Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Investigation of sCVD diamond detectors for low energy heavy-ion reactions

Here the performance characteristics of single-crystalline diamond detectors at varying rates of heavy-ions below 50 MeV/u have been investigated. When tested with a 228 Th source, the energy resolution of these detectors is better than 1.0% FWHM for 8.8 MeV α-particles. With a slight reduction in the energy resolution, simultaneous timing resolution of 314 ps has been achieved. Isotopic resolution has been achieved up to magnesium using a diamond telescope at low rates with a 20 MeV/u 20 Ne + 12 C reaction. At moderate rates of direct 7.5 MeV/u 78 Kr, polarization effects are observed, though this effect can be diminished by increasing the applied voltage on the detector up to a limit. After an accumulated dose of 6.9 × 10 8 direct 78 Kr particles transmitting through the detector, a degradation in the energy resolution of the 8.8 MeV peak from 1.6% to 5.3% is observed, indicating that permanent damage has been done to the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High event rate analysis technique for the dual-axis duo-lateral position-sensitive silicon detectors of FAUST

The dual-axis duo-lateral (DADL) position-sensitive silicon detector was developed to obtain precise position and energy information for detected charged particles. The Forward Array Using Silicon Technology (FAUST) is currently equipped with 68 DADL detectors backed by CsI(Tl) scintillators for the study of charged particle correlations in heavy-ion collisions where precise position and energy information is essential. When conventional signal processing electronics were used for the DADL detectors, a position dependence of the measured energy as well as distortions in the calculated particle positions were observed. In previous work, waveforms from the detector after preamplification were studied to better understand the features that give rise to these distortions; therein, a waveform analysis technique was developed to improve the energy resolution and linearity in position reconstruction. However, the reading and writing of waveforms for an entire detector array limits data collection rates and adds significant burden in data storage and analysis speed. In this work, the integrators of a Struck SIS3316 ADC were utilized to process 228 Th source data to develop and optimize a new analysis method that captures the benefits of the waveform analysis technique while circumventing the waveform writing requirement. This integrator method – capable of 59 keV (FWHM) energy resolution – was used in the collection of 35 MeV/nucleon 28 Si + 12 C collision data using FAUST to investigate exotic decays of highly excited highly deformed nuclei. In this data, a position resolution of 0.4 mm (FWHM) was obtained for 25 MeV α-particles; for α-particles near this energy that originate from 8 Be ground state decays, a 8 Be ground state width of 30 keV (FWHM) was obtained. The impact of the energy-dependent DADL position resolution emergent from electronic noise on the quality of excited state measurement was modeled and compared to the experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Capability Demonstration of a 3D CdZnTe Detector on a High-Altitude Balloon Flight

In collaboration between the University of Michigan and Los Alamos National Laboratory, a 3D position-sensing CdZnTe (CZT) detector prototype was built and integrated into a high-altitude balloon platform to evaluate its performance in a space-like mixed-radiation environment. The detector prototype, Orion Eagle, was designed to operate in near-vacuum environments without any temperature regulation. Orion Eagle was hand-launched from NASA’s Columbia Scientific Balloon Facility (CSBF) at Fort Sumner, NM on September 26, 2021, and successfully operated throughout a 9-hour flight, which reached 38.5 km in altitude. The flight met its objectives, successfully detecting atmospheric gamma rays and galactic cosmic rays, and raising the Technical Readiness Level from 4 to 6 for large-volume 3D CZT detector technology for space applications. Ionization tracks produced by charged particles create spatial signatures in the detector that are distinguishable from discrete gamma-ray interactions. Therefore, the 3D position-sensing capabilities using pixelated electrodes on a CZT detector can help enable discrimination of background charged particles from gamma-ray events without an anticoincidence shield. The potential for background rejection capability, ambient-temperature operation, gamma-ray coded-aperture and Compton imaging, and near High Purity Germanium (HPGe) energy resolution motivate the use of large-volume 3D CZT imaging spectrometers in future space missions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstrating imaging plate detector stacks for proton radiography using exploding pusher capsules

