Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coils”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Skip residues modulate the structural properties of the myosin rod and guide thick filament assembly

The rod of sarcomeric myosins directs thick filament assembly and is characterized by the insertion of four skip residues that introduce discontinuities in the coiled-coil heptad repeats. We report in this paper that the regions surrounding the first three skip residues share high structural similarity despite their low sequence homology. Near each of these skip residues, the coiled-coil transitions to a nonclose-packed structure inducing local relaxation of the superhelical pitch. Moreover, molecular dynamics suggest that these distorted regions can assume different conformationally stable states. In contrast, the last skip residue region constitutes a true molecular hinge, providing C-terminal rod flexibility. Assembly of myosin with mutated skip residues in cardiomyocytes shows that the functional importance of each skip residue is associated with rod position and reveals the unique role of the molecular hinge in promoting myosin antiparallel packing. By defining the biophysical properties of the rod, the structures and molecular dynamic calculations presented here provide insight into thick filament formation, and highlight the structural differences occurring between the coiled-coils of myosin and the stereotypical tropomyosin. Finally, in addition to extending our knowledge into the conformational and biological properties of coiled-coil discontinuities, the molecular characterization of the four myosin skip residues also provides a guide to modeling the effects of rod mutations causing cardiac and skeletal myopathies.

59 BASIC BIOLOGICAL SCIENCES↗

Techniques for the measurement of disruption halo currents in the National Spherical Torus Experiment

This paper describes techniques for measuring halo currents, and their associated toroidal peaking, in the National Spherical Torus Experiments [M. Ono et al., Nucl. Fusion 40, 557 (2000)]. The measurements are based on three techniques: (1) measurement of the toroidal field created by the poloidal halo current, either with segmented Rogowski coils or discrete toroidal field sensors, (2) the direct measurement of halo currents into specially instrument tiles, and (3) small Rogowski coils placed on the mechanical supports of in-vessel components. For the segmented Rogowski coils and discrete toroidal field detectors, it is shown that the toroidal peaking factor inferred from the data is significantly less than the peaking factor of the underlying halo current distribution, and a simple model is developed to relate the two. For the array of discrete toroidal field detectors and small Rogowski sensors, the compensation steps that are used to isolate the halo current signal are described. The electrical and mechanical design of compact under-tile resistive shunts and mini-Rogowski coils is described. Example data from the various systems are shown.

42 ENGINEERING↗

Test results of a Nb 3 Al/Nb 3 Sn subscale magnet for accelerator application

The High Energy Accelerator Research Organization (KEK) has been developing a Nb 3 Al and Nb 3 Sn subscale magnet to establish the technology for a high-field accelerator magnet. The development goals are a feasibility demonstration for a Nb 3 Al cable and the technology acquisition of magnet fabrication with Nb 3 Al superconductors. KEK developed two double-pancake racetrack coils with Rutherford-type cables composed of 28 Nb 3 Al wires processed by rapid heating, quenching, and transformation in collaboration with the National Institute for Materials Science and the Fermi National Accelerator Laboratory. The magnet was fabricated to efficiently generate a high magnetic field in a minimum-gap common-coil configuration with two Nb 3 Al coils sandwiched between two Nb 3 Sn coils produced by the Lawrence Berkeley National Laboratory. A shell-based structure and a “bladder and key” technique have been used for adjusting coil prestress during both the magnet assembly and the cool down. In the first excitation test of the magnet at 4.5 K performed in June 2014, the highest quench current of the Nb 3 Sn coil, i.e., 9667 A, was reached at 40 A/s corresponding to 9.0 T in the Nb 3 Sn coil and 8.2 T in the Nb 3 Al coil. The quench characteristics of the magnet were studied.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Crystal structure of the human glial fibrillary acidic protein 1B domain

