Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Diodes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Characteristics of the Single-Longitudinal-Mode Planar-Waveguide External Cavity Diode Laser at 1064 nm

We describe the characteristics of the planar-waveguide external cavity diode laser (PW-ECL). To the best of our knowledge, it is the first butterfly-packaged 1064 nm semiconductor laser that is stable enough to be locked to an external frequency reference. We evaluated its performance from the viewpoint of precision experiments. Using a hyperfine absorption line of iodine, we suppressed its frequency noise by a factor of up to 104 at 10 mHz. The PWECL's compactness and low cost make it a candidate to replace traditional Nd:YAG nonplanar ring oscillators and fiber lasers in applications that require a single longitudinal mode.

planar-waveguide↗

Highly Sensitive Tunable Diode Laser Spectrometers for In Situ Planetary Exploration

This paper describes highly sensitive tunable diode laser spectrometers suitable for in situ planetary exploration. The technology developed at JPL is based on wavelength modulated cavity enhanced absorption spectroscopy. It is capable of sensitively detecting chemical signatures of life through the abundance of biogenic molecules and their isotopic composition, and chemicals such as water necessary for habitats of life. The technology would be suitable for searching for biomarkers, extinct life, potential habitats of extant life, and signatures of ancient climates on Mars; and for detecting biomarkers, prebiotic chemicals and habitats of life in the outer Solar System. It would be useful for prospecting for water on the Moon and asteroids, and characterizing its isotopic composition. Deployment on the Moon could provide ground truth to the recent remote measurements and help to uncover precious records of the early bombardment history of the inner Solar System buried at the shadowed poles, and elucidate the mechanism for the generation of near-surface water in the illuminated regions. The technology would also be useful for detecting other volatile molecules in planetary atmospheres and subsurface reservoirs, isotopic characterization of planetary materials, and searching for signatures of extinct life preserved in solid matrices.

Vasudev, Ram↗

Theoretical Current-Voltage Curve in Low-Pressure Cesium Diode for Electron-Rich Emission

Although considerable interest has been shown in the space-charge analysis of low-pressure (collisionless case) thermionic diodes, there is a conspicuous lack in the presentation of results in a way that allows direct comparison with experiment. The current-voltage curve of this report was, therefore, computed for a typical case within the realm of experimental interest. The model employed in this computation is shown in Fig. 1 and is defined by the limiting potential distributions [curves (a) and (b)]. Curve (a) represents the potential V as a monotonic function of position with a slope of zero at the anode; curve (b) is similarly monotonic with a slope of zero at the cathode. It is assumed that by a continuous variation of the anode voltage, the potential distributions vary continuously from one limiting form to the other. Although solutions for infinitely spaced electrodes show that spatically oscillatory potential distributions may exist, they have been neglected in this computation.

Coldstein, C. M.↗

Space Launch System Base Heating Test: Tunable Diode Laser Absorption Spectroscopy

This paper describes the Tunable Diode Laser Absorption Spectroscopy (TDLAS) measurement of several water transitions that were interrogated during a hot-fire testing of the Space Launch Systems (SLS) sub-scale vehicle installed in LENS II. The temperature of the recirculating gas flow over the base plate was found to increase with altitude and is consistent with CFD results. It was also observed that the gas above the base plate has significant velocity along the optical path of the sensor at the higher altitudes. The line-by-line analysis of the H2O absorption features must include the effects of the Doppler shift phenomena particularly at high altitude. The TDLAS experimental measurements and the analysis procedure which incorporates the velocity dependent flow will be described.

Parker, Ron↗

Space Launch System Base Heating Test: Tunable Diode Laser Absorption Spectroscopy

This paper describes the Tunable Diode Laser Absorption Spectroscopy (TDLAS) measurement of several water transitions that were interrogated during a hot-fire testing of the Space Launch Systems (SLS) sub-scale vehicle installed in LENS II. The temperature of the recirculating gas flow over the base plate was found to increase with altitude and is consistent with CFD results. It was also observed that the gas above the base plate has significant velocity along the optical path of the sensor at the higher altitudes. The line-by-line analysis of the H2O absorption features must include the effects of the Doppler shift phenomena particularly at high altitude. The TDLAS experimental measurements and the analysis procedure which incorporates the velocity dependent flow will be described.

