Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Control System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Autonomous System Inference, Trojan, and Adversarial Reprogramming Attack and Defense (Final)

In the world of ever-advancing technology, Autonomous Systems (AS) find extensive application, bolstering functionalities of critical infrastructures such as nuclear power plants. These systems, however, are increasingly becoming a target for nefarious activities, namely through inference attacks, trojan attacks, and adversarial reprogramming. This paper delves into a comprehensive exploration of machine learning (ML)-driven autonomous control systems within advanced nuclear reactor designs, revealing the vulnerabilities and proposing strategies for defense against potential cyber-attacks. Advanced cyber-attacks against critical infrastructure and the energy sector are becoming more common. With the invention of autonomous control systems (ACS) within advanced nuclear reactor designs, system designers, reactor operators, and regulators must consider cybersecurity during the design and operational phases. This article provides a cyber threat assessment of machine learning (ML)- based digital twinning (DT) technologies in the context of advanced reactor ACS. A cyber-physical testbed was created to emulate nuclear reactor digital instrumentation and controls (I&C) and act as a basis for the ACS. The ACS was designed as two plant-level DTs predicting reactor malfunctions and determining control actions and two component-level DTs responsible for classifying component states and forecasting component inputs and outputs (I/O). Two duplicate ACS designs– one using a traditional ML framework and one using an automated ML (AutoML) framework– were created and tested against cyber-attacks on training data, real-time process data, and ML model architectures to determine their respective qualitative cyber-risk in terms of likelihood and impact. Both frameworks showed similar cyber-resilience against training, real-time, and ML architecture attacks, proving that neither is inherently more secure. Recommended safeguard and security measures are posed to system designers, reactor operators, and regulators to maintain the cybersecurity of ML-based DT technologies such as ACS, prompting a holistic view of shared responsibility for maintaining cyber-secure ML-based systems. As global reliance on generation III reactors begins to be critically assessed, the evolution towards advanced reactor systems utilizing digital instrumentation and controls (I&C) becomes not merely preferable, but essential. The integration of semi and fully autonomous control systems (ACS), powered by digital I&C and machine learning (ML)-based digital twinning (DT) technologies, emerges as a potent strategy to mitigate operations and maintenance costs, thereby enhancing the economic feasibility of novel reactor designs. However, with a staggering 500% and 380% increase in cyber-attacks reported against the energy sector by the United States Department of Energy (DoE) and the European Union respectively, a surge in cyber vulnerabilities specifically targeting the nuclear industry has been 2 markedly observed. Notable incidents, such as the W32.Ramnit spyware infiltration at the Gundremmingen nuclear power plant in Germany and the Dtrack spyware intrusion at the Kudankulam nuclear power plant in India, while not directly compromising core industrial control systems (ICS), underscore a compelling necessity to fortify cybersecurity protocols in safeguarding reactor systems against increasingly adept digital adversaries. In light of this, our investigation extends beyond conventional cybersecurity parameters, diving into the intricate web of potential vulnerabilities woven into ML-based DTs and ACS in advanced reactor systems. A crafted cyber-physical testbed and preliminary ACS were devised to act as a mirror, reflecting potential configurations of advanced reactor control designs. Moreover, this study is intertwined with a scrutinization of ML models, developed either through conventional, manually tuned methodologies or via automated means through AutoML, probing into their cyber-risk profiles within operational technology (OT) environments. Expanding on this, two distinct ACS blueprints were forged – one navigating through the corridors of traditional ML and the other traversing the path of AutoML – in an effort to holistically encapsulate the considerations pivotal to ML-based DT control system design. Employing the SANS Institute Industrial Control System (ICS) Kill Chain and the MITRE ATT&CK Tactics, Techniques, and Procedures (TTP) framework, a structured analysis was conducted, launching three targeted attacks against the training dataset, real-time dataset, and ML models, therein dissecting the potential cyber-attack implications against both ML frameworks within an ACS milieu. It is essential to note that three distinct categories of attacks were conducted against both ACS configurations, each encompassing three distinct ML-based DTs, cumulating in a total of 18 varied attacks. This exploration extends into the realms of Autonomous System Inference, Trojan, and Adversarial Reprogramming Attack and Defense, unraveling vulnerabilities, and opportunities for fortified defenses against such intrusions, particularly where ML-driven technologies, and by extension, ACS, are deployed. Final recommendations, articulated through a lens of security, safeguard, and implementation considerations, are presented for both traditional and AutoML models, anchoring upon the existing knowledge landscape and ML-based DT modeling for ACS, and are offered as a beacon to guide the nuclear industry through the intricate cybersecurity challenges that lie ahead.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Dynamic homotopy and landscape dynamical set topology in quantum control

