Two-dimensional manual control systems with separated displays.
Model for two-dimensional manual control systems with separated displays
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Model for two-dimensional manual control systems with separated displays
Muscle action potential and hand switch disjunctive reaction times to visual, auditory, and combined visual-auditory displays
Operators can be poor monitors of automation if they are engaged concurrently in other tasks. However, in previous studies of this phenomenon the automated task was always presented in the periphery, away from the primary manual tasks that were centrally displayed. In this study we examined whether centrally locating an automated task would boost monitoring performance during a flight-simulation task consisting of system monitoring, tracking and fuel resource management sub-tasks. Twelve nonpilot subjects were required to perform the tracking and fuel management tasks manually while watching the automated system monitoring task for occasional failures. The automation reliability was constant at 87.5% for six subjects and variable (alternating between 87.5% and 56.25%) for the other six subjects. Each subject completed four 30 min sessions over a period of 2 days. In each automation reliability condition the automation routine was disabled for the last 20 min of the fourth session in order to simulate catastrophic automation failure (0 % reliability). Monitoring for automation failure was inefficient when automation reliability was constant but not when it varied over time, replicating previous results. Furthermore, there was no evidence of resource or speed accuracy trade-off between tasks. Thus, automation-induced failures of monitoring cannot be prevented by centrally locating the automated task.
A new technology developed at JPL using low absorption color filters with polarization and color recycle system, is able to enhance efficiency of a single panel liquid crytal display (LCD) projector to the same efficiency of a 3 panel LCD projector.
Advantages of using visual programming to create, modify, test and display a telemetry stream are presented. Commercial visual programming software is being used to test new algorithms as part of the ground support for the Galileo spacecraft Test Bed.
This paper describes the software developed at JPL for displaying calibrated SAR images and analyzing them on the Macintosh.
This internship provides the opportunity to support the creation and use of Firing Room Displays and Firing Room Applications that use an abstraction layer called the Application Control Language (ACL). Required training included video watching, reading assignments, face-to-face instruction and job shadowing other Firing Room software developers as they completed their daily duties. During the training period various computer and access rights needed for creating the applications were obtained. The specific ground subsystems supported are the Cryogenics Subsystems, Liquid Hydrogen (LH2) and Liquid Oxygen (LO2). The cryogenics team is given the task of finding the best way to handle these very volatile liquids that are used to fuel the Space Launch System (SLS) and the Orion flight vehicles safely.
The role of attentional bias to a specific form of information, e.g., visual versus aural instructions, was evaluated to address the issue of attentional fixation (i.e., "cognitive tunneling") in the flight deck. A method of mitigating attentional tunneling using a spatial auditory display was evaluated in the presence and absence of a biasing factor. Data were gathered for participant recognition, accuracy and response times to aural and visual instructions under different conditions of distractor stimuli. Results showed a significant main effect for target acquisition with the use of spatial audio techniques. No significant main effects or interactions were found for target acquisition timing. Target acquisition was not affected by a "gaming score" biasing factor associated with the distractor tasks.
This 8-minute oral presentation will present methods for “linearizing” a display to enable the delivery of precisely controlled stimuli in vision experiments.
This paper reviews the potential role of tactile cueing in multimodal displays that will need to be developed to enable Extravehicular Activity (EVA) and telerobotic exploration for both Moon and Mars missions. Specific missions to be accomplished during EVA surface and space operations will include construction and assembly, surface and geologic exploration, and excavation for protective shelter from radiation and significant solar particle events. EVA crews have limited time, resources, mobility, visibility and dexterity, and activities take place in a perceptually impoverished environment. Limitations include a loss of spatial reference frame leading to spatial disorientation, a loss of information normally provided by the auditory and somato-sensory systems, and a restricted field of view. In addition, in non-surface operations crew must be able to navigate and operate in a fully six degree of freedom (DoF) environment. Fatigue resulting from suited EVA tasks will also critically affect performance and safety. In order to mitigate these factors, it is important that crews be well trained prior to executing actual missions. There is a critical need to design multimodal interfaces to optimize performance under these conditions for both training and actual operations. Because of the high level of complexity of the EVA environment on the one hand, and the “sensory restrictions” on the other, it makes sense to envisage enhancements to the astronauts’ visual environment. Such an enriched environment may include virtual auditory as well as tactile inputs.
Human factors in space navigation displays
Design for a modular display panel is based on a cross-shaped corner connector and wooden lattice bars. The bars are fitted into the arms of the metal connector and a pocket slot holds a modular-size panel.
Effects of manual attack-display noise filtering on pilot tracking performance
To compute the heartbeat rate from the waveform output of an electrocardiogram, a digital cardiometer with solid state circuit elements has been developed. This computes the beat every 15 seconds and visually presents the data on numerical display tubes.
Pilot performance during aircraft blind landings using closed circuit television display as control device
Explorer xvii real time pcm telemetry data processing and display test stand
Photographic negative placed between two plastic sheets and back-lighted in selected areas prepares illuminated multicolored display panels. The device is inexpensive, easily changed, and quickly fabricated.
Pilot cockpit display design and viewing system