Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Slow-light dynamics from electromagnetically-induced-transparency spectra

We show how slow-light pulse delays in realistic electromagnetically-induced-transparency (EIT) media can be determined directly from static transmission spectra. Using only the measured EIT linewidth and off-resonant transmission, the absolute delay of a slow-light pulse in an optically thick, power-broadened medium can be simply and accurately determined, while capturing more complex optical pumping behavior.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Passive decoy-state quantum key distribution with practical light sources

Decoy states have been proven to be a very useful method for significantly enhancing the performance of quantum key distribution systems with practical light sources. Although active modulation of the intensity of the laser pulses is an effective way of preparing decoy states in principle, in practice passive preparation might be desirable in some scenarios. Typical passive schemes involve parametric down-conversion. More recently, it has been shown that phase-randomized weak coherent pulses (WCP) can also be used for the same purpose [M. Curty et al., Opt. Lett. 34, 3238 (2009).] This proposal requires only linear optics together with a simple threshold photon detector, which shows the practical feasibility of the method. Most importantly, the resulting secret key rate is comparable to the one delivered by an active decoy-state setup with an infinite number of decoy settings. In this article we extend these results, now showing specifically the analysis for other practical scenarios with different light sources and photodetectors. In particular, we consider sources emitting thermal states, phase-randomized WCP, and strong coherent light in combination with several types of photodetectors, like, for instance, threshold photon detectors, photon number resolving detectors, and classical photodetectors. Our analysis includes as well the effect that detection inefficiencies and noise in the form of dark counts shown by current threshold detectors might have on the final secret key rate. Moreover, we provide estimations on the effects that statistical fluctuations due to a finite data size can have in practical implementations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Illusion optics in chaotic light

The time-reversal process provides the possibility to counteract the time evolution of a physical system. Recent research has shown that such a process can occur in the first-order field correlation of chaotic light and result in the spatial interference and phase-reversal diffraction in an unbalanced interferometer. Here we report experimental investigations on the invisibility cloak and illusion phenomena in chaotic light. In an unbalanced interferometer illuminated by thermal light, we have observed the cloak effect and the optical transformation of one object into another object. The experimental results can be understood by the phase-reversal diffraction, and they demonstrate the theoretical proposal of similar effects in complementary media.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electromagnetically induced transparency in paraffin-coated vapor cells

Antirelaxation coatings in atomic vapor cells allow ground-state coherent spin states to survive many collisions with the cell walls. This reduction in the ground-state decoherence rate gives rise to ultranarrow-bandwidth features in electromagnetically induced transparency (EIT) spectra, which can form the basis of, for example, long-time scale slow and stored light, sensitive magnetometers, and precise frequency standards. Here we study, both experimentally and theoretically, how Zeeman EIT contrast and width in paraffin-coated rubidium vapor cells are determined by cell and laser-beam geometry, laser intensity, and atomic density. Using a picture of Ramsey pulse sequences, where atoms alternately spend ''bright'' and ''dark'' time intervals inside and outside the laser beam, we explain the behavior of EIT features in coated cells, highlighting their unique characteristics and potential applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Interpretable and Efficient Interferometric Contrast in Scanning Transmission Electron Microscopy with a Diffraction-Grating Beam Splitter

Efficient imaging of biomolecules, 2D materials and electromagnetic fields depends on retrieval of the phase of transmitted electrons. We demonstrate a method to measure phase in a scanning transmission electron microscope using a nanofabricated diffraction grating to produce multiple probe beams. The measured phase is more interpretable than phase-contrast scanning transmission electron microscopy techniques without an off-axis reference wave, and the resolution could surpass that of off-axis electron holography. Here, we apply the technique to image nanoparticles, carbon sub- strates and electric fields. The contrast observed in experiments agrees well with contrast predicted in simulations.

36 MATERIALS SCIENCE↗

Local density of states, spectrum, and far-field interference of surface plasmon polaritons probed by cathodoluminescence

The surface plasmon polariton (SPP) field intensity in the vicinity of gratings patterned in an otherwise planar gold surface is spatially resolved using cathodoluminescence (CL). A detailed theoretical analysis is presented that successfully explains the measured CL signal based upon interference of transition radiation directly generated by electron impact and SPPs launched by the electron and outcoupled by the grating. The measured spectral dependence of the SPP yield per incoming electron is in excellent agreement with rigorous electromagnetic calculations. The CL emission is shown to be similar to that of a dipole oriented perpendicular to the surface and situated at the point of electron impact, which allows us to establish a solid connection between the CL signal and the photonic local density of states associated to the SPPs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Model-based determination of dielectric function by STEM low-loss EELS