We examine the topology of the subset of controls taking a given initial state to a given final state in quantum control, where 'state' may mean a pure state Double-Vertical-Line {psi}>, an ensemble density matrix {rho}, or a unitary propagator U(0, T). The analysis consists in showing that the endpoint map acting on control space is a Hurewicz fibration for a large class of affine control systems with vector controls. Exploiting the resulting fibration sequence and the long exact sequence of basepoint-preserving homotopy classes of maps, we show that the indicated subset of controls is homotopy equivalent to the loopspace of the state manifold. This not only allows us to understand the connectedness of 'dynamical sets' realized as preimages of subsets of the state space through this endpoint map, but also provides a wealth of additional topological information about such subsets of control space.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Prototypic Enhanced Risk Monitor Framework and Evaluation - Advanced Reactor Technology Milestone: M3AT-15PN2301054

This research report summaries the development and evaluation of a prototypic enhanced risk monitor (ERM) methodology (framework) that includes alternative risk metrics and uncertainty analysis. This updated ERM methodology accounts for uncertainty in the equipment condition assessment (ECA), the prognostic result, and the probabilistic risk assessment (PRA) model. It is anticipated that the ability to characterize uncertainty in the estimated risk and update the risk estimates in real time based on equipment condition assessment (ECA) will provide a mechanism for optimizing plant performance while staying within specified safety margins. These results (based on impacting active component O&M using real-time equipment condition information) are a step towards ERMs that, if integrated with AR supervisory plant control systems, can help control O&M costs and improve affordability of advanced reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Tangible Solutions for Grid Operation Upgrade

Many countries worldwide are setting clean energy targets to decarbonize the energy sector and add higher wind and solar capacities. Given their distributed nature, variable renewable energy (VRE) assets can have unique grid integration considerations, and require grid operation practices to be modernized. When transitioning to higher renewable energy levels, many system operators configure a dedicated renewable energy desk to manage renewable energy resource operation in the system control center. Further, system operation planning is conducted with VRE and load forecasting to enable reliable real-time system operation. NREL has partnered with many system operators in the region to identify appropriate technology and grid modernization solutions. NREL and partners from system operators in the region will present on the challenges and some solutions that have been applied and share best practices such as energy management system upgrades, VRE forecasting framework, grid flexibility improvements, and staff training.

emerging economies↗

Laser interlock system

A method and device for providing a laser interlock having a first optical source, a first beam splitter, a second optical source, a detector, an interlock control system, and a means for producing dangerous optical energy. The first beam splitter is optically connected to the first optical source, the first detector and the second optical source. The detector is connected to the interlock control system. The interlock control system is connected to the means for producing dangerous optical energy and configured to terminate its optical energy production upon the detection of optical energy at the detector from the second optical source below a predetermined detector threshold. The second optical source produces an optical energy in response to optical energy from the first optical source. The optical energy from the second optical source has a different wavelength, polarization, modulation or combination thereof from the optical energy of the first optical source.

42 ENGINEERING↗

Demonstration Assessment of LED Roadway Lighting - NE Cully Boulevard, Portland, OR

