Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy use”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Implementation of Creep-Damage Model for Concrete Fracture in MOOSE

Numerical implementation of an isotropic creep-damage model for concrete in multiphysics object-oriented simulation environment (MOOSE) finite element framework is presented in this paper. The constitutive model considers the combined effect of instantaneous and delayed strains on damage propagation. The implementation considers creep using generalized Maxwell or Kelvin-Voigt models. Using strain splitting assumptions, the total mechanical strains are split into elastic and creep components. Damage is considered to evolve as a function of the elastic and creep strains. This work considers damage as a function of fracture energy using the characteristic length of each finite element. This approach preserves the energy release rate of each element and avoids vanishing energy dissipation as the mesh is refined. Further, a creep-damage parameter is used to quantify the effect of creep strain on damage. The model is tested against published results on notched three-point bending specimens involving non-linear creep and predicts that about a third of the creep strain contributes towards damage for the experiments simulated. Results show that the proposed framework has predictive capabilities, and the model can be extended for more complex systems.

36 MATERIALS SCIENCE↗

Energy Master Planning: Identifying Framing Constraints that Scope Your Technology Options

This paper addresses the framing constraints for building and community energy projects that must be considered when energy master planning (EMP) is conducted. The constraints cover emissions, sustainability, resilience, regulations and directives, and regional and local limitations such as available energy types, local conditions, and project requirements. The paper reflects development results from participants in an International Energy Agency project on energy master planning and in a U.S. Department of Defense project on technology integration to achieve resilient, low-energy use military installations. It identifies a comprehensive list of framing constraints categorized into locational threats, locational resources, energy and water distribution and storage systems, building and facility, indoor environmental, and equipment in buildings and district systems constraints. In addition, it identifies limits for these constraints that exist in seven participating countries. Some framing constraints can profoundly impact technology selection while others impact the installation of technologies (as in hardening) and have little to no impact on technology selection. Furthermore, framing constraints can be assessed in different ways and there are resources available to help EMP stakeholders evaluate them. Finally, a case is made that identifying and applying framing constraints early in EMP can bring efficiencies and better focus to the EMP process. We come to the conclusion that (1) for holistic energy planning, it is essential to identify and assess the framing constraints that bound an optimized EMP solution, (2) framing constraints limits should be evaluated as either hard or soft or promising technologies may fall out of an EMP analysis, (3) to maintain consistent quality in the EMP process, the identification of framing constraints and their limits, and perhaps their evaluation, should be standardized, (4) a standardized approach could establish a baseline that can be used, built upon, and improved, (5) as automated EMP tools are improved or developed, the resources in this paper could possibly contribute to their interworkings relative to technology screening, and (6) continued climate change and resulting aggressive goal setting will likely drive a continued and strong emphasis on EMP.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Net-zero CO 2 by 2050 scenarios for the United States in the Energy Modeling Forum 37 study

The Energy Modeling Forum (EMF) 37 study on deep decarbonization and high electrification analyzed a set of scenarios that achieve economy-wide net-zero carbon dioxide (CO 2 ) emissions in North America by mid-century, exploring the implications of different technology evolutions, policies, and behavioral assumptions affecting energy supply and demand. Here, for this paper, 16 modeling teams reported resulting emissions projections, energy system evolution, and economic activity. This paper provides an overview of the study, documents the scenario design, provides a roadmap for complementary forthcoming papers from this study, and offers an initial summary and comparison of results for net-zero CO 2 by 2050 scenarios in the United States. We compare various outcomes across models and scenarios, such as emissions, energy use, fuel mix evolution, and technology adoption. Despite disparate model structure and sources for input assumptions, there is broad agreement in energy system trends across models towards deep decarbonization of the electricity sector coupled with increased end-use electrification of buildings, transportation, and to a lesser extent industry. All models deploy negative emissions technologies (e.g., direct air capture and bioenergy with carbon capture and storage) in addition to land sinks to achieve net-zero CO 2 emissions. Important differences emerged in the results, showing divergent pathways among end-use sectors with deep electrification and grid decarbonization as necessary but not sufficient conditions to achieve net zero. These differences will be explored in the papers complementing this study to inform efforts to reach net-zero emissions and future research needs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Design And Control of Thermal Storage for Ventilative Cooling in Multifamily Buildings (Final Report)

