Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DOSIMETRY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Status - International Space Station (ISS) Crewmembers' Noise Exposures

Environmental noise in space vehicles caused by onboard equipment and noisy activities has generated concerns for crew health and safety since early U.S. space missions. The International Space Station (ISS) provides a unique environment where acoustic conditions can be monitored while crewmembers from the U.S. and their international partners work and live for as long as 6 to 12 consecutive months. This review of acoustic dosimetry data collected to date reveals that the noise exposure limits of NASA’s stringent noise constraint flight rule have been exceeded in 41% of these dosimetry measurements since ISS Increment 17 (2008), with undefined impacts to crew. These measurements do not take into account the effects of hearing protection devices worn by the crew. The purpose of this paper is to provide an update on ISS noise exposure monitoring approaches and hearing conservation strategies that include acoustic dosimetry data collected since the ISS Increment 55 mission (April 2018). Future directions and recommendations for the ISS noise exposure monitoring program will also be presented, including research initiatives aimed at better defining the impact of ISS noise on crew health and performance.

Jose G Limardo↗

Comparative assessment of neutron flux sensor technologies for advanced reactors

This report documents the comparative assessment of the rhodium-based self-powered neutron detectors (Rh-SPND), micro-pocket fission detectors (MPFD), and dosimetry wires in heated irradiations at the Neutron Radiography reactor facility at Idaho National Laboratory. The sensors performances are evaluated high-temperature environments (upwards of 850°C) during maximum reactor power to simulate use in advanced reactor applications. The performance of the Rh-SPNDs indicates the experiment cartridge heater power supply interferes with the SPND signals. This interference become increasingly significant at temperatures above 500°C with minimal interference observed for temperatures below 500°C. This work also demonstrated the fabrication process for the updated design of the MPFD, but issues related to the seal welds were identified and usable data was limited. Finally, the dosimetry measurements were within the expected range correlated with reactor power; thus, the dosimetry results were used to provide preliminary SPND calibration factors. The results from this experiment serves as a reference for developing and testing of flux sensors that are designed for high-temperature irradiations and advanced reactor deployments. This includes upcoming FY22 irradiations at the Massachusetts Institute of Technology Reactor and the Neutron Radiography (NRAD) reactor utilizing additional fission chambers from Photonis Technologies and fission chambers and SPNDs from The French Alternative Energies and Atomic Energy Commission.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of 3-dimensional dose reconstruction system between fluence-based system and dose measurement-guided system

COMPASS system (IBA Dosimetry, Schwarzenbruck, Germany) and ArcCHECK with 3DVH software (Sun Nuclear Corp., Melbourne, FL) are commercial quasi-3-dimensional (3D) dosimetry arrays. Cross-validation to compare them under the same conditions, such as a treatment plan, allows for clear evaluation of such measurement devices. In this study, we evaluated the accuracy of reconstructed dose distributions from the COMPASS system and ArcCHECK with 3DVH software using Monte Carlo simulation (MC) for multi-leaf collimator (MLC) test patterns and clinical VMAT plans. In a phantom study, ArcCHECK 3DVH showed clear differences from COMPASS, measurement and MC due to the detector resolution and the dose reconstruction method. Especially, ArcCHECK 3DVH showed 7% difference from MC for the heterogeneous phantom. ArcCHECK 3DVH only corrects the 3D dose distribution of treatment planning system (TPS) using ArcCHECK measurement, and therefore the accuracy of ArcCHECK 3DVH depends on TPS. In contrast, COMPASS showed good agreement with MC for all cases. However, the COMPASS system requires many complicated installation procedures such as beam modeling, and appropriate commissioning is needed. In terms of clinical cases, there were no large differences for each QA device. The accuracy of the compass and ArcCHECK 3DVH systems for phantoms and clinical cases was compared. Both systems have advantages and disadvantages for clinical use, and consideration of the operating environment is important. The QA system selection is depending on the purpose and workflow in each hospital.

61 RADIATION PROTECTION AND DOSIMETRY↗

Is a single isocenter sufficient for volumetric modulated arc therapy radiosurgery when multiple intracranial metastases are spatially dispersed?

