A Neural Network-Based Power Mismatch Elimination Strategy for Integrated Solar and ESS AC/DC Systems (MARS)

The multiport autonomous reconfigurable solar power plant (MARS) is a promising concept for the integration of photovoltaic (PV) and energy storage system (ESS) to the transmission ac grid and a high-voltage direct current (HVdc) link. The presence of PV and ESS in each arm of the MARS results in uneven distribution of active power among different submodules (SMs), thereby leading to unbalanced SM capacitor voltages and potentially compromising the system stability. Moreover, in the case of partial shadings, shaded PV SMs will suffer from decreased power injections causing power mismatch in the MARS system. To address this issue, a neural-network-based power mismatch elimination (NNPME) strategy is proposed in this article. The proposed NNPME strategy optimizes ESS usage and leverages both dc and ac circulating currents to facilitate power transfer among the SMs, arms, and phases of the MARS system. Simulation and control hardware-in-the-loop (cHIL) experiments demonstrate the effectiveness of the proposed NNPME strategy. Compared with the traditional approaches, the proposed NNPME strategy can significantly enhance system efficiency and ensure stable and continuous operation, even in the presence of uneven power distribution within the MARS system.

14 SOLAR ENERGY↗

Targeted Energy Management System Toolset

TEMST integrates advanced sensor systems with advanced computational intelligence, e.g. neural networks and fuzzy arithmetic, to enable effective energy management while minimizing negative human comfort consequences and promoting improved occupant satisfaction. Preliminary work suggests that energy cost reductions above ten percent are easily achievable. In addition to optimizing existing Energy Management Systems (EMS), the proposed toolset will be both resilient and secure in order to proactively maintain a safe level of operational normalcy in response to anomalies and malicious actions.

Rieger, CraigG.↗

Dynamic Optimal Dispatch of Energy Systems with Intermittent Renewables and Damage Model

With the increasing penetration of intermittent renewable energy sources into the grid, there is a growing need for process systems-based strategies that integrate dispatchable and variable energy systems for supplying the demand while maintaining grid reliability. The proposed framework corresponds to a dynamic mixed-integer linear programming optimization approach that integrates coal-fired and natural gas-fired power plants, NaS batteries for energy storage, and solar/wind energy to supply the demand. This optimization approach considers an economic goal and constraints to provide power balance while maintaining the overall damage of the natural gas combined cycle (NGCC) power plant drum under a maximum stress as well as avoiding the overheating of the NGCC superheater and reheater. Renewable curtailment levels are also retained at minimum levels. Case studies are analyzed considering different loads and renewable penetration levels. The results show that the demand was met for all cases. Grid flexibility was mostly provided by the NGCC, while the batteries were used sparingly. In addition, considering a CO 2 equivalent analysis, the environmental performance was intrinsically connected to grid flexibility and the level of renewable penetration. Stress analysis results reinforced the necessity for an equipment health-related constraint.

97 MATHEMATICS AND COMPUTING↗

Development of High Yield Feedstocks and Biomass Conversion Technology for Renewable Energy

This project had two main goals. The first goal was to evaluate several high yielding tropical perennial grasses as feedstock for biofuel production, and to characterize the feedstock for compatible biofuel production systems. The second goal was to assess the integration of renewable energy systems for Hawaii. The project focused on high-yield grasses (napiergrass, energycane, sweet sorghum, and sugarcane). Field plots were established to evaluate the effects of elevation (30, 300 and 900 meters above sea level) and irrigation (50%, 75% and 100% of sugarcane plantation practice) on energy crop yields and input. The test plots were extensive monitored including: hydrologic studies to measure crop water use and losses through seepage and evapotranspiration; changes in soil carbon stock; greenhouse gas flux (CO 2 , CH 4 , and N 2 O) from the soil surface; and root morphology, biomass, and turnover. Results showed significant effects of environment on crop yields. In general, crop yields decrease as the elevation increased, being more pronounced for sweet sorghum and energycane than napiergrass. Also energy crop yields were higher with increased irrigation levels, being most pronounced with energycane and less so with sweet sorghum. Daylight length greatly affected sweet sorghum growth and yields. One of the energy crops (napiergrass) was harvested at different ages (2, 4, 6, and 8 months) to assess the changes in feedstock characteristics with age and potential to generate co-products. Although there was greater potential for co-products from younger feedstock, the increased production was not sufficient to offset the additional cost of harvesting multiple times per year. The feedstocks were also characterized to assess their compatibility with biochemical and thermochemical conversion processes. The project objectives are being continued through additional support from the Office of Naval Research, and the Biomass Research and Development Initiative. Renewable energy assessments included: biomass feedstocks currently being produced by Hawaiian Commercial & Sugar Co., and possibilities of producing methane from agricultural and livestock wastes and the potential of photovoltaic systems for irrigation pumping at HC&S. Finally, the impact of a micro-hydroelectric system on a small-farm economics and the local community was assessed.