The concept of natural ventilation is to provide a heat sink for cooling the building during the occupancy periods at night and improve indoor thermal comfort during the daytime without or with minimal need for mechanical cooling. Commonly, natural ventilation through the window or mechanical circulation of the air through the ventilation ducts are two key methods used to achieve night ventilation. Due to the increasing electric need for space heating and cooling, renewable energies combined with energy storage systems are receiving attention worldwide nowadays. When designed and controlled properly, this strategy can reduce energy use for cooling, reduce the size of mechanical cooling equipment, reduce peak electrical demand for cooling, and better enable demand flexibility for mechanical cooling equipment. In some cases, ventilative cooling can eliminate the need for mechanical cooling altogether. For these reasons, California’s Building Energy Efficiency Standards have recently added prescriptive requirements that all new single-family residences (in most California climates) must include ventilative cooling systems (aka: “whole house fans”). However, the current standards do not address multifamily buildings because market-available ventilative cooling products are designed for single-family residences and are physically incompatible with many multifamily building archetypes. The results from the study show that the combination of thermal energy storage on building walls along with nighttime ventilation cooling assisted with nighttime ventilation can save total building energy usage by up to 9% and peak load by 16% in moderate climate zones. The controlled nighttime ventilation cooling (activate ventilation only when outdoor conditions are favorable) can also provide total electricity savings of up to 5% and 7% in hot and cold climates, respectively. In the case of moderate climates, kitchen exhaust-assisted nighttime ventilation cooling can eliminate the need for cooling during overnight hours. This can also significantly assist in reducing carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mapping the pathways of photo-induced ion migration in organic-inorganic hybrid halide perovskites

Abstract Organic-inorganic hybrid perovskites exhibiting exceptional photovoltaic and optoelectronic properties are of fundamental and practical interest, owing to their tunability and low manufacturing cost. For practical applications, however, challenges such as material instability and the photocurrent hysteresis occurring in perovskite solar cells under light exposure need to be understood and addressed. While extensive investigations have suggested that ion migration is a plausible origin of these detrimental effects, detailed understanding of the ion migration pathways remains elusive. Here, we report the characterization of photo-induced ion migration in perovskites using in situ laser illumination inside a scanning electron microscope, coupled with secondary electron imaging, energy-dispersive X-ray spectroscopy and cathodoluminescence with varying primary electron energies. Using methylammonium lead iodide and formamidinium lead iodide as model systems, we observed photo-induced long-range migration of halide ions over hundreds of micrometers and elucidated the transport pathways of various ions both near the surface and inside the bulk of the samples, including a surprising finding of the vertical migration of lead ions. Our study provides insights into ion migration processes in perovskites that can aid perovskite material design and processing in future applications.

14 SOLAR ENERGY↗

Reversible Surface Energy Storage in Molecular-Scale Porous Materials

Forcible wetting of hydrophobic pores represents a viable method for energy storage in the form of interfacial energy. The energy used to fill the pores can be recovered as pressure–volume work upon decompression. For efficient recovery, the expulsion pressure should not be significantly lower than the pressure required for infiltration. Hysteresis of the wetting/drying cycle associated with the kinetic barrier to liquid expulsion results in energy dissipation and reduced storage efficiency. In the present work, we use open ensemble (Grand Canonical) Monte Carlo simulations to study the improvement of energy recovery with decreasing diameters of planar pores. Near-complete reversibility is achieved at pore widths barely accommodating a monolayer of the liquid, thus minimizing the area of the liquid/gas interface during the cavitation process. At the same time, these conditions lead to a steep increase in the infiltration pressure required to overcome steric wall/water repulsion in a tight confinement and a considerable reduction in the translational entropy of confined molecules. In principle, similar effects can be expected when increasing the size of the liquid particles without altering the absorbent porosity. While the latter approach is easier to follow in laboratory work, we discuss the advantages of reducing the pore diameter, which reduces the cycling hysteresis while simultaneously improving the stored-energy density in the material.

