) and low-pressure (LP) steam admission valves. This successful mechanical and control modification was a first for both the nuclear and non-nuclear power generation industries. Westinghouse is working with a number of other utilities to implement similar modifications for PWR and BWR feed pump applications. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Balloon-Occluded Transcatheter Arterial Chemoembolization (b-TACE) for Hepatocellular Carcinoma Performed with Polyethylene-Glycol Epirubicin-Loaded Drug-Eluting Embolics: Safety and Preliminary Results

Purpose: To report technical success, safety profile and oncological results of balloon-occluded transcatheter arterial chemoembolization using a balloon micro-catheter and epirubicin-loaded polyethylene-glycol (PEG) microsphere (100 ± 25 µm and 200 ± 50 µm) in patients with hepatocellular carcinoma (HCC). Materials and Methods: This is a single-centre, single-arm, retrospective study with 6-month follow-up. Twenty-two patients (Child–Pugh A 68% [15/22], B in 32% [7/22]; age 67.05 ± 14 years) with 29 HCC were treated in 24 procedures. Technical success is defined: ability to place the balloon micro-catheter within the required vascular segment, balloon-occluded arterial stump pressure drops and assessment of microsphere deposition. Laboratory assessment pre/post-procedural and complications were analysed, respectively, according to Common Terminology Criteria for Adverse Events (CTCAEv5) and CIRSE system. Postembolization syndrome (PES) was defined as fever and/or nausea and/or pain onset. Oncological results were evaluated using m-RECIST criteria with CT/MRI imaging at 1 and 3–6 months. In partial responder patients, pre/post-procedural tumour volume was compared. Results: Pre-planned feeder was reached in all cases. Pressure drop average was 51.1 ± 21.6 mmHg. Exclusive target embolization was achieved in 14/24 procedures (58.3%). Laboratory test modifications were all grade 1. 4/24 adverse events occurred (17%): pseudo-aneurysm of the feeder (grade 3), liver abscess (grade 2) and 2 asymptomatic segmentary biliary tree dilatations (grade 2). PES occurred in 8/24 (33%). The complete response at 1 and 3–6 months was 44.8% (13/29) and 52.9% (9/17), respectively. The partial response at 1 and 3–6 months was 55% (16/29) and 4/17 (23.5%), respectively. Among partial responder patients, the average percentage of tumour volume reduction was 64.9 ± 27.3%. Conclusion: Epirubicin-loaded PEG microsphere b-TACE is technically feasible, safe and effective procedure for HCC treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Y-12 Nuclear Criticality Safety Program Health Model: Development, Use and Benefits

The Y-12 National Security Complex (Y-12) operates seven diverse enriched uranium processing facilities and maintains a comprehensive nuclear criticality safety (NCS) program. Given the magnitude of the hazard, the NCS program receives significant oversight. Describing the scope and health of the Y-12 NCS program to sometimes non-expert stakeholders with limited time had historically focused on recent events and “hot topics” which did not always convey sufficient context (i.e., how to differentiate between an individual performance issue and a systemic concern). Y-12 created the NCS Program Health (NCSPH) Model to provide a complete and holistic framework to quantify and communicate NCS program health. The model is constructed in a tiered fashion with the top tier broken into three (3) Tier 2 elements, fourteen (14) Tier 3 elements, and 104 Tier 4 and 5 elements. This granularity ensures every feature of the NCS Program is accounted for and stakeholders can see how these features support the collective whole. The model is used as the framework for NCS communications including program plans, reports, health surveys, and meeting agendas. The model has substantially improved stakeholder appreciation for the entirety of the NCS program and how events and assessment results factor into an overarching conclusion on NCS program health. While some details are Y-12 specific, the NCSPH model can easily be tailored for any other site with an NCS program.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Technical Resilience Navigator: Risk-Informed Decision Making to Support Resilience Planning

The Technical Resilience Navigator (TRN) helps organizations manage the risk to critical functions at a site from disruptions in energy and water services. Developed in partnership by the Pacific Northwest National Laboratory and the National Renewable Energy Laboratory, under direction and funding from the Department of Energy’s Federal Energy Management Program, the TRN helps organizations enhance their resilience to a variety of disruptive events, both natural and human-caused, that could interrupt normal operations for an unknown period of time. This report provides an overview of the TRN’s risk-informed approach to resilience planning and formally describes how it uses a streamlined risk model to identify effective strategies for improving resilience.