Highlights: • The first crystal structure of the human GFAP 1B domain was determined. • Two parallel coiled-coils pack together lengthwise in an antiparallel configuration. • H-bonds, salt bridges, and hydrophobic interactions stabilize the homotetramer. • Alexander disease mutations disrupt the interactions and the GFAP filament network. Glial fibrillary acidic protein (GFAP) is a homopolymeric type III intermediate filament (IF) that plays essential roles in cell migration, mitosis, development, and signaling in astrocytes and a specific type of glial cells. Its overexpression and genetic mutations lead to abnormal IF networks and accumulation of Rosenthal fibers, which results in the fatal neurodegenerative disorder Alexander disease. Herein, we present the first crystal structure of human GFAP spanning the central coiled-coil 1B domain at 2.5 Å resolution. The domain forms a tetramer comprising two equivalent parallel coiled-coil dimers that pack together in an antiparallel manner. Its assembly is stabilized by extensive networks of intermolecular hydrogen bonds, salt bridges, and hydrophobic interactions. Furthermore, mapping of the GFAP mutations associated with Alexander disease reveals that most involve residues buried in the core of the interface, and are likely to disrupt the intermolecular interactions and/or introduce steric clashes, thereby decreasing GFAP solubility and promoting aggregation. Based on our structural analysis and previous biochemical studies, we propose that GFAP assembles in the A11 mode in which coiled-coil 1B dimers lie in close axial proximity in an antiparallel fashion to provide a stable tetrameric platform for the organization of the GFAP filament.

60 APPLIED LIFE SCIENCES↗

Structual and Molecular Basis of the Assembly of the TRPP2/PKD1 Complex

Mutations in PKD1 and TRPP2 account for nearly all cases of autosomal dominant polycystic kidney disease (ADPKD). These 2 proteins form a receptor/ion channel complex on the cell surface. Using a combination of biochemistry, crystallography, and a single-molecule method to determine the subunit composition of proteins in the plasma membrane of live cells, we find that this complex contains 3 TRPP2 and 1 PKD1. A newly identified coiled-coil domain in the C terminus of TRPP2 is critical for the formation of this complex. This coiled-coil domain forms a homotrimer, in both solution and crystal structure, and binds to a single coiled-coil domain in the C terminus of PKD1. Mutations that disrupt the TRPP2 coiled-coil domain trimer abolish the assembly of both the full-length TRPP2 trimer and the TRPP2/PKD1 complex and diminish the surface expression of both proteins. These results have significant implications for the assembly, regulation, and function of the TRPP2/PKD1 complex and the pathogenic mechanism of some ADPKD-producing mutations.

36 MATERIALS SCIENCE↗

Identification of important error fields in stellarators using the Hessian matrix method

Error fields are predominantly attributed to inevitable coil imperfections. Controlling error fields during coil fabrication and assembly is crucial for stellarators. Excessively tight coil tolerance increases time and cost, and, in part, led to the cancellation of the National Compact Stellarator Experiment and delay of W7-X. In this paper, we improve the recently proposed Hessian matrix method to rapidly identify important coil deviations. Two of the most common figures of merit, magnetic island size and quasi-symmetry, are analytically differentiated over coil parameters. By extracting the eigenvectors of the Hessian matrix, we can directly identify sensitive coil deviations in the order of the eigenvalues. The new method is applied to the upcoming Chinese First Quasi-axisymmetric Stellarator configuration. Important perturbations that enlarge n/m = 4/11 islands and deteriorate quasi-axisymmetry of the magnetic field are successfully determined. The results suggest each modular coil should have separate tolerance and some certain perturbation combinations will produce significant error fields. By relaxing unnecessary coil tolerance, this method will hopefully lead to a substantial reduction in time and cost.