A new detector design has been fielded on the Omega-60 laser facility using a D 3 He backlighter capsule to radiograph a magnetized experiment. D 3 He capsules produce a low flux (~ 10 8 total yield in 4π) of protons requiring detectors with close-to single-particle sensitivity to be employed. The new detector stack consisted of both imaging plate (IP) and CR-39 to detect 14.7 MeV protons where, historically, only CR-39 has been used. IP is sensitive to significant contributions in signal from both x-rays and protons so additional filtering has to be added to attenuate the x-rays. Here, the signals and features observed from a single shot are detected by both IP and CR-39, giving confirmation that it is protons creating the signatures on the IP. Measurements of PSL/pixel are used to calculate approximate on-shot proton yields and agree with commonly measured yields. A second IP is used at the rear of the stack to measure, and subsequently remove, a background signal. The spatial resolution at the IP is limited, primarily, by a range of proton energies with varying deflections being recorded at the detector, causing potential ‘blurring’ of features. We find for this setup that the blurring effect is less than the smallest identifiable features observed at the detector, and therefore of minimal impact. A large benefit to this new stack design is that IP can be scanned and processed on much faster timescales than CR-39 allowing for prompt shot feedback. Future designs and modifications to the stack design fielded on this experiment could help improve the contrast of the radiograph on IP, as well as detecting protons produced at alternative energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The design and construction of the Chips water Cherenkov neutrino detector

Chips (CHerenkov detectors In mine PitS) was a prototype large-scale water Cherenkov detector located in northern Minnesota. The main aim of the R&D project was to demonstrate that construction costs of neutrino oscillation detectors could be reduced by at least an order of magnitude compared to other equivalent experiments. This article presents design features of the Chips detector along with details of the implementation and deployment of the prototype. While issues during and after the deployment of the detector prevented data taking, a number of key concepts and designs were successfully demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of the ECCE detector for the Electron Ion Collider

The EIC Comprehensive Chromodynamics Experiment (ECCE) detector has been designed to address the full scope of the proposed Electron Ion Collider (EIC) physics program as presented by the National Academy of Science and provide a deeper understanding of the quark-gluon structure of matter. To accomplish this, the ECCE detector offers nearly acceptance and energy coverage along with excellent tracking and particle identification. The ECCE detector was designed to be built within the budget envelope set out by the EIC project while simultaneously managing cost and schedule risks. Finally, this detector concept has been selected to be the basis for the EIC project detector.

47 OTHER INSTRUMENTATION↗

Performance characterization of 5×5×12 mm 3 virtual Frisch-grid TlBr detectors

Thallium bromide (TlBr) is a promising material for semiconductor gamma-ray detectors due to its high atomic number (Tl = 81, Br = 35), high density (7.56 g/cm 3 ), and relatively low melting point (460 °C). These properties give TlBr several competitive features, including high detection efficiency, good energy resolution, and lower fabrication costs, making it suitable for applications requiring compact, highly sensitive gamma-ray detection systems. Recent developments of TlBr detectors have progressed toward thicker crystals, up to 10–20 mm, configured as pixelated or virtual Frisch-grid (VFG) devices with volumes >1 cm 3 . Despite these advances, challenges remain in practical implementation, including material and fabrication issues that affect energy resolution, device stability, performance, and longevity. These challenges are similar to those faced by HgI 2 and lead-halide perovskite detectors. Here, this study presents results from characterizing over 100 position-sensitive 5×5×12 mm 3 virtual Frisch-grid detectors fabricated by Radiation Monitoring Devices Inc. For a prototype Radioisotope Identification Device (RIID). The work identified factors limiting the performance and longevity of TlBr detectors, including stochastic response variations that limit the energy resolution to 2–3 % (at 662 keV) for most devices, performance degradation associated with defect decoration, and contact delamination. Addressing these issues advances the use of TlBr and similar materials for reliable, high-resolution gamma-ray spectroscopy.