09 BIOMASS FUELS↗

PV-BESS DC-Series Integration for Regulated DC Systems

DC-series integration introduces a novel approach to seamlessly integrate a solar photovoltaic (PV) array and a battery energy storage (BES) in series. This system, referred to as the PV-integrated battery energy storage system—dc series (PVBESS-DCS), simplifies integration and enhances power density by leveraging the inherent voltage-source characteristics of batteries and adopting the concept of partial power processing. However, addressing voltage variations of a PV array and a BES under different operational conditions remains a challenge to apply the PVBESS-DCS to a regulated dc system, where the dc-bus voltage is fixed. This article proposes a PVBESS-DCS solution tailored for regulated dc systems. Within this framework, we present a controllable series voltage source compensating for the voltage differences between the PV and BES sources and the dc bus. Thus, the system can perform PV maximum power point tracking and curtailment control while charging and discharging BES and connected to a regulated dc bus. Additionally, we present a single-stage multiport partial power processing dc–dc converter designed for the proposed PVBESS-DCS. It utilizes a triple active bridge dc–dc converter topology. Finally, this article presents operating principles, control strategies, simulation results, and experimental findings of the proposed PVBESS-DCS for regulated dc systems.

25 ENERGY STORAGE↗

Thermal Analysis of of Near-Isothermal Compressed Gas Energy Storage System

In this paper, alternative system configurations for a novel Ground-Level Integrated Diverse Energy Storage (GLIDES) system, which can store energy via input of electricity and heat and deliver dispatchable electricity, is presented. The proposed system is low-cost and hybridizes compressed air and pumped hydro storage approaches that will allow for the off-peak storage of intermittent renewable energy for use during peak times. This study reveals that implementing direct-contact low grade heat exchange via sprayed falling droplets to cool the gas during charging (compression) and warm the gas during discharging (expansion) can be achieved through a secondary recirculating loop of liquid. This study shows that if the recirculating liquid loop is pre-conditioned with waste-heat prior to spraying during gas expansion and considering all the round trip conversion losses from standard 120 V 60 HZ electricity input and output with utilization of low grade heat at 90 C the alternative system design leads to a 16% boost in round trip efficiency of the electricity storage to elec = 82% with an energy density of ED = 3.59 MJ/m3.

25 ENERGY STORAGE↗

Anomaly Detection and Mitigation for Dynamic Frequency Regulation in Hydropower-Battery Systems: Preprint

Hydropower operators and energy storage providers are increasingly interested in participating in frequency regulation services, driven by the incentives offered by independent system operators, such as the Pennsylvania-New Jersey-Maryland Interconnection (PJM), in a competitive electricity market. This transition, however, unfolds against the backdrop of a modernizing and rapidly digitizing power grid, exposing the integrated legacy infrastructure and vulnerable communication networks to a multitude of cybersecurity threats. These evolving threats not only endanger grid operations but also have the potential to trigger cascading disruptions across the broader grid network and influence regulation markets. This work presents an approach for developing an anomaly detection and mitigation system to address cybersecurity challenges during the participation of a hydropower-integrated battery energy storage system (BESS) in a frequency regulation market. The applied anomaly detector utilizes machine learning algorithms to provide detailed classification of cyber-physical events and provide a comprehensive situation awareness to grid operators. Later, the applied mitigation system triggers predefined corrective actions to minimize the impact of data integrity attacks on the regulation market and system stability. We evaluated the proposed approach on a fully active BESS topology using the slow regulation signal (Reg A) coming from the PJM market. Our simulation results reveal that the proposed approach performs well in detecting data integrity attacks within the allocated time frame and also minimizes the system's instability and economic loss during the participation of hydropower and BESS in the regulation market.

battery energy storage system↗

Hydropower Advantages over Batteries in Energy Storage of Off-Grid Systems: A Case Study

