Identifying Observables that Discriminate Between Impulsive and Footpoint Heating: Long Time Delays
No abstract available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
No abstract available
An examination of the Hubble Space Telescope Wide Field Planetary Camera 2 (WFPC-2) radiator assembly was conducted at NASA Goddard Space Flight Center during the summer of 2009. Immediately apparent was the predominance of impact features, identified as simple or complex craters, resident only in the thermal paint layer; similar features were observed during a prior survey of the WFPC-1 radiator. Larger impact features displayed spallation zones, darkened areas, and other features not observed in impacts onto bare surfaces. Craters were extracted by coring the radiator in the NASA Johnson Space Center’s Space Exposed Hardware cleanroom and were subsequently examined using scanning electron microscopy/energy dispersive X-ray spectroscopy to determine the likely origin, e.g., micrometeoritic or orbital debris, of the impacting projectile. Recently, a selection of large cores was re-examined using a new technique developed to overcome some limitations of traditional crater imaging and analysis. This technique, motivated by thin section analysis, examines a polished, lateral surface area revealed by cross-sectioning the core sample. This paper reviews the technique, the classification rubric as extended by this technique, and results to date.
Simulated mine detection was performed on a polarimetric hyperspectral imaging dataset collected by using an acousto-optic tunable filter camera. A feedforward artificial neural network was programmed to recognize predefined spectral "templates." The simulation results are provided along with the preprocessing steps and window sizes leading to mine detection without false alarms.
Geologic maps are, by their very nature, interpretive documents. In contrast, images prepared from AVIRIS data can be used as uninterpreted, and thus unbiased, geologic maps. We are having significant success applying AVIRIS data in this non-quantitative manner to geologic problems. Much of our success has come from the power of the Linked Windows Interactive Data System. LinkWinds is a visual data analysis and exploration system under development at JPL which is designed to rapidly and interactively investigate large multivariate data sets. In this paper, we present information on the analysis technique, and preliminary results from research on potassium metasomatism, a distinctive and structurally significant type of alteration associated with crustal extension.
This conceptual study presents advanced radiative transfer computations of light polarization originating from a snowpack consisting of nonspherical grains and variable content of light-absorbing impurities, either embedded in the snowpack or (with the same optical properties) lofted above it in the form of atmospheric aerosols. The results highlight the importance of considering shapes other than spherical for the snow grains, which otherwise can lead to non-negligible errors in the retrieval of snow albedo from remote sensing observations. More importantly, it is found that polarimetric measurements provide a means to partition light-absorbing impurities embedded in the snowpack from absorbing aerosols aloft, a task traditionally prohibitive for sensors capable exclusively of measurements of total reflectance. Heritage techniques to obtain snow grain size from shortwave infrared observations of total reflectance are well established, as are those that leverage polarimetric, multiangular observations across the entire optical spectrum to characterize the optical and microphysical properties of atmospheric aerosols. The polarization signatures of near-infrared (e.g., 864 nm) observations carry critical information on snow grain shape. The prospected launch of space-borne polarimeters with proven accuracy, therefore, advocates for the development of data inversion schemes, to boost the accuracy of simultaneous retrievals of atmospheric and surface parameters in the polar and snow-covered regions, critical to climate studies.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Accurate knowledge of the composition of the Sun provides a baseline, which allows an understanding of how the solar system has evolved over time and how solar processes and solar wind mechanics behave. Unfortunately, the errors in photospheric abundances are too large for many planetary science problems and this hampers our understanding of these different processes. Analyses of solar wind implanted in meteorites or lunar soils have provided more precise data [e.g. 1 and references therein] but the extent to which alteration processes on these bodies complicate such information is only now being determined. Therefore, in order to obtain pristine solar wind samples, NASA developed and launched the Genesis Discovery Mission. Unfortunately, the probe crash-landed shattering the 300 collector plates into 15,000+ pieces complicating the analysis and necessitating the development of new analytical techniques and equipment. Thus, shards from the Genesis collector array and their appropriate flight spares are currently being characterized via grazing-incidence synchrotron x-ray techniques at the Advanced Photon Source at Argonne National Laboratory. The goals are (1) determine solar wind fluences of the elements Ca-Ge by grazing-incidence angle-resolved x-ray fluorescence (XRF) and x-ray reflectivity, (2) improve data reduction via the development of XRF spectral deconvolution routines and develop modeling algorithms for reflectivity and fluorescence yield analysis in order to determine element specific depth profiles from which absolute concentration may be extracted and (3) designing and developing a new multi-element silicon multi-channel (SMCD) detector system. These improvements will increase our sensitivity by a factor of three or more, reduce measurement time at a given sensitivity to one-eighth and the minimum detection limit would be reduced by a factor of 3 to {approx}3 x 10{sup 8} atoms/cm{sup 2}.
