Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Mixing efficiency in heterodyne systems

How the spatial distributions of the signal and local oscillator fields affect the heterodyne signal to noise ratio is examined for both a single detector and an array of detectors. For an array, the distribution of gain among the intermediate frequency (i.f.) amplifiers is included. The emphasis is on understanding why the distributions are important and what is the key to maximizing the signal to noise ratio in any system. It is shown that for a single detector, the highest signal to noise ratio is obtained with a local oscillator (LO) distribution the same as that of the signal. For an array, the product of the i.f. gain times the LO field at each detector has the same distribution as that of the signal field.

Fink, D.↗

BICEP Array: 150 GHz Detector Module Development

The Background Imaging of Cosmic Extragalactic Polarization (BICEP)/Keck (BK) collaboration is currently leading the quest for the highest-sensitivity measurements of the polarized cosmic microwave background (CMB) anisotropies on a degree scale with a series of cryogenic telescopes, of which BICEP Array (BA) is the latest Stage-3 upgrade with a total of ~ 32,000 detectors. The instrument comprises 4 receivers spanning 30–270 GHz, with the low-frequency 30/40 GHz deployed to the South Pole Station in late 2019. The full complement of receivers is forecast to set the most stringent constraints on the tensor-to-scalar ratio r. Building on these advances, the overarching small-aperture telescope concept is already being used as the reference for further Stage-4 experiment design. This paper describes the development of the BICEP Array 150 GHz detector module and its fabrication requirements, with highlights on the high-density time division multiplexing (TDM) design of the cryogenic circuit boards. The low-impedance wiring required between the detectors and the frst stage of superconducting quantum interference device amplifers is crucial to maintaining a stable bias current on the detectors. Here, a novel multilayer FR4 Printed Circuit Board with superconducting traces, capable of reading out up to 648 detectors, is detailed along with its validation tests. An ultra-high-density TDM detector module concept we developed for a CMB-S4-like experiment that allows up to 1920 detectors to be read out is also presented. TDM has been chosen as the detector readout technology for the Cosmic Microwave Background Stage-4 (CMB-S4) experiment based on its proven low-noise performance, predictable costs, and overall maturity of the architecture. The heritage for TDM is rooted in mm- and sub-mm-wave experiments dating back 20 years and has since evolved to support a multiplexing factor of 64x in Stage-3 experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Imaging at soft X-ray wavelengths with high-gain microchannel plate detector systems

Multianode microchannel array (MAMA) detector systems with formats of 256 x 1024 pixels and active areas of 6 x 26 mm are now under evaluation at visible, UV and soft X-ray wavelengths. Very-large-format versions of the MAMA detectors with formats of 2048 x 2048 pixels and active areas of 52 x 52 mm are under development for use in the NASA Goddard Space Telescope Imaging Spectrograph (STIS). Open-structure versions of these detectors with Cs I photocathodes can provide a high-resolution imaging capability at EUV and soft X-ray wavelengths and can deliver a maximum count rate from each array in excess of 10 to the 6th counts/s. In addition, these detector systems have the unique capability to determine the arrival time of a detected photon to an accuracy of 100 ns or better. The construction, mode of operation, and performance characteristics of the MAMA detectors are described, and the program for the development of the very-large-format detectors is outlined.

Timothy, J. Gethyn↗

Development of a large array of Silicon Drift Detectors for high-rate synchrotron fluorescence spectroscopy

An array of small-area Silicon Drift Detectors (SDD), named Hera, has been developed at Brookhaven National Laboratory (BNL) in the past few years. Its primary application is high-rate spectroscopy at synchrotrons. Each SDD pixel is a 1 mm × 1 mm square to match the footprint of the original diode-based pixel detector called Maia, which was developed for the same application. The replacement of the diode with an SDD allows for better energy resolution at short shaping times and an increased stability of the detector. 32, 96, and 384-channel arrays were designed and fabricated and achieved a Full Width Half Maximum (FWHM) as low as 176 eV at 5.9 keV with peaking time of 1 μs at -13°C. The sensor design, simulation, fabrication, its readout system, and its spectroscopic performance are reported.