99 GENERAL AND MISCELLANEOUS↗

Conjunction Assessment Screening Volume Sizing and Event Filtering in Light of Natural Conjunction Event Development Behaviors

Conjunction Assessment screening volumes used in the protection of NASA satellites are constructed as geometric volumes about these satellites, of a size expected to capture a certain percentage of the serious conjunction events by a certain time before closest approach. However, the analyses that established these sizes were grounded on covariance-based projections rather than empirical screening results, did not tailor the volume sizes to ensure operational actionability of those results, and did not consider the adjunct ability to produce data that could provide prevenient assistance for maneuver planning. The present study effort seeks to reconsider these questions based on a six-month dataset of empirical screening results using an extremely large screening volume. The results, pursued here for a highly-populated orbit regime near 700 km altitude, identify theoretical limits of screening volume performance, explore volume configuration to facilitate both maneuver remediation planning as well as basic asset protection, and recommend sizing principles that maximize volume performance while minimizing the capture of "chaff" conjunctions that are unlikely ever to become serious events.

screening volume↗

Geothermal Drilling: A Baseline Study of Nonproductive Time Related to Lost Circulation

A single production geothermal well costs up to seven million dollars and a typical geothermal field contains 10 to 20 wells for a development cost of potentially $140 million according to a Geothermal Resources Group study. Capital cost coupled with exploration and resource uncertainty lead to high upfront project risk. This study analyzed the time and cost of detailed geothermal drilling operations. We found the largest cause of nonproductive time in geothermal wells is advancing through lost circulation zones, where drilling fluid is lost from the well. Mitigation measures implemented during lost circulation events can increase drilling time by a significant fraction of the drilling days. There is opportunity to reduce the drilling costs by addressing logistical inefficiencies and ineffective mitigation measures to minimize nonproductive time. This study reviewed daily drilling data for 38 geothermal wells drilled since 2009 in the U.S. The analysis presented here summarizes the lost circulation events identified in the available drilling data by assessing time per event, costs incurred, materials used, success of mitigation strategies, and resolution time. This study found that wells averaged over 100 hours of unprogrammed nonproductive time due to lost circulation, adding an estimated $185,000 to each well in rig costs. A plan for future research aimed at reducing lost circulation nonproductive time and cost is presented. operations. We found the largest cause of nonproductive time in geothermal wells is advancing through lost circulation zones, where drilling fluid is lost from the well. Mitigation measures implemented during lost circulation events can increase drilling time by a significant fraction of the drilling days. There is opportunity to reduce the drilling costs by addressing logistical inefficiencies and ineffective mitigation measures to minimize nonproductive time. This study reviewed daily drilling data for 38 geothermal wells drilled since 2009 in the U.S. The analysis presented here summarizes the lost circulation events identified in the available drilling data by assessing time per event, costs incurred, materials used, success of mitigation strategies, and resolution time. This study found that wells averaged over 100 hours of unprogrammed nonproductive time due to lost circulation, adding an estimated $185,000 to each well in rig costs. A plan for future research aimed at reducing lost circulation nonproductive time and cost is presented.

