Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy Data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Use of ground-based remotely sensed data for surface energy balance calculations during Monsoon '90

Surface energy balance was evaluated at a semiarid watershed using direct and indirect measurements of the turbulent fluxes, a remote technique based on measurements of surface reflectance and temperature, and conventional meteorological information. Comparison of remote estimates of net radiant flux and soil heat flux densities with measured values showed errors on the order of +/-40 W/sq m. To account for the effects of sparse vegetation, semi-empirical adjustments to aerodynamic resistance were required for evaluation of sensible heat flux density (H). However, a significant scatter in estimated versus measured latent heat flux density (LE) was still observed, +/-75 W/sq m over a range from 100-400 W/sq m. The errors of H and LE estimates were reduced to +/-50 W/sq m when observations were restricted to clear sky conditions.

Moran, M. S.↗

Data Network Equipment Energy Use and Savings Potential in Buildings

Network connectivity has become nearly ubiquitous, and the energy use of the equipment required for this connectivity is growing. Network equipment consists of devices that primarily switch and route Internet Protocol (IP) packets from a source to a destination, and this category specifically excludes edge devices like PCs, servers and other sources and sinks of IP traffic. This paper presents the results of a study of network equipment energy use and includes case studies of networks in a campus, a medium commercial building, and a typical home. The total energy use of network equipment is the product of the stock of equipment in use, the power of each device, and their usage patterns. This information was gathered from market research reports, broadband market penetration studies, field metering, and interviews with network administrators and service providers. We estimate that network equipment in the USA used 18 TWh, or about 1percent of building electricity, in 2008 and that consumption is expected to grow at roughly 6percent per year to 23 TWh in 2012; world usage in 2008 was 51 TWh. This study shows that office building network switches and residential equipment are the two largest categories of energy use consuming 40percent and 30percent of the total respectively. We estimate potential energy savings for different scenarios using forecasts of equipment stock and energy use, and savings estimates range from 20percent to 50percent based on full market penetration of efficient technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measurement of the energy response of the ATLAS calorimeter to charged pions from $W^{\pm }\rightarrow \tau ^{\pm }(\rightarrow \pi ^{\pm }\nu _{\tau })\nu _{\tau }$ events in Run 2 data

The energy response of the ATLAS calorimeter is measured for single charged pions with transverse momentum in the range 10 < p T < 300 GeV. The measurement is performed using 139 fb –1 of LHC proton–proton collision data at √s = 13 TeV taken in Run 2 by the ATLAS detector. Charged pions originating from τ-lepton decays are used to provide a sample of high-p T isolated particles, where the composition is known, to test an energy regime that has not previously been probed by in situ single-particle measurements. The calorimeter response to single-pions is observed to be overestimated by ~2% across a large part of the p T spectrum in the central region and underestimated by ~4% in the endcaps in the ATLAS simulation. The uncertainties in the measurements are ≲1% for 15 < p T < 185 GeV in the central region. To investigate the source of the discrepancies, the width of the distribution of the ratio of calorimeter energy to track momentum, the energies per layer and response in the hadronic calorimeter are also compared between data and simulation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Energy levels, lifetimes and radiative data of W LV

Calculations of energy levels, radiative data and lifetimes are reported for tungsten Ca-like ion (W LV) by using multi-configuration Dirac–Fock (MCDF) method. The GRASP2K package is adopted to carry out a large-scale systematic computation with a restricted active space treatment; the Breit interaction and QED effects are included in subsequent relativistic configuration interaction calculations. The energies and lifetimes of the lowest 119 levels are listed; the main leading configuration of the levels is of the ground state configuration [Ne]3s{sup 2}3p{sup 6}3d{sup 2} and the first excited configuration [Ne]3s{sup 2}3p{sup 5}3d{sup 3}. The wavelengths, radiative rates and oscillator strengths for relatively strong E1, E2, M1, and M2 transitions are listed. Comparisons with earlier experimental and theoretical values are made. The average relative deviations of energy levels from the NIST results and E1 transition wavelengths from the EBIT experimental results have turned to be only 0.20% and 0.13%, respectively. The other present results are in reasonable agreement with available data. These agreements confirm the reliability and accuracy of the current results. The present datasets may help us with the investigation of the electron–electron correlation effects in complex multi-electron highly charged heavy ions and of the diagnosis of tungsten impurity plasmas in fusion science.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Data Informed Vehicle Trip Energy Estimation [SWR-17-30]

There is a need to accurately estimate trip energy consumption for vehicle trips where high resolution GPS data is not available, or where the trips are simply proposed and have not been driven. This need is most apparent in green routing algorithms, it is critical to accurately estimate the energy consumption for a route that has not been driven. The Data Informed Energy Estimation Software addresses this need by identifying the driving and roadway attributes most impactful on fuel consumption, and using large amounts of high resolution GPS data from real world driving to determine the average fuel consumption for all combinations of attributes. These attributes can include traffic conditions, vehicle speed, and road gradient among others. This aggregation technique results in a lookup table that provides energy consumption values for combinations of road and driving techniques. This lookup table is an extremely lightweight and versatile result that can be applied in a number of applications.