Previous work demonstrated improved dosimetry of single isocenter volumetric modulated arc therapy (VMAT) of multiple intracranial targets when they are located ≤ 4 cm from isocenter because of narrower multileaf collimators (MLCs). In follow-up, we sought to determine if decreasing isocenter-target distance (d{sub iso}) by using 2 to 3 isocenters would improve dosimetry for spatially dispersed targets. We also investigated the effect of a maximum dose constraint during VMAT optimization, and the dosimetric effect of the number of VMAT arcs used for a larger number of targets (i.e., 7 to 9). We identified radiosurgery cases that had multiple intracranial targets with d{sub iso} of at least 1 target > 5 cm. A single isocenter VMAT plan was created using a standardized 4-arc technique with 18 Gy per target. Each case was then replanned (1) using 2 to 3 isocenters, (2) including a maximum dose constraint per target, and in the case of 7 to 9 targets, (3) using 3 to 6 arcs. Dose evaluation included brain V{sub 6} {sub Gy} and V{sub 12} {sub Gy}, and conformity index (CI), gradient index (GI), and heterogeneity index (HI) per target. Two isocenters were sufficient to limit d{sub iso} to ≤ 4 cm and ≤ 5 cm for 11/15 and 13/15 cases, respectively; after replanning with 2 to 3 isocenters, d{sub iso} decreased from 5.8 ± 2.8 cm (2.3 14.9) to 2.5 ± 1.4 cm (0 5.2). All dose statistics improved on average, albeit modestly: V{sub 6} {sub Gy} = 6.9 ± 7.1%, V{sub 12} {sub Gy} = 0.9% ± 4.4%, CI = 2.6% ± 4.6%, GI = 0.9% ± 12.7%, and HI = 2.6% ± 5.2%; however, the number of arcs doubled and monitor units increase by nearly 2-fold. A maximum dose constraint had a negative effect on all dose indices, increasing V{sub 12} {sub Gy} by 9.7 ± 6.9%. For ≥ 7 targets, increasing number of arcs to > 3 improved CI, V{sub 12} {sub Gy}, and V{sub 6} {sub Gy}. A single isocenter is likely sufficient for VMAT radiosurgery of multiple intracranial metastases. Optimal treatment plan quality is achieved when no constraint is placed on the maximum target dose; for cases with many targets at least 4 arcs are needed for optimal plan quality.

61 RADIATION PROTECTION AND DOSIMETRY↗

Covariance Propagation in Spectral Indices

The dosimetry community has a history of using spectral indices to support neutron spectrum characterization and cross section validation efforts. An important aspect to this type of analysis is the proper consideration of the contribution of the spectrum uncertainty to the total uncertainty in calculated spectral indices (SIs). This paper identifies deficiencies in the traditional treatment of the SI uncertainty, provides simple bounds to the spectral component in the SI uncertainty estimates, verifies that these estimates are reflected in actual applications, details a methodology that rigorously captures the spectral contribution to the uncertainty in the SI, and provides quantified examples that demonstrate the importance of the proper treatment the spectral contribution to the uncertainty in the SI.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Estimation of iodine nutrition and thyroid function status in late-gestation pregnant women in the United States: Development and application of a population-based pregnancy model