47 OTHER INSTRUMENTATION↗

Impact of detector simulation in particle physics collider experiments

Through the last three decades, precise simulation of the interactions of particles with matter and modeling of detector geometries has proven to be of critical importance to the success of the international high-energy physics experimental programs. For example, the detailed detector modeling and accurate physics of the Geant4-based simulation software of the CMS and ATLAS particle physics experiments at the European Center of Nuclear Research (CERN) Large Hadron Collider (LHC) was a determinant factor for these collaborations to deliver physics results of outstanding quality faster than any hadron collider experiment ever before. This review article highlights the impact of detector simulation on particle physics collider experiments. It presents numerous examples of the use of simulation, from detector design and optimization, through software and computing development and testing, to cases where the use of simulation samples made a difference in the accuracy of the physics results and publication turnaround, from data-taking to submission. It also presents the economic impact and cost of simulation in the CMS experiment. Future experiments will collect orders of magnitude more data, taxing heavily the performance of simulation and reconstruction software for increasingly complex detectors. Consequently, it becomes urgent to find solutions to speed up simulation software in order to cope with the increased demand in a time of flat budgets. The study ends with a short discussion on the potential solutions that are being explored, by leveraging core count growth in multicore machines, using new generation coprocessors, and re-engineering of HEP code for concurrency and parallel computing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy-resolved fast-neutron radiography using an event-mode neutron imaging detector

Energy-resolved fast-neutron radiography is a powerful non-destructive technique that can be used to remotely measure the quantity and distribution of elements and isotopes in a sample. This is done by comparing the energy-dependent neutron transmission of a sample with the known cross-sections of individual isotopes. The reconstruction of the composition is possible due to the unique features (e.g. resonances) in the cross-sections of individual isotopes. At short-pulsed (≲ 1 ns) neutron sources, such information is accessible via time-of-flight neutron imaging in principle, but requires a detector with nanosecond temporal resolution. Conventional neutron detectors can meet this requirement only by heavily compromising spatial resolution or efficiency. Here, we present a unique approach on fast neutron resonance radiography using a scintillator-based event-mode imaging detector at a short-pulsed neutron source, including first results on spatially mapped resonance profiles using MeV neutrons. The event mode approach applied in the presented detector allows recording of individual neutron interactions with nanosecond precision in time and sub-mm resolution in space. As a result, the entire available neutron energy spectrum can be measured for each pulse. At the same time, the use of a thick scintillator screen and lenses to focus the produced light results in a highly flexible field of view and a high interaction probability in the sensitive volume of the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Collective excitations and low-energy ionization signatures of relativistic particles in silicon detectors

Abstract Solid-state detectors with a low energy threshold have several applications, including searches of non-relativistic halo dark-matter particles with sub-GeV masses. When searching for relativistic, beyond-the-Standard-Model particles with enhanced cross sections for small energy transfers, a small detector with a low energy threshold may have better sensitivity than a larger detector with a higher energy threshold. In this paper, we calculate the low-energy ionization spectrum from high-velocity particles scattering in a dielectric material. We consider the full material response including the excitation of bulk plasmons. We generalize the energy-loss function to relativistic kinematics, and benchmark existing tools used for halo dark-matter scattering against electron energy-loss spectroscopy data. Compared to calculations commonly used in the literature, such as the Photo-Absorption-Ionization model or the free-electron model, including collective effects shifts the recoil ionization spectrum towards higher energies, typically peaking around 4–6 electron-hole pairs. We apply our results to the three benchmark examples: millicharged particles produced in a beam, neutrinos with a magnetic dipole moment produced in a reactor, and upscattered dark-matter particles. Our results show that the proper inclusion of collective effects typically enhances a detector’s sensitivity to these particles, since detector backgrounds, such as dark counts, peak at lower energies.

Physics↗

Development of a Fast-Spectrum Self-Powered Neutron Detector for Molten Salt Experiments in the Versatile Test Reactor

The self-powered neutron detector (SPND) is a widely used flux monitor in thermal nuclear reactors. Although this is a mature technology, the current state of the art is tuned for a thermal neutron spectrum, so many of the devices currently in use lack sensitivity to fast neutrons. Because current in SPNDs is produced through nuclear reactions with the neutron flux inside a reactor, sensitivity in SPNDs is determined by the neutron cross section of the neutron-sensitive portion of the detector, termed the emitter. This neutron cross section drops by orders of magnitude between thermal and fast neutron energies for many emitters in currently used SPNDs, with a corresponding drop in current from the detector. This paper discusses efforts to develop a fast-spectrum self-powered neutron detector (FS-SPND) that is sensitive to neutrons with energies ranging from 0.025 eV up to 1 MeV. An in-depth analysis of Evaluated Nuclear Data File (ENDF)/B-VII.1 neutron-capture cross sections was performed, and four new materials were identified that are suitable emitter candidates for use in measuring fast neutrons. All four materials are stable mid-shell nuclei in the region between doubly magic 132Sn and 208Pb. Each candidate was simulated with the Geant4 Monte Carlo simulation toolkit to optimize overall detector efficiency.