Parker, Ron↗

Development and Preliminary Tests of an Open-Path Airborne Diode Laser Absorption Instrument for Carbon Dioxide

Carbon dioxide (CO2) is well known for its importance as an atmospheric greenhouse gas, with many sources and sinks around the globe. Understanding the fluxes of carbon into and out of the atmosphere is a complex and daunting challenge. One tool applied by scientists to measure the vertical flux of CO2 near the surface uses the eddy covariance technique, most often from towers but also from aircraft flying specific patterns over the study area. In this technique, variations of constituents of interest are correlated with fluctuations in the local vertical wind velocity. Measurement requirements are stringent, particularly with regard to precision, sensitivity to small changes, and temporal sampling rate. In addition, many aircraft have limited payload capability, so instrument size, weight, and power consumption are also important considerations. We report on the development and preliminary application of an airborne sensor for the measurement of atmospheric CO2. The instrument, modeled on the successful DLH (Diode Laser Hygrometer) series of instruments, has been tested in the laboratory and on the NASA DC-8 aircraft. Performance parameters such as accuracy, precision, sensitivity, specificity, and temporal response are discussed in the context of typical atmospheric variability and suitability for flux measurement applications. On-aircraft, in-flight data have been obtained and are discussed as well. Performance of the instrument has been promising, and continued flight testing is planned during 2016.

Diskin, Glenn S.↗

A theoretical analysis of steady-state photocurrents in simple silicon diodes.

A theoretical analysis solves for the steady-state photocurrents produced by a given photogeneration rate function with negligible recombination in simple silicon diodes, consisting of a uniformly doped quasi-neutral region (called "substrate" below) between a p-n junction depletion region (DR) and an ohmic contact (electrode). Special attention is given to conditions that produce "funneling" (a term used by the single-event-effects community) under steady-state conditions. Funneling occurs when carriers are generated so fast that the DR becomes flooded and partially or completely collapses. Some or nearly all of the applied voltage plus built-in potential normally across the DR is now across the substrate. This substrate voltage drop affects substrate currents. The steady-state problem can provide some qualitative insights into the more difficult transient problem. Chapter 6 discusses some similarities between the steady-state and transient problems...

Edmonds, Larry↗

Comparison of Single-Event Transients in an Epitaxial Silicon Diode Resulting from Heavy Ion-, Focused X-Ray-, and Pulsed Laser-Induced Charge Generation

Heavy ion, focused X-ray, pulsed laser single event transient experiments are performed on a silicon epitaxial diode. Collected charge, transient rise times, and transient fall times are calculated and compared between the different sources. The transient shape characteristics depend on the source (ion, X-ray, or laser), even when similar amounts of charge are generated. The observed differences are examined and explained in terms of basic charge collection mechanisms.

Heavy ions↗

Angle Dependence of Focused X-Ray-Induced Single Event Transients in an Epitaxial Silicon Diode

Focused X-Ray single event transient (SET) experiments are performed at small angles on an epitaxial silicon diode at two reverse bias conditions. For both biases, the collected charge and peak current results follow the cosine law, while the transient fall time remains independent of incident angle. This demonstrates that only the amount of charge being generated is affected by angle and not the fundamental device response.

Heavy ions↗

Angle Dependence of Focused X-Ray-Induced Single Event Transients in an Epitaxial Silicon Diode

Focused X-Ray single event transient (SET) experiments are performed at small angles on an epitaxial silicon diode at two reverse bias conditions. For both biases, the collected charge and peak current results follow the cosine law, while the transient fall time remains independent of incident angle. This demonstrates that only the amount of charge being generated is affected by angle and not the fundamental device response for these relatively large devices.

Focused X-ray↗

Mechanisms of Heavy Ion-, Focused X-Ray-, and Pulsed Laser-Induced Single Event Transients in an Epitaxial Silicon Diode

Heavy ion-, focused X ray-, and pulsed laser induced single event effects in an epitaxial silicon diode were simulated using Sentaurus Technology Computer Aided Design (TCAD). The variation of the potential with time in simulation agrees with previous experimental data, which suggests that the different radiation sources result in different amounts of potential modulation. The charge generation spatial profile strongly affects the potential modulation. The longitudinal range and starting location of generated charge most strongly impacts the amount of potential modulation, while the radial width has a slight effect, and the temporal duration of charge injection has negligible impact on potential modulation

Kaitlyn L. Ryder↗

Technology Demonstration Mission (TDM) evolvable Cryogenics (eCryo) Project Structural Heat Intercept, Insulation and Vibration Evaluation Rig (SHIIVER) Diode Rake Assembly and Installation

NASA designed, assembled and installed a temperature diode rake into the SHIIVER test article for use of measuring liquid and gaseous hydrogen temperatures. Several special steps were taken to ensure that fluid temperatures were measured as opposed to structural temperatures. This document outlines design practices and methodologies that have become standard practice at Glenn Research Center to ensure the measurement of fluid temperatures for cryogenic systems research.

Cryogenic Fluid Management↗