79 ASTRONOMY AND ASTROPHYSICS↗

Dynamics of laser-generated magnetic fields using long laser pulses

In this work, we report on the experimental investigation of magnetic field generation with a half-loop gold sheet coil driven by long-duration (10 ns) and high-power (0.5 TW) laser pulses. The amplitude of the magnetic field was characterized experimentally using proton deflectometry. The field rises rapidly in the first 1 ns of laser irradiation, and then increases slowly and continuously up to 10 ns during further laser irradiation. The transient dynamics of current shape were investigated with a two-dimensional (2D) numerical simulation that included Ohmic heating of the coil and the resultant change of electrical resistivity determined by the coil material temperature. The numerical simulations show rapid heating at the coil edges by current initially localized at the edges. This current density then diffuses to the central part of the sheet coil in a way that depends both on normal current diffusion as well as temporal changes of the coil resistance induced by the Ohmic heating. The measured temporal evolution of the magnetic field is compared with a model that determines a solution to the coil current and voltage that is consistent with a plasma diode model of the drive region and a 2D simulation of current diffusion and dynamic resistance due to Ohmic heating in the laser coil.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mechanical Performance of the LARP Nb3Sn Quadrupole Magnet LQS01

As part of the effort towards the development of Nb{sub 3}Sn magnets for future LHC luminosity upgrades, the LHC Accelerator Research Program (LARP) has fabricated and tested the quadrupole magnet LQS01. The magnet implements 3.4 m long Nb{sub 3}Sn coils contained in a support structure characterized by an external aluminum shell segmented in four sections. The room temperature pre-load of the structure is obtained by shimming load keys through bladders, pressurized during the loading operations and removed before cool-down. Temperature compensated strain gauges, mounted on structure components and coil poles, monitor the magnet's mechanical behavior during assembly, cool-down and, excitation. During the first test, LQS01 reached the target gradient of 200 T/m; the gauge data indicated that the aluminum shell was pre-tensioned to the target value estimated by numerical models, but a lack of pre-load was measured in the coil inner layer during ramping. As a result, the test was interrupted and the magnet disassembled, and inspected. A second test (LQS01b) was then carried out following a re-loading of the magnet. The paper reports on the strain gauge results of the first test and the analysis performed to identify corrective actions to improve the coil pre-stress distribution. The mechanical performance of the magnet during the second cool-down and test is then presented and discussed.

43 PARTICLE ACCELERATORS↗

Heat Treatment Optimization of Rutherford Cables for a 15 T Nb 3 Sn Dipole Demonstrator

FNAL has been developing a 15 T Nb 3 Sn dipole demonstrator for a future Very High Energy pp Collider based on an optimized 60-mm aperture 4-layer “cos-theta” coil. In order to increase magnet efficiency, we graded the coil by using two cables with same 15 mm width and different thicknesses made of two different Restacked Rod Process (RRP®) wires. Due to the non-uniform field distribution in dipole coils the maximum field in the inner coil will reach 15-16 T, whereas the maximum field in the outer coil is 12-13 T. In preparation for the 15 T dipole coil reaction, heat treatment studies were performed on strands extracted from these cables with the goal of achieving the best coil performance in the corresponding magnetic fields. Particularly, the effect of maximum temperature and time on the cable critical current was studied to take into account actual variations of these parameters during coil reaction. In parallel and in collaboration with OST, development was performed on optimizing Nb 3 Sn RRP® wire design and layout. Index Terms— Accelerator magnet, critical current density, Nb 3 Sn strand, Rutherford cable.

43 PARTICLE ACCELERATORS↗

Mechanical Utility Structure for Testing High Field Superconducting Dipole Magnets

The U.S. Magnet Development Program (MDP) collaboration is designing a utility mechanical structure for testing various high-field superconducting dipole coils. The design uses a shell-based structure concept, which allows applying preload in two steps: During a room temperature assembly and during a cool down to a cryogenic temperature. The structure is designed to accommodate various coil designs - including Nb 3 Sn Cosine Theta (CT) and Canted CT magnets as well as hybrid magnets with high temperature superconductor cables. Superconducting coils, enclosed by bolted pads to form an octagonal coil pack, will be inserted into a reusable yoke-shell subassembly and precisely preloaded during the assembly using a bladder-and-key technology. Due to a differential thermal contraction between an external aluminum shell and the magnet core, the coil preload increases during the cool down up to level required for 17-T excitation. Such a reusable structure will serve as a testing fixture supporting goals of the MDP program, decreasing cost and simplifying coil performance testing at different preload levels. We present a finite-element analysis of the structure preloading various coil designs and examine the predicted coil stress at each step of the magnet assembly and excitation.