Goetz, Callie↗

Macromolecular crystallography with a large format CMOS detector

Recent advances in CMOS technology have allowed the production of large surface area detectors suitable for macromolecular crystallography experiments [1]. The Molecular Biology Consortium (MBC) Beamline 4.2.2 at the Advanced Light Source in Berkeley, CA, has installed a 2952 x 2820 mm RDI CMOS-8M detector with funds from NIH grant S10OD012073. The detector has a 20nsec dead pixel time and performs well with shutterless data collection strategies. The sensor obtains sharp point response and minimal optical distortion by use of a thin fiber-optic plate between the phosphor and sensor module. Shutterless data collections produce high-quality redundant datasets that can be obtained in minutes. The fine-sliced data are suitable for processing in standard crystallographic software packages (XDS, HKL2000, D*TREK, MOSFLM). Faster collection times relative to the previous CCD detector have resulted in a record number of datasets collected in a calendar year and de novo phasing experiments have resulted in publications in both Science and Nature [2,3]. The faster collections are due to a combination of the decreased overhead requirements of shutterless collections combined with exposure times that have decreased by over a factor of 2 for images with comparable signal to noise of the NOIR-1 detector. The overall increased productivity has allowed the development of new beamline capabilities and data collection strategies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Unipolar infrared detectors based on InGaAs/InAsSb ternary superlattices

Growth and characteristics of mid-wave infrared (MWIR) InGaAs/InAsSb strained layer superlattice (SLS) detectors are reported. InGaAs/InAsSb SLSs, identified as ternary SLSs, not only provide an extra degree of freedom for superlattice strain compensation but also show enhanced absorption properties compared to InAs/InAsSb SLSs. Utilizing In{sub 1-y}Ga{sub y}As/InAs{sub 0.65}Sb{sub 0.35} ternary SLSs (y = 0, 5, 10, and 20%) designed to have the same bandgap, a set of four unipolar detectors are investigated. These demonstrate an enhancement in the detector quantum efficiency due to the increased absorption coefficient. The detectors exhibit dark current performance within a factor of 10 of Rule 07 at temperatures above 120 K, and external quantum efficiencies in the 15%–25% range. This work demonstrates ternary SLSs are a potential absorber material for future high performance MWIR detectors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental evaluation of the response of micro-channel plate detector to ions with 10s of MeV energies

The absolute calibration of a microchannel plate (MCP) assembly using a Thomson spectrometer for laser-driven ion beams is described. In order to obtain the response of the whole detection system to the particles’ impact, a slotted solid state nuclear track detector (CR-39) was installed in front of the MCP to record the ions simultaneously on both detectors. The response of the MCP (counts/particles) was measured for 5–58 MeV carbon ions and for protons in the energy range 2–17.3 MeV. The response of the MCP detector is non-trivial when the stopping range of particles becomes larger than the thickness of the detector. Protons with energies E ≳ 10 MeV are energetic enough that they can pass through the MCP detector. Quantitative analysis of the pits formed in CR-39 and the signal generated in the MCP allowed to determine the MCP response to particles in this energy range. Moreover, a theoretical model allows to predict the response of MCP at even higher proton energies. This suggests that in this regime the MCP response is a slowly decreasing function of energy, consistently with the decrease of the deposited energy. These calibration data will enable particle spectra to be obtained in absolute terms over a broad energy range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of surface recombination on the charge collection in h-BN neutron detectors