Dielectric properties of materials are crucial in describing the electromagnetic response of materials. As devices are becoming considerably smaller than the optical wavelength, the conventional measuring methods based on optical response are limited by their spatial resolution. Electron energy loss spectroscopy performed in a scanning transmission electron microscope is a good alternative to obtain the dielectric properties with excellent spatial resolution. Due to the overlap of diffraction discs in scanning transmission electron microscopy, it is difficult to apply conventional experimental settings to suppress retardation losses. In this contribution, a relativistic dielectric model for the loss function is presented which is used in a model based optimization scheme to estimate the complex electric function of a material. The method is applied to experiments on bulk diamond and SrTiO{sub 3} and shows a good agreement with optical reference data when retardation effects are included. Application of this technique to nanoparticles is possible but several theoretical assumptions made in the model of the loss function are violated and interpretation becomes problematic.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Higher-spin structures in F 21 and Na 25

We investigated excited states in F-21 and Na-25 using the Be-9(C-14, pn gamma) reaction at 30, 35, and 45 MeV and the Be-9(O-18, pn gamma) reaction at 35 MeV. We also detected protons and identified in an E-Delta E telescope at 0 degrees in coincidence with one or more gamma radiations in the FSU Compton-suppressed Ge detector array. Many new levels and electromagnetic decays were observed, especially among the higher spin states. Angular distributions and mean lifetimes were measured wherever possible in both nuclei. The energy levels of the positive-parity states in the two nuclei agree rather well with shell model calculations using both the USDA and WBP interactions up to the highest spins observed of 13/2 h. Both a weak coupling approximation and shell model calculations using the WBP interaction generally reproduce the negative-parity states in F-21. Finally, the shell model calculations reproduce relatively well the measured M1 and E2 transitions in both nuclei, but overpredict the parity-changing E1 transitions in F-21, the only nucleus in which negative-parity states were observed in the present experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental demonstration of a displacement noise free interferometry scheme for gravitational wave detectors showing displacement noise reduction at low frequencies

This paper reports an experimental demonstration of partial displacement noise free laser interferometry in the gravitational wave detection band. The used detuned Fabry-Perot cavity allows the isolation of the mimicked gravitational wave signal from the displacement noise on the cavities input mirror. By properly combining the reflected and transmitted signals from the cavity a reduction of the displacement noise was achieved. Our results represent the first experimental demonstration of this recently proposed displacement noise free laser interferometry scheme. Overall, we show that the rejection ratio of the displacement noise to the gravitational wave signal was improved in the frequency range of 10 Hz to 10 kHz with a typical factor of {approx}60.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Molecular laser stabilization at low frequencies for the LISA mission

We have developed a 532 nm iodine stabilized laser system that may be suitable for the LISA mission (Laser Interferometer Space Antenna) or other future spaceborne missions. This system is based on an externally frequency-doubled Nd:YAG laser source and uses the molecular transfer spectroscopy technique for the frequency stabilization. This technique has been optimized for LISA: compactness (less than 1.1x1.1 m{sup 2}), vacuum compatibility, ease of use and initialization, minimization of the number of active components (acousto-optic modulators are both used for frequency shifting and phase modulating the pump beam). By locking on the a{sub 10} hyperfine component of the R(56)32-0 transition, we find an Allan standard deviation ({sigma}) of 3x10{sup -14} at 1 s and {sigma}<2x10{sup -14} for 20 s{<=}{tau}{<=}10{sup 3} s. In terms of linear spectral density, this roughly corresponds to a stability better than 30 Hz/{radical}(Hz) between 10{sup -2} and 1 Hz with a stability decrease close to 1/f below 10 mHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Testing parity-violating mechanisms with cosmic microwave background experiments

Chiral gravity and cosmological birefringence both provide physical mechanisms to produce parity-violating TB and EB correlations in the cosmic microwave background (CMB) temperature/polarization. Here, we study how well these two mechanisms can be distinguished if nonzero TB/EB correlations are found. To do so, we evaluate the correlation matrix, including new TB-EB covariances. We find that the effects of these two mechanisms on the CMB are highly orthogonal, and can thus be distinguished fairly well in the case of a high-signal-to-noise detection of TB/EB correlations. Appendix 2 evaluates the relative sensitivities of the BB, TB, and EB signals for detecting a chiral gravitational-wave background.

79 ASTRONOMY AND ASTROPHYSICS↗

Accuracy of estimation of parameters with LISA

We present the results of the estimation of parameters with LISA for nearly monochromatic gravitational waves in the low and high frequency regimes for the time-delay interferometry response. Angular resolution of the detector and the estimation errors of the signal's parameters in the high frequency regimes are calculated as functions of the position in the sky and as functions of the frequency. For the long-wavelength domain we give compact formulas for the estimation errors valid on a wide range of the parameter space.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation of Nonlinear Standing Waves Excited by Plasma-Series-Resonance-Enhanced Harmonics in Capacitive Discharges