Previously, a deterministic biologically-based dose-response (BBDR) pregnancy model was developed to evaluate moderate thyroid axis disturbances with and without thyroid-active chemical exposure in a near-term pregnant woman and fetus. In the current study, the existing BBDR model was adapted to include a wider functional range of iodine nutrition, including more severe iodine deficiency conditions, and to incorporate empirically the effects of homeostatic mechanisms. The extended model was further developed into a population-based model and was constructed using a Monte Carlo-based probabilistic framework. In order to characterize total (T4) and free (fT4) thyroxine levels for a given iodine status at the population-level, the distribution of iodine intake for late-gestation pregnant women in the U.S was reconstructed using various reverse dosimetry methods and available biomonitoring data. The range of median (mean) iodine intake values resulting from three different methods of reverse dosimetry tested was 196.5–219.9 μg of iodine/day (228.2–392.9 μg of iodine/day). There was minimal variation in model-predicted maternal serum T4 and ft4 thyroxine levels from use of the three reconstructed distributions of iodine intake; the range of geometric mean for T4 and fT4, was 138–151.7 nmol/L and 7.9–8.7 pmol/L, respectively. The average value of the ratio of the 97.5th percentile to the 2.5th percentile equaled 3.1 and agreed well with similar estimates from recent observations in third-trimester pregnant women in the U.S. In addition, the reconstructed distributions of iodine intake allowed us to estimate nutrient inadequacy for late-gestation pregnant women in the U.S. via the probability approach. The prevalence of iodine inadequacy for third-trimester pregnant women in the U.S. was estimated to be between 21% and 44%. Taken together, the current work provides an improved tool for evaluating iodine nutritional status and the corresponding thyroid function status in pregnant women in the U.S. This model enables future assessments of the relevant risk of thyroid hormone level perturbations due to exposure to thyroid-active chemicals at the population-level. - Highlights: • A population-based thyroid function model for pregnant women was developed. • The model was used specifically study the late-gestation pregnant women in the U.S. • The prevalence of iodine inadequacy was estimated in the sub-population studied. • Developed model well predicts trimester-specific thyroid hormone reference ranges. • The model can be further used to study thyroid perturbations at a population level.

60 APPLIED LIFE SCIENCES↗

Backscatter Correction Algorithm for TBI Treatment Conditions

The accuracy requirements in target dose delivery is, according to ICRU, ±5%. This is so not only in standard radiotherapy but also in total body irradiation (TBI). Physical dosimetry plays an important role in achieving this recommended level. The semi-infinite phantoms, customarily used for dosimetry purposes, give scatter conditions different to those of the finite thickness of the patient. So dose calculated in patient’s points close to beam exit surface may be overestimated. It is then necessary to quantify the backscatter factor in order to decrease the uncertainty in this dose calculation. The backward scatter has been well studied at standard distances. The present work intends to evaluate the backscatter phenomenon under our particular TBI treatment conditions. As a consequence of this study, a semi-empirical expression has been derived to calculate (within 0.3% uncertainty) the backscatter factor. This factor depends lineally on the depth and exponentially on the underlying tissue. Differences found in the qualitative behavior with respect to standard distances are due to scatter in the bunker wall close to the measurement point.

61 RADIATION PROTECTION AND DOSIMETRY↗

Validation of IRDFF in 252Cf standard and IRDF-2002 reference neutron fields

The results of validation of the latest release of International Reactor Dosimetry and Fusion File, IRDFF-1.03, in the standard 252Cf(s.f.) and reference 235U(nth,f) neutron benchmark fields are presented. The spectrum-averaged cross sections were shown to confirm the recommended spectrum for 252Cf spontaneous fission source; that was not the case for the current recommended spectra for 235U(nth,f). IRDFF was also validated in the spectra of the research reactor facilities ISNF, Sigma-Sigma and YAYOI, which are available in the IRDF- 2002 collection. Before this analysis, the ISFN spectrum was resimulated to remove unphysical oscillations in spectrum. IRDFF-1.03 was shown to reasonably reproduce the spectrum-averaged data measured in these fields except for the case of YAYOI.

IRDFF↗

Preliminary analysis of TREAT free-field experiments using openmc

This work analyses activation calculations for dosimetry materials during a steady-state irradiation in the Transient Reactor Test (TREAT) reactor core. Hence, we developed a workflow based on the Monte Carlo code OpenMC alongside a custom depletion solver. The irradiation-induced activity as a function of time is computed, and several sensitivity studies are performed to evaluate uncertainty. This study has shown activity computations are sensitive to flux amplitude, irradiation time, atoms quantity and microscopic cross sections. Stochastic uncertainties have been propagated to evaluate the activity uncertainty for each dosimetry material. Most uncertainties are below our target of 3%, which demonstrates OpenMC as a powerful predictive and analysis tool. The precise results obtained through this newly developed computation scheme will be used in future experiments to characterize quantities of interest when operating the TREAT reactor in new configurations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Dosimetric property of mineral extracted from calamari and exposed to gamma rays