15 GEOTHERMAL ENERGY↗

Summer Series 2012 - Shashi Buluswar

The last installment of the Summer Series of Conversations took place Wednesday, August 1, with guest Shashi Buluswar, the executive director of the LBNL Institute for Globally Transformative Technologies (LIGTT). The Institute seeks to foster the discovery, development and deployment of a generation of low-carbon, affordable technologies that will advance sustainable methods to fight global poverty. The event, was hosted by Public Affairs Head Jeff Miller.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Postclosure Criticality Consequence Analysis - Scoping Phase

Commercial generation of energy via nuclear power plants in the United States (U.S.) has generated thousands of metric tons of spent nuclear fuel (SNF), the disposal of which is the responsibility of the U.S. Department of Energy (DOE) (Nuclear Waste Policy Act of 1982). Any repository licensed to dispose of the SNF must meet requirements regarding the long-term performance of the repository. In evaluating the long-term performance of the repository, one of the events that may need to be considered is the SNF achieving a critical configuration. Of particular interest is the potential behavior of SNF in dual-purpose canisters (DPCs), which are currently being used to store the SNF but were not designed for permanent disposal. As part of a multiyear plan that is currently being developed for the DOE, a two-phase study has been initiated to examine the potential consequences, with respect to long-term repository performance, of criticality events that might occur during the postclosure period in a hypothetical repository containing DPCs. Phase I, a scoping phase, consists of generating an approach intended to be a starting point for the development of the modeling tools and techniques that may eventually be required either to exclude criticality from or include criticality in a performance assessment (PA) as appropriate. The Phase I approach will be used to guide the analyses and simulations done in Phase II to further the development of these modeling tools and techniques as well as the overall knowledge base. The purpose of this report is to document the approach created during Phase I. The study discussed herein focuses on the consequences of criticality in a DPC; it does not address the probability of occurrence of a criticality event. This approach examines two types of criticality events for SNF disposed of in a single type of DPC: a steady-state criticality and a transient criticality. The steady-state critical event is characterized by a relatively low constant power output over 10,000 years, while the transient critical event is characterized by a power spike that lasts on the order of seconds. Possible effects of the criticality are an increase in the radionuclide inventory; an increase in temperature; and a change in the chemistry inside the waste package, along with a change in radionuclide solubilities, fuel degradation rates, and steel corrosion rates. Additionally, for transient criticality the possibility of mechanical damage to the engineered and natural barriers also exists.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Data for Resilience and Reliability [Slides]

The Energy to Communities (E2C) peer-learning cohort program provides technical assistance to groups of 15 community entities around a common energy topic over the course of 6 months. Every month, participants join a virtual meeting where they hear from experts and exchange strategies and best practices with their peers. This cohort, "Planning for Major Energy Disruptions in the Southeast" focuses on strategies for entities in the Southeast to quickly recover from impacts to energy infrastructure caused by extreme events, such as severe weather and natural disasters. This presentation focuses on the data available related to energy disruptions. The workshop is on April 23, 2026.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Planning green infrastructure placement based on projected precipitation data

Continued urbanization has led to tremendous changes on the landscape. These changes have exacerbated the effects of extreme climatic events such as flooding because of constrained water infiltration and increased surface flow. Typical runoff control measures involve sophisticated gray infrastructure that guide excess surface flow into storage and disposal sites. In a dynamic climate system, these measures are not sustainable since they cannot be easily modified to accommodate large volumes of runoff. Green Infrastructure (GI) is an adaptable technique that can be used to minimize runoff, in addition to offering an array of additional benefits (urban heat regulation, aesthetics, improved air quality etc.). Strategic placement of GI is key to achieving maximum utility. While physical site characteristics play a major role in determining suitable GI placement sites, knowledge of future precipitation patterns is crucial to ensure successful flood mitigation. Here, suitable GI sites within the city of Knoxville, Tennessee, were determined based on potential impact of an extreme flood event as indicated by site characteristics. Then, the relative potential likelihood of a flood event was determined based on projected precipitation data and knowledge of existing flood zones. By combining potential impact with likelihood information, low, medium, and high priority GI implementation sites were established. Results indicate that high priority sites are in the central parts of the city with priority decreasing outward. The GI prioritization scheme presented here, offers valuable guidance to city planners and policy makers who wish to exploit the GI approach for flood mitigation.