47 OTHER INSTRUMENTATION↗

(abstract) 9 (micro)m Cutoff 640x480 Quantum Well Infrared Photodetector (QWIP) Focal Plane Array Camera

Long wavelength infrared (LWIR) detectors, 8 (micro)m to 12 (micro)m, are of great interest for a variety of ground-based and space-borne applications. These applications have placed stringent requirements on the performance of the infrared detectors and arrays including high detectivity, low dark current, uniformity, radiation hardness, and low power dissipation. I will discuss the development and progress of GaAs based long-wavelength quantum well infrared photodetectors (QWIPs) to meet those stringent requirements and the demonstration of a 9 (micro)m cutoff 640x480 QUIP focal plane array camera. The noise equivalent temperature difference of the focal plane array is 25 mK at 300 K background and the operating temperature is 70 K.

long wavelength infrared detectors LWIR detector a↗

Demonstration of o-Ps detection with a cylindrical array of NaI detectors

Ortho-positronium (o-Ps) is a bound state of an electron and positron that can provide a means of searching for new physics. We searched and identified o-Ps in our cylindrical array of NaI(Tl) scintillators, developing a technique for tagging on o-Ps with any one of the 24 bars in the array. With high angular efficiency and this new technique, such an experimental setup could be used in a fundamental symmetries search. In particular, we explore the possibility of using such a setup with a search for CP- or CPT-violation in o-Ps.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Systems and methods for point-of-care positron emission tomography

A positron emission tomography (PET) system is provided. The system includes a first detector panel including a first array of detectors, a second detector panel including a second array of detectors, said second detector panel being moveable relative to a point between the first detector panel and the second detector panel, a tracking system configured to detect a position of said second detector panel relative to the first detector panel while imaging a subject, a computing device in communication with the first detector panel, the second detector panel, and the tracking system, the computing device configured to receive coincidence data from the first and second detector panels, receive position data from the tracking system, wherein each coincidence datum of the received coincidence data is associated with a unique position datum of the received position data, and reconstruct a plurality of images based on the received coincidence data and the received position data.

Tai, Yuan-Chuan↗

Fabrication of an Absorber-Coupled MKID Detector and Readout for Sub-Millimeter and Far-Infrared Astronomy

We have fabricated absorber-coupled microwave kinetic inductance detector (MKID) arrays for sub-millimeter and farinfrared astronomy. Each detector array is comprised of lambda/2 stepped impedance resonators, a 1.5μm thick silicon membrane, and 380μm thick silicon walls. The resonators consist of parallel plate aluminum transmission lines coupled to low impedance Nb microstrip traces of variable length, which set the resonant frequency of each resonator. This allows for multiplexed microwave readout and, consequently, good spatial discrimination between pixels in the array. The Al transmission lines simultaneously act to absorb optical power and are designed to have a surface impedance and filling fraction so as to match the impedance of free space. Our novel fabrication techniques demonstrate high fabrication yield of MKID arrays on large single crystal membranes and sub-micron front-to-back alignment of the microstrip circuit.

far-infrared↗

Recent developments in materials and detectors for the infrared; Proceedings of the Meeting, Cannes, France, November 25, 26, 1985

The present conference on advancements in IR-sensitive materials and detector technologies employing them gives attention to thermal detectors, focal plane array processing detectors, novel detector designs, general properties of IR optics materials, and preparation methods for such materials. Specific topics encompass the fabrication of InSb MIS structures prepared by photochemical vapor deposition, IR heterodyne detectors employing cadmium mercury telluride, low microphony pyroelectric arrays, IR detection based on minority carrier extrusion, longwave reststrahl in IR crystals, and molecular beam techniques for optical thin film fabrication.

Morten, F. D.↗

Development of the MAMA Detectors for the Hubble Space Telescope Imaging Spectrograph

The development of the Multi-Anode Microchannel Array (MAMA) detector systems started in the early 1970's in order to produce multi-element detector arrays for use in spectrographs for solar studies from the Skylab-B mission. Development of the MAMA detectors for spectrographs on the Hubble Space Telescope (HST) began in the late 1970's, and reached its culmination with the successful installation of the Space Telescope Imaging Spectrograph (STIS) on the second HST servicing mission (STS-82 launched 11 February 1997). Under NASA Contract NAS5-29389 from December 1986 through June 1994 we supported the development of the MAMA detectors for STIS, including complementary sounding rocket and ground-based research programs. This final report describes the results of the MAMA detector development program for STIS.