Dosimetric property of polymineral fraction, quartz mainly, obtained from calamari was investigated. The commercial calamari samples from China and Sud Africa were collected in the markets of Italy. All polymineral debris were extracted and isolated from the whole body of calamari. The surface of the polymineral samples was analyzed by using the Scanning Electron Microscopy (SEM) and their chemical composition was determined using Energy Dispersive Spectroscopy (EDS). The polymineral was exposed to gamma rays ({sup 60}Co) at different doses (0.5-80 Gy) to determine dosimetric property. Thermoluminescent (TL) glow curves showed two peaks centered at around 98-100 Degree-Sign C and 128-138 Degree-Sign C temperature range. The glow curves have been analyzed by using a deconvolution program. A linear dose response between 0.5 to 20 Gy was observed. The TL response of the samples as a function of the time storage, fading, presented a reduction of about 36-40 % at the end of 24 h. The reproducibility of the TL response after ten cycles of irradiation-readout showed an acceptable standard deviation in dosimetry. The polimineral fraction obtained from calamari shows an interesting dosimetric property and it may be useful for dosimetry in gamma radiation field.

36 MATERIALS SCIENCE↗

Evaluation of Repurposing Archetypal Preventive Radiological/Nuclear Detectors to the Consequence Management Mission

In the first hours or days after an unplanned release of radioactive material to the environment, the radiation detection instruments most widely available to local first responders may be those currently fielded for interdiction missions. This study investigated how such preventative radiological / nuclear detection instruments could perform if repurposed to consequence management missions. A representative sample of three archetypes (body-worn, human carried, and other/large detection volume) encompassed six categories: personal radiation detector, extended range personal radiation detector, personal emergency radiation detector, radio-isotope identification device, human portable detector/backpack, and vehicle mounted large detection volume. Overall 19 models of equipment were included in the study. Laboratory evaluations were designed to assess the capabilities of the instruments in four consequence management missions: exposure rate, integrated exposure, radiation survey, and contamination screening. As applicable, the evaluations included measurement of exposure rate, integrated exposure, overrange response, and angular response. The results were compared to benchmarks from the American National Standards Institute ANSI N42.49A. The performance of the instruments for initial screening for contamination was assessed by an automated radioactive source moving past the detectors at various speeds and distances. The results demonstrate that if the equipment is used in accordance with the mission analysis and categories, and within the original equipment manufacturer specifications, it is possible to achieve sufficient accuracy to estimate and document doses to responders, plan entries into contaminated areas, detect contamination, and protect the public, until such time as outside resources arrive with sufficient numbers of standard health physics instruments and personnel dosimetry to replace the preventative radiological / nuclear detection instruments. Finally, this evaluation campaign was conducted to complement the National Council on Radiation Protection and Measurements Report-179 on Guidance for Emergency Response Dosimetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Small fields output factors measurements and correction factors determination for several detectors for a CyberKnife{sup Registered-Sign} and linear accelerators equipped with microMLC and circular cones

Purpose: The use of small photon fields is now an established practice in stereotactic radiosurgery and radiotherapy. However, due to a lack of lateral electron equilibrium and high dose gradients, it is difficult to accurately measure the dosimetric quantities required for the commissioning of such systems. Moreover, there is still no metrological dosimetric reference for this kind of beam today. In this context, the first objective of this work was to determine and to compare small fields output factors (OF) measured with different types of active detectors and passive dosimeters for three types of facilities: a CyberKnife{sup Registered-Sign} system, a dedicated medical linear accelerator (Novalis) equipped with m3 microMLC and circular cones, and an adaptive medical linear accelerator (Clinac 2100) equipped with an additional m3 microMLC. The second one was to determine the k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors introduced in a recently proposed small field dosimetry formalism for different active detectors.Methods: Small field sizes were defined either by microMLC down to 6 Multiplication-Sign 6 mm{sup 2} or by circular cones down to 4 mm in diameter. OF measurements were performed with several commercially available active detectors dedicated to measurements in small fields (high resolution diodes: IBA SFD, Sun Nuclear EDGE, PTW 60016, PTW 60017; ionizing chambers: PTW 31014 PinPoint chamber, PTW 31018 microLion liquid chamber, and PTW 60003 natural diamond). Two types of passive dosimeters were used: LiF microcubes and EBT2 radiochromic films.Results: Significant differences between the results obtained by several dosimetric systems were observed, particularly for the smallest field size for which the difference in the measured OF reaches more than 20%. For passive dosimeters, an excellent agreement was observed (better than 2%) between EBT2 and LiF microcubes for all OF measurements. Moreover, it has been shown that these passive dosimeters do not require correction factors and can then be used as reference dosimeters. Correction factors for the active detectors have then been determined from the mean experimental OF measured by the passive dosimeters.Conclusions: Four sets of correction factors needed to apply the new small field dosimetry formalism are provided for several active detectors. A protocol for small photon beams OF determination based on passive dosimeters measurements has been recently proposed to French radiotherapy treatment centers.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Fano cavity test for Monte Carlo proton transport algorithms