A new roadway lighting demonstration project was initiated in late 2010, which was planned in conjunction with other upgrades to NE Cully Boulevard, a residential collector road in the northeast area of Portland, OR. With the NE Cully Boulevard project, the Portland Bureau of Transportation hoped to demonstrate different light source technologies and different luminaires side-by-side. This report documents the initial performance of six different newly installed luminaires, including three LED products, one induction product, one ceramic metal halide product, and one high-pressure sodium (HPS) product that represented the baseline solution. It includes reported, calculated, and measured performance; evaluates the economic feasibility of each of the alternative luminaires; and documents user feedback collected from a group of local Illuminating Engineering Society (IES) members that toured the site. This report does not contain any long-term performance evaluations or laboratory measurements of luminaire performance. Although not all of the installed products performed equally, the alternative luminaires generally offered higher efficacy, more appropriate luminous intensity distributions, and favorable color quality when compared to the baseline HPS luminaire. However, some products did not provide sufficient illumination to all areas—vehicular drive lanes, bicycle lanes, and sidewalks—or would likely fail to meet design criteria over the life of the installation due to expected depreciation in lumen output. While the overall performance of the alternative luminaires was generally better than the baseline HPS luminaire, cost remains a significant barrier to widespread adoption. Based on the cost of the small quantity of luminaires purchased for this demonstration, the shortest calculated payback period for one of the alternative luminaire types was 17.3 years. The luminaire prices were notably higher than typical prices for currently available luminaires purchased in larger quantities. At prices that are more typical, the payback would be less than 10 years. In addition to the demonstration luminaires, a networked control system was installed for additional evaluation and demonstration purposes. The capability of control system to measure luminaire input power was explored in this study. A more exhaustive demonstration and evaluation of the control system will be the subject of future GATEWAY report(s).

Comparison to High Pressure Sodium Lighting↗

Communication devices for network-hopping communications and methods of network-hopping communications

Wireless communication devices include a software-defined radio coupled to processing circuitry. The system controller is configured to execute computer programming code. Storage media is coupled to the system controller and includes computer programming code configured to cause the system controller to configure and reconfigure the software-defined radio to operate on each of a plurality of communication networks according to a selected sequence. Methods for communicating with a wireless device and methods of wireless network-hopping are also disclosed.

97 MATHEMATICS AND COMPUTING↗

Advanced Reactor Safeguards & Security Program: Cybersecurity Scenarios

The use of digital control systems and automation in advanced nuclear power systems introduces different types of vulnerabilities compared to legacy (i.e. analog) control systems that cyber adversaries can exploit. These vulnerabilities pose a challenge to reactor operators and cyber operations staff due to the dynamic nature of the event in which a human response or a lack of response can potentially evolve into a worsening plant condition. Using the Department of Homeland Security Cyber and Infrastructure Security Agency’s (CISA) critical infrastructure exercise framework, this document presents several cyber security scenarios typical of digital control systems that could be used in advanced reactor designs. These scenarios can be used in tabletop exercises to evaluate cyber security posture or conduct training on different aspects of cyber security, including detection, threat hunting using indicators of compromise, evaluating incident response, risk mitigation, incident reporting, information sharing and recovery.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Methodological demonstration of laser beam pointing control for space gravitational wave detection missions

In space laser interferometer gravitational wave (G.W.) detection missions, the stability of the laser beam pointing direction has to be kept at 10 nrad/√Hz. Otherwise, the beam pointing jitter noise will dominate the noise budget and make the detection of G.W. impossible. Disturbed by the residue non-conservative forces, the fluctuation of the laser beam pointing direction could be a few μrad/√Hz at frequencies from 0.1 mHz to 10 Hz. Therefore, the laser beam pointing control system is an essential requirement for those space G.W. detection missions. An on-ground test of such beam pointing control system is performed, where the Differential Wave-front Sensing technique is used to sense the beams pointing jitter. An active controlled steering mirror is employed to adjust the beam pointing direction to compensate the jitter. The experimental result shows that the pointing control system can be used for very large dynamic range up to 5 μrad. At the interested frequencies of space G.W. detection missions, between 1 mHz and 1 Hz, beam pointing stability of 6 nrad/√Hz is achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modular thermal and radiation shielding with passive heat removal

A housing assembly configured to house a reactor is disclosed. The housing assembly includes a plurality of modular walls configured to surround the reactor and a passive temperature control system. The plurality of modular walls includes a first modular wall. The passive temperature control system is coupled to the first modular wall. The passive temperature control system is configured to transfer heat between the reactor and an area around the housing assembly.