An ultra-low magnetic field NMR system can non-invasively examine containers. Database matching techniques can then identify hazardous materials within the containers. Ultra-low field NMR systems are ideal for this purpose because they do not require large powerful magnets and because they can examine materials enclosed in conductive shells such as lead shells. The NMR examination technique can be combined with ultra-low field NMR imaging, where an NMR image is obtained and analyzed to identify target volumes. Spatial sensitivity encoding can also be used to identify target volumes. After the target volumes are identified the NMR measurement technique can be used to identify their contents.
Metal-organic frameworks (MOFs) represent a diverse and rapidly expanding class of materials comprising metal ions bridged by organic linker molecules. These robust crystalline structures have been found to exhibit exceptionally large surface areas, paving the way for diverse applications ranging from gas storage and separations to catalysis, drug delivery, and sensing. Less well understood are the intrinsic luminescence properties of MOFs, which arise from the electronic transitions within the hybrid metal-organic structure. Recently, we reported the observation of scintillation in stilbene-based MOFs, representing the discovery of the first completely new class of radiation detection materials since the advent of plastic scintillators in 1950. Photoluminescence and ion-induced luminescence spectroscopy of these materials show that both the luminescence spectrum and its timing can be varied by altering the local environment of the chromophore, establishing critical insight towards the rational design of materials for specific radiation detection applications. In this work, we describe the luminescence and scintillating properties of a series of isoreticular MOFs (IRMOFs), emphasizing the structural and electronic effects associated with systematic modification of the chromophore. Among these structures are IRMOFs based on naphthyl, biphenyl, terphenyl, and stilbene dicarboxylate linkers, for which unique structural changes and optical properties are observed. In addition to chemical changes in the structure, framework interpenetration may also be synthetically controlled, resulting in pairs of catenated and non-catenated IRMOFs based upon the same organic linker. The distinct interchromophore distances and solvate structure in these pairs lead to unique luminescence spectra that are interpreted in terms of energy transfer interactions. These spectral changes provide insight into the mechanism for radiation-induced luminescence, which for MOFs may differ significantly from the photoluminescence spectrum.
Recent numerical studies of Free Electron Lasers (FELs) operating in the Self Amplified Spontaneous Emission (SASE) regime indicate a large sensitivity of the gain to the degree of transverse overlap (and associated phase coherence) between the electron and photon beams traveling down the insertion device. Simulations of actual systems imply that accurate detection and correction for this relative loss of overlap, rather than correction for the absolute departure of the electron beam from a fixed axis, is the preferred function of an FEL amplifier's Beam Position Monitor (BPM) and corrector systems. In this note we propose a novel diffractive BPM with the capability of simultaneously detecting and resolving the absolute (and relative) transverse positions and profiles of electron and x-ray beams co-propagating through an undulator. We derive the equations governing the performance of the BPM and examine its predicted performance for the SLAC Linac Coherent Light Source (LCLS), viz., for profiling multi-GeV electron bunches co-propagating with one-to-several-hundred keV x-ray beams. Selected research and development (r&d) tasks for fabricating and testing the proposed BPM are discussed.
No abstract prepared.
Abstract Not Provided
Abstract Not Provided
Abstract Not Provided