36 MATERIALS SCIENCE↗

Energy performance of an operational government building retrofitted with ceiling phase change material tiles in a mixed-humid climate

The aging U.S. building stock requires various retrofit measures to enhance their energy efficiency. Here, this study explores the integration of thermal energy storage and advanced building controls as viable retrofit solutions for load flexibility and peak demand response while maintaining the occupants' comfort. A detailed assessment is conducted on the energy use of an administrative building in Sumner County, Kansas, focusing on the implementation of phase change materials (PCMs) in the ceiling of occupied zones. First, a time-resolved, whole-building energy model is developed in EnergyPlus, incorporating complex thermal behaviors such as air exchange between the plenum space and occupied zones, envelope leakage, and operational schedules. The model is then validated using experimental field test data, and subsequently a parametric assessment of key PCM properties and application strategies is performed to evaluate cooling electricity demand benefits. The parametric study shows that the optimal retrofit strategy, comprising a PCM with 23°C peak melting temperature, 0.125 in. (3.17 mm) thickness, and 150 kJ/kg latent heat, combined with active controls that include 8 h of precooling, forced convection under the ceiling, and a 2°C thermostat setback during peak hours, can result in a maximum load shift during the peak period of 99.6 % and the total electricity savings during the peak period of 98.9 % for the optimum case and thus provide significant cost savings under time-of-use pricing scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Billion-pixel x-ray camera (BiPC-X)

The continuing improvement in quantum efficiency (above 90% for single visible photons), reduction in noise (below 1 electron per pixel), and shrink in pixel pitch (less than 1 μm) enable billion-pixel x-ray cameras (BiPC-X) based on commercial complementary metal–oxide–semiconductor (CMOS) imaging sensors. We describe BiPC-X designs and prototype construction based on flexible tiling of commercial CMOS imaging sensors with millions of pixels. Device models are given for direct detection of low energy x rays (<10 keV) and indirect detection of higher energies using scintillators. Modified Birks’s law is proposed for light yield non-proportionality in scintillators as a function of x-ray energy. Single x-ray sensitivity and spatial resolution have been validated experimentally using a laboratory x-ray source and the Argonne Advanced Photon Source. Possible applications include wide field-of-view or large x-ray aperture measurements in high-temperature plasmas, the state-of-the-art synchrotron, x-ray free electron laser, and pulsed power facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Environmental trade-offs of direct air capture technologies in climate change mitigation toward 2100

Abstract Direct air capture (DAC) is critical for achieving stringent climate targets, yet the environmental implications of its large-scale deployment have not been evaluated in this context. Performing a prospective life cycle assessment for two promising technologies in a series of climate change mitigation scenarios, we find that electricity sector decarbonization and DAC technology improvements are both indispensable to avoid environmental problem-shifting. Decarbonizing the electricity sector improves the sequestration efficiency, but also increases the terrestrial ecotoxicity and metal depletion levels per tonne of CO 2 sequestered via DAC. These increases can be reduced by improvements in DAC material and energy use efficiencies. DAC exhibits regional environmental impact variations, highlighting the importance of smart siting related to energy system planning and integration. DAC deployment aids the achievement of long-term climate targets, its environmental and climate performance however depend on sectoral mitigation actions, and thus should not suggest a relaxation of sectoral decarbonization targets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Addressing Rising Energy Demand Through Innovation

The U.S. is facing a significant increase in energy demand, driven by AI advancements, the rapid expansion of data centers, manufacturing and industrial growth, and the electrification of transportation and buildings. Buildings alone account for approximately 75% of U.S. electricity consumption and 40% of total energy use. To address these challenges, NLR leverages its state-of-the-art research facilities, advanced energy modeling, hardware-in-the-loop emulation, and real-world demonstrations to provide data-driven insights that de-risk emerging energy solutions, increase efficiency and demand flexibility, optimize grid controls, and identify vulnerabilities to enhance energy security. This presentation will highlight our research ecosystem and its role in supporting a more reliable, affordable, and adaptive energy infrastructure in the face of accelerating demand.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Revenue prediction for integrated renewable energy and energy storage system using machine learning techniques