43 PARTICLE ACCELERATORS↗

Magnetic and Mechanical Design of a 15-T Large Aperture Dipole Magnet for Cable Testing

© 2019 IEEE. A large aperture Nb 3 Sn dipole is proposed to replace the magnet assembly of EDIPO, which was irreversibly damaged in 2016. The goal is to generate a background field of 15 T at 4.2 K in a clear aperture of approximately 100×150 mm 2 and over a uniform length of 1000 mm in order to test superconducting cables for both fusion and high-energy physics applications. The magnet features a block-type coil design wound with wide Rutherford cable (two alternative coil cross sections are considered) and supported by a mechanical structure based on keys-and-bladders technology. In the end regions, the coils tilt up (flare) through a hard-way bend of the cables to provide room for the test well, following a layout already adopted in the LBNL HD2 and CERN-CEA FRESCA2 magnets. The two considered coil design alternatives aim at minimizing the mechanical stress in the coil windings. One coil pack design makes the use of two double pancake coils per pole, whereas the other alternative features three double pancakes per pole. Both design options are presented focusing on the results of numerical computations carried out with finite-element models to investigate peak stresses in the coils during room-temperature pre-loading, cool down, and powering.

Sarasola, Xabier (ORCID:0000000324306939)↗

SU-E-J-214: MR Protocol Development to Visualize Sirius MRI Markers in Prostate Brachytherapy Patients for MR-Based Post-Implant Dosimetry

Purpose: The current CT-based post-implant dosimetry allows precise seed localization but limited anatomical delineation. Switching to MR-based post-implant dosimetry is confounded by imprecise seed localization. One approach is to place positive-contrast markers (Sirius) adjacent to the negative-contrast seeds. This patient study aims to assess the utility of a 3D fast spoiled gradient-recalled echo (FSPGR) sequence to visualize Sirius markers for post-implant dosimetry. Methods: MRI images were acquired in prostate implant patients (n=10) on Day 0 (day-of-implant) and Day 30. The post-implant MR protocol consisted of 3D T2-weighted fast-spin-echo (FSE), T2-weighted 2D-FSE (axial) and T1-weighted 2D-FSE (axial/sagittal/coronal). We incorporated a 3D-FSPGR sequence into the post-implant MR protocol to visualize the Sirius markers. Patients were scanned with different number-of-excitations (6, 8, 10), field-of-view (10cm, 14cm, 18cm), slice thickness (1mm, 0.8mm), flip angle (14 degrees, 20 degrees), bandwidth (122.070 Hz/pixel, 325.508 Hz/pixel, 390.625 Hz/pixel), phase encoding steps (160, 192, 224, 256), frequency-encoding direction (right/left, anterior/posterior), echo-time type (minimum-full, out-of-phase), field strength (1.5T, 3T), contrast (with, without), scanner vendor (Siemens, GE), coil (endorectal-coil only, endorectal-and-torso-coil, torsocoil only), endorectal-coil filling (30cc, 50cc) and endorectal-coil filling type (air, perfluorocarbon [PFC]). For post-implant dosimetric evaluation with greater anatomical detail, 3D-FSE images were fused with 3D-FSPGR images. For comparison with CT-based post-implant dosimetry, CT images were fused with 3D-FSPGR images. Results: The 3D-FSPGR sequence facilitated visualization of markers in patients. Marker visualization helped distinguish signal voids as seeds versus needle tracks for more definitive MR-based post-implant dosimetry. On the CT-MR fused images, the distance between the seed on CT to MR images was 3.2±1.6mm in patients with no endorectal coil, 2.3±0.8mm in patients with 30cc-PFC-filled endorectal-coil and 5.0±1.8mm in patients with 50cc-PFC-filled endorectal-coil. Conclusion: An MR protocol to visualize positive-contrast Sirius markers to assist in the identification of negative-contrast seeds was demonstrated. S Frank is a co-founder of C4 Imaging LLC, the manufacturer of the MRI markers.