Timothy, J. Gethyn↗

Quantum Well and Quantum Dot Modeling for Advanced Infrared Detectors and Focal Plane Arrays

This viewgraph presentation reviews the modeling of Quantum Well Infrared Detectors (QWIP) and Quantum Dot Infrared Detectors (QDIP) in the development of Focal Plane Arrays (FPA). The QWIP Detector being developed is a dual band detector. It is capable of running on two bands Long-Wave Infrared (LWIR) and Medium Wavelength Infrared (MWIR). The same large-format dual-band FPA technology can be applied to Quantum Dot Infrared Photodetector (QDIP) with no modification, once QDIP exceeds QWIP in single device performance. Details of the devices are reviewed.

quantum well↗

Fabrication of an Absorber-Coupled MKID Detector and Readout for Sub-Millimeter and Far-Infrared Astronomy

We have fabricated absorber-coupled microwave kinetic inductance detector (MKID) arrays for sub-millimeter and far-infrared astronomy. Each detector array is comprised of lambda/2 stepped impedance resonators, a 1.5 micrometer thick silicon membrane, and 380 micrometer thick silicon walls. The resonators consist of parallel plate aluminum transmission lines coupled to low impedance Nb microstrip traces of variable length, which set the resonant frequency of each resonator. This allows for multiplexed microwave readout and, consequently, good spatial discrimination between pixels in the array. The Al transmission lines simultaneously act to absorb optical power and are designed to have a surface impedance and filling fraction so as to match the impedance of free space. Our novel fabrication techniques demonstrate high fabrication yield of MKID arrays on large single crystal membranes and sub-micron front-to-back alignment of the microstrip circuit.

Brown, Ari-David↗

A plan for the characterization, calibration, and evaluation of LAPR-2

A new airborne Linear Array Pushbroom Radiometer (LAPR-II) was built. LAPR-II will use linear arrays of silicon detectors to acquire four channels of digital image data for spectral bands within the visible and near infrared portions of the spectrum (0.4 - 1.0 micrometers). The data will be quantized to 10 bits, and spectral filters for each channel will be changeable in flight. The instrument will initially be flown aboard a NASA/Wallops' aircraft, and off nadir pointing of LAPR-II will be possible. Together, the instrument and its platform will provide a flexible readily available source of digital image data for scientific experiments. If LAPR-II is to serve as a precise scientific instrument, the instrument's characteristics must be quantitatively described and the data must be calibrated with respect to absolute radiometric units. The LAPR-II is described and the work required to characterize the instrument's spectral response, radiometric response, and spatial resolution and to calibrate the response from the many detectors per array is outlined.

Ilrons, J. R.↗

LDEF active optical system components experiment

A preliminary report on the Active Optical System Components Experiment is presented. This experiment contained 136 components in a six-inch deep tray including lasers, infrared detectors and arrays, ultraviolet light detectors, light-emitting diodes, a light modulator, flash lamps, optical filters, glasses, and samples of surface finishes. The experimental results for those component characteristics appear as much related to the passage of time as to the effects of the space environment, but organic materials and extreme-infrared reflectivity of black paints show unexpected changes.

Blue, M. D.↗

LDEF active optical system components experiment

A preliminary report on the Active Optical System Components Experiment is presented. This experiment contained 136 components in a six inch deep tray including lasers, infrared detectors and arrays, ultraviolet light detectors, light-emitting diodes, a light modulator, flash lamps, optical filters, glasses, and samples of surface finishes. Thermal, mechanical, and structural considerations leading to the design of the tray hardware are discussed. In general, changes in the retested component characteristics appear as much related to the passage of time as to the effects of the space environment, but organic materials, multilayer optical interference filters, and extreme-infrared reflectivity of black paints show unexpected changes.

M D Blue↗

System Design and Implementation of the Detector Assembly of the Astro-H Soft X-Ray Spectrometer

The soft x-ray spectrometer (SXS) onboard Astro-H presents to the science community unprecedented capability (less than 7 eV at 6 keV) for high-resolution spectral measurements in the range of 0.5-12 keV to study extended celestial sources. At the heart of this SXS is the x-ray calorimeter spectrometer (XCS) where detectors (calorimeter array and anticoincidence detector) operate at 50 mK, the bias circuit operates at nominal 1.3 K, and the first stage amplifiers operateat 130 K, all within a nominal 20 cm envelope. The design of the detector assembly in this XCS originates from the Astro-E x-ray spectrometer (XRS) and lessons learned from Astro-E and Suzaku. After the production of our engineering model, additional changes were made in order to improve our flight assembly process for better reliability and overall performance. In this poster, we present the final design and implementation of the flight detector assembly, show comparison of parameters and performance to Suzakus XRS, and list susceptibilities to other subsystems as well as our lessons learned.

soft x-ray spectrometer↗