Purpose: In the scope of reference dosimetry of radiotherapy beams, Monte Carlo (MC) simulations are widely used to compute ionization chamber dose response accurately. Uncertainties related to the transport algorithm can be verified performing self-consistency tests, i.e., the so-called “Fano cavity test.” The Fano cavity test is based on the Fano theorem, which states that under charged particle equilibrium conditions, the charged particle fluence is independent of the mass density of the media as long as the cross-sections are uniform. Such tests have not been performed yet for MC codes simulating proton transport. The objectives of this study are to design a new Fano cavity test for proton MC and to implement the methodology in two MC codes: Geant4 and PENELOPE extended to protons (PENH). Methods: The new Fano test is designed to evaluate the accuracy of proton transport. Virtual particles with an energy ofE{sub 0} and a mass macroscopic cross section of (Σ)/(ρ) are transported, having the ability to generate protons with kinetic energy E{sub 0} and to be restored after each interaction, thus providing proton equilibrium. To perform the test, the authors use a simplified simulation model and rigorously demonstrate that the computed cavity dose per incident fluence must equal (ΣE{sub 0})/(ρ) , as expected in classic Fano tests. The implementation of the test is performed in Geant4 and PENH. The geometry used for testing is a 10 × 10 cm{sup 2} parallel virtual field and a cavity (2 × 2 × 0.2 cm{sup 3} size) in a water phantom with dimensions large enough to ensure proton equilibrium. Results: For conservative user-defined simulation parameters (leading to small step sizes), both Geant4 and PENH pass the Fano cavity test within 0.1%. However, differences of 0.6% and 0.7% were observed for PENH and Geant4, respectively, using larger step sizes. For PENH, the difference is attributed to the random-hinge method that introduces an artificial energy straggling if step size is not small enough. Conclusions: Using conservative user-defined simulation parameters, both PENH and Geant4 pass the Fano cavity test for proton transport. Our methodology is applicable to any kind of charged particle, provided that the considered MC code is able to track the charged particle considered.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Seeing the invisible: Direct visualization of therapeutic radiation beams using air scintillation

Purpose: To assess whether air scintillation produced during standard radiation treatments can be visualized and used to monitor a beam in a nonperturbing manner. Methods: Air scintillation is caused by the excitation of nitrogen gas by ionizing radiation. This weak emission occurs predominantly in the 300–430 nm range. An electron-multiplication charge-coupled device camera, outfitted with an f/0.95 lens, was used to capture air scintillation produced by kilovoltage photon beams and megavoltage electron beams used in radiation therapy. The treatment rooms were prepared to block background light and a short-pass filter was utilized to block light above 440 nm. Results: Air scintillation from an orthovoltage unit (50 kVp, 30 mA) was visualized with a relatively short exposure time (10 s) and showed an inverse falloff (r{sup 2} = 0.89). Electron beams were also imaged. For a fixed exposure time (100 s), air scintillation was proportional to dose rate (r{sup 2} = 0.9998). As energy increased, the divergence of the electron beam decreased and the penumbra improved. By irradiating a transparent phantom, the authors also showed that Cherenkov luminescence did not interfere with the detection of air scintillation. In a final illustration of the capabilities of this new technique, the authors visualized air scintillation produced during a total skin irradiation treatment. Conclusions: Air scintillation can be measured to monitor a radiation beam in an inexpensive and nonperturbing manner. This physical phenomenon could be useful for dosimetry of therapeutic radiation beams or for online detection of gross errors during fractionated treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multi-institutional dosimetric and geometric commissioning of image-guided small animal irradiators