60 APPLIED LIFE SCIENCES↗

SDI CFD MODELING ANALYSIS

The Savannah River Remediation (SRR) Organization requested that Savannah River National Laboratory (SRNL) develop a Computational Fluid Dynamics (CFD) method to mix and blend the miscible contents of the blend tanks to ensure the contents are properly blended before they are transferred from the blend tank; such as, Tank 50H, to the Salt Waste Processing Facility (SWPF) feed tank. The work described here consists of two modeling areas. They are the mixing modeling analysis during miscible liquid blending operation, and the flow pattern analysis during transfer operation of the blended liquid. The transient CFD governing equations consisting of three momentum equations, one mass balance, two turbulence transport equations for kinetic energy and dissipation rate, and one species transport were solved by an iterative technique until the species concentrations of tank fluid were in equilibrium. The steady-state flow solutions for the entire tank fluid were used for flow pattern analysis, for velocity scaling analysis, and the initial conditions for transient blending calculations. A series of the modeling calculations were performed to estimate the blending times for various jet flow conditions, and to investigate the impact of the cooling coils on the blending time of the tank contents. The modeling results were benchmarked against the pilot scale test results. All of the flow and mixing models were performed with the nozzles installed at the mid-elevation, and parallel to the tank wall. From the CFD modeling calculations, the main results are summarized as follows: (1) The benchmark analyses for the CFD flow velocity and blending models demonstrate their consistency with Engineering Development Laboratory (EDL) and literature test results in terms of local velocity measurements and experimental observations. Thus, an application of the established criterion to SRS full scale tank will provide a better, physically-based estimate of the required mixing time, and elevation of transfer pump for minimum sludge disturbance. (2) An empirical equation for a tank with no cooling coils agrees reasonably with the current modeling results for the dual jet. (3) From the sensitivity study of the cooling coils, it was found that the tank mixing time for the coiled tank was about two times longer than that of the tank fluid with no coils under the 1/10th scale, while the coiled tank required only 50% longer than the one without coils under the full scale Tank 50H. In addition, the time difference is reduced when the pumping U{sub o}d{sub o} value is increased for a given tank. (4) The blending time for T-shape dual jet pump is about 20% longer than that of 15{sup o} upward V-shape pump under the 1/10th pilot-scale tank, while the time difference between the two pumps is about 12% for the full-scale Tank 50H. These results are consistent with the literature information. (5) A transfer pump with a solid-plate suction screen operating at 130 gpm can be located 9.5 inches above settled sludge for 2 in screen height in a 85 ft waste tank without disturbing any sludge. Detailed results are summarized in Table 13. Final pump performance calculations were made by using the established CW pump design, and operating conditions to satisfy the two requirements of minimum sludge disturbance, and adequate blending of tank contents. The final calculation results show that the blending times for the coiled and uncoiled tanks coupled with the CW pump design are 159 and 83 minutes, respectively. All the results are provided in Table 16.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High Radiation Environment Nuclear Fragment Separator Magnet (Final Report)

Dipole magnets with a field of 2 T are needed for the 30° bend in the Facility for Rare Isotope Beams (FRIB) fragment separator. This magnet will be subjected to extremely high radiation and heat loads from the high radiation. Superconducting coils for this magnet would allow low power operation but traditional NbTi and Nb3Sn superconductors are sensitive to quenches from beam loss and must operate near 4.5 K where the removal of thermal heat generated by beam loss is inefficient due to basic Carnot principles. High Temperature Superconductor (HTS) offers a unique solution for the magnets in the high radiation environment expected at FRIB. These conductors can operate at 40 K where heat removal is an order of magnitude more efficient than at 4.5 K. The curved separator dipoles subtend a large angular bend which introduces some complications in the winding of the coils. One approach would be to wind the coils with a curved section on the inner and outer radial segments (banana shaped). The inner radial segment would be wound with a negative curvature that would tend to unwind. An alternate approach would be to use a straight segment on the inner segment to avoid the negative curvature (D-shaped). In Phase I coils with a limited number of turns were successfully wound for both configurations described. These coils were tested at 77 K in liquid nitrogen. The Phase II program concentrated on the design, structural analysis, prototyping and test of the HTS curved dipole coils required for the high radiation environment of the FRIB fragment separator region. A thermal analysis was performed to simulate that the heat load can be removed. A test coil containing 500 m of HTS conductor was constructed to be tested at the 40 K operating temperature. The anticipated heat load was simulated with heater strips to demonstrate that the heat can be removed and that the coil can operate in a stable state.