Hexagonal boron nitride (h-BN) epilayers have been recognized as a promising material for applications in solid-state neutron detectors. However, the highest detection efficiency of 58% attained so far for 1 mm 2 detectors fabricated from 50 μm thick B-10 enriched h-BN films still falls short of the expected theoretical value of 64%. This is due to the less than perfect charge collection efficiency. In this work, we have fabricated and analyzed photocurrent-voltage characteristics of 11 h-BN neutron detectors. The dependence of the charge collection efficiency ( n c ) on the charge carrier mobility-lifetime (µτ) product of the bulk trapping parameter reveals that the charge collection efficiency n c is nearly perfect at a bias voltage of 200 V if we neglect the effects of surface recombination. Our results have clearly demonstrated that the surface recombination of charge carriers is the dominant factor which prevents a further enhancement in the charge collection efficiency in our current detectors. The surface recombination field E S (= s/µ), defined as the ratio of the surface recombination velocity (s) to the carrier mobility (µ), of holes was found to have a linear relationship with that of electrons and has a magnitude on the order of 10 4 V/cm. Here the present study indicates that it is critical to reduce surface recombination E S in h-BN in order to further push the charge collection and hence the total detection efficiency of h-BN neutron detectors to 100%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

GaAs x-ray detectors with sub-nanosecond temporal response

Fast semiconductor radiation detectors operated in current mode provide a valuable diagnostic in pulsed power applications. Si detectors are common due to the availability of high-quality materials and mature fabrication processes, but they offer low absorption for hard x-rays above ∼10 keV. GaAs can provide increased hard x-ray absorption for the same detector volume due to a higher atomic number. GaAs photodiodes have been produced from epitaxial material grown at Sandia National Laboratories and fabricated at Sandia’s microfabrication facility. These detectors have significantly higher hard x-ray absorption (>10× at 15 keV) and nearly identical temporal impulse response to similarly sized Si detectors of 0.5 ns full-width half maximum.

Looker, Quinn (ORCID:0000000325820630)↗

Large-volume CdZnTe bar detectors characterized by laser-induced transient currents

In this work, we studied the free-carrier transport properties and space-charge formation/polarization in a CdZnTe bar-shaped radiation detector using the Laser-Induced Transient Current technique. We found out that a steady-state space charge ranging from 8 x 10 8 to 2.1 x 10 9 cm -3 is formed throughout the detector at about 0.5 s following biasing. The measured current waveforms were modeled by Monte Carlo simulations after taking into account the electric and weighting fields inside the detector and shielding box. Modeling of the unpolarized waveforms revealed an exceptionally high electron mobility-lifetime product μ e τ e ≥0.095cm 2 V -1 . The observed formation of positive space charge in the biased detector and linear scaling of the current waveform shapes on applied bias revealed that the detector polarization is attributed to carrier injection at the anode. In conclusion, measurements in pulsed and DC bias in modified electrode geometry proved the surface-charge formation.

47 OTHER INSTRUMENTATION↗

Evidence for ionization damage in mid-wave infrared nBn detectors

The effects of 63 MeV proton and 60Co gamma irradiation on the operation of 4.3 μm cutoff nBn photodetectors are demonstrated separately, and both are shown to yield a total ionizing dose (TID) effect. The effect is shown here in an InAsSbBi nBn detector and has been observed in other bulk alloy nBn detectors, and is unusual as it is notably absent in superlattice nBn detectors. The non-antireflection coated detectors exhibit a pre-radiation quantum efficiency of 17% at 3.3 μm wavelength and a dark current density of 50 μA/cm2, or roughly 300× the Rule 07 expectation, at their ideal operating voltage of −0.4 V bias at 150 K. Step-wise proton irradiation and in situ measurement indicate that the dark current increases to about 400× Rule 07 at the highest proton dose level of 150 krad(Si) (9.10 × 1011 p+/cm2), while the quantum efficiency is degraded at a relatively faster rate than the majority of analogous detectors characterized by our lab. Both the photocurrent and dark current are also shown to exhibit a turn-on voltage magnitude reduction of 100 mV following either gamma or proton irradiation, a trend which is attributable to negative trapped charge at the barrier interface (TID effect). This theory is further supported by an observed capacitance density magnitude reduction with dose and affirmed with Silvaco TCAD simulations. Following both proton exposure and subsequent anneal and gamma exposure and subsequent anneal; dark current, photocurrent, and CV all approach their pre-radiation baseline values.

Physics↗