Purpose: To compare the dosimetric and geometric properties of a commercial x-ray based image-guided small animal irradiation system, installed at three institutions and to establish a complete and broadly accessible commissioning procedure. Methods: The system consists of a 225 kVp x-ray tube with fixed field size collimators ranging from 1 to 44 mm equivalent diameter. The x-ray tube is mounted opposite a flat-panel imaging detector, on a C-arm gantry with 360° coplanar rotation. Each institution performed a full commissioning of their system, including half-value layer, absolute dosimetry, relative dosimetry (profiles, percent depth dose, and relative output factors), and characterization of the system geometry and mechanical flex of the x-ray tube and detector. Dosimetric measurements were made using Farmer-type ionization chambers, small volume air and liquid ionization chambers, and radiochromic film. The results between the three institutions were compared. Results: At 225 kVp, with 0.3 mm Cu added filtration, the first half value layer ranged from 0.9 to 1.0 mm Cu. The dose-rate in-air for a 40 × 40 mm{sup 2} field size, at a source-to-axis distance of 30 cm, ranged from 3.5 to 3.9 Gy/min between the three institutions. For field sizes between 2.5 mm diameter and 40 × 40 mm{sup 2}, the differences between percent depth dose curves up to depths of 3.5 cm were between 1% and 4% on average, with the maximum difference being 7%. The profiles agreed very well for fields >5 mm diameter. The relative output factors differed by up to 6% for fields larger than 10 mm diameter, but differed by up to 49% for fields ≤5 mm diameter. The mechanical characteristics of the system (source-to-axis and source-to-detector distances) were consistent between all three institutions. There were substantial differences in the flex of each system. Conclusions: With the exception of the half-value layer, and mechanical properties, there were significant differences between the dosimetric and geometric properties of the three systems. This underscores the need for careful commissioning of each individual system for use in radiobiological experiments.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of TG-43 and TG-186 in breast irradiation using a low energy electronic brachytherapy source

Purpose: The recently updated guidelines for dosimetry in brachytherapy in TG-186 have recommended the use of model-based dosimetry calculations as a replacement for TG-43. TG-186 highlights shortcomings in the water-based approach in TG-43, particularly for low energy brachytherapy sources. The Xoft Axxent is a low energy (<50 kV) brachytherapy system used in accelerated partial breast irradiation (APBI). Breast tissue is a heterogeneous tissue in terms of density and composition. Dosimetric calculations of seven APBI patients treated with Axxent were made using a model-based Monte Carlo platform for a number of tissue models and dose reporting methods and compared to TG-43 based plans. Methods: A model of the Axxent source, the S700, was created and validated against experimental data. CT scans of the patients were used to create realistic multi-tissue/heterogeneous models with breast tissue segmented using a published technique. Alternative water models were used to isolate the influence of tissue heterogeneity and backscatter on the dose distribution. Dose calculations were performed using Geant4 according to the original treatment parameters. The effect of the Axxent balloon applicator used in APBI which could not be modeled in the CT-based model, was modeled using a novel technique that utilizes CAD-based geometries. These techniques were validated experimentally. Results were calculated using two dose reporting methods, dose to water (D{sub w,m}) and dose to medium (D{sub m,m}), for the heterogeneous simulations. All results were compared against TG-43-based dose distributions and evaluated using dose ratio maps and DVH metrics. Changes in skin and PTV dose were highlighted. Results: All simulated heterogeneous models showed a reduced dose to the DVH metrics that is dependent on the method of dose reporting and patient geometry. Based on a prescription dose of 34 Gy, the average D{sub 90} to PTV was reduced by between ∼4% and ∼40%, depending on the scoring method, compared to the TG-43 result. Peak skin dose is also reduced by 10%–15% due to the absence of backscatter not accounted for in TG-43. The balloon applicator also contributed to the reduced dose. Other ROIs showed a difference depending on the method of dose reporting. Conclusions: TG-186-based calculations produce results that are different from TG-43 for the Axxent source. The differences depend strongly on the method of dose reporting. This study highlights the importance of backscatter to peak skin dose. Tissue heterogeneities, applicator, and patient geometries demonstrate the need for a more robust dose calculation method for low energy brachytherapy sources.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-P-04: Transport Theory Learning Module in the Maple Environment