99 GENERAL AND MISCELLANEOUS↗

Eddy Current Lift-Off Sensor Model

Eddy current sensors measure the lift-off or distance between the sensor head and a conducting surface. The sensor consists of a conducting coil carrying an alternating electrical current. By Faraday’s Law, a magnetic field is generated within the coil. This field induces electrical current loops within the conducting surface which in turn generate a magnetic field. This induced magnetic field opposes the coil magnetic field and thus, the current in the coil. This reduces the inductance of the coil while increasing its resistance. The strength of the induced magnetic field and consequently the coil inductance are proportional to the lift-off of the coil from the surface. Thus, a measurement of the coil inductance may yield a measure of the lift-off.

42 ENGINEERING↗

Radially Focused Eddy Current Sensor for Detection of Longitudinal Flaws in Metallic Tubes

A radially focused eddy current sensor detects longitudinal flaws in a metal tube. A drive coil induces eddy currents within the wall of the metal tube. A pick-up cod is spaced apart from the drive coil along the length of the metal tube. The pick@up coil is positioned with one end thereof lying adjacent the wall of the metal tube such that the pick-up coil's longitudinal axis is perpendicular to the wall of the metal tube. To isolate the pick-up coil from the magnetic flux of the drive coil and the flux from the induced eddy currents. except the eddy currents diverted by a longitudinal flaw. an electrically conducting material high in magnetic permeability surrounds all of the pick-up coil except its one end that is adjacent the walls of the metal tube. The electrically conducting material can extend into and through the drive coil in a coaxial relationship therewith.

Wincheski, Russell A.↗

Thrust Stand Measurements of the Microwave Assisted Discharge Inductive Plasma Accelerator

Pulsed inductive plasma thrusters [1-3] are spacecraft propulsion devices in which electrical energy is capacitively stored and then discharged through an inductive coil. This type of pulsed thruster is electrodeless, with a time-varying current in the coil interacting with a plasma covering the face of the coil to induce a plasma current. Propellant is accelerated and expelled at a high exhaust velocity (O(10-100 km/s)) by the Lorentz body force arising from the interaction of the magnetic field and the induced plasma current. While this class of thruster mitigates the life-limiting issues associated with electrode erosion, pulsed inductive plasma thrusters require high pulse energies to inductively ionize propellant. The Microwave Assisted Dis- charge Inductive Plasma Accelerator (MAD-IPA), shown in Fig. 1, is a pulsed inductive plasma thruster that addressees this issue by partially ionizing propellant inside a conical inductive coil before the main current pulse via an electron cyclotron resonance (ECR) discharge. The ECR plasma is produced using microwaves and a static magnetic field from a set of permanent magnets arranged to create a thin resonance region along the inner surface of the coil, restricting plasma formation, and in turn current sheet formation, to a region where the magnetic coupling between the plasma and the theta-pinch coil is high. The use of a conical theta-pinch coil also serves to provide neutral propellant containment and plasma plume focusing that is improved relative to the more common planar geometry of the Pulsed Inductive Thruster (PIT) [1, 2]. In this paper, we describe thrust stand measurements performed to characterize the performance (specific impulse, thrust efficiency) of the MAD-IPA thruster. Impulse data are obtained at various pulse energies, mass flow rates and inductive coil geometries. Dependencies on these experimental parameters are discussed in the context of the current sheet formation and electromagnetic plasma acceleration processes.

Hallock, Ashley K.↗