54 ENVIRONMENTAL SCIENCES↗

Approximation algorithms for planning and control

A control system operating in a complex environment will encounter a variety of different situations, with varying amounts of time available to respond to critical events. Ideally, such a control system will do the best possible with the time available. In other words, its responses should approximate those that would result from having unlimited time for computation, where the degree of the approximation depends on the amount of time it actually has. There exist approximation algorithms for a wide variety of problems. Unfortunately, the solution to any reasonably complex control problem will require solving several computationally intensive problems. Algorithms for successive approximation are a subclass of the class of anytime algorithms, algorithms that return answers for any amount of computation time, where the answers improve as more time is allotted. An architecture is described for allocating computation time to a set of anytime algorithms, based on expectations regarding the value of the answers they return. The architecture described is quite general, producing optimal schedules for a set of algorithms under widely varying conditions.

Boddy, Mark↗

Computed Tomography–Guided Interstitial High-Dose-Rate Brachytherapy in Combination With Regional Positive Lymph Node Intensity-Modulated Radiation Therapy in Locally Advanced Peripheral Non–Small Cell Lung Cancer: A Phase 1 Clinical Trial

Purpose: To assess the technical safety, adverse events, and efficacy of computed tomography (CT)-guided interstitial high-dose-rate (HDR) brachytherapy in combination with regional positive lymph node intensity modulated radiation therapy in patients with locally advanced peripheral non–small cell lung cancer (NSCLC). Methods and Materials: Twenty-six patients with histologically confirmed NSCLC were enrolled in a prospective, officially approved phase 1 trial. Primary tumors were treated with HDR brachytherapy. A single 30-Gy dose was delivered to the 90% isodose line of the gross lung tumor volume. A total dose of at least 70 Gy was administered to the 95% isodose line of the planning target volume of malignant lymph nodes using 6-MV X-rays. The patients received concurrent or sequential chemotherapy. We assessed treatment efficacy, adverse events, and radiation toxicity. Results: The median follow-up time was 28 months (range, 7-44 months). There were 3 cases of mild pneumothorax but no cases of hemothorax, dyspnea, or pyothorax after the procedure. Grade 3 or 4 acute hematologic toxicity was observed in 5 patients. During follow-up, mild fibrosis around the puncture point was observed on the CT scans of 2 patients, but both patients were asymptomatic. The overall response rates (complete and partial) for the primary mass and positive lymph nodes were 100% and 92.3%, respectively. The 1-year and 2-year overall survival (OS) rates were 90.9% and 67%, respectively, with a median OS of 22.5 months. Conclusion: Our findings suggest that HDR brachytherapy is safe and feasible for peripheral locally advanced NSCLC, justifying a phase 2 clinical trial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Probalistic Assessment of Radiation Risk for Solar Particle Events

For long duration missions outside of the protection of the Earth's magnetic field, exposure to solar particle events (SPEs) is a major safety concern for crew members during extra-vehicular activities (EVAs) on the lunar surface or Earth-to-moon or Earth-to-Mars transit. The large majority (~90%) of SPEs have small or no health consequences because the doses are low and the particles do not penetrate to organ depths. However, there is an operational challenge to respond to events of unknown size and duration. We have developed a probabilistic approach to SPE risk assessment in support of mission design and operational planning. Using the historical database of proton measurements during the past 5 solar cycles, the functional form of hazard function of SPE occurrence per cycle was found for nonhomogeneous Poisson model. A typical hazard function was defined as a function of time within a non-specific future solar cycle of 4000 days duration. Distributions of particle fluences for a specified mission period were simulated ranging from its 5th to 95th percentile. Organ doses from large SPEs were assessed using NASA's Baryon transport model, BRYNTRN. The SPE risk was analyzed with the organ dose distribution for the given particle fluences during a mission period. In addition to the total particle fluences of SPEs, the detailed energy spectra of protons, especially at high energy levels, were recognized as extremely important for assessing the cancer risk associated with energetic particles for large events. The probability of exceeding the NASA 30-day limit of blood forming organ (BFO) dose inside a typical spacecraft was calculated for various SPE sizes. This probabilistic approach to SPE protection will be combined with a probabilistic approach to the radiobiological factors that contribute to the uncertainties in projecting cancer risks in future work.