Purpose: The medical physics graduate program at the University of Miami is developing a computerized instructional module which provides an interactive mechanism for students to learn transport theory. While not essential in the medical physics curriculum, transport theory should be taught because the conceptual level of transport theory is fundamental, a substantial literature exists and ought to be accessible, and students should understand commercial software which solves the Boltzmann equation.But conventional teaching and learning of transport theory is challenging. Students may be under prepared to appreciate its methods, results, and relevance, and it is not substantially addressed in textbooks for the medical physicists. Other resources an instructor might reasonably use, while excellent, may be too briskly paced for beginning students. The purpose of this work is to render teaching of transport theory more tractable by making learning highly interactive. Methods: The module is being developed in the Maple mathematics environment by instructors and graduate students. It will refresh the students' knowledge of vector calculus and differential equations, and will develop users' intuition for phase space concepts. Scattering concepts will be developed with animated simulations using tunable parameters characterizing interactions, so that students may develop a “feel” for cross section. Transport equations for one and multiple types of radiation will be illustrated with phase space animations. Numerical methods of solution will be illustrated. Results: Attempts to teach rudiments of transport theory in radiation physics and dosimetry courses using conventional classroom techniques at the University of Miami have had small success, because classroom time is limited and the material has been hard for our students to appreciate intuitively. Conclusion: A joint effort of instructor and students to teach and learn transport theory by building an interactive description of it will lead to deeper appreciation of the transport theoretical underpinnings of dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-415: An Ionization Chamber Array with High Spatial Resolution for External Beam Radiotherapy

Purpose: To characterize an ionization chamber array technology with high spatial resolution and high charge collection efficiency for external beam radiotherapy. Methods: The prototype under test is a linear array of air vented ionization chambers developed by IBA Dosimetry, consisting of 80 pixels with 3.5mm spatial resolution and 4mm{sup 3} sensitive volume. The detector was characterized in a plastic phantom with {sup 60} Co radiation and MV X-rays from an ELEKTA Agility LINAC (with flattened and unflattened beam qualities). Bias voltage was varied in order to evaluate charge collection efficiency. A commercial array of ionization chambers (MatriXX Evolution, IBA Dosimetry) and an amorphous silicon flat panel in direct conversion configuration were used as references. Results: Repeatability (0.4%) and stability under continuous gamma irradiation (0.3%) are very good, in spite of low active volume and sensitivity (∼200pC/Gy). Charge collection efficiency is higher than 99% already at 150V with ∼2mGy dose per pulse, leading to a ±1.1% sensitivity change with dose per pulse in the range 0.09-2mGy (covering all flattened and unflattened applications). Measured dose profiles are in agreement with MatriXX for fields larger than 2×2cm{sup 2}, in which case the linear array offers a much better characterization of the penumbra region. Down to 1×1cm{sup 2}, measured profiles are in very good agreement with the flat panel. Conclusion: The array represents a valuable tool for the characterization of treatment fields in which high spatial resolution is required, together with the dosimetric performance of air vented ionization chambers. Such a technology would be particularly valuable in association with advanced treatment modalities such as rotational radiotherapy, stereotactic treatments (even with unflattened beam qualities) and proton therapy, due to the insensitivity of the chambers on dose per pulse. In the future, a two dimensional prototype based on this technology will be developed and tested. This research project has been supported by a Marie Curie Early Initial Training Network Fellowship of the European Community's Seventh Framework Programme under contract number (PITN-GA-2011-289198-.

07 ISOTOPE AND RADIATION SOURCES↗