Microgrids are decentralized power production systems, where the energy production and consumption are very close to each other. Microgrids generally exploit renewable energy sources, encountering a problem of storage, as the power production from solar and wind is intermittent. This research presents a new integrated methodology and discusses a comparison of batteries and pumped storage hydropower (PSH) as energy storage systems with the integration of wind and solar PV energy sources, which are the major upcoming technologies in the renewable energy sector. We implemented the simulator and optimizer model (HOMER), which develops energy availability usage to obtain optimized renewable energy integration in the microgrid, showing its economic added value. Two scenarios are run with this model—one considers batteries as an energy storage technology and the other considers PSH—in order to obtain the best economic and technical results for the analyzed microgrid. The economic analysis showed a lower net present cost (NPC) and levelized cost of energy (LCOE) for the microgrid with PSH. The results showed that the microgrid with the storage of PSH was economical, with an NPC of 45.8 M€ and an LCOE of 0.379 €/kWh, in comparison with the scenario with batteries, which had an NPC of 95.2 M€ and an LCOE of 0.786 €/kWh. The role of storage was understood by differentiating the data into different seasons, using a Python model. Furthermore, a sensitivity analysis was conducted by varying the capital cost multiplier of solar PV and wind turbines to obtain the best optimal economic solutions.

Guruprasad, Prajwal↗

Solid-State Transformer and Hybrid Transformer With Integrated Energy Storage in Active Distribution Grids: Technical and Economic Comparison, Dispatch, and Control

Solid-state transformer (SST) and hybrid transformer (HT) are promising alternatives to the line-frequency transformer (LFT) in smart grids. The SST features medium-frequency isolation, full controllability for voltage regulation, reactive power compensation, and the capability of battery energy storage system (BESS) integration with multiport configuration. The HT has a partially-rated converter for fractional controllability and can integrate a small BESS. Fast grid-edge voltage fluctuations from increased solar photovoltaic (PV) and electric vehicle (EV) penetration are difficult to manage for mechanical load tap changers. Hence, along with the trend towards more BESS in the grid, the controllability and the storage integration capability of the SST and HT are of strong interest. However, a review of literature shows existing SST and HT research is mostly at converter level, while system-level assessments are scarce. Assessing technical and economic impacts is critical to understanding the benefits and role of the SST and HT to guide future research, which is presented for the first time in this article. Experimental results from medium-voltage (MV) SST and MV HT prototypes are shown to confirm equipment-level feasibility, where the voltage controllability waveforms of a MV HT prototype are reported for the first time. Comparative simulations are performed on a modified IEEE 34-bus system. Here, a grid-model-less decentralized grid-edge voltage control method and a day-ahead BESS dispatch method are proposed for the SST and HT. The simulations show that the SST and HT with integrated storage can host more PV, achieve peak shaving, mitigate voltage fluctuation and reverse power flow, and support energy arbitrage for operational cost reduction, as compared to the LFT. Moreover, comprehensive analyses of net present value (NPV) and internal rate of return (IRR) are performed under different installed PV capacities, HT’s partial converter ratings, and BESS capacities. Sensitivities to future cost reductions of the PV and BESS are studied. Although the NPV and IRR are currently negative, 60% capital cost reduction or 150% revenue increase will make the SST and HT economically viable in the use case studied.

14 SOLAR ENERGY↗

Optimal Energy Storage Schedules for Load Leveling and Ramp Rate Control in Distribution Systems

Continued integration of distributed energy resources (DERs) into the grid, such as solar PVs, at a large-scale, contributes into the famous Duck Curve. New DER management algorithms are therefore deemed necessary to alleviate rapid variations within net load profiles of distribution systems. Herein this paper proposes a process to determine the optimal energy storage schedules for leveling the distribution circuit feederhead net load. A series of sensitivity analyses shows how the proposed method can be used to determine the optimal energy storage schedules with different capacities, state of charge requirements, and net load ramp rate limitations.

25 ENERGY STORAGE↗

Integrating Variable Renewable Energy in Electric Power Markets: Best Practices from International Experience

Many countries—reflecting very different geographies, markets, and power systems—are successfully managing high levels of variable renewable energy on the electric grid, including that from wind and solar energy. This study documents the diverse approaches to effective integration of variable renewable energy among six countries—Australia (South Australia), Denmark, Germany, Ireland, Spain, and the United States (Colorado and Texas)—and summarizes policy best practices that energy ministers and other stakeholders can pursue to ensure that electricity markets and power systems can effectively coevolve with increasing penetrations of variable renewable energy. There is no one-size-fits-all approach; each country has crafted its own combination of policies, market designs, and system operations to achieve the system reliability and flexibility needed to successfully integrate renewables. Notwithstanding this diversity, the approaches all coalesce around five strategic areas: lead public engagement, particularly for new transmission; coordinate and integrate planning; develop rules for market evolution that enable system flexibility; expand access to diverse resources and geographic footprint of operations; and improve system operations. The study also emphatically underscores the value of countries sharing their experiences. The more diverse and robust the experience base from which a country can draw, the more likely that it will be able to implement an appropriate, optimized, and system-wide approach.