We report the first experimental observation of nonlinear standing waves excited by plasma-series-resonance-enhanced harmonics in low pressure, very high frequency, parallel plate, capacitively coupled plasmas. Furthermore, spatial structures of the harmonics of the magnetic field, measured by a magnetic probe, are in very good agreement with simulations based on a nonlinear electromagnetics model. At relatively low pressure, the nonlinear sheath motion generates high-order harmonics that can be strongly enhanced near the series resonance frequencies. Satisfying certain conditions, such nonlinear harmonics induce radial standing waves, with voltage and current maxima on axis, resulting in center-high plasma density. Excitation of higher harmonics is suppressed at higher pressures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bulk properties of honeycomb lattices of superconducting microwave resonators

We have realized different honeycomb lattices for microwave photons in the 4 to 8 GHz band using superconducting spiral resonators. Each lattice comprises a few hundred sites. Two designs have been studied, one leading to two bands touching at the Dirac points and one where a gap opens at the Dirac points. Using a scanning laser technique to image the eigenmodes of this new type of photonic lattices, we are able to reconstruct their band structure. The measured bands are in excellent agreement with ab initio models that combine numerical simulations of the electromagnetic properties of the spiral resonator and analytical calculations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design and Analysis of a Mutual Inductance Level Sensor for Liquid Metals

Here, this article describes the design and analysis of an electromagnetic level sensor for use in high-temperature liquid metal systems. The mutual inductance level sensor (MILS) described in this work was fabricated using two single-conductor mineral insulated cables wrapped in a bifilar fashion around a stainless steel tube core and was housed in an isolating thimble that preserved the pressure boundary of the test vessel. Two sensor variations were fabricated that differ only in active length, 1016 and 1778 mm. Experimental data were collected using the 1016-mm sensor (MILS-MKII-040) that demonstrated a sensitivity of 9.2 μ V/mm in a room temperature testing stand that used solid aluminum as a surrogate for liquid metal. Experimental data were collected using the 1778-mm sensor (MILS-MKII-070) that demonstrated a sensitivity of 6.9 μ V/mm in the high-temperature (300 ° C) liquid sodium environment at the mechanisms engineering test loop (METL) of Argonne National Laboratory. The sensor performance was found to be repeatable over the course of several months, with roughly ±1% deviation from nominal output. Finite element models were developed in COMSOL Multiphysics that fully describe each test setup, and the models were validated using experimental data. The validated COMSOL models were used to perform an array of analyses that examined the performance of the sensor in differing environments. Maximizing the coil diameter inside the isolating thimble was found to maximize the signal and sensitivity of the sensor. An optimal operating frequency was found near 1000 Hz using both experimental data and COMSOL. The influence of a metallic thimble surrounding the sensor and a metallic sensor core was quantified and found to be negligible at the optimal operating frequency. The sensitivity of the sensor was quantified when monitoring the level of additional liquid metals. These include lead, lead-bismuth eutectic (LBE), sodium-potassium alloy (NaK), and lithium (in addition to sodium). The sensitivities were quantified using liquid metal properties at 350 ° C and 650 ° C. The geometry of the test stand model, all material properties used in the model, and the results are presented in a manner that allows the reader can replicate the model and perform additional analyses.

COMSOL↗

A Time-Domain Protection Approach for AC Transmission Systems With Grid-Forming Resources

Ac transmission protection must reliably detect, classify, and locate short-circuit faults from voltage and current measurements. At present, these functionalities, which have been classically engineered using phasors approaches, are being challenged by the dynamic behavior and fault-current limits of converter-based generation. This paper tackles these challenges by engineering a time-domain protection approach that leverages the classical Bergeron model in a new manner. Low- and high-impedance faults are detected and classified by ascertaining how well line voltage and current measurements match the Bergeron equations. Faults are located by posing a novel one-variable optimization problem, whereas voltage and current waveforms at the fault location are estimated by unveiling rigorous relationships. The proposed elements are secure against external faults, measurement errors, and variation of line parameters and sampling time. Furthermore, these advances are tested via electromagnetic transient simulations and are significant to satisfy IEEE and North American Electric Reliability Corporation requirements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Commissioning of the large-scale lead tungstate scintillating calorimeter

Here, we report on the installation and initial commissioning of a large-scale lead tungstate (PbWO4) scintillating crystal calorimeter developed for high-rate photon detection and precise energy measurement. The calorimeter comprises 1596 high-granularity, high-resolution scintillating crystals optimized for electromagnetic-shower detection over a wide energy range. Scintillation light from each crystal is read out by Hamamatsu R4125 photomultiplier tubes equipped with a custom voltage divider and front-end amplifier to ensure stable gain at high rates. All calorimeter modules were fabricated and characterized using a light-emitting diode–based optical test system prior to installation to verify uniformity and photodetector performance. After installation, the electromagnetic calorimeter was fully integrated into the experiment data acquisition and energy-based trigger systems. The optical response of the modules was equalized using the light-monitoring system, cosmic-ray muons, and photons from Compton-scattering events. Commissioning results demonstrate a reliably calibrated optical response and stable detector performance during the first run. These results validate the calorimeter design and commissioning methodology for large-scale scintillator-based photonic instrumentation.

Analog to digital converters↗