Revenue estimation for integrated renewable energy and energy storage systems is important to support plant owners or operators’ decisions in battery sizing selection that leads to maximized financial performances. A common approach to optimizing revenues of a hybrid hydro and energy storage system is using mixed-integer linear programming (MILP). Although MILP models can provide accurate production cost estimations, they are typically very computationally expensive. To provide a fast yet accurate first-step information to hydropower plant owners or operators who consider integrating energy storage systems, we propose an innovative approach to predicting optimal revenues of an integrated energy generation and storage system. In this study, we examined the performance of two prediction techniques: Generalized Additive Models (GAMs) and machine learning (ML) models developed based on artificial neural networks (ANN). Predictive equations and models are generated based on optimized solutions from a market participation optimization model, the Conventional Hydropower Energy and Environmental Resource System (CHEERS) model. The two predicting techniques reduce the computational time to evaluate annual revenue for one set of battery configurations from 3 h to 1 to 4 min per run while also being implementable with significantly less data. The model validation prediction errors of developed GAMs and ML models are generally below 5%; for model testing predictions, the ML models consistently outperform the regression equations in terms of root mean square errors. This new approach allows plant owners, operators, or potential investors to quickly access multiple battery configurations under different energy generation and market scenarios. This new revenue prediction method will therefore help reduce the barriers, and thereby promoting the deployment of battery hybridization with existing renewable energy sources.

13 HYDRO ENERGY↗

Characterizing x-ray transmission through filters used in high energy density physics diagnostics

We report on the design and implementation of a new system used to characterize the energy-dependent x-ray transmission curve, Θ(E), through filters used in high-energy density physics diagnostics. Using an Amptek X-123-CdTe x-ray spectrometer together with a partially depleted silicon surface barrier detector, both the energy spectrum and total emission of an x-ray source have been accurately measured. By coupling these detectors with a custom PROTO-XRD x-ray source with interchangeable cathodes, accurate characterizations of Θ(E) for filters of varying materials and thicknesses have been obtained. The validity of the technique has been confirmed by accurately reproducing areal densities for high-purity filters with known x-ray transmission properties. In this paper, the experimental setup is described and the results of absorption calibrations performed on a variety of different filters are presented.

47 OTHER INSTRUMENTATION↗

Characterizing x-ray transmission through filters used in high energy density physics diagnostics

We report on the design and implementation of a new system used to characterize the energy-dependent x-ray transmission curve, Θ(E), through filters used in high-energy density physics diagnostics. Using an Amptek X-123-CdTe x-ray spectrometer together with a partially depleted silicon surface barrier detector, both the energy spectrum and total emission of an x-ray source have been accurately measured. By coupling these detectors with a custom PROTO-XRD x-ray source with interchangeable cathodes, accurate characterizations of Θ(E) for filters of varying materials and thicknesses have been obtained. The validity of the technique has been confirmed by accurately reproducing areal densities for high-purity filters with known x-ray transmission properties. In this paper, the experimental setup is described and the results of absorption calibrations performed on a variety of different filters are presented.

Pearcy, J.↗

Development of High Energy Resolution Fluorescence Detection Methods for Advanced Microscale X-ray Absorption Fine Structure Analysis of Critical Elements (Final Report)

This project is developing High-Energy Resolution Fluorescence Detection (HERFD) X-ray Absorption Fine-Structure Spectroscopy (XAFS) at the hard X-ray microprobe beamline at GSECARS beamline 13-ID-E, at the Advanced Photon Source at Argonne National Laboratory. This enhancement will improve sensitivity and spectral interpretation limitations of conventional XAFS which uses energy dispersive solid-state detectors (SSD) to measure the total fluorescence yield (TFY-XAFS). By using high-quality Si and Ge crystal analyzers to select X-ray fluorescence (XRF) from specific emission lines, background signals from other elements or X-ray scattering that can paralyze SSDs can be nearly eliminated, improving the sensitivity to the oxidation and chemical state of dilute species even though the solid angle of the analyzers is relatively small. Furthermore, by using analyzers of low-strain Si or Ge, the energy selection can be smaller than the natural widths of the core electron level. We are particularly interested in applying these enhanced sensitivities to Lanthanide series of rare-earth elements, which are typically at concentrations at or below 10 ppm, and where spectral overlaps with the 3rd row transition metals degrade sensitivity.