Trupiano, Anthony G.↗

A fresh look at electron cyclotron current drive power requirements for stabilization of tearing modes in ITER

ITER is an international project to design and build an experimental fusion reactor based on the “tokamak” concept. ITER relies upon localized electron cyclotron current drive (ECCD) at the rational safety factor q=2 to suppress or stabilize the expected poloidal mode m=2, toroidal mode n=1 neoclassical tearing mode (NTM) islands. Such islands if unmitigated degrade energy confinement, lock to the resistive wall (stop rotating), cause loss of “H-mode” and induce disruption. The International Tokamak Physics Activity (ITPA) on MHD, Disruptions and Magnetic Control joint experiment group MDC-8 on Current Drive Prevention/Stabilization of Neoclassical Tearing Modes started in 2005, after which assessments were made for the requirements for ECCD needed in ITER, particularly that of rf power and alignment on q=2 [1]. Narrow well-aligned rf current parallel to and of order of one percent of the total plasma current is needed to replace the “missing” current in the island O-points and heal or preempt (avoid destabilization by applying ECCD on q=2 in absence of the mode) the island [2-4]. This paper updates the advances in ECCD stabilization on NTMs learned in DIII-D experiments and modeling during the last 5 to 10 years as applies to stabilization by localized ECCD of tearing modes in ITER. This includes the ECCD (inside the q=1 radius) stabilization of the NTM “seeding” instability known as sawteeth (m/n=1/1) [5]. Recent measurements in DIII-D show that the ITER-similar current profile is classically unstable, curvature stabilization must not be neglected, and the small island width stabilization effect from helical ion polarization currents is stronger than was previously thought [6]. The consequences of updated assumptions in ITER modeling of the minimum well-aligned ECCD power needed are all-in-all favorable (and well-within the ITER 24 gyrotron capability) when all effects are included. However, a “wild card” may be broadening of the localized ECCD by the presence of the island; various theories predict broadening could occur and there is experimental evidence for broadening in DIII-D. Wider than now expected ECCD in ITER would make alignment easier to do but weaken the stabilization and thus require more rf power. In addition to updated modeling for ITER, advances in the ITER-relevant DIII-D ECCD gyrotron launch mirror control system hardware and real-time plasma control system have been made [7] and there are plans for application in DIII-D ITER demonstration discharges.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enhancing the Operational Resilience of Advanced Reactors with Digital Twins by Recurrent Neural Networks

Because of a lack of operational data and uncertainty in evaluation model for abnormal and accident scenarios, the established operating procedures can be biased in characterizing the reactor states and ensuring operational resilience. To reduce uncertainty associated with actual plant conditions, digital twin (DT) technology is suggested to support operator’s decision-making by effectively extracting and using knowledge of the current and future plant states from the knowledge base. This study first builds a knowledge base based on the characterization of issue space and the simulation tool. Next, this study discusses diagnosis and prognosis DTs for enhancing operational resilience by recovering the complete states of reactors and by predicting the future reactor behaviors. Finally, the decision-making module of the control system can determine the optimal control strategy that meets operational goals during loss-of-flow scenarios. To demonstrate and evaluate the DTs capability for supporting the operations of nuclear reactors, this study develops and assesses both the diagnosis and prognosis DTs in a nearly autonomous management and control system for an Experimental Breeder Reactor-II simulator during different loss-of-flow scenarios.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Real-Time Defect Correction in Large-Scale Polymer Additive Manufacturing via Thermal Imaging and Laser Profilometer

Defects can result in a failed part and are costly in terms of time and material. This cost is even greater in the context of large-scale additive manufacturing where the objects can be very large. As a result, a great deal of research has focused on defect identification and mitigation. To address defects during object construction, researchers at Oak Ridge National Laboratory’s Manufacturing Demonstration Facility investigated an in-situ control system comprised of two sensors: a thermal camera and laser profilometer. This control system adjusted material flow and build speed to mitigate three types of defects: low layer times, underfill, and overfill. Several test objects were constructed. The control system was found to adjust build parameters to handle low layer times of approximately 15 seconds and height deviations from -100% underfill (the absence of a layer) to 50% overfill. Within two layers, height deviations could be returned to within 10% of the expected layer height. Further, preliminary results suggest the system can compensate for uneven build surfaces.