17 WIND ENERGY↗

High Penetration PV Deployment in the Arizona Public Service System

In an effort to better understand the impacts of high penetrations of photovoltaic (PV) generators on distribution systems, Arizona Public Service (APS) and its partners have begun work on a multi-year project to develop the tools and knowledgebase needed to safely and reliably integrate high penetrations of utility and residential scale PV. Building upon the APS Community Power Project - Flagstaff Pilot, this project will analyze the impact of PV on a representative feeder in northeast Flagstaff. To quantify and catalog the effects of the estimated 1.5 MW of PV that will be installed on the feeder (both smaller units at homes as well as large, centrally located systems), high-speed weather and electrical data acquisition systems and digital 'smart' meters are being designed and installed to facilitate monitoring and to build and validate comprehensive, high-resolution models of the distribution system. These models will be used to analyze the impacts of the PV on distribution circuit protection systems (including anti-islanding), predict voltage regulation and phase balance issues, and develop volt/var control schemes. The goal of this paper is to provide insight and lessons learned on the early stages of high penetration PV deployment. Primarily focusing on modeling and data acquisition, this paper describes the overall project, early results, and plans for future phases of the project.

14 SOLAR ENERGY↗

Analyzing the Multiscale Impacts of Implementing Energy-Efficient HVAC Improvements Through Energy Audits and Economic Input–Output Analysis

Abstract Heating, ventilation, and air-conditioning (HVAC) systems are usually an industry’s highest consumer of energy, most of which goes toward space cooling in buildings. Industrial energy-efficiency audits not only benefit manufacturers but also generate significant economic and environmental benefits to localities, states, and the nation. This article analyzes the micro- and macro scale impacts of implementing energy-efficient HVAC systems by integrating the industrial building energy data with the macroeconomic regional economic flow model. Micro-scale data include 10 years of historical energy, cost, and carbon dioxide savings achieved from energy-efficient HVAC implementation offered to manufacturers through industrial energy audits. The data were integrated into the macroeconomic modeling framework to illuminate the cascading regional economic impacts of implementing energy-efficient HVAC recommendations in manufacturing facilities. Results show that if recommendations had been implemented throughout all manufacturers in the region, $656 M energy costs would have been directly saved, 7.8 million metric tons of carbon dioxide emissions would have been avoided, and 4387 jobs could have been created, resulting in a total annual economic impact of $899 M stemming from direct, indirect, and induced impacts. The results offer insight into how industrial energy systems can be designed and provide models for how communities can accomplish a net-zero society.

Energy & Fuels↗

Improved Tools for Wind Resource Assessment with Remote Sensing Sodar Device: Cooperative Research and Development Final Report, CRADA Number: CRD-09-363

Under this Agreement, NREL will work with the Participant to characterize wind resource assessment measurement systems needed for the design, construction, and integration of wind energy conversion systems to produce electricity for utility grid applications. This work includes, but is not limited to, research and development of hardware and software systems needed to advance wind energy resource assessment technology at speed and scale for use by electric utilities and wind power system integrators.

17 WIND ENERGY↗

Integration of Biological, Physical/Chemical and Energy Efficient Systems in the CELSS Antarctic Analog: Performance of Prototype Systems and Issues for Life Support

The Controlled Ecological Life Support System (CELSS) Antarctic Analog Project (CAAP) is a joint endeavor between the National Science Foundation, Office of Polar Programs (NSF-OPP), and the National Aeronautics and Space Administration (NASA). The fundamental objective is to develop, deploy, and operate a testbed of advanced life support technologies at the Amundsen-Scott South Pole Station that enable the objectives of both the NSF and NASA. The functions of food production, water purification, and waste treatment, recycle, and reduction provided by CAAP will improve the quality of life for the South Pole inhabitants, reduce logistics dependence, enhance safety, and minimize environmental impacts associated with human presence on the polar plateau. Because of the analogous technical, scientific, and mission features with Planetary missions, such as a mission to Mars, CAAP provides NASA with a method for validating technologies and overall approaches to supporting humans. Prototype systems for waste treatment, water recycle, resource recovery and crop production are being evaluated in a testbed at Ames Research Center. The combined performance of these biological and physical/chemical systems as an integrated function in support of the human habitat will be discussed. Overall system performance will be emphasized. The effectiveness and efficiency of component technologies will be discussed in the context of energy and mass flow within the system and contribution to achieving a mass and energy conservative system. Critical to the discussion are interfaces with habitat functions outside of the closed-loop life support: the ability of the system to satisfy the life support requirements of the habitat and the ability to define input requirements. The significance of analog functions in relation to future Mars habitats will be discussed.