47 OTHER INSTRUMENTATION↗

Reduced scaling formulation of CASPT2 analytical gradients using the supporting subspace method

We present a reduced scaling and exact reformulation of state specific complete active space second-order perturbation (CASPT2) analytical gradients in terms of the MP2 and Fock derivatives using the supporting subspace method. This work follows naturally from the supporting subspace formulation of the CASPT2 energy in terms of the MP2 energy using dressed orbitals and Fock builds. For a given active space configuration, the terms corresponding to the MP2-gradient can be evaluated with O(N5) operations, while the rest of the calculations can be computed with O(N3) operations using Fock builds, Fock gradients, and linear algebra. When tensor-hyper-contraction is applied simultaneously, the computational cost can be further reduced to O(N4) for a fixed active space size. The new formulation enables efficient implementation of CASPT2 analytical gradients by leveraging the existing graphical processing unit (GPU)-based MP2 and Fock routines. We present benchmark results that demonstrate the accuracy and performance of the new method. Example applications of the new method in ab initio molecular dynamics simulation and constrained geometry optimization are given.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Open Building Operating System: An Open-Source Grid Responsive Control Platform for Buildings

Grid-interactive efficient buildings (GEBs) with flexible loads are a promising method to decarbonize buildings, shift loads during peak hours, and lower energy use and electricity costs. Despite the promising benefits of GEBs, automation systems that manage flexible loads in response to energy prices or other grid signals are still uncommon in small and medium commercial buildings. Recent literature demonstrates such control solutions, but they often rely on custom integrations lacking the tools and drivers needed for scalability. To address these gaps, our team has created a fully open-source software stack capable of integrating heterogeneous flexible building loads and implementing integrated portable control applications called the Open Building Operating System (OpenBOS). The software can be deployed over existing control architecture with a small capital cost. OpenBOS leverages semantic models, which have been the subject of recent investigations to facilitate application portability. The use of semantic data reduces the labor and expense required to deploy and update smart control applications, increasing scalability. In this paper, the semantic modeling schema "Brick" was used, but the proposed approach can also be applied to ASHRAE standard 223P, when released. This paper describes the methodology and software components of OpenBOS and demonstrates its functionality with a rule-based demand flexibility control application configured using a semantic model. This application was tested at a real building in NY that uses a dual-fuel heating system made up of five ductless heat pump mini-splits and a central furnace serving a single zone. The demonstration reduced electricity costs at the site by 27%, demand during a shed event by 49%, and furnace usage by 35%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A System of Agents for Supporting Optimization and Control of a Connected Community

The residential sector consumes a significant portion of the electricity sold in the United States. Above 60% of the energy used in the sector is used to operate heating, ventilation, and air conditioning (HVAC) systems and water heating (WH) systems. With the increase of intelligence in the grid and the new decision and control options enabled by the Internet of Things; control of these devices can be used to support the grid. Therefore, this article presents a scalable multiagent system for optimizing HVAC and WH systems while maintaining comfort. It allows a utility to orchestrate the shifting of energy from critical periods without direct control, but instead by using a price signal. The architecture, optimization formulation, implementation strategy and results from an implementation project are discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nontargeted vs. Targeted vs. Smart Load Shifting Using Heat Pump Water Heaters

Deployment of CTA-2045–enabled devices is increasing in the U.S. market. These devices allow utilities or third-party aggregators to control appliance energy use in homes, and could also be applied to end uses in small commercial buildings. This study focuses on a field study using CTA-2045–enabled water heaters to shift electric load off the peak and toward periods when renewable resources are more prevalent (e.g., near noon for solar resources and near midnight for wind resources). The following load shifting strategies were compared to understand effects on the aggregate load-shifting capabilities of Heat Pump Water Heaters (HPWHs) and on consumer hot water supply: non-targeted (traditional), targeted (grouped, with different shifting schedules) and “smart” (adaptive control commands). The results of this study show that targeted and smart control strategies yield significantly more load-shifting potential from a population of water heaters than the non-targeted approach without sacrificing hot water supply to occupants. However, as control commands become more aggressive, aggregators may face challenges in meeting consumer hot water demand. Furthermore, the findings and lessons learned can benefit electric utilities and inform updates to manufacturer controls and communications standards. The data collected may also be useful for developing and validating HPWH models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