Holden, Jacob↗

hpMCA: A Python-based Graphical Program for Energy Dispersive X-Ray Diffraction Data Collection and Analysis

Energy-dispersive X-ray diffraction (EDXD) at synchrotron beamlines is commonly used for the study of material properties under high pressure and/or high temperature. Experimenters typically rely on the availability of robust data collection and analysis at a beamline, but this has become increasingly difficult, especially with the introduction of multi-element detectors that generate complex, multi-dimensional data sets. These data sets have energy resolution, and they can also be resolved in relation to sample position, diffraction angle, or different external stimuli. We report a new Python-based graphical program, hpMCA, for EDXD data collection and analysis that streamlines the experimental process for the beamline users. The program features a user-friendly interface, capability for online viewing and analyzing data from multi-element energy-dispersive detectors, and includes features useful for working with samples under high pressure and/or high temperature, such as crystal phase identification, real-time unit cell lattice refinement, and pressure determination based on an equation of state.

data analysis software↗

Cosmic shear in harmonic space from the Dark Energy Survey Year 1 Data: compatibility with configuration space results

ABSTRACT We perform a cosmic shear analysis in harmonic space using the first year of data collected by the Dark Energy Survey (DES-Y1). We measure the cosmic weak lensing shear power spectra using the metacalibration catalogue and perform a likelihood analysis within the framework of CosmoSIS. We set scale cuts based on baryonic effects contamination and model redshift and shear calibration uncertainties as well as intrinsic alignments. We adopt as fiducial covariance matrix an analytical computation accounting for the mask geometry in the Gaussian term, including non-Gaussian contributions. A suite of 1200 lognormal simulations is used to validate the harmonic space pipeline and the covariance matrix. We perform a series of stress tests to gauge the robustness of the harmonic space analysis. Finally, we use the DES-Y1 pipeline in configuration space to perform a similar likelihood analysis and compare both results, demonstrating their compatibility in estimating the cosmological parameters S8, σ8, and Ωm. We use the DES-Y1 metacalibration shape catalogue, with photometric redshifts estimates in the range of 0.2−1.3, divided in four tomographic bins finding σ8(Ωm/0.3)0.5 = 0.766 ± 0.033 at 68 per cent CL. The methods implemented and validated in this paper will allow us to perform a consistent harmonic space analysis in the upcoming DES data.

79 ASTRONOMY AND ASTROPHYSICS↗

Wave Energy Prize Wave Calibration Data for the 1:20 Scale Testing at MASK

Time series data, sensor layout, and wave calibration summaries for the wave height measurements for the 10 calibration sea states for the 1:20 scale testing of the Wave Energy Prize (WEP) at the US Navy's Maneuvering and Seakeeping (MASK) Basin at the Naval Surface Warfare Center in Carderock, Maryland. Measurements were made in the test area and upstream of the test area.

16 TIDAL AND WAVE POWER↗

Commercial Building Energy Code Field Study: Data Collection Methodology and Protocol

In support of the U.S. Department of Energy’s Commercial Buildings Energy Code Field Study, this data collection methodology and protocol provides guidance on all aspects of undertaking a compliance study, from development of a sampling plan to recruitment to code requirements and compliance checks for each energy code measure specified to be collected. The protocol also includes a data collection form that captures all key information needed for analysis of commercial energy code compliance. This methodology was developed by the Institute for Market Transformation in coordination with Pacific Northwest National Laboratory (PNNL) and the U.S. Department of Energy Building Energy Codes Program with the objective of assisting states, jurisdictions, utilities and others as they seek to measure and demonstrate compliance rates with energy codes in commercial buildings, as well as to target areas for improvement through increased energy code compliance and broader energy-efficiency programs. It is also intended to facilitate a consistent and replicable approach to research studies of this type and establish a transparent data set representing baseline construction practices across the U.S.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial Building Energy Code Field Study: Data Collection Methodology and Protocol

In support of the U.S. Department of Energy’s Commercial Buildings Energy Code Field Study, this data collection methodology and protocol provides guidance on all aspects of undertaking a compliance study, from development of a sampling plan to recruitment to code requirements and compliance checks for each energy code measure specified to be collected. The protocol also includes a data collection form that captures all key information needed for analysis of commercial energy code compliance. This methodology was developed by the Institute for Market Transformation in coordination with Pacific Northwest National Laboratory (PNNL) and the U.S. Department of Energy Building Energy Codes Program with the objective of assisting states, jurisdictions, utilities and others as they seek to measure and demonstrate compliance rates with energy codes in commercial buildings, as well as to target areas for improvement through increased energy code compliance and broader energy-efficiency programs. It is also intended to facilitate a consistent and replicable approach to research studies of this type and establish a transparent data set representing baseline construction practices across the U.S.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