Borish, Michael↗

SU-E-T-267: Development of the Compact Graphite Calorimetry System for the High Energy Photon Beam

Purpose: Graphite calorimeter systems are used for the absolute photon dosimetry. But many electronics are demanded in order to measure the tiny temperature changes. Minimizing the control system is needed to make a portable graphite calorimeter. Methods: A Domen-type graphite calorimetry system is constructing to measure the absorbed dose of the high energy photon beam. The graphite calorimeter divided into three parts, Core, Jacket, and Shield. In order to measure the temperature rising of the core due to the radiation accurately, the temperatures of the jacket and the shield should be controlled properly. A commercial temperature controller (Model 350, Lake Shore Cryogenics) was used to minimize the size of control system for making a portable graphite calorimetry system at the cost of the measurement uncertainty. The PID control of the jacket is conducted by the software (LabView) and Model 350 maintain the temperature of shield. Results: Our design value of the heat deposition power in the core is 0.04 mW for the dose rate of 3 Gy/min where the temperature sensitivity of the graphite is 1.4 mK/Gy. While the residuals of the Steinhart-hart equation fitting for the core thermistor were less than 0.1 mK, the temperature resolution of Model 350 is 1 mK. The temperature of the shield was kept within the 5 mK when the room temperature variation was about 0.5 K. Conclusion: The resolution of Model 350 for the temperature measurement and control is not good enough as the control system for the compact graphite calorimetry system. But The performance of Model 350 is good enough to maintain the temperature of the shield constantly. The Model 350 will be replaced by the AC resistance bridge (Model 372, Lake Shore Cryogenics) for the core temperature measurement and the jacket control.

07 ISOTOPE AND RADIATION SOURCES↗

Scalable, Physical Effects Measurable Microgrid for Cyber Resilience Analysis (SPEMMCRA)

The ability to advance state of the art automated protections for industrial control systems (ICS) has as a precursor in the ability to understand the tradeoff space. That is, to enable a cyber feedback loop in a control system environment you must first consider both the security mitigation available, the benefits and the impacts to the control system functionality when the mitigation is used. More damaging impacts could be precipitated that the mitigation was intended to rectify. This paper details networked ICS that controls a simulation of the frequency response represented with the swing equation. The microgrid loads and base generation can be balanced through the control of an emulated battery and power inverter. The simulated plant, which is implemented in Raspberry Pi computers, provides an inexpensive platform to realize the physical effects of cyber attacks to show the tradeoffs of available mitigatoins. This network design can include a commercial ICS controller to introduce real world implementation of feedback controls, and provides a scalable, physical effects measurable Microgrid for cyber resilience analysis (SPEMMCRA).

42 ENGINEERING↗

Guest Editorial: Advanced Data-Analytics for Power System Operation, Control, and Enhanced Situational Awareness

Along with the smart grid development, modern power systems are entering a ‘data-intensive’ era. A vast volume of data from power grids is being collected through advanced sensing and communication technologies, such as smart metering data, phasor measurement data, as well as meteorological data (e.g., wind speed and solar irradiance) related to renewable power generation. Such data contains comprehensive information about the power system covering equipment's health status, power grid's static and dynamic characteristics, renewable power generation, customers’ electricity usage pattern, etc. Therefore, advanced data-analytics techniques are needed to convert such data to knowledge for practical applications. In line with the trend of widespread data-driven applications in power systems, this Special Issue aims to present state-of-the-art research works on advanced data-analytics for power system's operation, control, and situational awareness. There are in total twenty-six papers accepted for publication in this Special Issue through careful peer reviews and revisions. Under the overarching theme of data-driven applications in power systems, the selected papers are broadly categorised into five topics. The summary of every topic is given below. You are, however, strongly encouraged to read the full paper if interested.

Xu, Yan↗

Cryogenic Performance of the SPT-SLIM Receiver

The South Pole Telescope Shirokoff Line Intensity Mapper (SPT-SLIM) is a millimeter-wave line-intensity mapping experiment, deployed on the South Pole Telescope (SPT) during the 2024-2025 Austral Summer season. This pathfinder experiment serves to demonstrate the on-sky operation of multi-pixel on-chip spectrometer technology. We present on the cryogenic performance of the SPT-SLIM receiver for this Year 1 observing campaign. The SPT-SLIM receiver utilizes an Adiabatic Demagnetization Referigerator (ADR) for cooling the focal plane of superconducting filterbank spectrometers to a temperature of 150mK. We demonstrate stable thermal performance of the focal plane module during observing operations in line with thermal modelling, enabling a cryogenic operation efficiency above 80%. We also report on the receiver control system design utilizing the Observatory Control System (OCS) platform for automated cryogenic operation on the SPT.

Young, Matthew [Fermilab]↗