Bubenheim, David L.↗

Xcel Energy – LBNL ‘Beyond Widgets’ Project. Workstation Specific Lighting with Daylight Dimming Controls System Program Manual

This program manual was developed through a U.S. Department of Energy project to develop streamlined utility program approaches to the deployment of integrated systems in commercial offices. Integrated systems present deep opportunities for energy savings, however by nature these systems have additional levels of complexity and effort required for their design and energy savings assessment, which create barriers for utility incentive programs to develop streamlined cost effective incentive programs to capture these savings. This project worked with Xcel Energy in Colorado and Minnesota to select an integrated system and develop a streamlined approach to its deployment for small and large commercial offices. Xcel Energy worked with LBNL to select a workstation specific lighting system with daylight dimming controls, applied as a retrofit in commercial office spaces. Previous studies indicated a potential lighting annual energy savings of 28-63%, with an average of 47% for this system type, due to reduced fixture LPD and controls only, not including a full fixture replacement from a condition such as T8 to LED. Xcel also had a desire to incorporate this fixture replacement in their integrated system package, and as a result annual energy lighting savings are expected to be higher. FLEXLAB testing of the system for 500 lux minimum output conditions translated into a 94% annual energy savings for this system. Market analysis was developed for large and medium commercial office buildings in Xcel’s Minnesota and Colorado markets showing a potential for 48-295 and 120-672 GWh of energy savings potential for Colorado and Minnesota respectively. Total Resource Costs (TRC) vary by location and technology package used (enterprise versus non-enterprise lighting controls system), and vary from 0.29 to 1.27 and 0.06 and 0.44 for a Retrofit case, and 0.20 to 1.63 and 0.07 to 0.57 for a Replace on Burnout strategy for Colorado and Minnesota respectively. These results indicate good potential for demonstrating a strong technical and economic case for deployment of this system type in Xcel’s Colorado territory, while deployment in the Minnesota market may be advisable as well as part of a portfolio of programs, or as an effort to help shift the market into integrated systems deployment in general. It should be noted that the cost of avoided energy in both markets is significantly low ($0.07/kWh for Minnesota, $0.08/kWh for Colorado), and these TRC values would not be representative of deployment potential in other markets with higher utility rates. In addition, installation costs used for these systems may decrease with time, further enhancing their return on investment. Overall, workstation specific lighting systems with daylight dimming controls present a very strong potential for cost effective lighting energy savings, as demonstrated by the FLEXLAB test results and previous case studies. Further energy savings may be realized from the use of fixture-specific occupancy sensors as well, although this approach was not considered in this study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Small Hydro Power Plants with Integrated BESS for Enhance Resiliency

Battery energy storage systems (BESS) are an important asset for power systems with high integration levels of renewable energy, and they can be controlled to provide various services to the grid. This paper presents the hardware demonstration and characterization of using a utility-scale BESS with grid-following (GFL) and grid-forming (GFM) controls and a run-of-river (ROR) hydropower plant to perform a bottom-up power system black start that enhances power systems' resiliency. ROR hydropower plants are generally not used for power system restoration due to their frequency instability during islanded operation; however, BESS with droop control can provide critical damping to convert a ROR hydropower generator into a black start- capable unit. To demonstrate this, we carry out hardware experiments at the megawatt-scale integrating a synchronous generator driven by a dynamometer, an actual GFL/GFM BESS, a medium-voltage impedance network, and a load bank. The demonstration shows the different roles of BESS with GFL and GFM control in power system restoration. GFL BESS can suffer from high-frequency oscillations, even instability, depending on the droop control gain and loading condition. The results provide further insights for system operators on how GFL- or GFM controlled BESS can enhance grid stability and how hydro-BESS hybrids can operate as a black-start-capable unit. The presented experimental results are also a valuable resource to understand the different stability characteristics of real-world BESS with different control modes.

24 POWER TRANSMISSION AND DISTRIBUTION↗