Kim, Myung-Hee Y.↗

High-Dose-Rate Monotherapy: Safe and Effective Brachytherapy for Patients With Localized Prostate Cancer

Purpose: High-dose-rate (HDR) brachytherapy used as the only treatment (monotherapy) for early prostate cancer is consistent with current concepts in prostate radiobiology, and the dose is reliably delivered in a prospectively defined anatomic distribution that meets all the requirements for safe and effective therapy. We report the disease control and toxicity of HDR monotherapy from California Endocurietherapy (CET) and William Beaumont Hospital (WBH) in low- and intermediate-risk prostate cancer patients. Methods and Materials: There were 298 patients with localized prostate cancer treated with HDR monotherapy between 1996 and 2005. Two biologically equivalent hypofractionation protocols were used. At CET the dose was 42 Gy in six fractions (two implantations 1 week apart) delivered to a computed tomography-defined planning treatment volume. At WBH the dose was 38 Gy in four fractions (one implantation) based on intraoperative transrectal ultrasound real-time treatment planning. The bladder, urethral, and rectal dose constraints were similar. Toxicity was scored with the National Cancer Institute Common Toxicity Criteria for Adverse Events version 3. Results: The median follow-up time was 5.2 years. The median age of the patients was 63 years, and the median value of the pretreatment prostate-specific antigen was 6.0 ng/mL. The 8-year results were 99% local control, 97% biochemical control (nadir +2), 99% distant metastasis-free survival, 99% cause-specific survival, and 95% overall survival. Toxicity was scored per event, meaning that an individual patient with more than one symptom was represented repeatedly in the morbidity data table. Genitourinary toxicity consisted of 10% transient Grade 2 urinary frequency or urgency and 3% Grade 3 episode of urinary retention. Gastrointestinal toxicity was <1%. Conclusions: High disease control rates and low morbidity demonstrate that HDR monotherapy is safe and effective for patients with localized prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Exploring the Complexities of Drug Formulation Selection, Storage, and Shelf-Life for Exploration Spaceflight

Medications have been a part of space travel dating back as far as the Apollo missions. Currently, medical kits aboard the ISS contain medications and supplies to help crew members cope with a variety of possible medical events. NASA reported that 1,867 medical events occurred from 1981 to 1998 on space shuttle flights, STS-1 to STS-89; 498 out of the 508 crewmembers on those flights reported experiencing a medical event other than space motion sickness. In 2000, the Institute of Medicine (IOM) convened a committee of experts, Committee on Creating a Vision for Space Medicine during Travel beyond Earth Orbit, to examine the issues surrounding astronaut health and safety for long duration space missions. The primary theme of the committee’s final report is that there is not enough known about the risks to human health during long-duration missions beyond Earth’s orbit and ways to effectively mitigate those risks in an environment of deep space. In 2014, the IOM convened the Committee on Ethics Principles and Guidelines for Health Standards for Long Duration and Exploration Spaceflights and released a report emphasizing the importance of prevention, mitigation, and treatment of major risks to human health during exploration spaceflight. NASA’s Human Research Program has organized five distinct categories of spaceflight hazards summarized by the acronym “RIDGE” (Space Radiation, Isolation and Confinement, Distance from Earth, Gravity fields, and Hostile/Closed Environments) that astronauts may encounter during exploration spaceflight. From those hazards, NASA further derived 30 of the most critical human health and performance risks, including limits to medical care resulting from pharmaceutical degradation. As we prepare for more distant exploration missions to Mars and beyond, risk management planning for astronaut healthcare should include the assembly of a medication formulary that is comprehensive enough to prevent or treat anticipated medical events, remains safe and chemically stable, and retains sufficient potency to last for the duration of the mission. The present editorial will summarize the current state of knowledge regarding innovative formulary optimization strategies, pharmaceutical stability assessment techniques, and storage and packaging solutions that could enhance drug safety and efficacy for future exploration spaceflight missions.

drug degradation risk assessment↗